Tanja Vollmer
Ruhr University Bochum
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Tanja Vollmer.
Journal of Clinical Microbiology | 2012
Tanja Vollmer; Juergen Diekmann; Reimar Johne; Matthias Eberhardt; Cornelius Knabbe; Jens Dreier
ABSTRACT The risk of transfusion-transmitted hepatitis E virus (HEV) infections by contaminated blood products remains unknown. In the present study, we evaluated and compared different nucleic acid amplification technique (NAT) methods for the detection of HEV in blood components. Minipools of a total of 16,125 individual blood donors were screened for the presence of HEV RNA using the highly sensitive RealStar HEV RT-PCR kit, revealing a minimum detection limit of 4.66 IU/ml. Thirteen donors were HEV RNA positive (0.08%), and of these donors, only three already showed reactive IgM antibody titers. The detected HEV strains all belonged to genotype 3 and were most closely related to German HEV strains from wild boars and pigs as well as from human hepatitis E cases. Furthermore, HEV RNA and HEV-specific IgM and IgG titers were determined in 136 blood donors with elevated alanine aminotransferase (ALT) levels and in 200 donors without pathological findings. HEV RNA was not detectable, but 8.08% (elevated ALT) and 0.5% (nonelevated ALT) of donors showed reactive HEV IgM titers. The overall seroprevalence rate of HEV IgG amounted to 5.94% (elevated ALT, 5.88%; nonelevated ALT, 6.0%). The clinical relevance of transfusion-associated hepatitis E infection still requires further investigation. However, in connection with raising concerns regarding blood safety, our NAT method provides a sensitive possibility for HEV testing.
Journal of Clinical Microbiology | 2008
Tanja Vollmer; Melanie Störmer; Knut Kleesiek; Jens Dreier
ABSTRACT In the present study, a novel broad-range real-time PCR was developed for the rapid detection of human pathogenic fungi. The assay targets a part of the 28S large-subunit ribosomal RNA (rDNA) gene. We investigated its application for the most important human pathogenic fungal genera, including Aspergillus, Candida, Cryptococcus, Mucor, Penicillium, Pichia, Microsporum, Trichophyton, and Scopulariopsis. Species were identified in PCR-positive reactions by direct DNA sequencing. A noncompetitive internal control was applied to prevent false-negative results due to PCR inhibition. The minimum detection limit for the PCR was determined to be one 28S rDNA copy per PCR, and the 95% detection limit was calculated to 15 copies per PCR. To assess the clinical applicability of the PCR method, intensive-care patients with artificial respiration and patients with infective endocarditis were investigated. For this purpose, 76 tracheal secretion samples and 70 heart valve tissues were analyzed in parallel by real-time PCR and cultivation. No discrepancies in results were observed between PCR analysis and cultivation methods. Furthermore, the application of the PCR method was investigated for other clinical specimens, including cervical swabs, nail and horny skin scrapings, and serum, blood, and urine samples. The combination of a broad-range real-time PCR and direct sequencing facilitates rapid screening for fungal infection in various clinical specimens.
Systematic and Applied Microbiology | 2011
Dennis Hinse; Tanja Vollmer; M. Erhard; Martin Welker; Edward R. B. Moore; Knut Kleesiek; Jens Dreier
The Streptococcus bovis/equinus complex is a heterogeneous group within the group D streptococci with important clinical relevance regarding infective endocarditis, sepsis and colon carcinoma. The taxonomic identification of species and sub-species of this complex, by the standard methods remains difficult. In the present study, we compared the cluster analysis of 88 strains of species of the S. bovis/equinus complex by sequence analysis of the manganese-dependent superoxide dismutase gene (sodA) and by Matrix Assisted Laser Desorption/Ionization-Time Of Flight Mass Spectrometry (MALDI-TOF MS). We observed a high congruence of strain grouping by MALDI-TOF MS in comparison with sodA sequence analyses, demonstrating the accuracy and reliability of MALDI-TOF MS in comparison to DNA sequence-based method. By generating mass spectra for each species and sub-species, we were able to discriminate all members of the S. bovis/equinus complex. Furthermore, we demonstrated reliable identifications to the species level by MALDI-TOF MS, independently of cultivation conditions.
Clinical Chemistry | 2009
Jens Dreier; Tanja Vollmer; Knut Kleesiek
BACKGROUND Bacterial contamination is the major infectious hazard associated with transfusion of platelet preparations (PLTs). Routine testing for bacterial contamination in PLTs has become common, but transfusion-transmitted bacterial sepsis has not been eliminated. Here, we describe a novel flow cytometry-based method for point-of-issue screening of PLTs for bacterial contamination. METHODS We used the BactiFlow flow cytometer to detect and count bacteria based on esterase activity in viable cells. We compared the assay to incubation (BacT/Alert culture system) and rapid nucleic acid-based or immunoassay (reverse transcription PCR, Pan Genera Detection) methods. RESULTS We established a protocol for bacterial screening of PLTs consisting of enzymatic digestion and centrifugal filtration for the elimination of viable platelets and selective labeling of bacteria with fluorescent esterase substrate (ChemChrome V23). Results from the BactiFlow showed an excellent correlation (r = 0.9923 E. coli, r = 0.9736 S. epidermidis) to traditional plate count results. The lower detection limit of the assay was determined to be 150 CFU/mL, and the time to result was <1 h. CONCLUSIONS Our study demonstrates that BactiFlow flow cytometry is suitable for rapid screening of PLTs for bacterial contamination and fulfils the requirements for a point-of-issue testing of PLTs with acceptable time to result, specificity, sensitivity, and cost.
Vox Sanguinis | 2014
R. N. I. Pietersz; H. W. Reesink; S. Panzer; S. Oknaian; S. Kuperman; Christian Gabriel; A. Rapaille; Micheline Lambermont; Véronique Deneys; D. Sondag; Sandra Ramirez-Arcos; Mindy Goldman; G. Delage; F. Bernier; Michael J. Germain; T. Vuk; Jørgen Georgsen; P. Morel; C. Naegelen; L. Bardiaux; J.-P. Cazenave; Jens Dreier; Tanja Vollmer; Cornelius Knabbe; Erhard Seifried; Kai M. Hourfar; C.K. Lin; M. Spreafico; L. Raffaele; A. Berzuini
R. N. I. Pietersz, H. W. Reesink, S. Panzer, S. Oknaian, S. Kuperman, C. Gabriel, A. Rapaille, M. Lambermont, V. Deneys,D. Sondag, S. Ramirez-Arcos, M. Goldman, G. Delage, F. Bernier, M. Germain, T. Vuk, J. Georgsen, P. Morel, C. Naegelen,L. Bardiaux, J.-P. Cazenave, J. Dreier, T. Vollmer, C. Knabbe, E. Seifried, K. Hourfar, C. K. Lin, M. Spreafico, L. Raffaele,A. Berzuini, D. Prati, M. Satake, D. de Korte, P. F. van der Meer, J. L. Kerkhoffs, L. Blanco, J. Kjeldsen-Kragh,A.-M. Svard-Nilsson, C. P. McDonald, I. Symonds, R. Moule, S. Brailsford, R. Yomtovian & M. R. JacobsSeptic reactions after transfusion, particularly of plateletconcentrates, still occur and belong to the most serioustransfusion reactions. From a previous InternationalForum [1] on the subject, it could be concluded that inpart of the countries that participated in the forum, plate-let concentrates (PCs) were tested for bacterial contamina-tion and that culture-based methods, particularly theBacT/Alert system, were used.In recent years, several rapid bacterial detection meth-ods, such as surrogate measurements of the pH or glu-cose, the detection of bacteria with a scan system orPCR tests that detect bacterial RNA, have been devel-oped. These tests can either be performed immediatelyprior to transfusion of the PC or at a variety of testmoments at which culture and release tests are com-bined.Pathogen inactivation (PI) methods also affect bacterialcontamination of PCs. In 2007 [1], in some countries, theIntercept method of PI of PCs was implemented insteadof bacterial screening.It seemed of interest to evaluate the present state ofthe art of this subject. In order to obtain the desiredinformation, the following questions were sent to expertsin the field.Question 1: How long do you store PC and is there adifference between whole-blood-derived PC and apheresisPC? Which method of preparation do you use for whole-blood-derived PC? Are PCs leuco-reduced?Question 2: Do you use a culture method to detect bac-terial contamination of PC? If so,
BMC Microbiology | 2010
Tanja Vollmer; Dennis Hinse; Knut Kleesiek; Jens Dreier
BackgroundStreptococcus gallolyticus subsp. gallolyticus is an important causative agent of infective endocarditis (IE) but the knowledge on virulence factors is limited and the pathogenesis of the infection is poorly understood. In the present study, we established an experimental in vitro IE cell culture model using EA.hy926 and HUVEC cells to investigate the adhesion and invasion characteristics of 23 Streptococcus gallolyticus subsp. gallolyticus strains from different origins (human IE-derived isolates, other human clinical isolates, animal isolates). Adhesion to eight components of the extracellular matrix (ECM) and the ability to form biofilms in vitro was examined in order to reveal features of S. gallolyticus subsp. gallolyticus endothelial infection. In addition, the strains were analyzed for the presence of the three virulence factors gtf, pilB, and fimB by PCR.ResultsThe adherence to and invasion characteristics of the examined S. gallolyticus subsp. gallolyticus strains to the endothelial cell line EA.hy926 differ significantly among themselves. In contrast, the usage of three different in vitro models (EA.hy926 cells, primary endothelial cells (HUVECs), mechanical stretched cells) revealed no differences regarding the adherence to and invasion characteristics of different strains. Adherence to the ECM proteins collagen I, II and IV revealed the highest values, followed by fibrinogen, tenascin and laminin. Moreover, a strong correlation was observed in binding to these proteins by the analyzed strains. All strains show the capability to adhere to polystyrole surfaces and form biofilms. We further confirmed the presence of the genes of two known virulence factors (fimB: all strains, gtf: 19 of 23 strains) and demonstrated the presence of the gene of one new putative virulence factor (pilB: 9 of 23 strains) by PCR.ConclusionOur study provides the first description of S. gallolyticus subsp. gallolyticus adhesion and invasion of human endothelial cells, revealing important initial information of strain variability, behaviour and characteristics of this as yet barely analyzed pathogen.
BMC Infectious Diseases | 2012
Mareike Dabisch-Ruthe; Tanja Vollmer; Ortwin Adams; Cornelius Knabbe; Jens Dreier
BackgroundA broad spectrum of pathogens is causative for respiratory tract infections, but symptoms are mostly similar. Therefore, the identification of the causative viruses and bacteria is only feasible using multiplex PCR or several monoplex PCR tests in parallel.MethodsThe analytical sensitivity of three multiplex PCR assays, RespiFinder-19, RespiFinder-SMART-22 and xTAG-Respiratory-Virus-Panel-Fast-Assay (RVP), were compared to monoplex real-time PCR with quantified standardized control material. All assays include the most common respiratory pathogens.ResultsTo compare the analytical sensitivity of the multiplex assays, samples were inoculated with 13 different quantified viruses in the range of 101 to 105 copies/ml. Concordant results were received for rhinovirus, whereas the RVP detected influenzavirus, RSV and hMPV more frequently in low concentrations. The RespiFinder-19 and the RespiFinder-SMART-22 showed a higher analytical sensitivity for adenoviruses and coronaviruses, whereas the RVP was incapable to detect adenovirus and coronavirus in concentrations of 104 copies/ml. The RespiFinder-19 and RespiFinder-SMART-22A did not detect influenzaviruses (104 copies/ml) and RSV (103 copies/ml). The detection of all 13 viruses in one sample was only achieved using monoplex PCR. To analyze possible competitive amplification reactions between the different viruses, samples were further inoculated with only 4 different viruses in one sample. Compared to the detection of 13 viruses in parallel, only a few differences were found.The incidence of respiratory viruses was compared in tracheal secretion (TS) samples (n = 100) of mechanically ventilated patients in winter (n = 50) and summer (n = 50). In winter, respiratory viruses were detected in 32 TS samples (64%) by RespiFinder-19, whereas the detection rate with RVP was only 22%. The most frequent viruses were adenovirus (32%) and PIV-2 (20%). Multiple infections were detected in 16 TS samples (32%) by RespiFinder-19. Fewer infections were found in summer (RespiFinder-19: 20%; RVP: 6%). All positive results were verified using monoplex PCR.ConclusionsMultiplex PCR tests have a broad spectrum of pathogens to test at a time. Analysis of multiple inoculated samples revealed a different focus of the detected virus types by the three assays. Analysis of clinical samples showed a high concordance of detected viruses by the RespiFinder-19 compared to monoplex tests.
BMC Genomics | 2011
Dennis Hinse; Tanja Vollmer; Christian Rückert; Jochen Blom; Jörn Kalinowski; Cornelius Knabbe; Jens Dreier
BackgroundStreptococcus gallolyticus subsp. gallolyticus is an important causative agent of infectious endocarditis, while the pathogenicity of this species is widely unclear. To gain insight into the pathomechanisms and the underlying genetic elements for lateral gene transfer, we sequenced the entire genome of this pathogen.ResultsWe sequenced the whole genome of S. gallolyticus subsp. gallolyticus strain ATCC BAA-2069, consisting of a 2,356,444 bp circular DNA molecule with a G+C-content of 37.65% and a novel 20,765 bp plasmid designated as pSGG1. Bioinformatic analysis predicted 2,309 ORFs and the presence of 80 tRNAs and 21 rRNAs in the chromosome. Furthermore, 21 ORFs were detected on the plasmid pSGG1, including tetracycline resistance genes telL and tet(O/W/32/O). Screening of 41 S. gallolyticus subsp. gallolyticus isolates revealed one plasmid (pSGG2) homologous to pSGG1. We further predicted 21 surface proteins containing the cell wall-sorting motif LPxTG, which were shown to play a functional role in the adhesion of bacteria to host cells. In addition, we performed a whole genome comparison to the recently sequenced S. gallolyticus subsp. gallolyticus strain UCN34, revealing significant differences.ConclusionsThe analysis of the whole genome sequence of S. gallolyticus subsp. gallolyticus promotes understanding of genetic factors concerning the pathogenesis and adhesion to ECM of this pathogen. For the first time we detected the presence of the mobilizable pSGG1 plasmid, which may play a functional role in lateral gene transfer and promote a selective advantage due to a tetracycline resistance.
International Journal of Medical Microbiology | 2009
Melanie Störmer; Tanja Vollmer; Birgit Henrich; Knut Kleesiek; Jens Dreier
Polymerase chain reaction assays have become widely used methods of confirming the presence of Mollicutes species in clinical samples and cell cultures. We have developed a broad-range real-time PCR assay using the locked nucleic acid technology to detect mollicute species causing human infection and cell line contamination. Primers and probes specifically for the conserved regions of the mycoplasmal tuf gene (encoding elongation factor Tu) were designed. Cell culture supernatants, clinical specimens (vaginal swabs, sputum, cryopreserved heart valve tissues), and reference strains were tested for mollicute contamination as well as to exclude cross-reaction to human nucleic acids and other bacterial species. Nucleic acids were extracted using magnetic separation technology. The coamplification of the human beta2-microglobulin DNA served as an internal control. The PCR assay was highly specific and obtained an analytical sensitivity of one copy per microl sample. The 95% detection limit was calculated to 10 copies per microl sample for Mycoplasma pneumoniae and M. orale. No false-positive results were observed due to cross-reaction of walled bacterial, fungal, and human nucleic acids. To evaluate the PCR, we compared the results to two commercialized test systems. Moreover, in combination with a previously developed broad-range RT-PCR assay for the detection of bacteria in blood products, both mollicute and walled bacterial contamination can be detected simultaneously using multiplex real-time RT-PCR.
Journal of Clinical Microbiology | 2010
Tanja Vollmer; Dennis Hinse; Knut Kleesiek; Jens Dreier
ABSTRACT Bacterial contamination of platelet concentrates (PCs) still represents an ongoing risk in transfusion-transmitted sepsis. Recently the Pan Genera Detection (PGD) system was developed and FDA licensed for screening of bacterial contamination of PCs directly prior to transfusion. The test principle is based on the immunological detection of lipopolysaccharide (for Gram-negative bacteria) or lipoteichoic acid (for Gram-positive bacteria). In the present study we analyzed the applicability of this method with regard to detection limit, practicability, implementation, and performance. PCs were spiked with Staphylococcus aureus, Bacillus subtilis, and five different Klebsiella pneumoniae strains, as well as eight different Escherichia coli strains. The presence of bacteria was assessed by the PGD immunoassay, and bacteria were enumerated by plating cultures. Application of the PGD immunoassay showed that it is a rapid test with a short hands-on time for sample processing and no demand for special technical equipment and instrument operation. The lower detection limits of the assay for Gram-positive bacteria showed a good agreement with the manufacturers specifications (8.2 × 103 to 5.5 × 104 CFU/ml). For some strains of K. pneumoniae and E. coli, the PGD test showed analytical sensitivities (>106 CFU/ml) that were divergent from the designated values (K. pneumoniae, 2.0 × 104 CFU/ml; E. coli, 2.8 × 104 CFU/ml). Result interpretation is sometimes difficult due to very faint bands. In conclusion, our study demonstrates that the PGD immunoassay is an easy-to-perform bedside test for the detection of bacterial contamination in PCs. However, to date there are some shortcomings in the interpretation of results and in the detection limits for some strains of Gram-negative bacteria.