Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Yoshitaka Oshima is active.

Publication


Featured researches published by Yoshitaka Oshima.


radio and wireless symposium | 2011

Novel high-spatial resolution probe for electric near-field measurement

Daisuke Uchida; Toshiaki Nagai; Yoshitaka Oshima; Shinichi Wakana

A new probe with a micro-hole chip has been developed for measurement of near-field electrical radiation from printed circuit boards. The chip is fixed onto a semi-rigid cable probe facet and the radiated electric field is coupled with the surface of its inner conductor through an aperture with a diameter of 100 µm. Using a 50-µm-wide microstrip line for the device under test, we obtained a distance of 100 µm where the probe output decreases by 6 dB at a measurement height of 50 µm. This distance is in good agreement with our simulation results based on FDTD analysis. With a rectangular aperture of having a 50 µm width, we obtained a 72 µm distance at a 25 µm height. In addition, we confirmed that both the S21 characteristics of the measured line and the frequency characteristics of the probe can be dramatically improved by covering the outside of the probe with magnetic film.


machine vision applications | 1998

Development of high-speed 3D inspection system for solder bumps

Youji Nishiyama; Hiroyuki Tsukahara; Yoshitaka Oshima; Fumiyuki Takahashi; Takashi Fuse; Tohru Nishino

We developed a high-speed 3D inspection system for solder bumps. The system applies laser-based triangulation with a laser diode, an acousto-optical deflector (AOD), and a position sensitive detector. The system scans LSI surfaces with a laser beam at a 15 m/s scanning speed, and can acquire height data at rate of up to 7 X 106 samples/sec with 0.8 micrometers resolution. For high-speed laser beam scanning with the AOD, we developed a technique to correct for the cylindrical lensing effect that causes astigmatism on a focal plane. Our correction method is unique in that it notices the scanning speed being constant in order for the dynamic deviation to be erased. This technique can suppress these deviations enough to enable accurate laser scanning. When installed on an LSI chip assembly line, the system can measure each bump height to within +/- 2 micrometers in 5 ms. This will allow for a 100% inspection to be achieved.


Archive | 1989

Optical system for detecting three-dimensional shape

Yoshikazu Kakinoki; Masato Nakashima; Tetsuo Koezuka; Noriyuki Hiraoka; Hiroyuki Tsukahara; Yoshinori Suto; Yoshitaka Oshima; Shinji Hashinami


Archive | 1997

Method for inspecting height, and a height inspection apparatus to carry out the method

Fumiyuki Takahashi; Hiroyuki Tsukahara; Yoshitaka Oshima; Youji Nishiyama; Takashi Fuse


Archive | 1991

Method of and apparatus for multi-image inspection of bonding wire

Hiroyuki Tsukahara; Yoshitaka Oshima; Masato Nakashima


Archive | 1993

Inspecting apparatus for stereoscopic appearance of electrode

Moritoshi Ando; Takashi Fuse; Yoshiaki Goto; Yoji Nishiyama; Yoshitaka Oshima; Fumiyuki Takahashi; Hiroyuki Tsukahara; 博之 塚原; 美隆 大嶋; 護俊 安藤; 貴史 布施; 善朗 後藤; 陽二 西山; 文之 高橋


Archive | 1991

Method and apparatus for measuring three-dimensional configuration of wire-shaped object in a short time

Moritoshi Ando; Hiroyuki Tsukahara; Yoshitaka Oshima


Archive | 2000

Method and apparatus for inspecting bumps and determining height from a regular reflection region

Fumiyuki Takahashi; Hiroyuki Tsukahara; Yoshitaka Oshima; Youji Nishiyama; Takashi Fuse


Archive | 1997

Height measurement device and height measurement method

Takashi Fuse; Hiroyuki Tsukahara; Yoshitaka Oshima; Youji Nishiyama; Fumiyuki Takahashi


Archive | 1999

Wiring pattern inspection method, and its device

Takashi Fuse; Yoji Nishiyama; Yoshitaka Oshima; Fumiyuki Takahashi; Hiroyuki Tsukahara; 博之 塚原; 美隆 大嶋; 貴史 布施; 陽二 西山; 文之 高橋

Collaboration


Dive into the Yoshitaka Oshima's collaboration.

Researchain Logo
Decentralizing Knowledge