Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Won Jong Yoo is active.

Publication


Featured researches published by Won Jong Yoo.


Skeletal Radiology | 2011

Emphasis on the MR imaging findings of brown tumor: a report of five cases

Won Sun Hong; Mi Sook Sung; Kyung-Ah Chun; Jee-Young Kim; Sun-Won Park; Kee-Haeng Lee; Hyun Wook Lim; Yeon Soo Lim; Won Jong Yoo; Myung Hee Chung

ObjectiveBrown tumors are focal reactive osteolytic lesions that are encountered in patients with primary or secondary hyperparathyroidism, and these tumors have nonspecific magnetic resonance (MR) imaging findings. However, there are only a few reports on MR imaging of brown tumors. The purpose of this study is to describe the spectrum of MR imaging findings of brown tumors.Materials and methodsThe MR imaging features of five patients with clinical and pathological evidence of brown tumor were retrospectively reviewed by two radiologists. The patients had primary hyperparathyroidism, which was confirmed as parathyroid adenoma (n = 2) and parathyroid carcinoma (n = 3). The MR images were evaluated for the presence of solid or cystic portions, the signal intensity of the lesions, the contrast enhancement pattern and the presence of cortex destruction and fluid-fluid levels.ResultsTwelve bone lesions were detected on the MR images of five patients; three lesions in two patients, four lesions in one patient, and one lesion in two patients. The tumor was solid in three lesions, mixed solid and cystic in four, and cystic in five. All the solid lesions were accompanied by mixed lesions. Discontinuity of the cortex and adjacent soft-tissue enhancement were seen in all the solid lesions. Fluid-fluid levels were seen in two cases within the cystic component of the mixed lesions and cystic lesions.ConclusionsThe five patients with brown tumor demonstrated a wide spectrum of MR imaging findings. There are few lesions that are osteolytic on the radiographs and that show a short T2 on MR imaging, such as brown tumor. Multiple cystic or mixed lesions are the expected findings of brown tumors.


Korean Journal of Radiology | 2007

Polyvinyl alcohol embolization adjuvant to oily chemoembolization in advanced hepatocellular carcinoma with arterioportal shunts.

Yeo Ju Kim; Hae Giu Lee; Jeong Mi Park; Yeon Soo Lim; Myung Hee Chung; Mi Sook Sung; Won Jong Yoo; Hyun Wook Lim

Objective To assess the feasibility and safety of polyvinyl alcohol (PVA) embolization adjuvant to transarterial oily chemoembolization (P-TACE) in advanced hepatocellular carcinoma (HCC) with arterioportal shunts (APS). Materials and Methods Nineteen patients who underwent PVA embolization for APS before a routine chemoembolization (TACE) procedure were retrospectively reviewed. 10 of these 19 patients underwent follow-up TACE or P-TACE after P-TACE (Group A), but nine patients underwent only initial P-TACE because of progression of HCC and/or underlying liver cirrhosis (Group B). Hepatic function tests, APS grades, and portal flow directions were evaluated before and after P-TACE sessions. Complications after procedures and survival days were also evaluated. Results In group A, APS grade was improved in eight patients and five of six patients with hepatofugal flow showed restored hepatopetal flow postoperatively. No immediate complication was developed in either group. Transient hepatic insufficiency developed in eight (42.1%) of 19 patients after P-TACE, and seven (87.5%) of these eight recovered within two weeks under conservative care. The mean and median survival time all study subjects was 280 days and 162 days. Conclusion P-TACE is feasible and safe in advanced HCC patients with APS.


Acta Radiologica | 2012

Evaluation of middle cerebral artery stents using multidetector row CT angiography in vivo study: comparison of the three different kernels

Jin Hee Jang; Yeon Soo Lim; Youn Joo Lee; Won Jong Yoo; Mi Sook Sung; Bum Soo Kim

Background There are very few reports assessing middle cerebral artery (MCA) stents using multidetector computed tomography (MDCT). Purpose To assess MCA stents using multidetector CT angiography (CTA) in vivo evaluation: the differences in the CTA results according to the three different kernels. Material and Methods We retrospectively evaluated 27 MCA stents from 26 patients who underwent CTA with 16- and 64-slice MDCT after percutaneous transluminal angioplasty and stenting (PTAS). By CTA, using medium-smooth kernel (B30), medium-sharp kernel (B50), and sharp kernel (B60), the lumen diameter, artificial luminal narrowing (ALN), and subjective visibility score of the stented vessels were evaluated. The subjective visibility score ranged from 1 (poor quality) to 5 (excellent) using a five-point scale. Results There were excellent inter-observer agreements for the lumen diameter measurements (P < 0.001). The mean diameter of the stented vessels was 2.10 ± 0.31 mm on digital subtraction angiography (DSA), 0.93 ± 0.20 mm on CTA using B30, 1.18 ± 0.27 mm on CTA using B50, and 1.29 ± 0.29 mm on CTA using B60. The mean ALN was 55.7 ± 6.0% on CTA using B30, 43.8 ±7.5% on CTA using B50, and 38.7 ± 8.3% on CTA using B60. CTA with higher kernels had a smaller ALN than images with smaller kernels. The median subjective visibility score on the CTA using B50 was 3, which was higher than for the other kernels. The differences in the lumen diameter, ALN, and the subjective visibility score of the stented vessels on CTA using the three different kernels was statistically significant (P < 0.001). Conclusion The sharp kernel was better to assess the lumen diameter and ALN, but was inferior to the medium-sharp kernel for in-stent evaluation due to high image-to-noise. CTA with medium-sharp kernel showed good lumen visibility and acceptable ALN for MCA stents. This could therefore be a non-invasive, readily applicable clinical method for assessing MCA stent patency after stent placement.


Korean Journal of Radiology | 2002

Retroperitoneal malignant mesenchymoma: a case of mesenchymal mixed tumor with osteosarcoma, leiomyosarcoma, liposarcoma and fibrosarcoma.

Jung Eun Choi; Hong Jun Chung; Won Jong Yoo; Myung Hee Chung; Mi Sook Sung; Hae Giu Lee; Il Young Park; Jeana Kim

Malignant mesenchymoma is an interesting but very rare tumor in which malignant differentiation has occurred twice or more. We report a case of retroperitoneal malignant mesenchymoma consisting of osteosarcoma, leiomyosarcoma, liposarcoma and fibrosarcoma. Abdominal CT showed a large retroperitoneal mass with two separate and distinct parts, namely an area of prominent calcification and one of clearly enhancing solid components. The mass contained histologically distinct tumorous components with no histologic admixure at the interfaces. The densely calcified nodule corresponded to osteosarcoma, and the non-calcified clearly enhancing nodules to leiomyosarcoma, liposarcoma and fibrosarcoma.


Acta Radiologica | 2014

Diagnostic accuracy of 64-slice multidetector CT angiography for detection of in-stent restenosis of vertebral artery ostium stents: comparison with conventional angiography.

Youn Joo Lee; Yeon Soo Lim; Hyun Wook Lim; Won Jong Yoo; Byung Gil Choi; Bum Soo Kim

Background There are very few reports assessing in-stent restenosis (ISR) after vertebral artery ostium (VAO) stents using multidetector computed tomography (MDCT). Purpose To compare the diagnostic accuracy of computed tomography angiography (CTA) using 64-slice MDCT with digital subtraction angiography (DSA) for detection of significant ISR after VAO stenting. Material and Methods The study evaluated 57 VAO stents in 57 patients (39 men, 18 women; mean age 64 years [range, 48–90 years]). All stents were scanned with a 64-slice MDCT scanner. Three sets of images were reconstructed with three different convolution kernels. Two observers who were blinded to the results of DSA assessed the diagnostic accuracy of CTA for detecting significant ISR (≥50% diameter narrowing) of VAO stents in comparison with DSA as the reference standard. The sensitivity, specificity, positive and negative predictive values, and accuracy were calculated. Results Of the 57 stents, 46 (81%) were assessable using CTA, while 11 (19%) were not. No stents with diameters ≤2.75 mm were assessable. DSA revealed 13 cases of significant ISR in all stents. The respective sensitivity, specificity, positive and negative predictive values, and accuracy were 92%, 82%, 60%, 97%, and 84% for all stents. On excluding the 11 non-assessable stents, the respective values were 88%, 95%, 78%, 97%, and 93%. Of the 46 CTA assessable stents, eight significant ISRs were diagnosed on DSA. Seven of eight patients with significant ISR by DSA were diagnosed correctly with CTA. The area under the receiver-operating characteristic curve (AUC) was 0.87 for all stents and 0.91 for assessable stents, indicating good to excellent agreement between CTA and DSA for detecting significant ISR after VAO stenting. Conclusion Sixty-four-slice MDCT is a promising non-invasive method of assessing stent patency and can exclude significant ISR with high diagnostic values after VAO stenting.


Journal of Computer Assisted Tomography | 2013

In vivo evaluation of carotid artery stents using multi-detector-row computed tomography angiography: comparison of 3 kernels.

Youn Joo Lee; Yeon Soo Lim; Na Young Jung; Won Jong Yoo; Mi Sook Sung; Myung Hee Chung; Bum Soo Kim

Objective The objective of this study was to assess the lumen visibility of carotid artery stents using multi–detector-row computed tomography (MDCT) angiography; compare medium-smooth, medium-sharp, and sharp kernels; and correlate these results to those of digital subtraction angiography (DSA). Methods We retrospectively evaluated 52 stents from 51 patients who underwent 16- and 64-slice MDCT angiography. Lumen diameters were measured 3 times by 2 neuroradiologists, and artificial luminal narrowing was calculated. To assess detection of in-stent restenosis (>50%), 2 neuroradiologists evaluated all MDCT and DSA images. Results Excellent intraobserver and interobserver agreements were obtained for the lumen diameter measurements (P < 0.001). Lumen diameter visibility improved, and artificial luminal narrowing decreased from the medium-smooth kernel to the sharp kernel. Visual estimation of all CT angiography using the 3 kernels showed high accuracy for detection of in-stent restenosis (>50%), compared with DSA. Conclusions Computed tomography angiography using a sharp kernel allows for more accurate assessment of lumen visibility after carotid artery stenting.


European Journal of Radiology | 2009

Assessment of vertebral artery stents using 16-slice multi-detector row CT angiography in vivo evaluation: Comparison of a medium-smooth kernel and a sharp kernel

Won Jong Yoo; Yeon Soo Lim; Kook Jin Ahn; Byung Gil Choi; Ji Young Kim; Sung Hoon Kim

OBJECTIVES To assess the lumen visibility of extracranial vertebral artery stents examined with 16-slice multi-detector row computed tomography (MDCT) angiography in vivo using a medium-smooth kernel (B30s) and a sharp kernel (B60s), and to compare these with digital subtraction angiography (DSA) after stent placement. METHODS Twenty stents from 20 patients (14 men, 6 women; mean age, 62.7+/-10.1 years) who underwent CT angiography (CTA) with 16-slice MDCT were retrospectively analyzed. In CT angiograms using a B30s and a B60s, the lumen diameters and CT attenuations of the stented vessels were measured three times by three observers, and artificial luminal narrowing (ALN) was calculated. To assess measurement reliability on CT angiograms, the intraclass correlation coefficient (ICC) was used. DSA served as the reference standard for the in-stent luminal measurements on CT angiography. The median interval between CT angiography and DSA was 1 day (range 1-10). RESULTS For interobserver reliability, intraclass correlation coefficients for the lumen diameters on CT angiograms with a B30s and a B60s were 0.90 and 0.96, respectively. The lumen diameters on CT angiograms using a B30s were consistently smaller than that on CT angiograms using a B60s (p<0.01). The mean ALN was 37+/-7% on CT angiograms using a B30s and 25+/-9% on CT angiograms using a B60s. The mean CT attenuation in in-stent lumen was 347+/-55HU on CT angiograms using a B30s and 295+/-46HU on CT angiograms using a B60s. The ALN and CT attenuation within the stented vessels between CT angiograms using a B30s and a B60s was significant (p<0.01). CONCLUSIONS 16-slice MDCT using a sharp kernel allows good visualization of the stented vessels and is useful in the assessment of vertebral artery stent patency after stent placement.


Acta Radiologica | 2011

Periosteal autograft for articular cartilage defects in dogs: MR imaging and ultrasonography of the repair process.

Mi Sook Sung; Chang Hoon Jeong; Yeon Soo Lim; Won Jong Yoo; Soo Kyo Chung; Na Young Jung

Background Autologous periosteal grafting is used as treatment for cartilage defects. Purpose To assess the role of MR imaging and ultrasonography in the evaluation of the post-graft repair process with imaging and histologic correlation. Material and Methods Periosteal grafts obtained from the tibia of eight dogs were transplanted to the experimental cartilage defects in the femoral condyles (15 knees). The control group was comprised of three dogs (five knees). MR imaging using 4.7T and ultrasonography of the grafted specimens was performed at one, two, four, eight, and 16 weeks after transplantation. The animals were sacrificed at the time of imaging at the previously specified intervals. Histologic analysis with imaging correlation was subsequently performed. Results All specimens taken from one to 16 weeks demonstrated periosteal proliferation in the graft. At one week, experimental cartilage defects were no longer present on MR imaging. Area of high signal intensity (SI) in the defect was present which corresponded to hemorrhage, edema, and fibrosis on histology. At two, four, and eight weeks, all but two graft demonstrated heterogeneous high SI on T2-weighted image, consistent with immature cartilage. At 16 weeks, all grafts showed heterogeneous isointense to adjacent cartilage on all sequences, which corresponded to dominant mature cartilage. The repair tissue near the exposed subchondral bone revealed heterogeneous high SI on T2-weighted images. This corresponded to the fibrosis with vascular penetration and edema. In the control group, no cartilage repair was noted within cartilage defects. The serial MR features of the grafted area correlated well with the histologic findings. Serial sonographic findings were not sufficient to provide the regenerated cartilage maturity. Conclusion MR imaging is capable of depicting the repair characteristics following periosteal grafting for articular cartilage defects. MR imaging may provide useful information in the assessment of the graft appearance with definite implications regarding the degree and success of incorporation.


European Journal of Radiology | 2018

Computed tomographic thoracic morphologic indices in normal subjects and patients with chronic obstructive pulmonary disease: Comparison with spiral CT densitometry and pulmonary function tests

Myung Hee Chung; Bo Mi Gil; Soon Seog Kwon; Hae-il Park; Sun Wha Song; Na Young Jung; Won Jong Yoo

OBJECTIVES To determine what computed tomographic (CT) dimensions can predict obstructive lung disease on routine chest CT scans by comparing morphological and densitometric CT findings with pulmonary function test (PFT) in normal subjects and patients with chronic obstructive pulmonary disease (COPD). MATERIALS AND METHODS Consecutive patients (n = 646; 260 females and 386 males; mean age 54.9 years, ranged 20-90 years) who received chest CT scans with densitometry during a 3-month period were retrospectively analyzed in single center. PFT was undertaken in 235 patients (152 males, 83 females) at same times of CT scanning. The patients were grouped by age (<30 years, 31-45 years, 46-60 years, and >61 years). CT parameters including tracheal, azygoesophageal, thoracic vertical, anterior-posterior (AP), transverse diameters, transverse cardiac diameter, diameters of main, right, and left pulmonary arteries, and CT densitometric values including lung volume and density (-900 to -1000 Hounsfield Units, HU), low attenuation value cluster (default threshold: -950 HU) were compared with PFT values. Spearman correlation coefficients was used to evaluate the relationship between the CT indices and PFT. RESULTS Ninety of 235 patients with PFT were smokers (76 males, 14 females). Obstructive PFT was detected in 65 patients (27.7%: 46 males, 19 females). Male smokers with obstructive PFT displayed significantly larger thoracic anterior-posterior (mean: normal, 172.3 cm versus COPD, 185.9 cm, p = 0.0001) and smaller transverse diameters (mean: normal, 247.0 cm vs. COPD, 235.8 cm, p = 0.01), and increased right pulmonary artery diameter (mean: normal, 20.3 cm v s. COPD, 22.1 cm, p < 0.001), and increased left pulmonary artery diameter (mean: normal, 19.7 cm vs. COPD, 20.6 cm, p < 0.025). The lung parenchyma density (-1000 to -900 HU) and greater concentration of largest cluster on densitometry were significantly different between normal and obstructive PFT pattern in male smoker. Residual volume and total lung capacity are positively correlated with lung volume and lung density (-1000 to -800) of densitometry. CONCLUSIONS CT findings of the overexpansion of the lungs, such as increases in the vertical diameter of the lung and decreases in the transverse diameter of the heart, can be significant as indirect findings of early chronic obstructive diseases. However, despite the significant CT findings in male smokers, particularly those in their 40s, most lung function parameters were not decidedly abnormal.


European Journal of Radiology | 2007

Acute and repeated inhalation lung injury by 3-methoxybutyl chloroformate in rats: CT-pathologic correlation

Yeon Soo Lim; Myung Hee Chung; Seog Hee Park; Hyeon-Yeong Kim; Byung Gil Choi; Hyun Wook Lim; Jin Ah Kim; Won Jong Yoo

Collaboration


Dive into the Won Jong Yoo's collaboration.

Top Co-Authors

Avatar

Myung Hee Chung

Catholic University of Korea

View shared research outputs
Top Co-Authors

Avatar

Mi Sook Sung

Catholic University of Korea

View shared research outputs
Top Co-Authors

Avatar

Yeon Soo Lim

Catholic University of Korea

View shared research outputs
Top Co-Authors

Avatar

Hae Giu Lee

Catholic University of Korea

View shared research outputs
Top Co-Authors

Avatar

Hyun Wook Lim

Catholic University of Korea

View shared research outputs
Top Co-Authors

Avatar

Bum Soo Kim

Catholic University of Korea

View shared research outputs
Top Co-Authors

Avatar

Byung Gil Choi

Catholic University of Korea

View shared research outputs
Top Co-Authors

Avatar

Hong Jun Chung

Catholic University of Korea

View shared research outputs
Top Co-Authors

Avatar

Na Young Jung

Catholic University of Korea

View shared research outputs
Top Co-Authors

Avatar

Seog Hee Park

Catholic University of Korea

View shared research outputs
Researchain Logo
Decentralizing Knowledge