Traci L. Moran
Pacific Northwest National Laboratory
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Traci L. Moran.
Archive | 2010
Jeffrey W. Griffin; Traci L. Moran; Leonard J. Bond
This report summarizes a Radiation Source Replacement Workshop in Houston Texas on October 27-28, 2010, which provided a forum for industry and researchers to exchange information and to discuss the issues relating to replacement of AmBe, and potentially other isotope sources used in well logging.
Archive | 2012
Susan L. Crawford; Anthony D. Cinson; Matthew S. Prowant; Traci L. Moran; Michael T. Anderson
Two dissimilar metal weld (DMW) pipe-to-nozzle specimens were implanted with thermal fatigue cracks in the 13% to 90% through-wall depth range. The specimens were ultrasonically evaluated with phased-array probes having center frequencies of 0.8, 1.0, 1.5, and 2.0 megahertz (MHz). An Alloy 82/182 weld overlay (WOL) was applied and the specimens were ultrasonically re-evaluated for flaw detection and characterization. The Post-WOL flaw depths were approximately 10% to 56% through-wall. This study has shown the effectiveness of ultrasonic examinations of Alloy 82/182 overlaid DMW specimens. Phased-array probes with center frequency in the 0.8- to 1.0-MHz range provide a strong coherent signal but the greater ultrasonic wavelength and larger beam spot size prevent the reliable detection of small flaws. These small flaws had nominal through-wall depths of less than 15% and length in the 50-60 mm (2-2.4 in.) range. Flaws in the 19% and greater through-wall depth range were readily detected with all four probes. At the higher frequencies, the reflected signals are less coherent but still provide adequate signal for flaw detection and characterization. A single inspection at 2.0 MHz could provide adequate detection and sizing information but a supplemental inspection at 1.0 or 1.5 MHz is recommended.
Volume 5: High-Pressure Technology; ASME NDE Division; 22nd Scavuzzo Student Paper Symposium and Competition | 2014
Traci L. Moran; Michael T. Anderson; Anthony D. Cinson; Susan L. Crawford; Matthew S. Prowant; Carol A. Nove
The Pacific Northwest National Laboratory (PNNL) is conducting studies for the U.S. Nuclear Regulatory Commission (NRC) to assess the capability, effectiveness, and reliability of ultrasonic testing (UT) as a replacement method for radiographic testing (RT) for volumetric examination of nuclear power plant (NPP) components. This particular study focused on evaluating the use of UT on carbon steel plate welds. Welding fabrication flaws included a combination of planar and volumetric types, e.g., incomplete fusion, lack of penetration, cracks, porosity, and slag inclusions. The examinations were conducted using phased-array (PA) UT techniques applied primarily for detection and flaw type characterization. This paper will discuss the results of using UT in lieu of RT for detection and classification of fabrication flaws in carbon steel plate welds.
Archive | 2011
Leonard J. Bond; Jeffrey W. Griffin; Robert V. Harris; Kayte M. Denslow; Traci L. Moran
The focus of this study is the understanding of the technical obstacles that hinder the replacement of and the disadvantages from the loss of extensive interpretation experience based on data accumulated with AmBe. Enhanced acoustic and electromagnetic sensing methods in combination with non-isotope-based well logging techniques have the potential to complement and/or replace existing isotope-based techniques, providing the opportunity to reduce oil industry dependence on isotopic sources such as AmBe.
ASME 2011 Pressure Vessels and Piping Conference: Volume 5 | 2011
Susan L. Crawford; Anthony D. Cinson; Traci L. Moran; Matthew S. Prowant; Aaron A. Diaz; Michael T. Anderson
A set of circumferentially oriented thermal fatigue cracks (TFCs) were implanted into three cast austenitic stainless steel (CASS) pressurizer (PZR) surge-line specimen welds (pipe-to-elbow configuration) that were salvaged from a U.S. commercial nuclear power plant that had not been operated. Thus, these welds were fabricated using vintage CASS materials that were formed in the 1970s. Additionally, in-situ grown TFCs were placed in the adjacent CASS base material of one of these specimens. Ultrasonic phased-array responses from both types of flaws (implanted and in-situ grown) were analyzed for detection and characterization based on sizing and signal-to-noise determination. Multiple probes were employed covering the 0.8 to 2.0 MHz frequency range. To further validate the Pacific Northwest National Laboratory (PNNL) findings, an independent in-service inspection (ISI) supplier evaluated the flaws with their American Society of Mechanical Engineers (ASME) Code, Section XI, Appendix VIII-qualified procedure. The results obtained by PNNL personnel compared favorably to the ISI supplier results. All examined flaws were detected and sized within the ASME Code-allowable limits.Copyright
ASME 2010 Pressure Vessels and Piping Division/K-PVP Conference | 2010
Traci L. Moran; Pradeep Ramuhalli; Allan F. Pardini; Steven R. Doctor; Michael T. Anderson
The nuclear power industry has recently proposed using ultrasonic testing (UT) in lieu of radiographic testing (RT) on new construction welds and on the repairs of operating reactor component welds. Advantages of UT include a reduction in inspection time, costs, and plant personnel exposure to radiation fields. The replacement of one nondestructive testing method with another, however, requires a detailed analysis of the capabilities of the replacement method as compared to the existing method. Capabilities of interest in this context include detection reliability, false call rates, flaw characterization and sizing accuracy, human factors, data recording capabilities, and cost. The interchangeability of UT and RT has been studied by several institutions, but the evidence found to date in a literature search is not conclusive and therefore requires further investigation to assess the ability of UT to meet nuclear power industry fabrication and pre-service inspection standards. This paper reviews relevant literature on the interchangeability of UT and RT, and identifies potential gaps that may need to be addressed in this area.
ASME 2010 Pressure Vessels and Piping Division/K-PVP Conference | 2010
Aaron A. Diaz; Anthony D. Cinson; Susan L. Crawford; Traci L. Moran; Michael T. Anderson
A set of circumferentially oriented thermal fatigue cracks (TFCs) were implanted into three cast austenitic stainless steel (CASS) pressurizer (PZR) surge-line specimens (pipe-to-elbow welds) that were fabricated using vintage CASS materials formed in the 1970s, and flaw responses from these cracks were used to evaluate detection and sizing performance of the phased-array (PA) ultrasonic testing (UT) methods applied. Four different custom-made PA probes were employed in this study, operating nominally at 800 kHz, 1.0 MHz, 1.5 MHz, and 2.0 MHz center frequencies. The CASS PZR surge-line specimens were polished and chemically etched to bring out the microstructures of both pipe and elbow segments. Additional studies were conducted and documented to address baseline CASS material noise and observe possible ultrasonic beam redirection phenomena.Copyright
ASME 2010 Pressure Vessels and Piping Conference: Volume 6, Parts A and B | 2010
Susan L. Crawford; Steven R. Doctor; Anthony D. Cinson; Michael W. Watts; Traci L. Moran; Michael T. Anderson
Studies at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington, are being conducted to evaluate nondestructive examinations (NDE) coupled with mechanical testing of butt fusion joints in high density polyethylene (HDPE) pipe for assessing lack of fusion. The work provides information to the United States Nuclear Regulatory Commission (NRC) on the effectiveness of volumetric inspection techniques of HDPE butt fusion joints in Section III, Division 1, Class 3, buried piping systems in nuclear power plants. This paper describes results from preliminary assessments using ultrasonic and microwave nondestructive techniques and mechanical testing with the high speed tensile impact test and the bend test for determining joint integrity. A series of butt joints were fabricated in 3408, 12 inch (30.5 cm) IPS DR-11 HDPE material by varying the fusion parameters to create good joints and joints containing a range of lack of fusion conditions. Six of these butt joints were volumetrically examined with time of flight diffraction (TOFD), phased array (PA) ultrasound, and the Evisive microwave system. The outer diameter (OD) weld beads were removed for microwave evaluation and the pipes ultrasonically re-evaluated. In two of the six pipes both the outer and inner diameter (ID) weld beads were removed and the pipe joints re-evaluated. Several of the pipes were sectioned and the joints destructively evaluated with the following techniques: high speed tensile test, bend test, and focused immersion ultrasound on a joint section removed from the pipe coupled with slicing through the joint and examining the revealed surfaces. The fusion parameters, nondestructive, and destructive evaluation results will be correlated to validate the effectiveness of what each NDE technology detects and what each does not detect. This is an initial limited study which will aid in identifying key future work.Copyright
Archive | 2010
Pradeep Ramuhalli; Ryan M. Meyer; Anthony D. Cinson; Traci L. Moran; Matthew S. Prowant; Bruce E. Watson; Royce Mathews; Robert V. Harris; Aaron A. Diaz; Michael T. Anderson
Archive | 2010
Michael T. Anderson; Susan L. Crawford; Aaron A. Diaz; Traci L. Moran