Yiru Wang
Xiamen University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Yiru Wang.
Analytica Chimica Acta | 2010
Jinmei Chen; Jing Zou; Jingbin Zeng; Xinhong Song; Jiaojiao Ji; Yiru Wang; Jaeho Ha; Xi Chen
In this paper, a novel graphene (G) based solid-phase microextraction (SPME) fiber was firstly prepared by immobilizing the synthesized G on stainless steel wire as coating. The new fiber possessed a homogeneous, porous and wrinkled surface and showed excellent thermal (over 330°C), chemical and mechanical stability, and long lifespan (over 250 extractions). The SPME performance of the G-coated fiber was evaluated in detail through extraction of six pyrethroid pesticides. Although the thickness of G-coated fiber was only 6-8 μm, its extraction efficiencies were higher than those of two commercial fibers (PDMS, 100 μm; PDMS/DVB, 65 μm). This high extraction efficiency may be mainly attributed to huge delocalized π-electron system of G, which shows strong π-stacking interaction with pyrethroid pesticide. The G-coated fiber was applied in the gas chromatographic determination of six pyrethroids, and their limits of detection were found to be ranged from 3.69 to 69.4 ng L(-1). The reproducibility for each single fiber was evaluated and the relative standard deviations (RSDs) were calculated to be in the range from 1.9% to 6.5%. The repeatability of fiber-to-fiber and batch-to-batch was 4.3-9.2% and 4.1-9.9%. The method developed was successfully applied to three pond water samples, and the recoveries were 83-110% at a spiking of 1 μg L(-1).
Analytical Chemistry | 2015
Mingcong Rong; Liping Lin; Xinhong Song; Tingting Zhao; Yunxin Zhong; Jiawei Yan; Yiru Wang; Xi Chen
An effective and facile fluorescence sensing approach for the determination of 2,4,6-trinitrophenol (TNP) using the chemically oxidized and liquid exfoliated graphitic carbon nitride (g-C3N4) nanosheets was developed. The strong inner filter effect and molecular interactions (electrostatic, π-π, and hydrogen bonding interactions) between TNP and the g-C3N4 nanosheets led to the fluorescence quenching of the g-C3N4 nanosheets with efficient selectivity and sensitivity. Under optimal conditions, the limit of detection for TNP was found to be 8.2 nM. The proposed approach has potential application for visual detection of TNP in natural water samples for public safety and security.
Analyst | 2011
Xiao-mei Chen; Genghuang Wu; Yaqi Jiang; Yiru Wang; Xi Chen
Similar to its popular older cousins of fullerene and carbon nanotubes (CNTs), the latest form of nanocarbon, graphene, is inspiring intensive research efforts in its own right. As an atomically thin layer of sp(2)-hybridized carbon, graphene possesses spectacular electronic, optical, magnetic, thermal and mechanical properties, which make it an exciting material in a variety of important applications. In this review, we present the current advances in the field of graphene electroanalytical chemistry, including the modern methods of graphene production, and graphene functionalization. Electrochemical (bio) sensing developments using graphene and graphene-based materials are summarized in more detail, and we also speculate on their future and discuss potential progress for their applications in electroanalytical chemistry.
Journal of Separation Science | 2011
Jing Zou; Xinhong Song; Jiaojiao Ji; Weici Xu; Jinmei Chen; Ya-Qi Jiang; Yiru Wang; Xi Chen
A polypyrrole (Ppy)/graphene (G) composite was developed and applied as a novel coating for use in solid-phase microextraction (SPME) coupled with gas chromatography (GC). The Ppy/G-coated fiber was prepared by electrochemically polymerizing pyrrole and G on a stainless-steel wire. The extraction efficiency of Ppy/G-coated fiber for five phenols was the highest compared with the fibers coated with either Ppy or Ppy/graphene oxide (GO) using the same method preparation. Significantly, compared with various commercial fibers, the extraction efficiency of Ppy/G-coated fiber is better than or comparable to 85 μm CAR/PDMS fiber (best extraction efficiency of phenol, o-cresol, and m-cresol in commercial fibers) and 85 μm polyacrylate (PA) fiber (best extraction efficiency of 2,4-dichlorophenol and p-bromophenol in commercial fibers). The effects of extraction and desorption parameters such as extraction time, stirring rate, and desorption temperature and time on the extraction/desorption efficiency were investigated and optimized. The calibration curves were linear from 10 to 1000 μg/L for o-cresol, m-cresol, p-bromophenol, and 2,4-dichlorophenol, and from 50 to 1000 μg/L for phenol. The detection limits were within the range 0.34-3.4 μg/L. The single fiber and fiber-to-fiber reproducibilities were <8.3 (n=7) and 13.3% (n=4), respectively. The recovery of the phenols spiked in natural water samples at 200 μg/L ranged from 74.1 to 103.9% and the relative standard deviations were <3.7%.
Analytica Chimica Acta | 2015
Liping Lin; Xinhong Song; Yiying Chen; Mingcong Rong; Tingting Zhao; Yiru Wang; Yaqi Jiang; Xi Chen
In this paper, the highly intrinsic peroxidase-like catalytic activity of nitrogen-doped graphene quantum dots (N-GQDs) is revealed. This activity was greatly dependent on pH, temperature and H2O2 concentration. The experimental results showed that the stable N-GQDs could be used for the detection of H2O2 and glucose over a wide range of pH and temperature, offering a simple, highly selective and sensitive approach for their colorimetric sensing. The linearity between the analyte concentration and absorption ranged from 20 to 1170 μM for H2O2 and 25 to 375 μM for glucose with a detection limit of 5.3 μM for H2O2 and 16 μM for glucose. This assay was also successfully applied to the detection of glucose concentrations in diluted serum and fruit juice samples.
Journal of Chromatography A | 2012
Jiaojiao Ji; Haihong Liu; Jinmei Chen; Jingbin Zeng; Jianli Huang; Leihong Gao; Yiru Wang; Xi Chen
Zinc oxide (ZnO) nanorods based solid-phase microextraction (SPME) coating was directly prepared on stainless steel wires using in situ hydrothermal growth method. This coating has high surface-to-volume ratio with a diameter in the range of 300-500 nm and a thickness of about 3-5 μm. A guiding tube was introduced into the laboratory-made SPME fiber to protect the ZnO nanorods coating from shaving, which significantly improved the method repeatability and prolonged the service life of the coating. The extraction properties of the prepared fiber were investigated using headspace SPME (HS-SPME) coupled to gas chromatography (GC) for the determination of aldehydes in instant noodle samples. The extraction efficiency of the coating for the five aldehydes was comparable to that of a commercial 85 μm Carboxen/Polydimethylsiloxane fiber, which has been reported to have best affinity towards aldehydes among all commercial fibers. The linear ranges of the proposed HS-SPME-GC method were from 0.05 to 5 μg g⁻¹ (hexanal, nonanal and decanal) and 0.1-5 μg g⁻¹ (heptanal and octanal), with the correlation coefficients from 0.990 to 0.999. The method developed was successfully applied to the determination of five aldehydes in instant noodle samples, and the recoveries were found to be 70.5-129% at the spiking level of 2 μg g⁻¹.
Angewandte Chemie | 2016
Xinhong Song; Yiying Chen; Mingcong Rong; Zhaoxiong Xie; Tingting Zhao; Yiru Wang; Xi Chen; Otto S. Wolfbeis
Surfaces with super-amphiphilicity have attracted tremendous interest for fundamental and applied research owing to their special affinity to both oil and water. It is generally believed that 3D graphenes are monoliths with strongly hydrophobic surfaces. Herein, we demonstrate the preparation of a 3D super-amphiphilic (that is, highly hydrophilic and oleophilic) graphene-based assembly in a single-step using phytic acid acting as both a gelator and as a dopant. The product shows both hydrophilic and oleophilic intelligence, and this overcomes the drawbacks of presently known hydrophobic 3D graphene assemblies. It can absorb water and oils alike. The utility of the new material was demonstrated by designing a heterogeneous catalytic system through incorporation of a zeolite into its amphiphilic 3D scaffold. The resulting bulk network was shown to enable efficient epoxidation of alkenes without prior addition of a co-solvent or stirring. This catalyst also can be recovered and re-used, thereby providing a clean catalytic process with simplified work-up.
Journal of Chromatography A | 2010
Jingbin Zeng; Jinmei Chen; Xinhong Song; Yiru Wang; Jaeho Ha; Xi Chen; Xiaoru Wang
In this paper, we proposed an approach using a multi-walled carbon nanotubes (MWCNTs)/Nafion composite coating as a working electrode for the electrochemically enhanced solid-phase microextraction (EE-SPME) of charged compounds. Suitable negative and positive potentials were applied to enhance the extraction of cationic (protonated amines) and anionic compounds (deprotonated carboxylic acids) in aqueous solutions, respectively. Compared to the direct SPME mode (DI-SPME) (without applying potential), the EE-SPME presented more effective and selective extraction of charged analytes primarily via electrophoresis and complementary charge interaction. The experimental parameters relating to extraction efficiency of the EE-SPME such as applied potentials, extraction time, ionic strength, sample pH were studied and optimized. The linear dynamic range of developed EE-SPME-GC for the selected amines spanned three orders of magnitude (0.005-1mugmL(-1)) with R(2) larger than 0.9933, and the limits of detection were in the range of 0.048-0.070ngmL(-1). All of these characteristics demonstrate that the proposed MWCNTs/Nafion EE-SPME is an efficient, flexible and versatile sampling and extraction tool which is ideally suited for use with chromatographic methods.
Journal of Chromatography A | 2009
Wenfeng Chen; Jingbin Zeng; Jinmei Chen; Xiaoli Huang; Yaqi Jiang; Yiru Wang; Xi Chen
A novel solid-phase microextraction (SPME) fiber coated with multiwalled carbon nanotubes (MWCNTs)/Nafion was developed and applied for the extraction of polar aromatic compounds (PACs) in natural water samples. The characteristics and the application of this fiber were investigated. Electron microscope photographs indicated that the MWCNTs/Nafion coating with average thickness of 12.5microm was homogeneous and porous. The MWCNTs/Nafion coated fiber exhibited higher extraction efficiency towards polar aromatic compounds compared to an 85microm commercial PA fiber. SPME experimental conditions, such as fiber coating, extraction time, stirring rate, desorption temperature and desorption time, were optimized in order to improve the extraction efficiency. The calibration curves were linear from 0.01 to 10microgmL(-1) for five PACs studied except p-nitroaniline (from 0.005 to 10microgmL(-1)) and m-cresol (from 0.001 to 10microgmL(-1)), and detection limits were within the range of 0.03-0.57ngmL(-1). Single fiber and fiber-to-fiber reproducibility were less than 7.5 (n=7) and 10.0% (n=5), respectively. The recovery of the PACs spiked in natural water samples at 1microgmL(-1) ranged from 83.3 to 106.0%.
Journal of Chromatography A | 2011
Jingbin Zeng; Jing Zou; Xinhong Song; Jinmei Chen; Jiaojiao Ji; Bo Wang; Yiru Wang; Jaeho Ha; Xi Chen
This work describes an electrochemically enhanced solid-phase microextraction (EE-SPME) method using a mild negative potential (-0.6 V) for the enhanced extraction of the selected basic drugs in a pure aqueous matrix and urine samples. The EE-SPME method gave a more effective extraction of drugs (primarily via electrophoresis and complementary charge interaction) compared to that obtained with SPME (without applying a potential, and which is based on passive partitioning). The EE-SPME method eliminated the need for alkalizing, derivatizing the drugs, or modifying the fiber coating before extraction. The analysis of methamphetamine (MA) and amphetamine (AM) was selected as a typical example to demonstrate in detail the advantages of EE-SPME over SPME. Based on the results obtained, 3-min extraction efficiency for both the amphetamines using EE-SPME was better than that of 30-min using SPME. The developed EE-SPME-GC method exhibited wide linear ranges (2-1000 ng mL(-1)) for both the amphetamines with R(2) larger than 0.99, and the method detection limits (MDLs) for AM and MA were 0.26 and 0.12 ng mL(-1), respectively. In addition, the EE-SPME method developed was also successfully applied to enhance the extraction of several other basic drugs (ephedrine, 3,4-methylenedioxyamphetamine (MDA), atropine, methadone, cocaine, codeine, acetylcodeine and papaverine) with preconcentration factors from 157 to 2199, indicating the potential applicability of this method in the field of forensic, clinical and pharmaceutical analysis.