Thang Tat Nguyen
Hanyang University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Thang Tat Nguyen.
Annals of The Icrp | 2016
Yeon Soo Yeom; Thang Tat Nguyen; Zhao Jun Wang; Han Sung Kim; Min Cheol Han; Jai Ki Lee; M. Zankl; N. Petoussi-Henss; Wesley E. Bolch; Choonsik Lee; B.S. Chung
The International Commission on Radiological Protection (ICRP) reference male and female adult phantoms, described in Publication 110, are voxel phantoms based on whole-body computed tomography scans of a male and a female patient, respectively. The voxel in-plane resolution and the slice thickness, of the order of a few millimetres, are insufficient for proper segmentation of smaller tissues such as the lens of the eye, the skin, and the walls of some organs. The calculated doses for these tissues therefore present some limitations, particularly for weakly penetrating radiation. Similarly, the Publication 110 phantoms cannot represent 8–40-µm-thick target regions in respiratory or alimentary tract organs. Separate stylised models have been used to represent these tissues for calculation of the ICRP reference dose coefficients (DCs). ICRP Committee 2 recently initiated a research project, the ultimate goal of which is to convert the Publication 110 phantoms to a high-quality polygon-mesh (PM) format, including all source and target regions, even those of the 8–40-µm-thick alimentary and respiratory tract organs. It is expected that the converted phantoms would lead to the same or very similar DCs as the Publication 110 reference phantoms for penetrating radiation and, at the same time, provide more accurate DCs for weakly penetrating radiation and small tissues. Additionally, the reference phantoms in the PM format would be easily deformable and, as such, could serve as a starting point to create phantoms of various postures for use, for example, in accidental dose calculations. This paper will discuss the current progress of the phantom conversion project and its significance for ICRP DC calculations.
Physics in Medicine and Biology | 2015
Thang Tat Nguyen; Yeon Soo Yeom; Han Sung Kim; Zhao Jun Wang; Min Cheol Han; Jai Ki Lee; Maria Zankl; Nina Petoussi-Henss; Wesley E. Bolch; Choonsik Lee; Beom Sun Chung
The dose coefficients for the eye lens reported in ICRP 2010 Publication 116 were calculated using both a stylized model and the ICRP-110 reference phantoms, according to the type of radiation, energy, and irradiation geometry. To maintain consistency of lens dose assessment, in the present study we incorporated the ICRP-116 detailed eye model into the converted polygon-mesh (PM) version of the ICRP-110 reference phantoms. After the incorporation, the dose coefficients for the eye lens were calculated and compared with those of the ICRP-116 data. The results showed generally a good agreement between the newly calculated lens dose coefficients and the values of ICRP 2010 Publication 116. Significant differences were found for some irradiation cases due mainly to the use of different types of phantoms. Considering that the PM version of the ICRP-110 reference phantoms preserve the original topology of the ICRP-110 reference phantoms, it is believed that the PM version phantoms, along with the detailed eye model, provide more reliable and consistent dose coefficients for the eye lens.
Journal of Radiological Protection | 2016
Yeon Soo Yeom; Han Sung Kim; Thang Tat Nguyen; Chansoo Choi; Min Cheol Han; Jai Ki Lee; Maria Zankl; Nina Petoussi-Henss; Wesley E. Bolch; Choonsik Lee; Beom Sun Chung
When converting voxel phantoms to a surface format, the small intestine (SI), which is usually not accurately represented in a voxel phantom due to its complex and irregular shape on one hand and the limited voxel resolutions on the other, cannot be directly converted to a high-quality surface model. Currently, stylized pipe models are used instead, but they are strongly influenced by developers subjectivity, resulting in unacceptable geometric and dosimetric inconsistencies. In this paper, we propose a new method for the construction of SI models based on the Monte Carlo approach. In the present study, the proposed method was tested by constructing the SI model for the polygon-mesh version of the ICRP reference male phantom currently under development. We believe that the new SI model is anatomically more realistic than the stylized SI models. Furthermore, our simulation results show that the new SI model, for both external and internal photon exposures, leads to dose values that are more similar to those of the original ICRP male voxel phantom than does the previously constructed stylized SI model.
Physics in Medicine and Biology | 2017
Han Sung Kim; Yeon Soo Yeom; Thang Tat Nguyen; Chansoo Choi; Min Cheol Han; Jai Ki Lee; Maria Zankl; Nina Petoussi-Henss; Wesley E. Bolch; Choonsik Lee; Rui Qiu; Keith F. Eckerman; Beom Sun Chung
It is not feasible to define very small or complex organs and tissues in the current voxel-type adult reference computational phantoms of the International Commission on Radiological Protection (ICRP), which limit dose coefficients for weakly penetrating radiations. To address the problem, the ICRP is converting the voxel-type reference phantoms into mesh-type phantoms. In the present study, as a part of the conversion project, the micrometer-thick target and source regions in the alimentary and respiratory tract systems as described in ICRP Publications 100 and 66 were included in the mesh-type ICRP reference adult male and female phantoms. In addition, realistic lung airway models were simulated to represent the bronchial (BB) and bronchiolar (bb) regions. The electron specific absorbed fraction (SAF) values for the alimentary and respiratory tract systems were then calculated and compared with the values calculated with the stylized models of ICRP Publications 100 and 66. The comparisons show generally good agreement for the oral cavity, oesophagus, and BB, whereas for the stomach, small intestine, large intestine, extrathoracic region, and bb, there are some differences (e.g. up to ~9 times in the large intestine). The difference is mainly due to anatomical difference in these organs between the realistic mesh-type phantoms and the simplified stylized models. The new alimentary and respiratory tract models in the mesh-type ICRP reference phantoms preserve the topology and dimensions of the voxel-type ICRP phantoms and provide more reliable SAF values than the simplified models adopted in previous ICRP Publications.
Physics in Medicine and Biology | 2016
Yeon Soo Yeom; Zhao Jun Wang; Thang Tat Nguyen; Han Sung Kim; Chansoo Choi; Min Cheol Han; Jai Ki Lee; Beom Sun Chung; Maria Zankl; Nina Petoussi-Henss; Wesley E. Bolch; Choonsik Lee
The reference adult computational phantoms of the international commission on radiological protection (ICRP) described in Publication 110 are voxel-type computational phantoms based on whole-body computed tomography (CT) images of adult male and female patients. The voxel resolutions of these phantoms are in the order of a few millimeters and smaller tissues such as the eye lens, the skin, and the walls of some organs cannot be properly defined in the phantoms, resulting in limitations in dose coefficient calculations for weakly penetrating radiations. In order to address the limitations of the ICRP-110 phantoms, an ICRP Task Group has been recently formulated and the voxel phantoms are now being converted to a high-quality mesh format. As a part of the conversion project, in the present study, the skeleton models, one of the most important and complex organs of the body, were constructed. The constructed skeleton models were then tested by calculating red bone marrow (RBM) and endosteum dose coefficients (DCs) for broad parallel beams of photons and electrons and comparing the calculated values with those of the original ICRP-110 phantoms. The results show that for the photon exposures, there is a generally good agreement in the DCs between the mesh-type phantoms and the original voxel-type ICRP-110 phantoms; that is, the dose discrepancies were less than 7% in all cases except for the 0.03 MeV cases, for which the maximum difference was 14%. On the other hand, for the electron exposures (⩽4 MeV), the DCs of the mesh-type phantoms deviate from those of the ICRP-110 phantoms by up to ~1600 times at 0.03 MeV, which is indeed due to the improvement of the skeletal anatomy of the developed skeleton mesh models.
IEEE Transactions on Nuclear Science | 2016
Min Cheol Han; Jeong Min Seo; Se Hyung Lee; Yeon Soo Yeom; Thang Tat Nguyen; Chansoo Choi; Seonghoon Kim; Jong Hwi Jeong; Jason W. Sohn
We propose a new type of computational phantom, the “4D voxel phantom,” for realistic modeling of continuous respiratory motion in Monte Carlo dose calculation. In this phantom, continuous respiratory motion is realized by linear interpolation of the deformation vector fields (DVFs) between the neighboring original phases in the 4D CT data of a patient and by subsequent application of the DVFs to the phase images or to the reference image to produce multiple inter-phase images between the neighboring original phase images. A 4D voxel phantom is a combination of high-temporal-resolution voxel phantoms and on-the-fly dose registration to the reference phase image. In the course of particle transport simulation, the dose or deposited energy is directly registered to the reference phase image on-the-fly (i.e., after each event) using a DVF for dose registration. In the present study, we investigated two methods - DRP (DIR [deformable image registration] with respect to Reference Phase image) and DNP (DIR with respect to Neighboring original Phase image) - for production of multiple inter-phase images or high-temporal-resolution voxel phantoms. Utilizing these two methods, two 4D voxel phantoms each with 100 phases were produced from the original 10-phase images of the 4D CT data of a real patient in order to compare the two methods and to test the feasibility of the 4D voxel phantom methodology in general. We found that it is possible to produce a 4D voxel phantom very rapidly (i.e., <;40 min on a 4-core personal computer for a 100-phase phantom) in a fully automated process. The dose calculation results showed that the constructed 100-phase 4D voxel phantoms provide cumulative-dose distributions very similar to those of the conventional 10-phase approach for stationary proton-beam irradiation. The passing rates of the dose distributions of the 4D voxel phantoms were higher than 99.9% according to the 3% and 3 mm gamma criteria, which results validate the 4D voxel phantom methodology. The point-and dose-tracking analysis data showed that the DRP method, which uses the minimal number of DIR operations but uses inverse DVFs, provides significantly better results than those of the DNP method, which uses only DIR to generate the DVFs for inter-phase image generation and dose registration. The present study also showed that the computation time does not significantly increase when the number of phases in the 4D voxel phantom is increased for more realistic representation of continuous respiratory motion; the only significant increase is in the memory occupancy, which grows almost linearly with the number of phases.
Annals of The Icrp | 2018
Yeon Soo Yeom; Thang Tat Nguyen; Min Cheol Han; C. Choi; H. Lee; H. Han; B. Shin; J-K. Lee; H.S. Kim; M. Zankl; N. Petoussi-Henss; Wesley E. Bolch; C. Lee; B.S. Chung; R. Qiu; K. Eckerman
Committee 2 of the International Commission on Radiological Protection (ICRP) has constructed mesh-type adult reference computational phantoms by converting the voxel-type ICRP Publication 110 adult reference computational phantoms to a high-quality mesh format, and adding those tissues that were below the image resolution of the voxel phantoms and therefore not included in the Publication 110 phantoms. The new mesh phantoms include all the necessary source and target tissues for effective dose calculations, including the 8–40-µm-thick target layers of the alimentary and respiratory tract organs, thereby obviating the need for supplemental organ-specific stylised models (e.g. respiratory airways, alimentary tract organ walls and stem cell layers, lens of the eye, and skin basal layer). To see the impact of the new mesh-type reference phantoms, dose coefficients for some selected external and internal exposures were calculated and compared with the current reference values in ICRP Publications 116 and 133, which were calculated by employing the Publication 110 phantoms and the supplemental stylised models. The new mesh phantoms were also used to calculate dose coefficients for industrial radiography sources near the body, which can be used to estimate the organ doses of the worker who is accidentally exposed by an industrial radiography source; in these calculations, the mesh phantoms were deformed to reflect the size of the worker, and also to evaluate the effect of posture on dose coefficients.
Journal of the Korean Physical Society | 2016
Yeon Soo Yeom; Thang Tat Nguyen; Chansoo Choi; Min Cheol Han; Jong Hwi Jeong
Journal of Radiation Protection and Research | 2016
Min Cheol Han; Yeon Soo Yeom; Thang Tat Nguyen; Chansoo Choi; Hyun Su Lee
Journal of the Korean Physical Society | 2018
Yeon Soo Yeom; Haegin Han; Chansoo Choi; Thang Tat Nguyen; Hanjin Lee; Bangho Shin; Min Cheol Han