Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Xuefeng Zhuang is active.

Publication


Featured researches published by Xuefeng Zhuang.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2005

Capacitive micromachined ultrasonic transducers: fabrication technology

A.S. Erguri; Yongli Huang; Xuefeng Zhuang; Omer Oralkan; G.G. Yarahoglu; Butrus T. Khuri-Yakub

Capacitive micromachined ultrasonic transducer (MUT) technology is a prime candidate for next generation imaging systems. Medical and underwater imaging and the nondestructive evaluation (NDE) societies have expressed growing interest in cMUTs over the years. Capacitive micromachined ultrasonic transducer technology is expected to make a strong impact on imaging technologies, especially volumetric imaging, and to appear in commercial products in the near future. This paper focuses on fabrication technologies for cMUTs and reviews and compares variations in the production processes. We have developed two main approaches to the fabrication of cMUTs: the sacrificial release process and the recently introduced wafer-bonding method. This paper gives a thorough review of the sacrificial release processes, and it describes the new wafer-bonding method in detail. Process variations are compared qualitatively and quantitatively whenever possible. Through these comparisons, it was concluded that wafer-bonded cMUT technology was superior in terms of process control, yield, and uniformity. Because the number of steps and consequent process time were reduced (from six-mask process to four-mask process), turn-around time was improved significantly.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2008

Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging

Ira O. Wygant; Xuefeng Zhuang; David T. Yeh; Omer Oralkan; A.S. Ergun; Mustafa Karaman; Butrus T. Khuri-Yakub

For three-dimensional (3D) ultrasound imaging, connecting elements of a two-dimensional (2D) transducer array to the imaging systems front-end electronics is a challenge because of the large number of array elements and the small element size. To compactly connect the transducer array with electronics, we flip-chip bond a 2D 16 times 16-element capacitive micromachined ultrasonic transducer (CMUT) array to a custom-designed integrated circuit (IC). Through-wafer interconnects are used to connect the CMUT elements on the top side of the array with flip-chip bond pads on the back side. The IC provides a 25-V pulser and a transimpedance preamplifier to each element of the array. For each of three characterized devices, the element yield is excellent (99 to 100% of the elements are functional). Center frequencies range from 2.6 MHz to 5.1 MHz. For pulse-echo operation, the average -6-dB fractional bandwidth is as high as 125%. Transmit pressures normalized to the face of the transducer are as high as 339 kPa and input-referred receiver noise is typically 1.2 to 2.1 rnPa/ radicHz. The flip-chip bonded devices were used to acquire 3D synthetic aperture images of a wire-target phantom. Combining the transducer array and IC, as shown in this paper, allows for better utilization of large arrays, improves receive sensitivity, and may lead to new imaging techniques that depend on transducer arrays that are closely coupled to IC electronics.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2009

Three-dimensional photoacoustic imaging using a two-dimensional CMUT array

Srikant Vaithilingam; Te-Jen Ma; Yukio Furukawa; Ira O. Wygant; Xuefeng Zhuang; Adam de la Zerda; Omer Oralkan; Aya Kamaya; Sanjiv S. Gambhir; R. Brooke Jeffrey; Butrus T. Khuri-Yakub

In this paper, we describe using a 2-D array of capacitive micromachined ultrasonic transducers (CMUTs) to perform 3-D photoacoustic and acoustic imaging. A tunable optical parametric oscillator laser system that generates nanosecond laser pulses was used to induce the photoacoustic signals. To demonstrate the feasibility of the system, 2 different phantoms were imaged. The first phantom consisted of alternating black and transparent fishing lines of 180 μm and 150 μm diameter, respectively. The second phantom comprised polyethylene tubes, embedded in chicken breast tissue, filled with liquids such as the dye indocyanine green, pig blood, and a mixture of the 2. The tubes were embedded at a depth of 0.8 cm inside the tissue and were at an overall distance of 1.8 cm from the CMUT array. Two-dimensional cross-sectional slices and 3-D volume rendered images of pulse-echo data as well as photoacoustic data are presented. The profile and beamwidths of the fishing line are analyzed and compared with a numerical simulation carried out using the Field II ultrasound simulation software. We investigated using a large aperture (64 x 64 element array) to perform photoacoustic and acoustic imaging by mechanically scanning a smaller CMUT array (16 x 16 elements). Two-dimensional transducer arrays overcome many of the limitations of a mechanically scanned system and enable volumetric imaging. Advantages of CMUT technology for photoacoustic imaging include the ease of integration with electronics, ability to fabricate large, fully populated 2-D arrays with arbitrary geometries, wide-bandwidth arrays and high-frequency arrays. A CMUT based photoacoustic system is proposed as a viable alternative to a piezoelectric transducer based photoacoustic systems.


Medical Imaging 2005: Ultrasonic Imaging and Signal Processing | 2005

High-frequency CMUT arrays for high-resolution medical imaging

David T. Yeh; Omer Oralkan; A.S. Ergun; Xuefeng Zhuang; Ira O. Wygant; Butrus T. Khuri-Yakub

The paper describes high-frequency 1D CMUT arrays designed and fabricated for use in electronically scanned high-resolution ultrasonic imaging systems. Two different designs of 64-element linear CMUT arrays are presented. A single element in each array is connected to a single-channel custom front-end integrated circuit for pulse-echo operation. The first design has a resonant frequency of 43 MHz in air, and operates at 30 MHz in immersion. The second design exhibits a resonant frequency of 60 MHz in air, and operates at 45 MHz in immersion. Experimental results are compared to simulation results obtained from the equivalent circuit model and nonlinear dynamic finite element analysis; a good agreement is observed between these results. The paper also briefly discusses the effects of the area fill factor on the frequency characteristics of CMUTs, which reveals that the transducer active area should be maximized to obtain a wideband response at high frequencies.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2009

Wafer-bonded 2-D CMUT arrays incorporating through-wafer trench-isolated interconnects with a supporting frame

Xuefeng Zhuang; Ira O. Wygant; Der-Song Lin; Mario Kupnik; Omer Oralkan; Butrus T. Khuri-Yakub

This paper reports on wafer-bonded, fully populated 2-D capacitive micromachined ultrasonic transducer (CMUT) arrays. To date, no successful through-wafer via fabrication technique has been demonstrated that is compatible with the wafer-bonding method of making CMUT arrays. As an alternative to through-wafer vias, trench isolation with a supporting frame is incorporated into the 2-D arrays to provide through-wafer electrical connections. The CMUT arrays are built on a silicon-on-insulator (SOI) wafer, and all electrical connections to the array elements are brought to the back side of the wafer through the highly conductive silicon substrate. Neighboring array elements are separated by trenches on both the device layer and the bulk silicon. A mesh frame structure, providing mechanical support, is embedded between silicon pillars, which electrically connect to individual elements. We successfully fabricated a 16 times 16-element 2-D CMUT array using wafer bonding with a yield of 100%. Across the array, the pulse-echo amplitude distribution is uniform (sigma = 6.6% of the mean amplitude). In one design, we measured a center frequency of 7.6 MHz, a peak-to-peak output pressure of 2.9 MPa at the transducer surface, and a 3-dB fractional bandwidth of 95%. Volumetric ultrasound imaging was demonstrated by chip-to-chip bonding one of the fabricated 2-D arrays to a custom-designed integrated circuit (IC). This study shows that through-wafer trench-isolation with a supporting frame is a viable solution for providing electrical interconnects to CMUT elements and that 2-D arrays fabricated using wafer-bonding deliver good performance.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2005

A solution to the charging problems in capacitive micromachined ultrasonic transducers

Yongli Huang; Edward Hæggström; Xuefeng Zhuang; A.S. Ergun; Butrus T. Khuri-Yakub

We report on a capacitive micromachined ultrasonic transducer (CMUT) featuring isolation posts (PostCMUT) as a solution to the charging problems caused by device fabrication and operation. This design improves the device reliability. The PostCMUTs were fabricated using a newly developed process based on the wafer-bonding technique. Paired tests showed the superior reliability characteristics of the PostCMUT design compared to those of conventional CMUT designs. No deleterious effect of the new design was seen in preliminary ultrasonic tests or in process yield. PostCMUTs, a design that serves as a solution to the aforementioned reliability problem, constitutes a major contribution to CMUT commercialization.


IEEE\/ASME Journal of Microelectromechanical Systems | 2008

Fabrication of Flexible Transducer Arrays With Through-Wafer Electrical Interconnects Based on Trench Refilling With PDMS

Xuefeng Zhuang; Der-Song Lin; Omer Oralkan; Butrus T. Khuri-Yakub

Flexible transducer arrays are desired to wrap around catheter tips for side-looking intravascular ultrasound imaging. We present a technique for constructing flexible capacitive micromachined ultrasonic transducer (CMUT) arrays by forming polymer-filled deep trenches in a silicon substrate. First, we etch deep trenches between the bottom electrodes of CMUT elements on a prime silicon wafer using deep reactive ion etching. Second, we fusion-bond a silicon-on-insulator (SOI) wafer to the prime silicon wafer. Once the silicon handle and buried oxide layers are removed from the back side of the SOI wafer, the remaining thin silicon device layer acts as a movable membrane and top electrode. Third, we fill the deep trenches with polydimethylsiloxane, and thin the wafer down from the back side. The 16 by 16 flexible 2-D arrays presented in this paper have a trench width that varies between 6 and 20 ; the trench depth is 150 ; the membrane thickness is 1.83 ; and the final substrate thickness is 150 . We demonstrate the flexibility of the substrate by wrapping it around a needle tip with a radius of 450 (less than catheter size of 3 French). Measurements in air validate the functionality of the arrays. The 250- by 250- transducer elements have a capacitance of 2.29 to 2.67 pF, and a resonant frequency of 5.0 to 4.3 MHz, for dc bias voltages ranging from 70 to 100 V.


internaltional ultrasonics symposium | 2004

Optimized membrane configuration improves CMUT performance

Yongli Huang; Edward Hæggström; Xuefeng Zhuang; A.S. Ergun; Butrus T. Khuri-Yakub

The performance of a capacitive micromachined ultrasonic transducer (CMUT) was improved by optimizing its membrane configuration. CMUTs with three different membrane configurations: square, rectangular and tent, were designed and fabricated using a process based on the wafer-bonding technique. Paired tests showed that improved transmission (TX) and reception (RX) efficiencies were achieved by using tent or rectangular membranes instead of square membranes. The improvements were 46% and 44% in TX and 43% and 65% in RX, respectively.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2006

Comparison of conventional and collapsed region operation of capacitive micromachined ultrasonic transducers

Yongli Huang; Edward Hæggström; Baris Bayram; Xuefeng Zhuang; A.S. Ergun; Ching-Hsiang Cheng; Butrus T. Khuri-Yakub

We report experimental results from a comparative study on collapsed region and conventional region operation of capacitive micromachined ultrasonic transducers (CMUTs) fabricated with a wafer bonding technique. Using ultrasonic pulse-echo and pitch-catch measurements, we characterized single elements of 1-D CMUT arrays operating in oil. The experimental results from this study agreed with the simulation results: a CMUT operating in the collapsed region produced a higher maximum output pressure than a CMUT operated in the conventional region at 90% of its collapse voltage (3 kPa/V vs. 16.1 kPa/V at 2.3 MHz). While the pulse-echo fractional bandwidth (126%) was higher in the collapsed region operation than in the conventional operation (117%), the pulse-echo amplitude in collapsed region operation was 11 dB higher than in conventional region operation. Furthermore, within the range of tested bias voltages, the output pressure monotonously increased with increased bias during collapsed region operation. It was also found that in the conventional mode, short AC pulses (larger than the collapse voltage) could be applied without collapsing the membranes. Finally, while no significant difference was observed in reflectivity of the CMUT face between the two regions of operation, hysteretic behavior of the devices was identified in the collapsed region operation


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2009

Capacitive micromachined ultrasonic transducers with piston-shaped membranes: fabrication and experimental characterization

Yongli Huang; Xuefeng Zhuang; E. Hggstrom; A. Ergun; Ching-Hsiang Cheng; Butrus T. Khuri-Yakub

Capacitive micromachined ultrasonic transducers (CMUTs) featuring piston-shaped membranes (piston CMUTs) were developed to improve device performance in terms of transmission efficiency, reception sensitivity, and fractional bandwidth (FBW). A piston CMUT has a relatively flat active moving surface whose membrane motion is closer to ideal piston-type motion compared with a CMUT with uniformly thick membranes (classical CMUT). Piston CMUTs with a more uniform surface displacement profile can achieve high output pressure with a relatively small electrode separation. The improved device capacitance and gap uniformity also enhance detection sensitivity. By adding a center mass to the membrane, a large ratio of second-order resonant frequency to first-order resonant frequency was achieved. This improved the FBW. Piston CMUTs featuring membranes of different geometric shapes were designed and fabricated using wafer bonding. Fabricating piston CMUTs is a more complex process than fabricating CMUTs with uniformly thick membranes. However, no yield loss was observed. These devices achieved ~100% improvement in transduction performance (transmission and reception) over classical CMUTs. For CMUTs with square and rectangular membranes, the FBW increased from ~110% to ~150% and from ~140% to ~175%, respectively, compared with classical CMUTs. The new devices produced a maximum output pressure exceeding 1 MPa at the transducer surface. Performance optimization using geometric membrane shape configurations was the same in both piston CMUTs and classical CMUTs.

Collaboration


Dive into the Xuefeng Zhuang's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Omer Oralkan

North Carolina State University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Mario Kupnik

Technische Universität Darmstadt

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge