Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where You Me Kim is active.

Publication


Featured researches published by You Me Kim.


Journal of Ultrasound in Medicine | 2010

Breast and scrotal sparganosis: sonographic findings and pathologic correlation.

Su Jin Hong; You Me Kim; Min Seo; Kyu Soon Kim

Objective. Sparganosis is caused by the tapeworm larva of the geneus Spirometra. Because sparganosis usually manifests as a migrating subcutaneous mass, sonography can play an important role in its diagnosis. Methods. In this series, we investigated 4 cases of subcutaneous sparganosis and focused on the sonographic findings. Three of the cases involved the breast, and the other involved the scrotum, as confirmed by surgery. Results. The characteristics of subcutaneous sparganosis included a poorly defined hyperechoic lesion with internal serpiginous tubular structures, anechoic serpiginous tubular structures with a surrounding hyperechoic lesion, and an elongated hyperechoic mass with a hypoechoic nodular lesion in the central portion. Conclusions. We suggest that a mass combined with a hypoechoic tubular structure should raise the suspicion of subcutaneous sparganosis.


Korean Journal of Radiology | 2016

Performance of Screening Mammography: A Report of the Alliance for Breast Cancer Screening in Korea.

Eun Hye Lee; Keum Won Kim; Young Joong Kim; Dong Rock Shin; Young Mi Park; Hyo Soon Lim; Jeong Seon Park; Hye Won Kim; You Me Kim; Hye Jung Kim; Jae Kwan Jun

Objective To analyze the diagnostic accuracy and trend in screening mammography in Korea. Materials and Methods We retrospectively linked the information from hospitals participating in the Alliance of Breast Cancer Screening in Korea (ABCS-K) and the database of the National Cancer Screening Program. We calculated performance indicators, including the recall rate, cancer detection rate (CDR), positive predictive value (PPV), sensitivity, specificity, false-positive rate (FPR), and interval cancer rate (ICR). Changes in the performance indicators were calculated as the annual percent change with 95% confidence interval (CI). Results We enrolled 128756 cases from 10 hospitals from 2005 to 2010. The recall rate was 19.1% with a downward trend over time (-12.1% per year; 95% CI, -15.9 to -8.2). The CDR was 2.69 per 1000 examinations, without a significant trend. The PPV was 1.4% with an upward trend (20.8% per year; 95% CI, 15.2 to 26.7). The sensitivity was 86.5% without a significant trend, whereas the specificity was 81.1% with an upward trend (3.3% per year; 95% CI, 2.1 to 4.5). The FPR was 18.9% with a downward trend (-12.4% per year; 95% CI, -16.2 to -8.4). The ICR was 0.5 per 1000 negative examinations without a significant trend. There were institutional variations in the diagnostic accuracy and trend except for the CDR, sensitivity, and ICR. Conclusion The sensitivity and CDR of screening mammography in the ABCS-K from 2005 to 2010 were compatible with those for Western women. The recall rate, PPV and specificity, however, were suboptimal, although they showed significant improvements over this period. A further analysis is required to explain institutional variations.


Ultrasonography | 2016

Comparison of needle aspiration and vacuum-assisted biopsy in the ultrasound-guided drainage of lactational breast abscesses.

Yun Dan Kang; You Me Kim

Purpose: The purpose of this study was to compare needle aspiration and vacuum-assistedbiopsy in the ultrasound-guided treatment of lactational breast abscesses. Methods: Between January 2005 and December 2014, a total of 74 patients presented withlactational breast abscesses. Thirty of these patients underwent treatment with antibioticsalone, while the remaining 44 lactating women with breast abscesses were treated withneedle aspiration (n=25) or vacuum-assisted biopsy (n=19). Age, duration of lactation, abscess diameter, pus culture results, the number of interventions, the healing time, and the cure rate were reviewed and compared between these two groups. The Student’s t test and the chi-square test were used to compare the variables. Results: No significant difference was found in the cure rate between the needle aspirationgroup (22/25, 88%) and the vacuum-assisted biopsy group (18/19, 94.7%) (P=0.441). However, the mean healing time was significantly shorter in the vacuum-assisted biopsy group (6.7 days) than in the needle aspiration group (9.0 days) (P=0.001). Conclusion: Vacuum-assisted biopsy is a viable option for the management of lactational breast abscesses and was found to lead to a shorter healing time than needle aspiration. However, further study is necessary to establish the clinical efficacy of vacuum-assisted biopsy in the management of lactational breast abscesses.


Iranian Journal of Radiology | 2016

Epistaxis as the First Manifestation of Silent Renal Cell Carcinoma: A Case Report with Relevant Literature Review

Seung Min Lee; You Me Kim; Bong Man Kim

The paranasal sinuses are known to be a rare location for metastasis. Renal cell carcinoma (RCC) is the most frequent primary tumor to metastasize to the sinonasal region, followed by lung and breast cancer. In particular, clear cell type RCC, which represents approximately 85% of RCCs, is characterized by early metastasis, and it sometimes spreads to unusual sites (1, 2). Metastatic tumors in the paranasal sinuses are distributed in the maxillary, sphenoid, ethmoid, and frontal sinuses, in order of decreasing frequency. Symptoms are usually nonspecific, but epistaxis is the most common sign, due to the hypervascularity of the primary tumor. The prognosis is uncertain, but the 5-year survival rate fluctuates between 15% and 30%. The purpose of this case report is to document a rare case of silent RCC that first presented as epistaxis due to nasal cavity and ethmoid sinus metastasis.


Ultrasonography | 2018

Interobserver agreements in breast ultrasound categorization in Mammography and Ultrasonography Study for Breast Cancer Screening Effectiveness (MUST-BE) trial: results of a preliminary study

Eun Jung Choi; Eun Hye Lee; You Me Kim; Yun-Woo Chang; Jin Hwa Lee; Young Mi Park; Keum Won Kim; Young Joong Kim; Jae Kwan Jun; Seri Hong

Purpose The purpose of this study was to record and evaluate interobserver agreement as quality control for the modified categorization of screening breast ultrasound developed by the Alliance for Breast Cancer Screening in Korea (ABCS-K) for the Mammography and Ultrasonography Study for Breast Cancer Screening Effectiveness (MUST-BE) trial. Methods Eight breast radiologists with 4-16 years of experience participated in 2 rounds of quality control testing for the MUST-BE trial. Two investigators randomly selected 125 and 100 cases of breast lesions with different ratios of malignant and benign lesions. Two versions of the modified categorization were tested. The initially modified classification was developed after the first quality control workshop, and the re-modified classification was developed after the second workshop. The re-modified categorization established by ABCS-K added size criteria and the anterior-posterior ratio compared with the initially modified classification. After a brief lecture on the modified categorization system prior to each quality control test, the eight radiologists independently categorized the lesions using the modified categorization. Interobserver agreement was measured using kappa statistics. Results The overall kappa values for the modified categorizations indicated moderate to substantial degrees of agreement (initially modified categorization and re-modified categorization: κ=0.52 and κ=0.63, respectively). The kappa values for the subcategories of category 4 were 0.37 (95% confidence interval [CI], 0.24 to 0.52) and 0.39 (95% CI, 0.31 to 0.49), respectively. The overall kappa values for both the initially modified categorization and the re-modified categorization indicated a substantial degree of agreement when dichotomizing the interpretation as benign or suspicious. Conclusion The preliminary results demonstrated acceptable interobserver agreement for the modified categorization.


Korean Journal of Radiology | 2018

Low Tube Voltage CT Urography using Low Concentration Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial for Comparison with Conventional CT Urography

Sang Youn Kim; Jeong Yeon Cho; Joongyub Lee; Sung Il Hwang; Min Hoan Moon; Eun Ju Lee; Seong Sook Hong; Chan Kyo Kim; Kyeong Ah Kim; Sung Bin Park; Deuk Jae Sung; Yongsoo Kim; You Me Kim; Sung Il Jung; Sung Eun Rha; Dong Won Kim; Hyun Lee; Youngsup Shim; Inpyeong Hwang; Sungmin Woo; Hyuck Jae Choi

Objective To compare the image quality of low-tube-voltage and low-iodine-concentration-contrast-medium (LVLC) computed tomography urography (CTU) with iterative reconstruction (IR) with that of conventional CTU. Materials and Methods This prospective, multi-institutional, randomized controlled trial was performed at 16 hospitals using CT scanners from various vendors. Patients were randomly assigned to the following groups: 1) the LVLC-CTU (80 kVp and 240 mgI/mL) with IR group and 2) the conventional CTU (120 kVp and 350 mgI/mL) with filtered-back projection group. The overall diagnostic acceptability, sharpness, and noise were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) in the urinary tract were evaluated. Results The study included 299 patients (LVLC-CTU group: 150 patients; conventional CTU group: 149 patients). The LVLC-CTU group had a significantly lower effective radiation dose (5.73 ± 4.04 vs. 8.43 ± 4.38 mSv) compared to the conventional CTU group. LVLC-CTU showed at least standard diagnostic acceptability (score ≥ 3), but it was non-inferior when compared to conventional CTU. The mean attenuation value, mean SNR, CNR, and FOM in all pre-defined segments of the urinary tract were significantly higher in the LVLC-CTU group than in the conventional CTU group. Conclusion The diagnostic acceptability and quantitative image quality of LVLC-CTU with IR are not inferior to those of conventional CTU. Additionally, LVLC-CTU with IR is beneficial because both radiation exposure and total iodine load are reduced.


Ultrasonography | 2016

Validation of the fifth edition BI-RADS ultrasound lexicon with comparison of fourth and fifth edition diagnostic performance using video clips

Jung Hyun Yoon; Min Jung Kim; Hye Sun Lee; Sung Hun Kim; Ji Hyun Youk; Sun Hye Jeong; You Me Kim

Purpose The aim of this study was to evaluate the positive predictive value (PPV) and the diagnostic performance of the ultrasonographic descriptors in the fifth edition of BI-RADS, comparing with the fourth edition using video clips. Methods From September 2013 to July 2014, 80 breast masses in 74 women (mean age, 47.5±10.7 years) from five institutions of the Korean Society of Breast Imaging were included. Two radiologists individually reviewed the static and video images and analyzed the images according to the fourth and fifth edition of BI-RADS. The PPV of each descriptor was calculated and diagnostic performances between the fourth and fifth editions were compared. Results Of the 80 breast masses, 51 (63.8%) were benign and 29 (36.2%) were malignant. Suspicious ultrasonographic features such as irregular shape, non-parallel orientation, angular or spiculated margins, and combined posterior features showed higher PPV in both editions (all P<0.05). No significant differences were found in the diagnostic performances between the two editions (all P>0.05). The area under the receiver operating characteristics curve was higher in the fourth edition (0.708 to 0.690), without significance (P=0.416). Conclusion The fifth edition of the BI-RADS ultrasound lexicon showed comparable performance to the fourth edition and can be useful in the differential diagnosis of breast masses using ultrasonography.


Journal of The Korean Society of Coloproctology | 2015

Colonic Metastasis Presenting as an Intraluminal Fungating Mass 8 Years After Surgery for Ovarian Cancer.

Jeong Rye Kim; Bong Man Kim; You Me Kim; Won Ae Lee; Hwan Namgung

We report a case of colonic metastasis from ovarian cancer presented as an intraluminal fungating mass mimicking primary colon cancer 8 years after surgery for ovarian cancer. A 70-year-old woman presented with constipation. She had undergone an extended total abdominal hysterectomy with bilateral salpingo-oophorectomy for an ovarian papillary serous cystadenocarcinoma 8 years earlier. Colonoscopy showed a large fungating mass 10 cm from the anal verge that was suspected to be colorectal cancer. A computed tomography scan showed a bulky intraluminal fungating mass in the rectosigmoid junction. After a lower anterior resection and a pathologic diagnosis, a diagnosis of a papillary serous adenocarcinoma due to metastasis from an ovarian tumor was made for this patient.


Korean Journal of Radiology | 2014

The Efficacy of Mammography Boot Camp to Improve the Performance of Radiologists

Eun Hye Lee; Jae Kwan Jun; Seung Eun Jung; You Me Kim; Nami Choi


Ultrasound in Medicine and Biology | 2016

Comparison of Inter-Observer Variability and Diagnostic Performance of the Fifth Edition of BI-RADS for Breast Ultrasound of Static versus Video Images

Ji Hyun Youk; Inkyung Jung; Jung Hyun Yoon; Sung Hun Kim; You Me Kim; Eun Hye Lee; Sun Hye Jeong; Min Jung Kim

Collaboration


Dive into the You Me Kim's collaboration.

Top Co-Authors

Avatar

Eun Hye Lee

Soonchunhyang University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Sun Hye Jeong

Soonchunhyang University

View shared research outputs
Top Co-Authors

Avatar

Sung Hun Kim

Catholic University of Korea

View shared research outputs
Top Co-Authors

Avatar

Eun Jung Choi

Chonbuk National University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge