Wenjing Kang
University of Cincinnati
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Wenjing Kang.
Electroanalysis | 2013
Preetha Jothimuthu; Robert A. Wilson; Josi Herren; Xing Pei; Wenjing Kang; Rodney C. Daniels; Hector R. Wong; Fred R. Beyette; William R. Heineman; Ian Papautsky
Zinc (Zn) homeostasis is required for a functional immune system. Critically ill patients often exhibit decreased Zn serum concentrations and could potentially benefit from Zn supplementation as a therapeutic strategy. However, the conventional approaches to monitoring Zn are time consuming and costly. This work reports on detection of Zn by anodic stripping voltammetry (ASV) on bismuth electrodes in a microfabricated electrochemical cell. The working potential window of the electrodeposited bismuth film electrode was investigated by cyclic voltammetry, while square wave ASV was used for measuring Zn in acetate buffer and blood serum. Conditions critical to sensing, such as preconcentration potential, preconcentration time, and buffer pH, were optimized for Zn detection. The sensor was successfully calibrated with pH 6 acetate buffer in the physiologically-relevant range of 5 μM to 50μM Zn and exhibited well-defined and highly repeatable peaks. The sensor was used to demonstrate measurement of Zn in blood serum digested in HCl. The results of this work show that Zn detection in serum is possible with smaller sample volumes (μL vs. μL) and faster turnaround time (hours vs. days) as compared with the conventional spectroscopic methods.
Analytical Chemistry | 2014
Xing Pei; Wenjing Kang; Wei Yue; Adam Bange; William R. Heineman; Ian Papautsky
In this work, we report the first copper-based point-of-care sensor for electrochemical measurements demonstrated by zinc determination in blood serum. Heavy metals require careful monitoring, yet current methods are too complex for a point-of-care system. Electrochemistry offers a simple approach to metal detection on the microscale, but traditional carbon, gold (Au), or platinum (Pt) electrodes are difficult or expensive to microfabricate, preventing widespread use. Our sensor features a new low-cost electrode material, copper, which offers simple fabrication and compatibility with microfabrication and PCB processing, while maintaining competitive performance in electrochemical detection. Anodic stripping voltammetry of zinc using our new copper-based sensors exhibited a 140 nM (9.0 ppb) limit of detection (calculated) and sensitivity greater than 1 μA/μM in the acetate buffer. The sensor was also able to determine zinc in a bovine serum extract, and the results were verified with independent sensor measurements. These results demonstrate the advantageous qualities of this lab-on-a-chip electrochemical sensor for clinical applications, which include a small sample volume (μL scale), reduced cost, short response time, and high accuracy at low concentrations of analyte.
Analytical Chemistry | 2017
Wenjing Kang; Xing Pei; Cory A. Rusinek; Adam Bange; Erin N. Haynes; William R. Heineman; Ian Papautsky
This work demonstrates determination of lead (Pb) in surface water samples using a low-cost copper (Cu)-based electrochemical sensor. Heavy metals require careful monitoring due to their toxicity, yet current methods are too complex or bulky for point-of-care (POC) use. Electrochemistry offers a convenient alternative for metal determination, but the traditional electrodes, such as carbon or gold/platinum, are costly and difficult to microfabricate. Our copper-based sensor features a low-cost electrode material-copper-that offers simple fabrication and competitive performance in electrochemical detection. For anodic stripping voltammetry (ASV) of Pb, our sensor shows 21 nM (4.4 ppb) limit of detection, resistance to interfering metals such as cadmium (Cd) and zinc (Zn), and stable response in natural water samples with minimum sample pretreatment. These results suggest this electrochemical sensor is suitable for environmental and potentially biological applications, where accurate and rapid, yet inexpensive, on-site monitoring is necessary.
Analytical Chemistry | 2016
Cory A. Rusinek; Adam Bange; Mercedes Warren; Wenjing Kang; Keaton Nahan; Ian Papautsky; William R. Heineman
Though an essential metal in the body, manganese (Mn) has a number of health implications when found in excess that are magnified by chronic exposure. These health complications include neurotoxicity, memory loss, infertility in males, and development of a neurologic psychiatric disorder, manganism. Thus, trace detection in environmental samples is increasingly important. Few electrode materials are able to reach the negative reductive potential of Mn required for anodic stripping voltammetry (ASV), so cathodic stripping voltammetry (CSV) has been shown to be a viable alternative. We demonstrate Mn CSV using an indium tin oxide (ITO) working electrode both bare and coated with a sulfonated charge selective polymer film, polystyrene-block-poly(ethylene-ran-butylene)-block-polystyrene-sulfonate (SSEBS). ITO itself proved to be an excellent electrode material for Mn CSV, achieving a calculated detection limit of 5 nM (0.3 ppb) with a deposition time of 3 min. Coating the ITO with the SSEBS polymer was found to increase the sensitivity and lower the detection limit to 1 nM (0.06 ppb). This polymer modified electrode offers excellent selectivity for Mn as no interferences were observed from other metal ions tested (Zn(2+), Cd(2+), Pb(2+), In(3+), Sb(3+), Al(3+), Ba(2+), Co(2+), Cu(2+), Ni(3+), Bi(3+), and Sn(2+)) except Fe(2+), which was found to interfere with the analytical signal for Mn(2+) at a ratio 20:1 (Fe(2+)/Mn(2+)). The applicability of this procedure to the analysis of tap, river, and pond water samples was demonstrated. This simple, sensitive analytical method using ITO and SSEBS-ITO could be applied to a number of electroactive transition metals detectable by CSV.
Analytical Chemistry | 2014
Wenjing Kang; Xing Pei; Adam Bange; Erin N. Haynes; William R. Heineman; Ian Papautsky
In this work, we report on the development of a palladium-based, microfabricated point-of-care electrochemical sensor for the determination of manganese using square wave cathodic stripping voltammetry. Heavy metals require careful monitoring, yet current methods are too complex for a point-of-care system. Voltammetry offers an attractive approach to metal detection on the microscale, but traditional carbon, gold, or platinum electrodes are difficult or expensive to microfabricate, preventing widespread use. Our sensor uses palladium working and auxiliary electrodes and integrates them with a copper-based reference electrode for simple fabrication and compatibility with microfabrication and printed circuit board processing, while maintaining competitive performance in electrochemical detection. Copper electrodes were prepared on glass substrate using a combination of microfabrication procedures followed by electrodeposition of palladium. The disposable sensor system was formed by bonding a poly(dimethylsiloxane) (PDMS) well to the glass substrate. Cathodic stripping voltammetry of manganese using our new disposable palladium-based sensors exhibited 334 nM (18.3 ppb) limit of detection in borate buffer. The sensor was used to demonstrate manganese determination in natural water samples from a pond in Burnet Woods, located in Cincinnati, OH, and the Ohio River.
Microfluidics, BioMEMS, and Medical Microsystems X | 2012
Xing Pei; Wenjing Kang; Wei Yue; Adam Bange; Hector R. Wong; William R. Heineman; Ian Papautsky
This work reports on continuing development of a lab-on-a-chip sensor for electrochemical detection of heavy metal zinc in blood serum. The sensor consists of a three electrode system, including an environmentally-friendly bismuth working electrode, a Ag/AgCl reference electrode, and a gold auxiliary electrode. By optimizing the electrodeposition of bismuth film, better control of fabrication steps and improving interface between the sensor and potentiostat, repeatability and sensitivity of the lab-on-a-chip sensor has been improved. Through optimization of electrolyte and stripping voltammetry parameters, limits of detection were greatly improved. The optimized sensor was able to measure zinc in in the physiological range of 65-95 μg/dL. Ultimately, with further development and integrated sample preparation sensor system will permit rapid (min) measurements of zinc from a sub-mL sample (a few drops of blood) for bedside monitoring.
Electroanalysis | 2013
Wenjing Kang; Xing Pei; Wei Yue; Adam Bange; William R. Heineman; Ian Papautsky
Journal of The Electrochemical Society | 2014
Xing Pei; Wenjing Kang; Wei Yue; Adam Bange; William R. Heineman; Ian Papautsky
Electroanalysis | 2017
Cory A. Rusinek; Wenjing Kang; Keaton Nahan; Megan Hawkins; Cooper Quartermaine; Angela Stastny; Adam Bange; Ian Papautsky; William R. Heineman
Electroanalysis | 2017
Wenjing Kang; Cory A. Rusinek; Adam Bange; Erin N. Haynes; William R. Heineman; Ian Papautsky