Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Z. Zhang is active.

Publication


Featured researches published by Z. Zhang.


Classical and Quantum Gravity | 1997

The Virgo interferometer

B. Caron; A. Dominjon; C. Drezen; R. Flaminio; X. Grave; F. Marion; L. Massonnet; C. Mehmel; R. Morand; B. Mours; V. Sannibale; M. Yvert; D. Babusci; S. Bellucci; S. Candusso; G. Giordano; G. Matone; J.-M. Mackowski; L. Pinard; F. Barone; E. Calloni; L. Di Fiore; M. Flagiello; F. Garufi; A. Grado; Maurizio Longo; M. Lops; S. Marano; L. Milano; S. Solimeno

The Virgo gravitational wave detector is an interferometer with 3 km long arms in construction near Pisa to be commissioned in the year 2000. Virgo has been designed to achieve a strain sensitivity of a few times at 200 Hz. A large effort has gone into the conception of the mirror suspension system, which is expected to reduce noise to the level of at 10 Hz. The expected signals and main sources of noise are briefly discussed; the choices made are illustrated together with the present status of the experiment.


Review of Scientific Instruments | 2001

Measurement of the VIRGO superattenuator performance for seismic noise suppression

G. Ballardin; L. Bracci; S. Braccini; C. Bradaschia; C. Casciano; G. Calamai; R. Cavalieri; R. Cecchi; G. Cella; Elena Cuoco; E. D’Ambrosio; V. Dattilo; A. Di Virgilio; L. Fabbroni; F. Fidecaro; F. Frasconi; A. Gaddi; A. Gennai; G. Gennaro; A. Giazotto; G. Losurdo; L. Holloway; P. La Penna; F. Lelli; E. Majorana; M. Mazzoni; F. Paoletti; M. Pasotti; A. Pasqualetti; R. Passaquieti

Below a few tens of hertz interferometric detection of gravitational waves is masked by seismic vibrations of the optical components. In order to isolate the mirrors of the VIRGO interferometer, a sophisticated suspension system, called superattenuator, has been developed. Its working principle is based on a multistage pendulum acting on seismic vibrations as a chain of second order mechanical low-pass filters. A complete superattenuator has been built and tested. This apparatus allows extending the VIRGO detection band down to a few Hz. A detailed description of the attenuation system and its performance are presented in this article.


Review of Scientific Instruments | 1999

An inverted pendulum preisolator stage for the VIRGO suspension system

G. Losurdo; M. Bernardini; S. Braccini; C. Bradaschia; C. Casciano; V. Dattilo; R. De Salvo; A. Di Virgilio; F. Frasconi; A. Gaddi; A. Gennai; A. Giazotto; Hb Pan; F. Paoletti; A. Pasqualetti; R. Passaquieti; D. Passuello; R. Taddei; Z. Zhang; G. Cella; Elena Cuoco; E. D’Ambrosio; F. Fidecaro; S. Gaggero; P. La Penna; S. Mancini; R. Poggiani; A. Viceré; M. Mazzoni; R. Stanga

The design of a new preisolator stage for the VIRGO superattenuator is presented. The device is essentially a 6 m high inverted pendulum with horizontal resonant frequency of 30 mHz. An isolation of 65 dB at 1 Hz has been achieved. Very low forces are needed to move the whole superattenuator acting on the inverted pendulum. For this reason, the system is a suitable platform for the active control of the mirror suspension.


Review of Scientific Instruments | 2001

Inertial control of the mirror suspensions of the VIRGO interferometer for gravitational wave detection

G. Losurdo; G. Calamai; Elena Cuoco; L. Fabbroni; G. Guidi; M. Mazzoni; R. Stanga; F. Vetrano; L. Holloway; D. Passuello; G. Ballardin; S. Braccini; C. Bradaschia; R. Cavalieri; R. Cecchi; G. Cella; V. Dattilo; A. Di Virgilio; F. Fidecaro; F. Frasconi; A. Gennai; A. Giazotto; I. Ferrante; P. La Penna; F. Lelli; T. Lomtadze; A. Marin; S. Mancini; F. Paoletti; A. Pasqualetti

In order to achieve full detection sensitivity at low frequencies, the mirrors of interferometric gravitational wave detectors must be isolated from seismic noise. The VIRGO vibration isolator, called the superattenuator, is fully effective at frequencies above 4 Hz. But the residual motion of the mirror at the mechanical resonant frequencies of the system is too large for the interferometer locking system and must be damped. A multidimensional feedback system, using inertial sensors and digital processing, has been designed for this purpose. An experimental procedure for determining the feedback control of the system has been defined. In this article a full description of the system is given and experimental results are presented.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1997

Extending the VIRGO gravitational wave detection band down to a few Hz: metal blade springs and magnetic antisprings

M. Beccaria; M. Bernardini; E. Bougleux; S. Braccini; C. Bradaschia; C. Casciano; G. Cella; E. Cuoco; E. D'Ambrosio; G. De Carolis; R. Del Fabbro; R. De Salvo; A. Di Virgilio; I. Ferrante; F. Fidecaro; R. Flaminio; A. Gaddi; A. Gennai; G. Gennaro; A. Giazotto; L. Holloway; P. La Penna; G. Losurdo; S. Malik; S. Mancini; J. Nicolas; F. Palla; Hb Pan; F. Paoletti; A. Pasqualetti

Abstract The detection band of the interferometric gravitational wave detector VIRGO can be extended down to a few Hz by suspending each optical component of the interferometer from a chain of mechanical filters designed to suppress the transmission of seismic vibrations. Each mechanical filter supports the weight of the stages below it through a set of cantilevered blade springs. A system of permanent magnets, providing an “antispring” force, helps to reduce the highest vertical resonance of the chain from 7 Hz to about 2 Hz. This improvement allows VIRGO to reduce the frequency detection threshold from 10 Hz to about 4 Hz. A characterization of the mechanical filters is provided in this paper.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1998

THE CREEP PROBLEM IN THE VIRGO SUSPENSIONS : A POSSIBLE SOLUTION USING MARAGING STEEL

M. Beccaria; M. Bernardini; S. Braccini; C. Bradaschia; G. Cagnoli; C. Casciano; G. Cella; E. Cuoco; V. Dattilo; G. De Carolis; R. De Salvo; A. Di Virgilio; G. Feng; I. Ferrante; F. Fidecaro; F. Frasconi; A. Gaddi; L. Gammaitoni; A. Gennai; A. Giazotto; L. Holloway; J. Kovalik; P. La Penna; G. Losurdo; S. Malik; S. Mancini; F. Marchesoni; J. Nicolas; F. Palla; Hb Pan

Abstract Each optical component of the interferometric gravitational wave detector VIRGO is suspended from a cascade of mechanical filters designed to suppress the transmission of seismic vibrations. Each mechanical filter supports the weight of the filters below it by means of a set of steel cantilever blade springs. The stress from the load acting on the blades was found to induce a drooping of the blade tips of several microns per day due to a series of microscopic yielding events (micro-creep). This process induces a mechanical displacement shot-noise on the optical component which can dominate the small displacements produced by gravitational waves. The use of a special precipitation hardened steel (Maraging C250), instead of common spring steel, allows the construction of blades that show an acceptable stability under stress.


Journal of Vacuum Science and Technology | 1998

Air bake-out to reduce hydrogen outgassing from stainless steel

M. Bernardini; S. Braccini; R. De Salvo; A. Di Virgilio; A. Gaddi; A. Gennai; G Genuini; A. Giazotto; G. Losurdo; Hb Pan; A. Pasqualetti; D. Passuello; P. Popolizio; F. Raffaelli; Gabriele Torelli; Z. Zhang; C. Bradaschia; R. Del Fabbro; I. Ferrante; F. Fidecaro; P. La Penna; S. Mancini; R. Poggiani; P Narducci; A. Solina; Renzo Valentini

Hydrogen outgassing is the most significant factor limiting the attainment of outgassing rates below 10−12u2009mbaru2009lu2009s−1u2009cm−2 in stainless steel vacuum systems. This limit turns out to be crucial in very large vacuum systems, like the VIRGO vacuum tubes (2 tubes 1.2 mu2009diam, 3000 mu2009length). Heating the raw material at 400u2009°C in air was suggested as a money saving alternative to the classical vacuum heating at 950u2009°C. We report the results of hydrogen content analysis performed on stainless steel samples submitted to different treatments, and also the measurement performed on a prototype tube (1.2-m-diam, 48-m-long). We concluded that air bake-out drives out most of the hydrogen absorbed in the bulk stainless steel, while the presence of an oxide layer does not reduce the hydrogen outgassing.


International Europhysics Conference on High Energy Physics HEP 93 | 1997

The Virgo Project

J.-Y. Vinet; F. Bondu; A. Brillet; F. Cleva; H. Heitmann; L. Latrach; N. Man; M. Pham Tu; M. Barsuglia; V. Brisson; F. Cavalier; M. Davier; P. Hello; P. Heusse; F. Lediberder; P. Marin; B. Caron; A. Dominjon; C. Drezen; R. Flaminio; X. Grave; F. Marion; L. Massonet; C. Mehmel; R. Morand; B. Mours; V. Sannibale; M. Yvert; L. Dognin; P. Ganau

The Virgo project is a Italian-French collaboration aiming at the construction of a long baseline interferometric antenna for the detection of gravitational radiation signals of cosmic origin. We describe the principles of the system, and high-light the technical challenges we need to overcome for reaching a sensitiity as low as 10−23Hz−1/2.The gravitational clustering of collisionless particles in an expanding universe is modelled using some simple physical ideas. I show that it is possible to understand the nonlinear clustering in terms of three well defined regimes: (1) linear regime; (2) quasilinear regime which is dominated by scale-invariant radial infall and (3) nonlinear regime dominated by nonradial motions and mergers. Modelling each of these regimes separately I show how the nonlinear two point correlation function can be related to the linear correlation function in hierarchical models. This analysis leads to results which are in good agreement with numerical simulations thereby providing an explanation for numerical results. Using this model and some simple extensions, it is possible to understand the transfer of power from large to small scales and the behaviour of higher order correlation functions. The ideas presented here will also serve as a powerful analytical tool to investigate nonlinear clustering in different models.


Review of Scientific Instruments | 2001

Measurement of the transfer function of the steering filter of the Virgo super attenuator suspension

G. Ballardin; S. Braccini; C. Bradaschia; C. Casciano; R. Cavalieri; R. Cecchi; V.S. Chickarmane; V. Dattilo; A. Di Virgilio; I. Ferrante; F. Fidecaro; F. Frasconi; A. Gaddi; A. Gennai; A. Giazotto; L. Holloway; T. Lomtazde; F. Paoletti; A. Pasqualetti; R. Passaquieti; D. Passuello; R. Poggiani; R. Taddei; A. Viceré; Z. Zhang; E. Cuoco; G. Losurdo; Wei-Tou Ni; Jeah-Sheng Wu; Chun-Hsiung Chang

The optical elements of the Virgo antenna are supported and isolated from seismic noise disturbances by super attenuator (SA) suspensions. The steering filter (SF) is a component of the SA, designed for the mirror control. The dynamical properties of the SF are described by transfer functions, which have been measured in order to define the control strategy; the results have made it possible to set and tune the parameters of a simulation of the SA. The measuring devices were linear voltage differential transducers: they were found to be quite effective and flexible in usage. An auto-regressive model was used to fit the experimental data, implementing the linear relation between the input forces and the resulting motion. The ability of the model to reproduce the experimental behavior was a clear indication of the good data quality, showing that the contaminating noise was under control. The simulation was able to reproduce the qualitative behavior, and the simulation parameters were estimated, with 10% and...


Journal of Heat Transfer-transactions of The Asme | 1999

Far-Infrared Transmittance and Reflectance of YBa2Cu3O7-δ Films on Si Substrates

Ajay Kumar; Z. Zhang; V. A. Boychev; D. B. Tanner; L. R. Vale; D. A. Rudman

The transmittance and reflectance of superconductive YBa 2 Cu 3 O 7-δ (YBCO) thin films deposited on Si substrates have been measured in the far-infrared frequency region from 10 to 100 cm -1 (wavelength from 1000 to 100 μm) at temperatures between 10 and 300 K. The effects of interference, optical resonance, and antireflection on the radiative properties of high-temperature superconducting (HTSC) films are observed and quantitatively analyzed. Furthermore, we have measured the reflectance of the HTSC film-substrate composites for radiation incident on the substrate side (backside reflectance) for the first time. The backside reflectance increases significantly from the normal state to the superconducting state at certain frequencies; this experimentally demonstrates that HTSC films can be used to build far-infrared intensity modulators. The complex refractive index of the YBCO films is determined from the measured transmittance using the Drude model in the normal state and a two-fluid model in the superconducting state. The complex refractive index obtained from this study is useful for various applications of YBCO films, including radiation modulators, detectors, and Fabry-Perot resonators.

Collaboration


Dive into the Z. Zhang's collaboration.

Top Co-Authors

Avatar

A. Di Virgilio

Istituto Nazionale di Fisica Nucleare

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

A. Pasqualetti

Istituto Nazionale di Fisica Nucleare

View shared research outputs
Top Co-Authors

Avatar

C. Bradaschia

Scuola Normale Superiore di Pisa

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

G. Losurdo

Istituto Nazionale di Fisica Nucleare

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

P. La Penna

Istituto Nazionale di Fisica Nucleare

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge