Vasileios Lahanas
National and Kapodistrian University of Athens
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Vasileios Lahanas.
International Journal of Medical Robotics and Computer Assisted Surgery | 2013
Constantinos Loukas; Vasileios Lahanas; Evangelos Georgiou
Despite the popular use of virtual and physical reality simulators in laparoscopic training, the educational potential of augmented reality (AR) has not received much attention. A major challenge is the robust tracking and three‐dimensional (3D) pose estimation of the endoscopic instrument, which are essential for achieving interaction with the virtual world and for realistic rendering when the virtual scene is occluded by the instrument. In this paper we propose a method that addresses these issues, based solely on visual information obtained from the endoscopic camera.
Surgical Endoscopy and Other Interventional Techniques | 2015
Vasileios Lahanas; Constantinos Loukas; Nikolaos Smailis; Evangelos Georgiou
IntroductionOver the past decade, simulation-based training has come to the foreground as an efficient method for training and assessment of surgical skills in minimal invasive surgery. Box-trainers and virtual reality (VR) simulators have been introduced in the teaching curricula and have substituted to some extent the traditional model of training based on animals or cadavers. Augmented reality (AR) is a new technology that allows blending of VR elements and real objects within a real-world scene. In this paper, we present a novel AR simulator for assessment of basic laparoscopic skills.MethodsThe components of the proposed system include: a box-trainer, a camera and a set of laparoscopic tools equipped with custom-made sensors that allow interaction with VR training elements. Three AR tasks were developed, focusing on basic skills such as perception of depth of field, hand-eye coordination and bimanual operation. The construct validity of the system was evaluated via a comparison between two experience groups: novices with no experience in laparoscopic surgery and experienced surgeons. The observed metrics included task execution time, tool pathlength and two task-specific errors. The study also included a feedback questionnaire requiring participants to evaluate the face-validity of the system.ResultsBetween-group comparison demonstrated highly significant differences (<0.01) in all performance metrics and tasks denoting the simulator’s construct validity. Qualitative analysis on the instruments’ trajectories highlighted differences between novices and experts regarding smoothness and economy of motion. Subjects’ ratings on the feedback questionnaire highlighted the face-validity of the training system.ConclusionsThe results highlight the potential of the proposed simulator to discriminate groups with different expertise providing a proof of concept for the potential use of AR as a core technology for laparoscopic simulation training.
Journal of Applied Clinical Medical Physics | 2015
Evaggelos Pantelis; Vassiliki Peppa; Vasileios Lahanas; E. Pappas; P. Papagiannis
This work presents BrachyGuide, a brachytherapy‐dedicated software tool for the automatic preparation of input files for Monte Carlo simulation from treatment plans exported in DICOM RT format, and results of calculations performed for its benchmarking. Three plans were prepared using two computational models, the image series of a water sphere and a multicatheter breast brachytherapy patient, for each of two commercially available treatment planning systems: BrachyVision and Oncentra Brachy. One plan involved a single source dwell position of an 192Ir HDR source (VS2000 or mHDR‐v2) at the center of the water sphere using the TG43 algorithm, and the other two corresponded to the TG43 and advanced dose calculation algorithm for the multicatheter breast brachytherapy patient. Monte Carlo input files were prepared using BrachyGuide and simulations were performed with MCNP v.6.1. For the TG43 patient plans, the Monte Carlo computational model was manually edited in the prepared input files to resemble TG43 dosimetry assumptions. Hence all DICOM RT dose exports were equivalent to corresponding simulation results and their comparison was used for benchmarking the use of BrachyGuide. Monte Carlo simulation results and corresponding DICOM RT dose exports agree within type A uncertainties in the majority of points in the computational models. Treatment planning system, algorithm, and source specific differences greater than type A uncertainties were also observed, but these were explained by treatment planning system‐related issues and other sources of type B uncertainty. These differences have to be taken into account in commissioning procedures of brachytherapy dosimetry algorithms. BrachyGuide is accurate and effective for use in the preparation of commissioning tests for new brachytherapy dosimetry algorithms as a user‐oriented commissioning tool and the expedition of retrospective patient cohort studies of dosimetry planning. PACS numbers: 87.53.Bn, 87.53.Jw, 87.55.D‐, 87.55.Qr, 87.55.km, 87.55.K‐
Brachytherapy | 2016
Vasiliki Peppa; Evaggelos Pantelis; E. Pappas; Vasileios Lahanas; Constantinos Loukas; P. Papagiannis
PURPOSE To develop a user-oriented procedure for testing treatment planning system (TPS) dosimetry in high-dose-rate brachytherapy, with particular focus to TPSs using model-based dose calculation algorithms (MBDCAs). METHODS AND MATERIALS Identical plans were prepared for three computational models using two commercially available systems and the same (192)Ir source. Reference dose distributions were obtained for each plan using the MCNP v.6.1 Monte Carlo (MC) simulation code with input files prepared via automatic parsing of plan information using a custom software tool. The same tool was used for the comparison of reference dose distributions with corresponding MBDCA exports. RESULTS The single source test case yielded differences due to the MBDCA spatial discretization settings. These affect points at relatively increased distance from the source, and they are abated in test cases with multiple source dwells. Differences beyond MC Type A uncertainty were also observed very close to the source(s), close to the test geometry boundaries, and within heterogeneities. Both MBDCAs studied were found equivalent to MC within 5 cm from the target volume for a clinical breast brachytherapy test case. These are in agreement with previous findings of MBDCA benchmarking in the literature. CONCLUSIONS The data and the tools presented in this work, that are freely available via the web, can serve as a benchmark for advanced clinical users developing their own tests, a complete commissioning procedure for new adopters of currently available TPSs using MBDCAs, a quality assurance testing tool for future updates of already installed TPSs, or as an admission prerequisite in multicentric clinical trials.
international conference on digital signal processing | 2011
Vasileios Lahanas; Constantinos Loukas; Nikolaos Nikiteas; Dimitrios Dimitroulis; Evangelos Georgiou
The aim of this paper was to investigate the potential role of augmented reality (AR) in the assessment of psychomotor skills in laparoscopic surgery. A basic AR task was developed using the ARToolkitPlus. The simulation models (virtual spheres) were embedded in a conventional laparoscopic box trainer. An ARToolkitPlus marker was attached to a laparoscopic instrument for extracting its trajectory. Two different groups were recruited to perform the task: novices and experts. Hidden Markov Models (HMMs) and Dynamic Time Warping (DTW) were used to evaluate the surgical maneuvers. The results show the strength of the proposed approach for proficiency assessment based on the quality of surgical maneuvers performed in the AR environment.
Surgical Endoscopy and Other Interventional Techniques | 2017
Vasileios Lahanas; Constantinos Loukas; Konstantinos Georgiou; Hani Lababidi; Dania Al-Jaroudi
BackgroundThe majority of the current surgical simulators employ specialized sensory equipment for instrument tracking. The Leap Motion controller is a new device able to track linear objects with sub-millimeter accuracy. The aim of this study was to investigate the potential of a virtual reality (VR) simulator for assessment of basic laparoscopic skills, based on the low-cost Leap Motion controller.MethodsA simple interface was constructed to simulate the insertion point of the instruments into the abdominal cavity. The controller provided information about the position and orientation of the instruments. Custom tools were constructed to simulate the laparoscopic setup. Three basic VR tasks were developed: camera navigation (CN), instrument navigation (IN), and bimanual operation (BO). The experiments were carried out in two simulation centers: MPLSC (Athens, Greece) and CRESENT (Riyadh, Kingdom of Saudi Arabia). Two groups of surgeons (28 experts and 21 novices) participated in the study by performing the VR tasks. Skills assessment metrics included time, pathlength, and two task-specific errors. The face validity of the training scenarios was also investigated via a questionnaire completed by the participants.ResultsExpert surgeons significantly outperformed novices in all assessment metrics for IN and BO (p < 0.05). For CN, a significant difference was found in one error metric (p < 0.05). The greatest difference between the performances of the two groups occurred for BO. Qualitative analysis of the instrument trajectory revealed that experts performed more delicate movements compared to novices. Subjects’ ratings on the feedback questionnaire highlighted the training value of the system.ConclusionsThis study provides evidence regarding the potential use of the Leap Motion controller for assessment of basic laparoscopic skills. The proposed system allowed the evaluation of dexterity of the hand movements. Future work will involve comparison studies with validated simulators and development of advanced training scenarios on current Leap Motion controller.
Surgical Innovation | 2015
Constantinos Loukas; Vasileios Lahanas; Meletios A. Kanakis; Evangelos Georgiou
The aim of this study was to assess whether mixed practice of basic tasks on a virtual reality (VR) simulator improves the performance of advanced tasks on the same device used for training as well as on a video trainer (VT). Thirty-six novices were allocated into 3 equal groups. Each group practiced on different combinations of basic tasks on a VR simulator: (A) peg transfer, (B) peg transfer and clipping, and (C) peg transfer, clipping, and cutting. Before and after training, each group performed a laparoscopic cholecystectomy (LC) scenario on the simulator and intracorporeal knot tying (KT) on a VT. Assessment metrics included time, instrument’s path length, penalty score, and hand motion synchronization. Results showed that for the common training tasks, plateau values were statistically equivalent for most assessment metrics (P > .05). For LC, all groups showed significant performance improvement (P < .05). For KT, group C improved significantly in pathlength (P < .005), penalty score (P < .05), and hand motion synchronization (P < .05); the other groups failed to show an improvement (P > .05). In conclusion, training on different VR tasks seems to have no effect on the performance of more demanding tasks on the same device. However, the number of different tasks practiced on the VR simulator seems to favorably affect the performance of advanced tasks on the VT.
Surgical Endoscopy and Other Interventional Techniques | 2016
Vasileios Lahanas; Constantinos Loukas; Evangelos Georgiou
AbstractIntroductionThe aim of this study was to describe a simple and easy-to-use calibration method that is able to estimate the pose (tip position and orientation) of a rigid endoscopic instrument with respect to an electromagnetic tracking device attached to the handle.MethodsA two-step calibration protocol was developed. First, the orientation of the instrument shaft is derived by performing a 360° rotation of the instrument around its shaft using a firmly positioned surgical trocar. Second, the 3D position of the instrument tip is obtained by allowing the tip to come in contact with a planar surface. ResultsThe results indicate submillimeter accuracy in the estimation of the tooltip position, and subdegree accuracy in the estimation of the shaft orientation, both with respect to a known reference frame. The assets of the proposed method are also highlighted by illustrating an indicative application in the field of augmented reality simulation.ConclusionsThe proposed method is simple, inexpensive, does not require employment of special calibration frames, and has potential applications not only in training systems but also in the operating room.
Medical Physics | 2015
Vasiliki Peppa; E. Pappas; Vasileios Lahanas; E. Pantelis; P. Papagiannis
Purpose: To develop user-oriented tools for commissioning and dosimetry testing of 192Ir brachytherapy treatment planning systems (TPSs) employing model based dose calculation algorithms (MBDCAs). Methods: A software tool (BrachyGuide) has been developed for the automatic generation of MCNP6 input files from any CT based plan exported in DICOM RT format from Elekta and Varian TPSs. BrachyGuide also facilitates the evaluation of imported Monte Carlo (MC) and TPS dose distributions in terms of % dose differences and gamma index (CT overlaid colormaps or relative frequency plots) as well as DVHs and related indices. For users not equipped to perform MC, a set of computational models was prepared in DICOM format, accompanied by treatment plans and corresponding MCNP6 generated reference data. BrachyGuide can then be used to compare institutional and reference data as per TG186. The model set includes a water sphere with the MBDCA WG 192 Ir source placed centrically and in two eccentric positions, a water sphere with cubic bone and lung inhomogeneities and a five source dwells plan, and a patient equivalent model with an Accelerated Partial Breast Irradiation (APBI) plan. Results: The tools developed were used for the dosimetry testing of the Acuros and ACE MBDCAs implemented in BrachyVision v.13 and Oncentra Brachy v.4.5, respectively. Findings were consistent with previous results in the literature. Besides points close to the source dwells, Acuros was found to agree within type A uncertainties with the reference MC results. Differences greater than MC type A uncertainty were observed for ACE at distances >5cm from the source dwells and in bone. Conclusion: The tools developed are efficient for brachytherapy MBDCA planning commissioning and testing. Since they are appropriate for distribution over the web, they will be put at the AAPM WG MBDCA’s disposal. Research co-financed by the ESF and Greek funds. NSRF operational Program: Education and Lifelong Learning Investing in Knowledge Society-Aristeia. Varian Medical Systems and Nucletron, an Elekta company provided access to TPSs for research purposes. Miss Peppa was supported by IKY-fellowships of excellence for postgraduate studies in Greece,Siemens Program.
Journal of Contemporary Brachytherapy | 2018
Irina Fotina; K. Zourari; Vasileios Lahanas; Evaggelos Pantelis; P. Papagiannis
Purpose To perform a comparative study of heterogeneities and finite patient dimension effects in 60Co and 192Ir high-dose-rate (HDR) brachytherapy. Material and methods Clinically equivalent plans were prepared for 19 cases (8 breast, 5 esophagus, 6 gynecologic) using the Ir2.A85-2 and the Co0.A86 HDR sources, with a TG-43 based treatment planning system (TPS). Phase space files were obtained for the two source designs using MCNP6, and validated through comparison to a single source dosimetry results in the literature. Dose to water, taking into account the patient specific anatomy and materials (Dw,m), was calculated for all plans using MCNP6, with input files prepared using the BrachyGuide software tool to analyze information from DICOM RT plan exports. Results A general TG-43 dose overestimation was observed, except for the lungs, with a greater magnitude for 192Ir. The distribution of percentage differences between TG-43 and Monte Carlo (MC) in dose volume histogram (DVH) indices for the planning target volume (PTV) presented small median values (about 2%) for both 60Co and 192Ir, with a greater dispersion for 192Ir. Regarding the organs at risk (OARs), median percentage differences for breast V50% were 3% (5%) for 60Co (192Ir). Differences in median skin D2cc were found comparable, with a larger dispersion for 192Ir, and the same applied to the lung D10cc and the aorta D2cc. TG-43 overestimates D2cc for the rectum and the sigmoid, with median differences from MC within 2% and a greater dispersion for 192Ir. For the bladder, the median of the difference is greater for 60Co (~2%) than for 192Ir (~0.75%), demonstrating however a greater dispersion again for 192Ir. Conclusions The magnitude of differences observed between TG-43 based and MC dosimetry and their smaller dispersion relative to 192Ir, suggest that 60Co HDR sources are more amenable to the TG-43 assumptions in clinical treatment planning dosimetry.