Taritree Wongjirad
Massachusetts Institute of Technology
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Taritree Wongjirad.
Physical Review D | 2017
Lina Necib; Jarrett S. Moon; Taritree Wongjirad; J. M. Conrad
Current and future neutrino experiments can be used to discover dark matter, not only in searches for dark matter annihilating to neutrinos, but also in scenarios where dark matter itself scatters off Standard Model particles in the detector. In this work, we study the sensitivity of different neutrino detectors to a class of models called boosted dark matter, in which a subdominant component of a dark sector acquires a large Lorentz boost today through annihilation of a dominant component in a dark matter-dense region, such as the galactic center or dwarf spheroidal galaxies. This analysis focuses on the sensitivity of different neutrino detectors, specifically the Cherenkov-based Super-K and the future argon-based DUNE to boosted dark matter that scatters off electrons. We study the dependence of the expected limits on the experimental features, such as energy threshold, volume and exposure in the limit of constant scattering amplitude. We highlight experiment-specific features that enable current and future neutrino experiments to be a powerful tool in finding signatures of boosted dark matter.
Journal of Instrumentation | 2015
Z. Moss; J. M. Conrad; B.J.P. Jones; J.S. Moon; M. Toups; L. Bugel; Gabriel Lewis Collin; Taritree Wongjirad
Scintillation light produced in liquid argon (LAr) must be shifted from 128 nm to visible wavelengths in light detection systems used for liquid argon time-projection chambers (LArTPCs). To date, LArTPC light collection systems have employed tetraphenyl butadiene (TPB) coatings on photomultiplier tubes (PMTs) or plates placed in front of the PMTs. Recently, a new approach using TPB-coated light guides was proposed. In this paper, we report on light guides with improved attenuation lengths above 100 cm when measured in air. This is an important step in the development of meter-scale light guides for future LArTPCs. Improvements come from using a new acrylic-based coating, diamond-polished cast UV transmitting acrylic bars, and a hand-dipping technique to coat the bars. We discuss a model for connecting bar response in air to response in liquid argon and compare this to data taken in liquid argon. The good agreement between the prediction of the model and the measured response in liquid argon demonstrates that characterization in air is sufficient for quality control of bar production. This model can be used in simulations of light guides for future experiments.
Journal of Instrumentation | 2018
S.F. Pate; T. Wester; L. Bugel; J. M. Conrad; E. Henderson; B.J.P. Jones; A.I.L. McLean; J.S. Moon; M. Toups; Taritree Wongjirad
We present a model for the Global Quantum Efficiency (GQE) of the MicroBooNE optical units. An optical unit consists of a flat, circular acrylic plate, coated with tetraphenyl butadiene (TPB), positioned near the photocathode of a 20.2-cm diameter photomultiplier tube. The plate converts the ultra-violet scintillation photons from liquid argon into visible-spectrum photons to which the cryogenic phototubes are sensitive. The GQE is the convolution of the efficiency of the plates that convert the 128 nm scintillation light from liquid argon to visible light, the efficiency of the shifted light to reach the photocathode, and the efficiency of the cryogenic photomultiplier tube. We develop a GEANT4-based model of the optical unit, based on first principles, and obtain the range of probable values for the expected number of detected photoelectrons (
arXiv: Instrumentation and Detectors | 2015
S. Axani; M. H. Shaevitz; J. M. Conrad; Josh Spitz; G.H. Collin; Taritree Wongjirad
N_{rm PE}
arXiv: Instrumentation and Detectors | 2016
Z. Moss; K. Sachdev; J. M. Conrad; M. Toups; L. Bugel; J. Moon; Taritree Wongjirad
) given the known systematic errors on the simulation parameters. We compare results from four measurements of the
Journal of Instrumentation | 2018
S.F. Pate; T. Wester; L. Bugel; J. M. Conrad; E. Henderson; B.J.P. Jones; A.I.L. McLean; J.S. Moon; M. Toups; Taritree Wongjirad
N_{rm PE}
Bulletin of the American Physical Society | 2017
Matt Lindsay; Taritree Wongjirad
determined using alpha-particle sources placed at two distances from a TPB-coated plate in a liquid argon cryostat test stand. We also directly measured the radial dependence of the quantum efficiency, and find that this is the same shape as predicted by our model, a Gaussian. Our model results in a GQE of
Physical Review Letters | 2015
M. H. Shaevitz; S. Axani; Gabriel Lewis Collin; J. M. Conrad; J. Spitz; Taritree Wongjirad
0.0055pm0.0009
Archive | 2015
J. M. Conrad; S. Axani; Gabriel Lewis Collin; Michael H. Shaevitz; J. Spitz; Taritree Wongjirad
for the MicroBooNE optical units. While the information shown here is MicroBooNE specific, the approach to the model and the collection of simulation parameters will be widely applicable to many liquid-argon-based light collection systems.
Bulletin of the American Physical Society | 2015
Bruce Howard; B. Adams; Brian Baugh; Norm Buchanan; Len Bugel; J. M. Conrad; Ronald W. Davis; M. Gebhard; Michael Lang; Bill Miner; S. Mufson; J. Musser; Stephen Pordes; Brian J. Rebel; Paul Smith; Matt Toups; Jon Urheim; David Warner; Taritree Wongjirad; D. Whittington