Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where A.S. Ergun is active.

Publication


Featured researches published by A.S. Ergun.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2002

Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging?

Omer Oralkan; A.S. Ergun; Jeremy A. Johnson; Mustafa Karaman; Utkan Demirci; Kambiz Kaviani; Thomas H. Lee; Butrus T. Khuri-Yakub

Piezoelectric materials have dominated the ultrasonic transducer technology. Recently, capacitive micromachined ultrasonic transducers (CMUTs) have emerged as an alternative technology offering advantages such as wide bandwidth, ease of fabricating large arrays, and potential for integration with electronics. The aim of this paper is to demonstrate the viability of CMUTs for ultrasound imaging. We present the first pulse-echo phased array B-scan sector images using a 128-element, one-dimensional (1-D) linear CMUT array. We fabricated 64- and 128-element 1-D CMUT arrays with 100% yield and uniform element response across the arrays. These arrays have been operated in immersion with no failure or degradation in performance over the time. For imaging experiments, we built a resolution test phantom roughly mimicking the attenuation properties of soft tissue. We used a PC-based experimental system, including custom-designed electronic circuits to acquire the complete set of 128/spl times/128 RF A-scans from all transmit-receive element combinations. We obtained the pulse-echo frequency response by analyzing the echo signals from wire targets. These echo signals presented an 80% fractional bandwidth around 3 MHz, including the effect of attenuation in the propagating medium. We reconstructed the B-scan images with a sector angle of 90 degrees and an image depth of 210 mm through offline processing by using RF beamforming and synthetic phased array approaches. The measured 6-dB lateral and axial resolutions at 135 mm depth were 0.0144 radians and 0.3 mm, respectively. The electronic noise floor of the image was more than 50 dB below the maximum mainlobe magnitude. We also performed preliminary investigations on the effects of crosstalk among array elements on the image quality. In the near field, some artifacts were observable extending out from the array to a depth of 2 cm. A tail also was observed in the point spread function (PSF) in the axial direction, indicating the existence of crosstalk. The relative amplitude of this tail with respect to the mainlobe was less than -20 dB.


IEEE\/ASME Journal of Microelectromechanical Systems | 2003

Fabricating capacitive micromachined ultrasonic transducers with wafer-bonding technology

Yongli Huang; A.S. Ergun; Edward Hæggström; M.H. Badi; Butrus T. Khuri-Yakub

Introduces a new method for fabricating capacitive micromachined ultrasonic transducers (CMUTs) that uses a wafer bonding technique. The transducer membrane and cavity are defined on an SOI (silicon-on-insulator) wafer and on a prime wafer, respectively. Then, using silicon direct bonding in a vacuum environment, the two wafers are bonded together to form a transducer. This new technique, capable of fabricating large CMUTs, offers advantages over the traditionally micromachined CMUTs. First, forming a vacuum-sealed cavity is relatively easy since the wafer bonding is performed in a vacuum chamber. Second, this process enables better control over the gap height, making it possible to fabricate very small gaps (less than 0.1 /spl mu/m). Third, since the membrane is made of single crystal silicon, it is possible to predict and control the mechanical properties of the membrane to within 5%. Finally, the number of process steps involved in making a CMUT has been reduced from 22 to 15, shortening the device turn-around time. All of these advantages provide repeatable fabrication of CMUTs featuring predictable center frequency, bandwidth, and collapse voltage.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2008

Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging

Ira O. Wygant; Xuefeng Zhuang; David T. Yeh; Omer Oralkan; A.S. Ergun; Mustafa Karaman; Butrus T. Khuri-Yakub

For three-dimensional (3D) ultrasound imaging, connecting elements of a two-dimensional (2D) transducer array to the imaging systems front-end electronics is a challenge because of the large number of array elements and the small element size. To compactly connect the transducer array with electronics, we flip-chip bond a 2D 16 times 16-element capacitive micromachined ultrasonic transducer (CMUT) array to a custom-designed integrated circuit (IC). Through-wafer interconnects are used to connect the CMUT elements on the top side of the array with flip-chip bond pads on the back side. The IC provides a 25-V pulser and a transimpedance preamplifier to each element of the array. For each of three characterized devices, the element yield is excellent (99 to 100% of the elements are functional). Center frequencies range from 2.6 MHz to 5.1 MHz. For pulse-echo operation, the average -6-dB fractional bandwidth is as high as 125%. Transmit pressures normalized to the face of the transducer are as high as 339 kPa and input-referred receiver noise is typically 1.2 to 2.1 rnPa/ radicHz. The flip-chip bonded devices were used to acquire 3D synthetic aperture images of a wire-target phantom. Combining the transducer array and IC, as shown in this paper, allows for better utilization of large arrays, improves receive sensitivity, and may lead to new imaging techniques that depend on transducer arrays that are closely coupled to IC electronics.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2003

Calculation and measurement of electromechanical coupling coefficient of capacitive micromachined ultrasonic transducers

Goksen G. Yaralioglu; A.S. Ergun; Baris Bayram; Edward Hæggström; Butrus T. Khuri-Yakub

The electromechanical coupling coefficient is an important figure of merit of ultrasonic transducers. The transducer bandwidth is determined by the electromechanical coupling efficiency. The coupling coefficient is, by definition, the ratio of delivered mechanical energy to the stored total energy in the transducer. In this paper, we present the calculation and measurement of coupling coefficient for capacitive micromachined ultrasonic transducers (CMUTs). The finite element method (FEM) is used for our calculations, and the FEM results are compared with the analytical results obtained with parallel plate approximation. The effect of series and parallel capacitances in the CMUT also is investigated. The FEM calculations of the CMUT indicate that the electromechanical coupling coefficient is independent of any series capacitance that may exist in the structure. The series capacitance, however, alters the collapse voltage of the membrane. The parallel parasitic capacitance that may exist in a CMUT or is external to the transducer reduces the coupling coefficient at a given bias voltage. At the collapse, regardless of the parasitics, the coupling coefficient reaches unity. Our experimental measurements confirm a coupling coefficient of 0.85 before collapse, and measurements are in agreement with theory.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2003

Volumetric ultrasound imaging using 2-D CMUT arrays

Omer Oralkan; A.S. Ergun; Ching-Hsiang Cheng; Jeremy A. Johnson; Mustafa Karaman; Thomas H. Lee; Butrus T. Khuri-Yakub

Recently, capacitive micromachined ultrasonic transducers (CMUTs) have emerged as a candidate to overcome the difficulties in the realization of 2-D arrays for real-time 3-D imaging. In this paper, we present the first volumetric images obtained using a 2-D CMUT array. We have fabricated a 128/spl times/128-element 2-D CMUT array with through-wafer via interconnects and a 420-/spl mu/m element pitch. As an experimental prototype, a 32/spl times/64-element portion of the 128/spl times/128-element array was diced and flip-chip bonded onto a glass fanout chip. This chip provides individual leads from a central 16/spl times/16-element portion of the array to surrounding bondpads. An 8/spl times/16-element portion of the array was used in the experiments along with a 128-channel data acquisition system. For imaging phantoms, we used a 2.37-mm diameter steel sphere located 10 mm from the array center and two 12-mm-thick Plexiglas plates located 20 mm and 60 mm from the array. A 4/spl times/4 group of elements in the middle of the 8/spl times/16-element array was used in transmit, and the remaining elements were used to receive the echo signals. The echo signal obtained from the spherical target presented a frequency spectrum centered at 4.37 MHz with a 100% fractional bandwidth, whereas the frequency spectrum for the echo signal from the parallel plate phantom was centered at 3.44 MHz with a 91% fractional bandwidth. The images were reconstructed by using RF beamforming and synthetic phased array approaches and visualized by surface rendering and multiplanar slicing techniques. The image of the spherical target has been used to approximate the point spread function of the system and is compared with theoretical expectations. This study experimentally demonstrates that 2-D CMUT arrays can be fabricated with high yield using silicon IC-fabrication processes, individual electrical connections can be provided using through-wafer vias, and flip-chip bonding can be used to integrate these dense 2-D arrays with electronic circuits for practical 3-D imaging applications.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2004

Forward-viewing CMUT arrays for medical imaging

Utkan Demirci; A.S. Ergun; Omer Oralkan; Mustafa Karaman; Butrus T. Khuri-Yakub

This paper reports the design and testing of forward-viewing annular arrays fabricated using capacitive micromachined ultrasonic transducer (CMUT) technology. Recent research studies have shown that CMUTs have broad frequency bandwidth and high-transduction efficiency. One- and two-dimensional CMUT arrays of various sizes already have been fabricated, and their viability for medical imaging applications has been demonstrated. We fabricated 64-element, forward-viewing annular arrays using the standard CMUT fabrication process and carried out experiments to measure the operating frequency, bandwidth, and transmit/receive efficiency of the array elements. The annular array elements, designed for imaging applications in the 20 MHz range, had a resonance frequency of 13.5 MHz in air. The immersion pulse-echo data collected from a plane reflector showed that the devices operate in the 5-26 MHz range with a fractional bandwidth of 135%. The output pressure at the surface of the transducer was measured to be 24 kPa/V. These values translate into a dynamic range of 131.5 dB for 1-V excitation in 1-Hz bandwidth with a commercial low noise receiving circuitry. The designed, forward-viewing annular CMUT array is suitable for mounting on the front surface of a cylindrical catheter probe and can provide Doppler information for measurement of blood flow and guiding information for navigation through blood vessels in intravascular ultrasound imaging.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2005

Capacitive micromachined ultrasonic transducer design for high power transmission

Baris Bayram; Omer Oralkan; A.S. Ergun; Edward Hæggström; Goksen G. Yaralioglu; Butrus T. Khuri-Yakub

Capacitive micromachined ultrasonic transducers (cMUTs) were developed to meet the demands of the ultrasonic industry. To achieve maximum efficiency, the conventional operation of the cMUT requires a bias voltage close to the collapse voltage. Total acoustic output pressure is limited by the efficiency of the cMUT and the maximum-allowed pulse voltage on the membrane. In this paper, we propose the collapse-snapback operation of the cMUT: the membrane is collapsed onto the substrate in the collapsing cycle, and released in the snapback cycle. The collapse-snapback operation overcomes the above-mentioned limitations of the conventional operation. The collapse-snapback operation utilizes a larger range of membrane deflection profiles (both collapsed and released profiles) and generates higher acoustic output pressures. The static finite element calculations were performed to design cMUTs with specific collapse and snapback voltages by changing the electrode parameters (radius (r/sub e/), position (d/sub e/), and thickness (t/sub e/)). These designs were refined for optimum average displacement per cycle. An electrode radius greater than 60% of the membrane radius significantly improved the displacement per volt. Moderately thick membranes (t/sub e//spl sim/0.2 /spl mu/m) were preferred, as thicker membranes reduced the displacement per volt. Under proper bias conditions, the collapse-snapback operation, designed for high-power transmission, allowed the application of pulse voltages larger than the difference of collapse and snapback voltages. Dynamic finite element calculations of an infinite cMUT array on the substrate loaded with acoustic fluid medium were performed to determine the dynamic response of the cMUT. Commercially available FEM packages ANSYS and LSDYNA were used for static and dynamic calculations, respectively. The cMUTs were fabricated for optimal performance in the collapse-snapback operation. The transmit experiments were performed on a 2-D cMUT array using a calibrated hydrophone. Taking into account the attenuation and diffraction losses, the pressure on the cMUT surface was extracted. The cMUT generated 0.47 MPa (6 kPa/V) and 1.04 MPa (11 kPa/V) in the conventional and collapse-snapback operations, respectively. Therefore, collapse-snapback operation of the cMUTs was superior for high-power transmission.


Applied Physics Letters | 2007

Capacitive micromachined ultrasonic transducers for chemical detection in nitrogen

Kwan Kyu Park; Hoo-Jeong Lee; Goksen G. Yaralioglu; A.S. Ergun; Omer Oralkan; Mario Kupnik; C. F. Quate; Butrus T. Khuri-Yakub; Thomas Braun; J.-P. Ramseyer; Hans Peter Lang; Martin Hegner; Ch. Gerber; James K. Gimzewski

The authors present the prototype of a chemical sensor using a capacitive micromachined ultrasonic transducer array. Each element in the array consists of a large number of resonating membranes connected in parallel. A five-channel oscillator circuit operates at the resonant frequency around 6MHz in this prototype. The surface of the elements in the array is coated by polymers such as polyallylamine hydrochloride, polyethylene glycol, and polyvinyl alcohol to detect different chemicals. By measuring shift in oscillation frequencies due to the mass-loading effect, analytes, e.g., water and isopropanol, with concentrations around 20ppbv (parts per 109 by volume) range can be detected.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2007

Finite element modeling and experimental characterization of crosstalk in 1-D CMUT arrays

Baris Bayram; Mario Kupnik; Goksen G. Yaralioglu; Omer Oralkan; A.S. Ergun; Serena H. Wong; Butrus T. Khuri-Yakub

Crosstalk is the coupling of energy between the elements of an ultrasonic transducer array. This coupling degrades the performance of transducers in applications such as medical imaging and therapeutics. In this paper, we present an experimental demonstration of guided interface waves in capacitive micromachined ultrasonic transducers (CMUTs). We compare the experimental results to finite element calculations using a commercial package (LS-DYNA) for a 1-D CMUT array operating in the conventional and collapsed modes. An element in the middle of the array was excited with a unipolar voltage pulse, and the displacements were measured using a laser interferometer along the center line of the array elements immersed in soybean oil. We repeated the measurements for an identical CMUT array covered with a 4.5-mum polydimethyl-siloxane (PDMS) layer. The main crosstalk mechanism is the dispersive guided modes propagating in the fluid-solid interface. Although the transmitter element had a center frequency of 5.8 MHz with a 130% fractional bandwidth in the conventional operation, the dispersive guided mode was observed with the maximum amplitude at a frequency of 2.1 MHz, and had a cut-off frequency of 4 MHz. In the collapsed operation, the dispersive guided mode was observed with the maximum amplitude at a frequency of 4.0 MHz, and had a cut-off frequency of 10 MHz. Crosstalk level was lower in the collapsed operation (-39 dB) than in the conventional operation (-24.4 dB). The coverage of the PDMS did not significantly affect the crosstalk level, but reduced the phase velocity for both operation modes. Lamb wave modes, A0 and S0, were also observed with crosstalk levels of -40 dB and -65 dB, respectively. We observed excellent agreement between the finite element and the experimental results


Medical Imaging 2005: Ultrasonic Imaging and Signal Processing | 2005

High-frequency CMUT arrays for high-resolution medical imaging

David T. Yeh; Omer Oralkan; A.S. Ergun; Xuefeng Zhuang; Ira O. Wygant; Butrus T. Khuri-Yakub

The paper describes high-frequency 1D CMUT arrays designed and fabricated for use in electronically scanned high-resolution ultrasonic imaging systems. Two different designs of 64-element linear CMUT arrays are presented. A single element in each array is connected to a single-channel custom front-end integrated circuit for pulse-echo operation. The first design has a resonant frequency of 43 MHz in air, and operates at 30 MHz in immersion. The second design exhibits a resonant frequency of 60 MHz in air, and operates at 45 MHz in immersion. Experimental results are compared to simulation results obtained from the equivalent circuit model and nonlinear dynamic finite element analysis; a good agreement is observed between these results. The paper also briefly discusses the effects of the area fill factor on the frequency characteristics of CMUTs, which reveals that the transducer active area should be maximized to obtain a wideband response at high frequencies.

Collaboration


Dive into the A.S. Ergun's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Omer Oralkan

North Carolina State University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge