Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Takuto Hikichi is active.

Publication


Featured researches published by Takuto Hikichi.


Digestive Endoscopy | 2012

Prospective evaluation of the optimal number of 25-gauge needle passes for endoscopic ultrasound-guided fine-needle aspiration biopsy of solid pancreatic lesions in the absence of an onsite cytopathologist

Rei Suzuki; Atsushi Irisawa; Manoop S. Bhutani; Takuto Hikichi; Tadayuki Takagi; Ai Sato; Masaki Sato; Tsunehiko Ikeda; Ko Watanabe; Jun Nakamura; Kazuhiro Tasaki; Katsutoshi Obara; Hiromasa Ohira

Introduction:  A prior study with 22‐gauge needles recommended more than seven needle passes for endoscopic ultrasound‐guided fine‐needle aspiration biopsy (EUS‐FNA) of solid pancreatic lesions (SPL) without onsite cytopathology for optimal acquisition of cytopathological diagnosis. The feasibility of this recommendation should be re‐evaluated considering the later development and popularity of 25‐gauge EUS‐FNA needles. We aimed to determine the optimal number of needle passes for cytopathological specimen acquisition with 25‐gauge needles for EUS‐FNA of SPL.


Journal of Hepato-biliary-pancreatic Sciences | 2012

Phase I trial of preoperative intratumoral injection of immature dendritic cells and OK-432 for resectable pancreatic cancer patients

Hisahito Endo; Takuro Saito; Akira Kenjo; Mika Hoshino; Masanori Terashima; Tetsu Sato; Takayuki Anazawa; Takashi Kimura; Takao Tsuchiya; Atsushi Irisawa; Hiromasa Ohira; Takuto Hikichi; Tadayuki Takagi; Mitsukazu Gotoh

PurposeTo determine the feasibility, safety and histological change of preoperative endoscopic ultrasound-guided fine-needle injection (PEU-FNI) of immature DCs (iDCs) with OK-432 in pancreatic cancer patients.MethodsNine patients enrolled in the trial (DC group) and were compared with 15 patients operated on without iDC injection (non-DC group). Adverse events of PEU-FNI and postoperative complications were evaluated according to CTC-AE ver.3.0 and the Clavien–Dindo classification/ISGPF definition, respectively. Histological changes within the tumor and lymph nodes were evaluated by immunohistochemical examination of infiltrating inflammatory cells (CD4+, CD8+, Foxp3+ and CD83+).ResultsThere were no severe toxicities following PEU-FNI, except for one transient grade 3 fever, and there were no significant differences in the incidence of postoperative complications between the two groups. Colliquative necrosis and diffusely scattered TUNEL-positive cells were observed at the injection sites. CD83+ cells significantly accumulated in the regional lymph nodes of the DC group as well as Foxp3+ cells in the regional and distant lymph nodes. The two DC group patients, one of which was stage IV with distant lymph node metastasis, survived more than 5 years without requiring adjuvant theraphy.ConclusionPEU-FNI was feasible and safe, and further study needs to confirm and enhance antitumor responses.


World Journal of Gastroenterology | 2015

Efficacy of endoscopic ultrasonography-guided fine needle aspiration for pancreatic neuroendocrine tumor grading

Mitsuru Sugimoto; Tadayuki Takagi; Takuto Hikichi; Rei Suzuki; Ko Watanabe; Jun Nakamura; Hitomi Kikuchi; Naoki Konno; Yuichi Waragai; Hiroyuki Asama; Mika Takasumi; Hiroshi Watanabe; Katsutoshi Obara; Hiromasa Ohira

AIM To evaluate the efficacy of endoscopic ultrasonography-guided fine needle aspiration (EUS-FNA) for grading pancreatic neuroendocrine tumors (PNETs). METHODS A total of 22 patients were diagnosed with PNET by EUS-FNA between October 2001 and December 2013 at Fukushima Medical University Hospital. Among these cases, we targeted 10 PNET patients who were evaluated according to the World Health Organization (WHO) 2010 classification. Surgery was performed in eight patients, and chemotherapy was performed in two patients due to multiple liver metastases. Specimens obtained by EUS-FNA were first stained with hematoxylin and eosin and then stained with chromogranin, synaptophysin, CD56, and Ki-67. The specimens were graded by the Ki-67 index according to the WHO 2010 classification. Specimens obtained by surgery were graded by the Ki-67 index and mitotic count (WHO 2010 classification). For the eight specimens obtained by EUS-FNA, the Ki-67 index results were compared with those obtained by surgery. In the two cases treated with chemotherapy, the effects and prognoses were evaluated. RESULTS The sampling rate for histological diagnosis by EUS-FNA was 100%. No adverse effects were observed. The concordance rate between specimens obtained by EUS-FNA and surgery was 87.5% (7/8). For the two cases treated with chemotherapy, case 1 received somatostatin analog therapy and transcatheter arterial infusion (TAI) targeting multiple liver metastases. Subsequent treatment consisted of everolimus. During chemotherapy, the primary tumor remained unconfirmed, although the multiple liver metastases diminished dramatically. Case 2 was classified as neuroendocrine carcinoma (NEC) according to the Ki-67 index of a specimen obtained by EUS-FNA; therefore, cisplatin and irinotecan therapy was started. However, severe adverse effects, including renal failure and diarrhea, were observed, and the therapy regimen was changed to cisplatin and etoposide. TAI targeting multiple liver metastases was performed. Although the liver metastases diminished, the primary tumor remained unconfirmed. These chemotherapy regimens had immediate effects for both unresectable neuroendocrine tumor (NET) and NEC cases. These two subjects are still alive. CONCLUSION EUS-FNA was effective for PNET diagnosis and Ki-67 index grading for WHO 2010 classification, enabling informed decisions on unresectable PNET treatment by identifying NET or NEC.


Journal of Hepato-biliary-pancreatic Surgery | 2009

Pancreatobiliary drainage using the EUS-FNA technique: EUS-BD and EUS-PD

Atsushi Irisawa; Takuto Hikichi; Goro Shibukawa; Tadayuki Takagi; Takeru Wakatsuki; Yuta Takahashi; Hidemichi Imamura; Ai Sato; Masaki Sato; Tsunehiko Ikeda; Rei Suzuki; Katsutoshi Obara; Hiromasa Ohira

The recent progression of endoscopic ultrasonography (EUS) enables EUS-guided transmural drainage based on the EUS-guided fine-needle aspiration biopsy technique. Prior to the development of EUS-guided drainage procedures, the options for treating obstruction of the pancreatobiliary system included surgical drainage, percutaneous drainage using ultrasound and radiological guidance, and endoscopic (non EUS-guidance) transmural drainage. Today, using EUS guidance and dedicated accessories, it is possible to create bilio- or pancreato-digestive anastomosis, EUS-guided biliary drainage (EUS-BD), and EUS-guided pancreatic drainage (EUS-PD). The recent literature describes that EUS-BD and EUS-PD have acceptable success and complication rates. These procedures are anticipated for use as alternatives to surgery or percutaneous drainage when endoscopic transpapillary procedures fail.


World Journal of Gastrointestinal Endoscopy | 2014

An automated spring-loaded needle for endoscopic ultrasound-guided abdominal paracentesis in cancer patients.

Rei Suzuki; Atsushi Irisawa; Manoop S. Bhutani; Takuto Hikichi; Tadayuki Takagi; Goro Shibukawa; Ai Sato; Masaki Sato; Tsunehiko Ikeda; Ko Watanabe; Jun Nakamura; Srinadh Annangi; Kazuhiro Tasaki; Katsutoshi Obara; Hiromasa Ohira

AIM To evaluate the feasibility of using an automated spring-loaded needle device for endoscopic ultrasound (EUS)-guided abdominal paracentesis (EUS-P) to see if this would make it easier to puncture the mobile and lax gastric wall for EUS-P. METHODS The EUS database and electronic medical records at Fukushima Medical University Hospital were searched from January 2001 to April 2011. Patients with a history of cancer and who underwent EUS-P using an automated spring-loaded needle device with a 22-gauge puncture needle were included. The needle was passed through the instrument channel and advanced through the gastrointestinal wall under EUS guidance into the echo-free space in the abdominal cavity and ascitic fluid was collected. The confirmed diagnosis of malignant ascites included positive cytology and results from careful clinical observation for at least 6 mo in patients with negative cytology. The technical success rate, cytology results and complications were evaluated. RESULTS We found 11 patients who underwent EUS-P with an automated spring-loaded needle device. In 4 cases, ascites was revealed only with EUS but not in other imaging modalities. EUS-P was done in 7 other cases because there was minimal ascitic fluid and no safe window for percutaneous abdominal aspiration. Ascitic fluid was obtained in all cases by EUS-P. The average amount aspirated was 14.1 mL (range 0.5-38 mL) and that was sent for cytological exam. The etiology of ascitic fluid was benign in 5 patients and malignant in 6. In all cases, ascitic fluid was obtained with the first needle pass. No procedure-related adverse effects occurred. CONCLUSION EUS-P with an automated spring-loaded needle device is a feasible and safe method for ascites evaluation.


Gastrointestinal Endoscopy | 2009

Basic technique of FNA

Atsushi Irisawa; Takuto Hikichi; Manoop S. Bhutani; Hiromasa Ohira

EUS-guided FNA (EUS-FNA) has emerged as an effective technique for tissue diagnosis in patients with abnormalities of various organs. For this reason, EUS-FNA is now frequently incorporated into the management algorithms of patients with suspected mediastinal or abdominal neoplasms. Moreover, interventional EUS has recently spread worldwide, not only for diagnostic intervention but also for therapeutic intervention. The use of EUS-FNA is fundamental in various interventional EUS, and learning the basic techniques of EUS-FNA is important to perform EUS-FNA with high efficacy. In this article, the basic EUSFNA technique is interpreted by referring to the medical literature.


Diagnostic and Therapeutic Endoscopy | 2009

Two Cases of Retroperitoneal Liposarcoma Diagnosed Using Endoscopic Ultrasound-Guided Fine-Needle Aspiration (EUS-FNA)

Yuta Takahashi; Atsushi Irisawa; Manoop S. Bhutani; Takuto Hikichi; Tadayuki Takagi; Goro Shibukawa; Takeru Wakatsuki; Hidemichi Imamura; Ai Sato; Masaki Sato; Tsunehiko Ikeda; Rei Suzuki; Katsutoshi Obara; Yuko Hashimoto; Kazuo Watanabe; Hiromasa Ohira

This report describes our experience with two cases that were ultimately diagnosed as retroperitoneal liposarcoma using endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA). Case 1 is that of a 54-year-old woman with chief complaints of nausea and abdominal distention. Computed tomography (CT) and magnetic resonance imaging (MRI) revealed a large (15 cm diameter) tumor, which was significantly compressing the stomach and apparently occupied the entire left abdominal cavity. Although advanced primary gastrointestinal stromal tumor (GIST) or retroperitoneal tumor was inferred as the differential diagnosis, a definitive diagnosis was difficult using imaging alone. After EUS-FNA was done, the tumor was diagnosed histopathologically as high-grade liposarcoma. Case 2 is that of a 73-year-old man. Abdominal ultrasonography and CT showed a 6 cm diameter tumor within the pelvic cavity. The tumor had high MRI signal-intensity on both T1 and T2 images. Endorectal EUS showed a hyperechoic mass. The images suggested lipoma or liposarcoma containing lipoma-like components. Myxoid liposarcoma was revealed by subsequent EUS-FNA. Performing EUS-FNA was clinically useful for determining the subsequent therapeutic strategy in these cases where a tumor of unknown origin existed in the retroperitoneum.


Digestive Endoscopy | 2010

Feasibility of interventional endoscopic ultrasound using forward-viewing and curved linear-array echoendoscope: a literature review.

Atsushi Irisawa; Hiroshi Imaizumi; Takuto Hikichi; Tadayuki Takagi; Hiromasa Ohira

Oblique‐viewing curved linear‐array echoendoscopes are widely used for interventional endoscopic ultrasound (EUS), not only for diagnostic but also for therapeutic procedures. Recently, development of a forward‐viewing curved linear‐array echoendoscope (FV‐ES) has been made. Several reports describe the usefulness of this new equipment for therapeutic interventional EUS, especially for pseudocyst drainage. A salient advantage of the FV‐ES is that it enables the axial application of force during needle insertion and stenting. Furthermore, by attaching a cap device to the tip, the endoscopes capability can be expanded. Although the FV‐ES has a narrower scanning range (90 deg) than that afforded by the oblique‐viewing curved linear‐array echoendoscope (180 deg), this characteristic reportedly does not hinder the performance of interventional EUS. The FV‐ES might contribute to the advancement of interventional EUS.


PLOS ONE | 2015

Efficacy of Steroid Pulse Therapy for Autoimmune Pancreatitis Type 1: A Retrospective Study

Mitsuru Sugimoto; Tadayuki Takagi; Rei Suzuki; Naoki Konno; Ko Watanabe; Jun Nakamura; Hitomi Kikuchi; Yuichi Waragai; Hiroyuki Asama; Mika Takasumi; Takuto Hikichi; Hiroshi Watanabe; Katsutoshi Obara; Hiromasa Ohira

Autoimmune pancreatitis (AIP) is treatable with steroids, but relapse is frequent. The efficacy of steroid pulse therapy has been shown for various autoimmune diseases, but has not become established therapy. In this study, we reviewed the efficacy of steroid pulse therapy in 24 subjects who were diagnosed with AIP type 1 at our hospital. Patient characteristics, time-course of serum IgG4, and the cumulative relapse-free survival rate were compared between patients who received oral steroid therapy (oral group) and those who were treated with steroid pulse therapy (pulse group). Serum IgG4 was reduced significantly after therapy in both groups and the 5-year cumulative relapse-free survival rates in the two groups did not differ significantly (oral group 46.9%, pulse group 77.8%). However, in a subset of cases with diffuse pancreatic swelling, this rate was significantly lower in the oral group (33.3% vs. 100.0%, p = 0.046). These results suggest that steroid pulse therapy is effective for prevention of relapse in AIP patients with diffuse pancreatic swelling.


World Journal of Gastrointestinal Endoscopy | 2012

Acute inflammation occurring in gastric aberrant pancreas followed up by endoscopic ultrasonography.

Ko Watanabe; Atsushi Irisawa; Takuto Hikichi; Tadayuki Takagi; Goro Shibukawa; Masaki Sato; Katsutoshi Obara; Hiromasa Ohira

We describe a case of gastric aberrant pancreas with acute pancreatitis followed up with subsequent endoscopic ultrasound. A 20-year-old woman known to have aberrant pancreas in the stomach was admitted to our hospital because of severe epigastralgia. Laboratory tests showed slight C reactive protein elevation without hyperamylasemia. Esophagogastroduodenoscopy revealed a swollen submucosal lesion (SML) to a greater degree compared with the previous findings. Subsequent endoscopic ultrasonography (EUS) revealed a swollen lesion of 35 mm in diameter. The internal echo-pattern was more hypoechoic than in the previous EUS. The border between the fourth layer (muscularis propria) and the SML was unclear. The anechoic lumen in the mass, considered as the ductal lumen, was dilated. Based on these results, we diagnosed the patient as having acute inflammation, resembling pancreatitis, in the aberrant pancreas.

Collaboration


Dive into the Takuto Hikichi's collaboration.

Top Co-Authors

Avatar

Tadayuki Takagi

Fukushima Medical University

View shared research outputs
Top Co-Authors

Avatar

Hiromasa Ohira

Fukushima Medical University

View shared research outputs
Top Co-Authors

Avatar

Katsutoshi Obara

Fukushima Medical University

View shared research outputs
Top Co-Authors

Avatar

Rei Suzuki

Fukushima Medical University

View shared research outputs
Top Co-Authors

Avatar

Atsushi Irisawa

Fukushima Medical University

View shared research outputs
Top Co-Authors

Avatar

Jun Nakamura

Fukushima Medical University

View shared research outputs
Top Co-Authors

Avatar

Ko Watanabe

Fukushima Medical University

View shared research outputs
Top Co-Authors

Avatar

Masaki Sato

Fukushima Medical University

View shared research outputs
Top Co-Authors

Avatar

Mitsuru Sugimoto

Fukushima Medical University

View shared research outputs
Top Co-Authors

Avatar

Goro Shibukawa

Fukushima Medical University

View shared research outputs
Researchain Logo
Decentralizing Knowledge