Publication


Featured researches published by Z Grelewicz.


Medical Physics | 2013

Spatial and temporal performance of 3D optical surface imaging for real‐time head position tracking

R Wiersma; S. L. Tomarken; Z Grelewicz; Ah Belcher; H Kang

PURPOSE The spatial and temporal tracking performance of a commercially available 3D optical surface imaging system is evaluated for its potential use in frameless stereotactic radiosurgery head tracking applications. METHODS Both 3D surface and infrared (IR) marker tracking were performed simultaneously on a head phantom mounted on an xyz motion stage and on four human subjects. To allow spatial and temporal comparison on human subjects, three points were simultaneously monitored, including the upper facial region (3D surface), a dental plate (IR markers), and upper forehead (IR markers). RESULTS For both static and dynamic phantom studies, the 3D surface tracker was found to have a root mean squared error (RMSE) of approximately 0.30 mm for region-of-interest (ROI) surface sizes greater than 1000 vertex points. Although, the processing period (1/fps) of the 3D surface system was found to linearly increase as a function of the number of ROI vertex points, the tracking accuracy was found to be independent of ROI size provided that the ROI was sufficiently large and contained features for registration. For human subjects, the RMSE between 3D surface tracking and IR marker tracking modalities was 0.22 mm left-right (x-axis), 0.44 mm superior-inferior (y-axis), 0.27 mm anterior-posterior (z-axis), 0.29° pitch (around x-axis), 0.18° roll (around y-axis), and 0.15° yaw (around z-axis). CONCLUSIONS 3D surface imaging has the potential to provide submillimeter level head motion tracking. This is provided that a highly accurate camera-to-LINAC frame of reference calibration can be performed and that the reference ROI is of sufficient size and contains suitable surface features for registration.


Medical Physics | 2014

Development of a 6DOF robotic motion phantom for radiation therapy.

Ah Belcher; X Liu; Z Grelewicz; Erik Pearson; R Wiersma

PURPOSE The use of medical technology capable of tracking patient motion or positioning patients along 6 degree-of-freedom (6DOF) has steadily increased in the field of radiation therapy. However, due to the complex nature of tracking and performing 6DOF motion, it is critical that such technology is properly verified to be operating within specifications in order to ensure patient safety. In this study, a robotic motion phantom is presented that can be programmed to perform highly accurate motion along any X (left-right), Y (superior-inferior), Z (anterior-posterior), pitch (around X), roll (around Y), and yaw (around Z) axes. In addition, highly synchronized motion along all axes can be performed in order to simulate the dynamic motion of a tumor in 6D. The accuracy and reproducibility of this 6D motion were characterized. METHODS An in-house designed and built 6D robotic motion phantom was constructed following the Stewart-Gough parallel kinematics platform archetype. The device was controlled using an inverse kinematics formulation, and precise movements in all 6 degrees-of-freedom (X, Y, Z, pitch, roll, and yaw) were performed, both simultaneously and separately for each degree-of-freedom. Additionally, previously recorded 6D cranial and prostate motions were effectively executed. The robotic phantom movements were verified using a 15 fps 6D infrared marker tracking system and the measured trajectories were compared quantitatively to the intended input trajectories. The workspace, maximum 6D velocity, backlash, and weight load capabilities of the system were also established. RESULTS Evaluation of the 6D platform demonstrated translational root mean square error (RMSE) values of 0.14, 0.22, and 0.08 mm over 20 mm in X and Y and 10 mm in Z, respectively, and rotational RMSE values of 0.16°, 0.06°, and 0.08° over 10° of pitch, roll, and yaw, respectively. The robotic stage also effectively performed controlled 6D motions, as well as reproduced cranial trajectories over 15 min, with a maximal RMSE of 0.04 mm translationally and 0.04° rotationally, and a prostate trajectory over 2 min, with a maximal RMSE of 0.06 mm translationally and 0.04° rotationally. CONCLUSIONS This 6D robotic phantom has proven to be accurate under clinical standards and capable of reproducing tumor motion in 6D. Such functionality makes the robotic phantom usable for either quality assurance or research purposes.


Medical Physics | 2012

An EPID based method for performing high accuracy calibration between an optical external marker tracking device and the LINAC reference frame

Z Grelewicz; H Kang; R Wiersma

PURPOSE With the increasing use of external 3D optical tracking cameras to guide modern radiation therapy procedures, it has become vitally important to have an accurate camera to linear accelerator (LINAC) reference frame calibration. To eliminate errors present in current calibration procedures based on the manual hand alignment of a device using the light field crosshairs and in room guidance lasers, a semiautomated quantitative calibration approach requiring only use of an electronic portal imaging device (EPID) was developed. METHODS A phantom comprised of seven highly IR reflective plastic BBs was placed on the LINAC treatment couch and imaged with both a 3D stereoscopic IR imager and the on board megavoltage (MV) EPID imager. Having knowledge of the optically determined 3D positions and projected EPID images of the BBs, simulated annealing was used to optimize the location of the BBs in the LINAC frame using four different optimization functions. Singular value decomposition was then used to calculate the transformation matrix between the camera and LINAC reference frames. Results were then compared to a traditional camera calibration method for overall accuracy. RESULTS Using modeled data, the simulated annealing process was able to determine the actual locations of the BBs with a RMSE of 0.23 mm. Using projection images acquired with an MV imager, the process was able to determine locations of BBs within .26 mm. The results depend on the choice of optimization function. CONCLUSIONS Results show that the method can be used to provide highly accurate spatial registration between an external 3D imaging reference frame and the LINAC frame. The experimental MV imager results, while not as precise as the simulated results, exceed 1 mm accuracy and the current accepted AAPM TG-142 standard of ≤2 mm positioning accuracy.


Medical Physics | 2012

Development of an automated region of interest selection method for 3D surface monitoring of head motion.

H Kang; Z Grelewicz; R Wiersma

PURPOSE To simplify the often complex and user-dependent manual region of interest (ROI) selection process for head motion monitoring, an automatic ROI selection method was developed. METHODS The automatic ROI selection algorithm calculated the displacements and velocities of 3D surface points between a temporally correlated 3D image series and a reference image. Only facial surfaces satisfying certain spatial and temporal criteria were selected. The algorithm was tested on five healthy volunteers instructed to perform different types of facial movements for a total of 27 real-time image sets (40-120 images for each image set). RESULTS The algorithm detected and excluded surface areas affected by different types of local facial movements that were independent of actual net head motion. Eye, eyebrow, and mandible motion were most commonly detected as being independent of head motion and were excluded from the final ROI. For 3D images taken with substantial facial or whole head motion, either most of the facial area was excluded or only small areas with random patterns were included in the final ROI. Surface image registration using iterative closest point (ICP) methods showed more stable real-time head tracking using the automatically selected ROI than manual user defined ROIs. CONCLUSIONS The automatic selection method successfully found ROIs stable over time for tracking head motion by excluding locally varying facial motions. By automating the ROI selection process, it is feasible that the time and complexity of current ROI definition can be reduced, together with user-dependent registration errors.


Medical Physics | 2017

Use of proximal operator graph solver for radiation therapy inverse treatment planning

X Liu; Charles A. Pelizzari; Ah Belcher; Z Grelewicz; R Wiersma

Purpose Most radiation therapy optimization problems can be formulated as an unconstrained problem and solved efficiently by quasi‐Newton methods such as the Limited‐memory Broyden‐Fletcher‐Goldfarb‐Shanno (L‐BFGS) algorithm. However, several next generation planning techniques such as total variation regularization‐ based optimization and MV+kV optimization, involve constrained or mixed‐norm optimization, and cannot be solved by quasi‐Newton methods. Using standard optimization algorithms on such problems often leads to prohibitively long optimization times and large memory requirements. This work investigates the use of a recently developed proximal operator graph solver (POGS) in solving such radiation therapy optimization problems. Methods Radiation therapy inverse treatment planning was formulated as a graph form problem, and the proximal operators of POGS for quadratic optimization were derived. POGS was exploited for the first time to impose hard dose constraints along with soft constraints in the objective function. The solver was applied to several clinical treatment sites (TG119, liver, prostate, and head&neck), and the results were compared to the solutions obtained by other commercial and non‐commercial optimizers. Results For inverse planning optimization with nonnegativity box constraints on beamlet intensity, the speed of POGS can compete with that of LBFGSB in some situations. For constrained and mixed‐norm optimization, POGS is about one or two orders of magnitude faster than the other solvers while requiring less computer memory. Conclusions POGS was used for solving inverse treatment planning problems involving constrained or mixed‐norm formulation on several example sites. This approach was found to improve upon standard solvers in terms of computation speed and memory usage, and is capable of solving traditionally difficult problems, such as total variation regularization‐based optimization and combined MV+kV optimization.


Medical Physics | 2016

Spatial and rotational quality assurance of 6DOF patient tracking systems

Ah Belcher; X Liu; Z Grelewicz; R Wiersma

PURPOSE External tracking systems used for patient positioning and motion monitoring during radiotherapy are now capable of detecting both translations and rotations. In this work, the authors develop a novel technique to evaluate the 6 degree of freedom 6(DOF) (translations and rotations) performance of external motion tracking systems. The authors apply this methodology to an infrared marker tracking system and two 3D optical surface mapping systems in a common tumor 6DOF workspace. METHODS An in-house designed and built 6DOF parallel kinematics robotic motion phantom was used to perform motions with sub-millimeter and subdegree accuracy in a 6DOF workspace. An infrared marker tracking system was first used to validate a calibration algorithm which associates the motion phantom coordinate frame to the camera frame. The 6DOF positions of the mobile robotic system in this space were then tracked and recorded independently by an optical surface tracking system after a cranial phantom was rigidly fixed to the moveable platform of the robotic stage. The calibration methodology was first employed, followed by a comprehensive 6DOF trajectory evaluation, which spanned a full range of positions and orientations in a 20 × 20 × 16 mm and 5° × 5° × 5° workspace. The intended input motions were compared to the calibrated 6DOF measured points. RESULTS The technique found the accuracy of the infrared (IR) marker tracking system to have maximal root-mean square error (RMSE) values of 0.18, 0.25, 0.07 mm, 0.05°, 0.05°, and 0.09° in left-right (LR), superior-inferior (SI), anterior-posterior (AP), pitch, roll, and yaw, respectively, comparing the intended 6DOF position and the measured position by the IR camera. Similarly, the 6DOF RSME discrepancy for the HD optical surface tracker yielded maximal values of 0.46, 0.60, 0.54 mm, 0.06°, 0.11°, and 0.08° in LR, SI, AP, pitch, roll, and yaw, respectively, over the same 6DOF evaluative workspace. An earlier generation 3D optical surface tracking unit was observed to have worse tracking capabilities than both the IR camera unit and the newer 3D surface tracking system with maximal RMSE of 0.69, 0.74, 0.47 mm, 0.28°, 0.19°, and 0.18°, in LR, SI, AP, pitch, roll, and yaw, respectively, in the same 6DOF evaluation space. CONCLUSIONS The proposed technique was found to be effective at evaluating the performance of 6DOF patient tracking systems. All observed optical tracking systems were found to exhibit tracking capabilities at the sub-millimeter and subdegree level within a 6DOF workspace.


advances in computing and communications | 2015

Robotic stage for head motion correction in stereotactic radiosurgery

X Liu; Ah Belcher; Z Grelewicz; R Wiersma

A novel 4 Degree-of-freedom (4D) robotic system was developed to correct both translational and rotational head motion deviations during image-guided stereotactic radiosurgery procedures. The correction was non-invasive, and was performed in real-time with high positioning accuracy. An optical system was used for real-time 6D head position tracking, and a decoupling control law was designed to control the 4D stage for the motion correction in xyz direction and pitch angle. Both experiments on an phantom and volunteers was used to demonstrate the control performance. With motion correction, on average, over 99% of the time the translational error was within 0.5 mm, and the pitch angle error was within 0.2 degrees.


Medical Physics | 2015

Robotic real-time translational and rotational head motion correction during frameless stereotactic radiosurgery

X Liu; Ah Belcher; Z Grelewicz; R Wiersma

PURPOSE To develop a control system to correct both translational and rotational head motion deviations in real-time during frameless stereotactic radiosurgery (SRS). METHODS A novel feedback control with a feed-forward algorithm was utilized to correct for the coupling of translation and rotation present in serial kinematic robotic systems. Input parameters for the algorithm include the real-time 6DOF target position, the frame pitch pivot point to target distance constant, and the translational and angular Linac beam off (gating) tolerance constants for patient safety. Testing of the algorithm was done using a 4D (XY Z + pitch) robotic stage, an infrared head position sensing unit and a control computer. The measured head position signal was processed and a resulting command was sent to the interface of a four-axis motor controller, through which four stepper motors were driven to perform motion compensation. RESULTS The control of the translation of a brain target was decoupled with the control of the rotation. For a phantom study, the corrected position was within a translational displacement of 0.35 mm and a pitch displacement of 0.15° 100% of the time. For a volunteer study, the corrected position was within displacements of 0.4 mm and 0.2° over 98.5% of the time, while it was 10.7% without correction. CONCLUSIONS The authors report a control design approach for both translational and rotational head motion correction. The experiments demonstrated that control performance of the 4D robotic stage meets the submillimeter and subdegree accuracy required by SRS.


advances in computing and communications | 2016

Constrained quadratic optimization for radiation treatment planning by use of graph form ADMM

X Liu; Ah Belcher; Z Grelewicz; R Wiersma

The alternating direction method of multipliers (ADMM) is applied to constrained quadratic optimization of intensity-modulated radiation therapy (IMRT) planning. The proximal operator for the ADMM algorithm is developed, and the algorithm is applied to different clinical treatment sites (liver, prostate, and head & neck). The results are compared with the solutions obtained by several other commercial and non-commercial optimizers. The ADMM solver is about one to two orders of magnitude faster than the other solvers, moreover, it requires less computer memory.


Medical Physics | 2018

Use of a laser-guided collimation system to perform direct kilovoltage x-ray spectra measurements on a linear accelerator onboard imager

Z Grelewicz; Ah Belcher; R Wiersma

PURPOSE The increased use of image-guided radiation therapy (IGRT) has led to increased use of kV on board imaging (OBI) devices. At present, directly measured OBI beam quality data have only been reported in terms of half-value layers (HVL). However, the HVL metric alone does not give the full OBI energy spectra as needed for accurate beam modeling. Although direct kV spectrometer devices exist they typically suffer from detector pile-up when used with OBI sources. We therefore present, for the first time, a novel laser-guided collimation system that allows direct measurement of the full energy spectrum for clinical OBI systems. METHODS Several clinically relevant spectra (80, 100, and 125 kVp), with and without the half bow-tie filter, were measured using a thermoelectric cooled cadmium telluride (CdTe) detector paired with a multichannel analyzer. To prevent detector saturation, the photon flux at the detector was reduced by use of an in-house designed laser-guided collimation system. After applying energy bin corrections, direct spectroscopic measurements were compared to Monte Carlo (MC) simulated spectra in order to verify accuracy of collected data. Both percent depth dose (PDD) curves and digitally reconstructed radiographs (DRR) were compared using the measured vs MC spectra. RESULTS Measured and MC spectra agree with RMSD between 1.96% and 3.29%. PDD curves generated from the measured and MC spectra were found to match except for in the small buildup region, with an overall match for the six beams ranging between 0.3% and 2.7% RMSD. DRRs matched well with a maximum difference in contrast of 1.1% and RMSD of 0.46% contrast for various materials in DRRs. CONCLUSIONS The use of a laser-guided collimation system provided a method for quickly obtaining highly accurate kV spectrum data from OBI sources. For kV dose or DRR calculation, it was found that both spectra produced similar results.

Collaboration


Dive into the Z Grelewicz's collaboration.

Top Co-Authors

Avatar

R Wiersma

University of Chicago

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

X Liu

University of Chicago

View shared research outputs
Top Co-Authors

Avatar

H Kang

University of Chicago

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Parham Alaei

University of Minnesota

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Don C. Rockey

University of Texas Southwestern Medical Center

View shared research outputs
Researchain Logo
Decentralizing Knowledge