Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Yusaku Fukumoto is active.

Publication


Featured researches published by Yusaku Fukumoto.


Journal of the American College of Cardiology | 2008

Localized elevation of shear stress is related to coronary plaque rupture: a 3-dimensional intravascular ultrasound study with in-vivo color mapping of shear stress distribution.

Yusaku Fukumoto; Takafumi Hiro; Takashi Fujii; Genta Hashimoto; Tatsuhiro Fujimura; Jutaro Yamada; Takayuki Okamura; Masunori Matsuzaki

OBJECTIVES The purpose of the present study was to assess the relationship between shear stress distribution and coronary plaque rupture by means of a new color-mapping program of shear stress with 3-dimensional intravascular ultrasound (IVUS). BACKGROUND Various in-vitro studies have demonstrated that shear stress of the vascular lumen is one of the important determinants of coronary plaque vulnerability. However, the in-vivo relationship between shear stress and plaque rupture is still unclear. METHODS In the present study, 3-dimensional IVUS was used to obtain spatial information on luminal geometry from 20 patients with acute coronary syndrome having a distinct ulcerative lesion. These 3-dimensional contours for each lumen were first reconstructed into mesh polygons, and then analyzed by means of a program for calculating the fluid dynamics. The flow was considered to be a constant laminar one. Then, colorized mappings of the distribution of the streamline, blood pressure, and shear stress were performed. The original luminal contour for each ruptured lesion was obtained by smoothing and extrapolation. RESULTS All patients had a coronary plaque rupture in the proximal or top portion of the plaque hill. In the color mapping, localized elevation of blood pressure and shear stress could be observed on each plaque surface. The shear stress concentration was frequently correlated with the plaque rupture site (kappa = 0.79). CONCLUSIONS Although the absolute value of shear stress is not sufficient to directly provoke mechanical destruction of the fibrous cap, localized high shear stress might be a trigger of fibrous cap rupture.


Journal of Cardiology | 2008

Late giant coronary aneurysm associated with a fracture of sirolimus eluting stent: A case report

Takayuki Okamura; Takafumi Hiro; Takashi Fujii; Jutaro Yamada; Yusaku Fukumoto; Genta Hashimoto; Tatsuhiro Fujimura; Kyounori Yasumoto; Masunori Matsuzaki

A 73-year-old female underwent percutaneous coronary intervention (PCI) because of stable angina. An elective PCI for the RCA lesion was first performed with deploying sirolimus eluting stents (SES). Three weeks later, PCI was also provided in the residual LAD lesion. Eight months later, she presented with new angina. CAG revealed an in-stent restenosis in the mid LAD and a large eccentric saccular coronary aneurysm (17 mm x 9 mm) at the proximal RCA. Intravascular ultrasound (IVUS) showed absence of stent struts around the orifice of aneurysm, which suggested a fracture of SES stent. The entry of coronary aneurysm was finally sealed with a polytetrafluoroethylene-covered stent. This report documented a rare case of late giant coronary artery aneurysm associated with a fracture of SES.


Journal of the American College of Cardiology | 2005

Longitudinal structural determinants of atherosclerotic plaque vulnerability: a computational analysis of stress distribution using vessel models and three-dimensional intravascular ultrasound imaging.

Koji Imoto; Takafumi Hiro; Takashi Fujii; Akihiro Murashige; Yusaku Fukumoto; Genta Hashimoto; Takayuki Okamura; Jutaro Yamada; Koji Mori; Masunori Matsuzaki


Journal of the American College of Cardiology | 2005

Detection of lipid-laden atherosclerotic plaque by wavelet analysis of radiofrequency intravascular ultrasound signals : In vitro validation and preliminary in vivo application

Akihiro Murashige; Takafumi Hiro; Takashi Fujii; Koji Imoto; Takashige Murata; Yusaku Fukumoto; Masunori Matsuzaki


Circulation | 2012

Abstract 13103: Fusion Imaging of Intravascular Ultrasound and Multi-Detector Computed Tomography: A Novel Technique of Tissue Characterization of Coronary Plaques

Yusaku Fukumoto; Yuji Kamikawa; Takafumi Hiro


Archive | 2010

Three-Dimensional Intravascular Ultrasound Imaging A Computational Analysis of Stress Distribution Using Vessel Models and Longitudinal Structural Determinants of Atherosclerotic Plaque Vulnerability:

Genta Hashimoto; Takayuki Okamura; Jutaro Yamada; Koji Mori; Masunori Koji Imoto; Takafumi Hiro; Takashi Fujii; Akihiro Murashige; Yusaku Fukumoto


Japanese Circulation Journal-english Edition | 2008

OJ-179 Asymmetrical Distribution of Shear Stress is Related to Positive Remodeling in Coronary Atheroscletosis. : In-Vivo Serial Observation with Intravascular Ultrasound.(Intravascular endoscopy / Intravascular ultrasound(02)(I),Oral Presentation (Japanese),The 72nd Annual Scientific Meeting of the Japanese Circulation Society)

Yusaku Fukumoto; Takafumi Hiro; Takashi Fujii; Mitsuyuki Hiromoto; Masakazu Tanaka; Michio Yamada; Masunori Matsuzaki


Japanese Circulation Journal-english Edition | 2007

PJ-388 Color-Coded Dual-frequency Intravascular Ultrasound Imaging with use of Radio-frequency Ultrasound Signals : Novel Modality of Tissue Characterization of Coronary Plaque(Intravascular endoscopy/Intravascular ultrasound-6, The 71st Annual Scientific Meeting of the Japanese Circulation Society)

Genta Hashimoto; Takafumi Hiro; Takashi Fujii; Takayuki Okamura; Jutaro Yamada; Yusaku Fukumoto; Tatsuhiro Fujimura; Masunori Matsuzaki


Circulation | 2007

Abstract 3327: Asymmetrical Distribution of Shear Stress is Related to Positive Remodeling in Coronary Atheroscletosis. : In Vivo Serial Observation with Three-dimensional Intravascular Ultrasound.

Yusaku Fukumoto; Takafumi Hiro; Takashi Fujii; Mitsuyuki Hiromoto; Masakazu Tanaka; Masunori Matsuzaki


Circulation | 2007

Abstract 1635: In Vivo Color Mapping Of Shear Stress Along Coronary Arterial Lumen With Multi-detector Computed Tomography

Yusaku Fukumoto; Takafumi Hiro; Takashi Fujii; Mitsuyuki Hiromoto; Masakazu Tanaka; Michio Yamada; Masunori Matsuzaki

Collaboration


Dive into the Yusaku Fukumoto's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge