Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Th. Ruppenthal is active.

Publication


Featured researches published by Th. Ruppenthal.


Journal of Orofacial Orthopedics-fortschritte Der Kieferorthopadie | 1991

Vergleichende Untersuchung zur Genauigkeit der Lokalisierung kephalometrischer Referenzpunkte bei Anwendung digitaler und konventioneller Aufnahmetechnik

Th. Ruppenthal; Gerhard Michael Doll; H. G. Sergl; Bradley L. Fricke

The purpose of this study was to present possible advantages of digital luminescence radiography for cephalometry. Conventional and digitalized lateral headfilms were compared and evaluated. The first impression of an improved simultaneous presentation of bony structures and soft tissue profile in digital x-rays was statistically verified. A significant difference in identification of several reference points was proven by means of the F-test. The superior results of the digital luminescence radiography were evaluated in comparison with xeroradiography and experimental postdigitalization of conventional x-rays.ZusammenfassungZiel der vorliegenden Arbeit war die Darstellung möglicher Vorteile der digitalen Lumineszenzradiographie für die Kephalometrie. Dazu wurden konventionell und digitalisiert gewonnene Fernröntgenseitenbilder vergleichend ausgewertet. Der subjektive Eindruck einer verbesserten simultanen Darstellung der knöchernen Strukturen und des Weichteilprofils in digitalen Aufnahmen ließ sich statistisch belegen. So fanden sich bezüglich der Identifikation einzelner Referenzpunkte nach Anwendung des F-Testes signifikante Unterschiede. Die Beurteilung der mit der digitalen Lumineszenzradiographie gewonnenen überlegenen Ergebnisse erfolgt unter Einbeziehung der Xeroradiographie sowie Versuchen der nachträglichen Digitalisierung von Röntgenbildern.SummaryThe purpose of this study was to present possible advantages of digital luminescence radiography for cephalometry. Conventional and digitalized lateral headfilms were compared and evaluated. The first impression of an improved simultaneous presentation of bony structures and soft tissue profile in digital x-rays was statistically verified. A significant difference in identification of several reference points was proven by means of the F-test. The superior results of the digital luminescence radiography were evaluated in comparison with xeroradiography and experimental postdigitalization of conventional x-rays.


Journal of Orofacial Orthopedics-fortschritte Der Kieferorthopadie | 1992

Elemental analytical and quantitative morphometric determination of the synthetic resin residues and enamel avulsion after the removal of metal brackets

Th. Ruppenthal; Udo Stratmann; H. G. Sergl; Daniel R. Czech

ZusammenfassungUn die Güte des Verbundsystems Schmelz-Adhäsivkunststoff-Bracket zu beurteilen, werden verschie dene klinische und experimentelle. Untersuchungen durchgeführt. Ziel der vorliegenden Studie ist die Vorstellung einer kombinierten Methode, die es ermöglicht, die Basis von Metallbrackets nach der Bracketabnahme sowohl quantitativ-morphometrisch auf Adhäsivreste zu untersuchen als auch möglicherweise vorliegende Schmelzpartikel nachzuweisen. Es wurden 38 Metallbrackets rasterelektronenmikroskopisch untersucht Morphologisch auffällige Strukturen wurden mit einer angeschlossenen Mikrosonde analysiert und als Schmelzpartikel identifiziert. Die Flächenanteile der Adhäsivreste bzw. der Schmelzpartikel wurden mit einem rechnergestützten Bildanalysesystem bestimmt Bei 24 Brackets (63%) fanden sich Adhäsivreste auf der Bracketbasis. Bei 18 Brackets (47%) ließen sich Schmelzpartikel auf der adhäsivbedeckten Bracketbasis nachweisen. Das vorgestellte Verfahren ist einfach durchführbar und gestaftet eine gegenüber einem Index zur Quantifizierung von Kunststoffresten (Adhesive Remnant Index) genauere Bestimmung von Schntelzpartikeln. Da es zur experimentellen Überprüfung empfohlener Verbesserungsansätze in der Klebetechnik universell anwendbar ist, erleichtert es deren Beurteilung.SummaryA number of clincal and experimental studies were performed to assess the quality of the enameladhesive-bracket bond. The aim was to present a combined method that enables the investigator both to examine the surface of metal brackets quantitative-morphometrically and to detect the presence of enamel particles. To this end, 38 metal brackets were examined in the scanning electron microscope. An EDAX-detecting unit was used to analyze morphologically conspicuous structures and identified them as enamel particles. The extent of adhesive remnants and enamel particles was quantified using the image analysis system IBAS. In 24 brackets (53%) bonding adhesive residue was found on the bracket base. In 18 brackets (47%) enamel particles were identified on the adhesive-bearing brackets. This method is easier to carry our and enables a more accurate quantification of enamel particles than the Adhesive Remnant Index. Since it can be applied universally to examine recommended improvements to adhesive technique it facilitates their assessment.A number of clinical and experimental studies were performed to assess the quality of the enamel-adhesive-bracket bond. The aim was to present a combined method that enables the investigator both to examine the surface of metal brackets quantitative-morphometrically and to detect the presence of enamel particles. To this end, 38 metal brackets were examined in the scanning electron microscope. An EDAX-detecting unit was used to analyze morphologically conspicuous structures and identified them as enamel particles. The extent of adhesive remnants and enamel particles was quantified using the image analysis system IBAS. In 24 brackets (53%) bonding adhesive residue was found on the bracket base. In 18 brackets (47%) enamel particles were identified on the adhesive-bearing brackets. This method is easier to carry out and enables a more accurate quantification of enamel particles than the Adhesive Remnant Index. Since it can be applied universally to examine recommended improvements to adhesive technique, it facilitates their assessment.


Journal of Orofacial Orthopedics-fortschritte Der Kieferorthopadie | 1992

Vergleichende Untersuchung zur Möglichkeit der Dosisreduzierung von Fernröntgenseitenaufnahmen

Th. Ruppenthal; Bradley L. Fricke; H. G. Sergl; Gerhard Michael Doll

Thanks to their capability for post-processing of image data, the digital radiological techniques introduced from 1970 onwards permit dose reduction with no loss of clinical information. The aim of this study was to establish the extent of possible dose reduction in orthodontic lateral cephalography. For this purpose, lateral cephalograms of a head phantom taken with varying radiation doses (5 to 150 mAs, constant 70 kV) were evaluated. The evaluations of ten judges were compared statistically. Conventional lateral cephalograms showed a statistically proven superiority of a number of exposure parameters for the sagittal and vertical localisation of reference points. This correlated with the radiological density of the structures. In contrast to the conventional technique, the reference points in all images obtained by digital luminescence radiography showed no such tendency. Digital luminescence thus meets the clinical need to reduce radiation dose (to about 20% of the usual dose) while providing no less diagnostic information.ZusammenfassungSeit 1970 eingeführte neue Röntgenverfahren gestatten auf grund bestehender Nachbearbeitungsoptionen eine für andere medizinische Bereiche bereits nachgewiesene Strahlenreduzierung. Ziel der vorleigenden Studie ist es, sieben mit unterschiedlicher Dosierung (zwischen 5 und 150 mAs bei konstant 70 kV) hergestelle Fernröntgenseitenbilder eines Schädelphantoms kephalometrisch auszuwerten und die Ergebnisse der zehn Auswerter statistisch zu vergleichen Währen für die konventionellen Fernröntgenseitenbilder eine statistisch belegbare Uberlegenheit einzelner Belichtungsparameter für die sagittale und vertikale Lokalisierbarkeit von Referenzpunkten in Abhängigkeit von der Röntgenopazität der Strukturen gefunden wurde, ergab die Auswertung der mit der digitalen Lumineszenzradiographie hergesttellten Aufnahmen keine derartige Tendenz. Bei Anwendung der digitalen Lumineszenzradiographie im Gegensatz zu konventioneller Technik waren die Referenzpunkte in allen Aufnahmen deutlich sichtbar. Somit kommt die digitale Lumineszenzradiographie den klinischen Anforderungen einer Strahlenreduktion auf bis zu 20% der normalerweise verwandten Dosis bei erhaltener diagnostischer Aussagekraft entgegen.SummaryThanks to their capability for post-processing of image data, the digital radiological techniques introduced from 1970 onwards permit dose reduction with no loss of clinical information. The aim of this study was to establish the extent of possible dose reduction in orthodontic lateral cephalography. For this purpose, lateral cephalograms of a head phantom taken with varying radiation doses (5 to 150 mAs, constant 70 kV) were evaluated. The evaluations of ten judges were compared statistically. Conventional lateral cephalograms showed a statistically proven superiority of a number of exposure parameters for the sagital and vertical localisation of reference points. This correlated with the radiological density of the structures. In contrast to the conventional technique, the reference points in all images obtained by digital luminescence radiography showed no such tendency. Digital huminescence thus meets the clinical need to reduce radiation dose (to about 20% of the usual dose) while providing no less diagnostic information.


Journal of Orofacial Orthopedics-fortschritte Der Kieferorthopadie | 1991

Morphologische Ergebnisse zur Anwendbarkeit eines gepulsten Kryptonfluorid-Excimerlasers im Rahmen der Schmelzkonditionierung

Th. Ruppenthal; Udo Stratmann; M. Schürenberg; Daniel R. Czech; G. Wessling; H. G. Sergl

ZusammenfassungTrotz vieler Fortschritte auf dem Gebiet der Säure-Ätz-Technik sind wesentliche Probleme bisher nicht gelöst worden. Die Hauptaspekte dieses Problemkreises sind das nicht vorhersagbare Ätzmuster, die unkontrollierbare Langzeittiefenwirkung sowie die Entstehung von Schmelzausrissen aufgrund einer nicht definierbaren Bruchfläche bei Bracketabnahme. Ziel der vorliegenden Studie ist es, morphologische Ergebnisse der Schmelzkonditionierung bei Verwendung eines gepulsten Kryptonfluorid-Excimerlasers (248 nm) vorzustellen. Die rasterelektronenmikroskopische Untersuchung zeigte ein dem peripheren Säure-Ätz-Tup ähnelndes Oberflächenrelief. Zeichen einer Hitzeentwicklung wurden nicht gefunden. Die Anforderungen an ein modernes Lasersystem, das zu einer möglichen Alternative der konventionellen Säure-Ätz-Technik werden könnte, werden diskutiert.SummaryAlthough there have been many advances in the field of acid etching, major problems still present. For the most part, these are the unpredictability of the effects of etching, the lack of control of the depth of etching over the long term, and the development of enamel fractures occurring on debonding. The aim of this study was to investigate the morphological effects of enamel conditioning using a pulsed krypton fluoride excimer laser (wavelength 248 nm). Scanning electron microscopic examination revealed a surface similar to that produced by peripheral etching; no signs of thermal damage were to be seen. The requirements that have to be met by a modern laser considered as a possible alternative to conventional acid etching, are discussed.Although there have been many advances in the field of acid etching, major problems still present. For the most part, these are the unpredictability of the effects of etching, the lack of control of the depth of etching over the long term, and the development of enamel fractures occurring on debonding. The aim of this study was to investigate the morphological effects of enamel conditioning using a pulsed krypton fluoride excimer laser (wavelength 248 nm). Scanning electron microscopic examination revealed a surface similar to that produced by peripheral etching; no signs of thermal damage were to be seen. The requirements that have to be met by a modern laser considered as a possible alternative to conventional acid etching, are discussed.


Journal of Orofacial Orthopedics-fortschritte Der Kieferorthopadie | 1992

In-vitro-Studie der Interferenz von kieferorthopädischer Bebänderung und Füllungswerkstoffen

Michael A. Baumann; K. Samanek; Th. Ruppenthal

ZusammenfassungVerfärbungen und Auflagerungen an Bändern und Füllungen während Multibandbehandlung sind ein bekanntes klinisches Phänomen. Aufgrund der komplexen Ätiologie wurde in der vorliegenden Untersuchung ein In vitro-Modell gewählt. Ziel der Studie war es, einen Einblick in die Mengen der freigesetzten Ionen und die bevorzugten Metalle zu erhalten. Dazu wurden je 25 genormte MOD-Kavitäten an Frasaco-Zähnen mit einem Non-gamma-2-Amalgam (Amalcap plus, Vivadent) per Hand oder maschinell kondensiert. Zusätzlich wurden je zehn Kronen einer hochgoldhaltigen (Maingold SG, Heraeus) und einer Palladiumbasis-Legierung (Albabond A, Heraeus) bergestellt. Auf alle Proben wurden kieferorthopädische Bander (Dentaurum-Molarenband) mit Glasionomerzement befestigt (Ketac Cem, Espe) und für sieben Tage bei 37°C in einer 0,1 molaren Milchsäure-Kochsalz-Lösung gelagert. Mittels Ion-Coupled-Plasma-(ICP-)Analyse wurden die in der Korrosionslösung befindlichen Elemente analysiert. Es zeigten sich sehr hohe Al- und Zn-Konzentrationen, die auf die Auflösung der Betestigungszemente zurückzuführen sind. Aus den jeweiligen Füllungswerkstoffen wurden vor allein Ag, Sn oder Cu freigesetzt, während aus dem Band Fe, Cr, Ni und Ti stammten. In der Kombination Stahlband und Fühlungswerkstoff kam es in den meisten Fällen zu einer gesteigerten Ionenabgabe.SummaryDiscolouring and layers on bands and restorations during fixed orthodontic therapy are well known clinical phenomenon. Because of the complexity of etiological factors an in-vitro model was used in this study. Aim of the study was to examine the amounts and sort of metals which are dissolved. Therefore, respectively 25 normed MOD-cavities in Frasaco-teeth were filled with a non gamma-2-amalgam (Amalcap plus, Vivadent) and condensed manually or mechanically. In addition, ten crowns of a high golden (Maingold SG, Heraeus) as well as a palladium basis alloy (Albabond A, Heraens) were casted. Then they were banded with stainless steel bands (Dentaurum) and cemented with a glass ionomer cement (Ketac Cem, Espe). The probes were given into a 0,1 molar lactic acid for seven days at 37°C. Using ICP (ion coupled plasma) analysis the corrosion solution was examined for elements. High levels of Zn- and Al-ion contents were found, which are components of the used cements. The filling materials theirselves mainly set free small amounts of Ag, Sn or Cu. The steel band released Fe, Cr, Ni and Ti. The combination of filling material and band resulted in a higher release of most ions.Discoloring and layers on bands and restorations during fixed orthodontic therapy are well known clinical phenomenon. Because of the complexity of etiological factors an in-vitro model was used in this study. Aim of the study was to examine the amounts and sort of metals which are dissolved. Therefore, respectively 25 normed MOD-cavities in Frasaco-teeth were filled with a non-gamma-2-amalgam (Amalcap plus, Vivadent) and condensed manually or mechanically. In addition, ten crowns of a high golden (Maingold SG, Heraeus) as well as a palladium basis alloy (Albabond A, Heraeus) were casted. Then they were banded with stainless steel bands (Dentaurum) and cemented with a glass ionomer cement (Ketac Cem, Espe). The probes were given into a 0.1 molar lactic acid for seven days at 37 degrees C. Using ICP (ion coupled plasma) analysis the corrosion solution was examined for elements. High levels of Zn- and Al-ion contents were found, which are components of the used cements. The filling materials themselves mainly set free small amounts of Ag, Sn or Cu. The steel band released Fe, Cr, Ni and Ti. The combination of filling material and band resulted in a higher release of most ions.


Journal of Orofacial Orthopedics-fortschritte Der Kieferorthopadie | 1992

Element analytical and quantitative morphometric evaluation of adhesive remnants and enamel loss after debonding of metal brackets

Th. Ruppenthal; Udo Stratmann; H. G. Sergl; Daniel R. Czech


Journal of Orofacial Orthopedics-fortschritte Der Kieferorthopadie | 1992

Temperature increase in dental pulp during electrothermal debonding of ceramic brackets

Th. Ruppenthal; Michael A. Baumann


Journal of Orofacial Orthopedics-fortschritte Der Kieferorthopadie | 1992

Vergleichende Untersuchung zur Mglichkeit der Dosisreduzierung von Fernrntgenseitenaufnahmen

Th. Ruppenthal; Bradley L. Fricke; H. G. Sergl; Gerhard Michael Doll


Journal of Orofacial Orthopedics-fortschritte Der Kieferorthopadie | 1992

Comparative study on the possiblity of dose reduction in lateral cephalograms

Th. Ruppenthal; Bradley L. Fricke; H. G. Sergl; Gerhard Michael Doll


Journal of Orofacial Orthopedics-fortschritte Der Kieferorthopadie | 1992

In-vitro study of the interference of fixed orthodontic appliances and filling materials

Michael A. Baumann; K. Samanek; Th. Ruppenthal

Collaboration


Dive into the Th. Ruppenthal's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge