Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Zhaoping Cheng is active.

Publication


Featured researches published by Zhaoping Cheng.


PLOS ONE | 2014

Impact of Sinogram Affirmed Iterative Reconstruction (SAFIRE) Algorithm on Image Quality with 70 kVp-Tube-Voltage Dual-Source CT Angiography in Children with Congenital Heart Disease

Pei Nie; Haiou Li; Yanhua Duan; Ximing Wang; Xiaopeng Ji; Zhaoping Cheng; Anbiao Wang; Jiuhong Chen

Purpose To compare the image quality and diagnostic accuracy between sinogram affirmed iterative reconstruction (SAFIRE) algorithm and filtered back projection (FBP) reconstruction algorithm at 70 kVp-tube-voltage DSCT angiography in children with congenital heart disease (CHD). Materials and Methods Twenty-eight patients (mean age: 13 months; range: 2–48 months; male: 16; female: 12; mean weight: 8 kg) with CHD underwent 70 kVp DSCT angiography. Imaging data were reconstructed with both FBP and SAFIRE algorithms. Subjective image quality was evaluated on a five-point scale. The parameters of image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) on the objective image quality were compared for the two reconstruction algorithms. Surgery was performed in 20 patients, whereas conventional cardiac angiography (CCA) was performed in 8 patients. The diagnostic accuracy was evaluated on the surgical and/or CCA findings. The effective radiation doses were calculated. Results Compared to FBP algorithm, SAFIRE algorithm had significantly higher scores for subjective image quality (P<0.05), and lower image noise (P<0.05) as well as higher SNR &CNR values (P<0.05). There was no significant difference in the diagnostic accuracy between the FBP and SAFIRE algorithm (χ2 = 1.793, P>0.05). The mean effective dose for 70 kVp DSCT angiography was 0.30±0.13 mSv. Conclusions The SAFIRE algorithm can significantly reduce image noise and improve the image quality at 70 kVp DSCT angiography for the assessment of CHD in children.


Clinical Radiology | 2010

Detection of coronary artery anomalies by dual-source CT coronary angiography

Zhaoping Cheng; Xinpei Wang; Yanhua Duan; Lebin Wu; Dawei Wu; Changhu Liang; Changchun Liu; Zhuodong Xu

AIM To retrospectively evaluate the clinical value of dual-source computed tomography (DSCT) coronary angiography in the diagnosis of coronary artery anomalies. MATERIALS AND METHODS A large cohort of 3625 consecutive patients, who underwent DSCT coronary angiography in our institute, was reviewed for coronary artery anomalies. All images were evaluated by two experienced readers using axial source images, multi-planar reformations (MPR), maximum intensity projections (MIP) and volume rendering (VR). Coronary artery anomalies were found in 36 patients (male 20, female 16, mean age 48 years, range 15-76 years). Of the 36 patients, 19 patients also underwent conventional coronary angiography (CCA). RESULTS The incidence of coronary artery anomalies was 0.99% (36/3625). Six different types of coronary artery anomalies were diagnosed by DSCT coronary angiography: (1) 11 anomalies of the right coronary artery; (2) five anomalies of the left coronary artery; (3) 10 anomalies of the left circumflex artery; (4) two single coronary artery; (5) one anomalous pulmonary origin of the coronary artery; (6) seven coronary artery fistula. Evaluation of the CCA resulted in a precise diagnosis in 53% (10/19) patients. CONCLUSION DSCT coronary angiography is a good diagnostic tool to examine coronary artery anomalies.


PLOS ONE | 2014

Abdominal aortic intimal flap motion characterization in acute aortic dissection: assessed with retrospective ECG-gated thoracoabdominal aorta dual-source CT angiography.

Shifeng Yang; Xia Li; Baoting Chao; Lebin Wu; Zhaoping Cheng; Yanhua Duan; Dawei Wu; Yiqiang Zhan; Jiuhong Chen; Bo Liu; Xiaopeng Ji; Pei Nie; Ximing Wang

Objectives To evaluate the feasibility of dose-modulated retrospective ECG-gated thoracoabdominal aorta CT angiography (CTA) assessing abdominal aortic intimal flap motion and investigate the motion characteristics of intimal flap in acute aortic dissection (AAD). Materials and Methods 49 patients who had thoracoabdominal aorta retrospective ECG-gated CTA scan were enrolled. 20 datasets were reconstructed in 5% steps between 0 and 95% of the R-R interval in each case. The aortic intimal flap motion was assessed by measuring the short axis diameters of the true lumen and false lumen 2 cm above of celiac trunk ostium in different R-R intervals. Intimal flap motion and configuration was assessed by two independent observers. Results In these 49 patients, 37 had AAD, 7 had intramural hematoma, and 5 had negative result for acute aortic disorder. 620 datasets of 31 patients who showed double lumens in abdominal aorta were enrolled in evaluating intimal flap motion. The maximum and minimum true lumen diameter were 12.2±4.1 mm (range 2.6∼17.4) and 6.7±4.1 mm (range 0∼15.3) respectively. The range of intimal flap motion in all patients was 5.5±2.6 mm (range 1.8∼10.2). The extent of maximum true lumen diameter decreased during a cardiac cycle was 49.5%±23.5% (range 12%∼100%). The maximum motion phase of true lumen diameter was in systolic phase (5%∼40% of R-R interval). Maximum and minimum intimal flap motion was at 15% and 75% of the R-R interval respectively. Intimal flap configuration had correlation with the phase of cardiac cycle. Conclusions Abdominal intimal flap position and configuration varied greatly during a cardiac cycle. Retrospective ECG-gated thoracoabdominal aorta CTA can reflect the actual status of the true lumen and provide more information about true lumen collapse. This information may be helpful to diagnosis and differential diagnosis of dynamic abstraction.


PLOS ONE | 2014

Application of prospective ECG-gated high-pitch 128-slice dual-source CT angiography in the diagnosis of congenital extracardiac vascular anomalies in infants and children.

Pei Nie; Guangjie Yang; Ximing Wang; Yanhua Duan; Wenjian Xu; Haiou Li; Ting Cao; Xuejun Liu; Xiaopeng Ji; Zhaoping Cheng; Anbiao Wang

Purpose To investigate the value of prospective ECG-gated high-pitch 128-slice dual-source CT (DSCT) angiography in the diagnosis of congenital extracardiac vascular anomalies in infants and children in comparison with transthoracic echocardiography (TTE). Methods Eighty consecutive infants or children clinically diagnosed of congenital heart disease and suspected with extracardiac vascular anomaly were enrolled, and 75 patients were finally included in this prospective study. All patients underwent prospective ECG-gated high-pitch DSCT angiography after TTE with an interval of 1–7 days. The diagnostic accuracy and sensitivity of high-pitch DSCT angiography and TTE were compared according to the surgical/CCA findings. The image quality of DSCT was assessed using a five-point scale. The effective radiation dose (ED) was calculated. Results A total of 17 congenital heart diseases and 162 separate extracardiac vascular anomalies were confirmed by surgical/CCA findings in 75 patients. The diagnostic accuracy of high-pitch DSCT angiography and TTE was 99.67% and 97.89%, respectively. The sensitivity of high-pitch DSCT angiography and TTE was 97.53% and 79.62%, respectively. There was significant difference regarding to the diagnostic accuracy and the sensitivity between high-pitch DSCT angiography and TTE (χ2 = 23.561 and 28.013, P<0.05). The agreement on the image quality scoring of DSCT between the two observers was excellent (κ = 0.81), and the mean score of image quality was 4.1±0.7. The mean ED of DSCT was 0.29±0.08 mSv. Conclusions Prospective ECG-gated high-pitch 128-slice DSCT angiography with low radiation dose and high diagnostic accuracy has higher sensitivity compared to TTE in the detection of congenital extracardiac vascular anomalies in infants and children.


Clinical Radiology | 2012

The value of low-dose prospective ECG-gated dual-source CT angiography in the diagnosis of coarctation of the aorta in infants and children

Pei Nie; Xinpei Wang; Zhaoping Cheng; Yanhua Duan; Xiaopeng Ji; Jiuhong Chen; H. Zhang

AIM To investigate the value of prospective electrocardiogram (ECG)-gated dual-source computed tomography (DSCT) in the diagnosis of coarctation of the aorta (CoA). MATERIALS AND METHODS Seventeen patients clinically suspected of having CoA underwent prospective ECG-gated DSCT angiography and transthoracic echocardiography (TTE). Surgery was performed in all patients. The diagnostic accuracy of DSCT angiography and TTE was compared with the surgical findings as the reference standard. Image quality was evaluated using a five-point scale. Effective radiation dose was calculated from the dose-length product (DLP). RESULTS CoA was diagnosed in 17 patients by DSCT angiography and in 16 patients by TTE. A total of 46 separate cardiovascular abnormalities were confirmed by surgical findings. The diagnostic accuracy of DSCT angiography and TTE was 96.32% and 97.06%, respectively. There was no significant difference in the diagnostic accuracy between DSCT angiography and TTE (χ(2) = 0, p > 0.05). The mean score of image quality was 4.2 ± 0.8. The mean effective dose was 0.69 ± 0.09 mSv. CONCLUSION Prospective ECG-gated DSCT with a low radiation dose is a valuable technique in the diagnosis of CoA in infants and children.


PLOS ONE | 2014

Low-dose prospectively electrocardiogram-gated axial dual-source CT angiography in patients with pulsatile bilateral bidirectional Glenn Shunt: an alternative noninvasive method for postoperative morphological estimation.

Xiaopeng Ji; Bin Zhao; Zhaoping Cheng; Biao Si; Zhiheng Wang; Yanhua Duan; Pei Nie; Haiou Li; Shifeng Yang; Hui Jiao; Ximing Wang

Objective To explore the clinical value of low-dose prospectively electrocardiogram-gated axial dual-source CT angiography (low-dose PGA scanning, CTA) in patients with pulsatile bilateral bidirectional Glenn shunt (bBDG) as an alternative noninvasive method for postoperative morphological estimation. Methods Twenty patients with pulsatile bBDG (mean age 4.2±1.6 years) underwent both low-dose PGA scanning and conventional cardiac angiography (CCA) for the morphological changes. The morphological evaluation included the anatomy of superior vena cava (SVC) and pulmonary artery (PA), the anastomotic location, thrombosis, aorto-pulmonary collateral circulation, pulmonary arteriovenous malformations, etc. Objective and subjective image quality was assessed. Bland–Altman analysis and linear regression analyses were used to evaluate the correlation on measurements between CTA and CCA. Effective radiation dose of both modalities was calculated. Results The CT attenuation value of bilateral SVC and PA was higher than 300 HU. The average subjective image quality score was 4.05±0.69. The morphology of bilateral SVC and PA was displayed completely and intuitively by CTA images. There were 24 SVC above PA and 15 SVC beside PA. Thrombosis was found in 1 patient. Collateral vessels were detected in 13 patients. No pulmonary arteriovenous malformation was found in our study. A strong correlation (R2>0.8, P<0.001) was observed between the measurements on CTA images and on CCA images. Bland–Altman analysis demonstrated a systematic overestimation of the measurements by CTA (the mean value of bias>0).The mean effective dose of CTA and CCA was 0.50±0.17 mSv and 4.85±1.34 mSv respectively. Conclusion CT angiography with a low-dose PGA scanning is an accurate and reliable noninvasive examination in the assessment of morphological changes in patients with pulsatile bBDG.


PLOS ONE | 2013

Detection of airway anomalies in pediatric patients with cardiovascular anomalies with low dose prospective ECG-gated dual-source CT.

Hui Jiao; Zhuodong Xu; Lebin Wu; Zhaoping Cheng; Xiaopeng Ji; Hai Zhong; Chen Jin Meng

Objectives To assess the feasibility of low-dose prospective ECG-gated dual-source CT (DSCT) in detecting airway anomalies in pediatric patients with cardiovascular anomalies compared with flexible tracheobronchoscopy (FTB). Methods 33 pediatrics with respiratory symptoms who had been revealed cardiovascular anomalies by transthoracic echocardiography underwent FTB and contrast material–enhanced prospective ECG-triggering CT were enrolled. The study was approved by our institution review board and written informed consent was obtained from all patients’ guardian. DSCT examinations were performed to detect cardiovascular abnormalities using weight-adjusted low–dose protocol. Two radiologists independently performed CT image analysis. The FTB reports were reviewed by an experienced pulmonologist. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of DSCT in the detection of airway anomalies were assessed. The tracheobronchial stenoses revealed on FTB were graded. Effective radiation dose was calculated. Results Thirty cases were diagnosed with tracheobronchial narrowing and/or abnormality in 33 patients by FTB, while 3 patients had normal FTB findings. Twenty-eight cases were diagnosed with airway anomalies by CT, of which 27 were correct positive. 3 patients with normal findings at CT had findings of tracheobronchial narrowing due to tracheobronchomalacia at inspiration at FTB. Sensitivity and specificity of CT were 90.0% (95% CI: 72.3%, 97.4%) and 66.7% (95% CI: 12.5 %, 98.2 %), respectively. PPV and NPV were 96.4% (95% CI: 79.8 %, 99.8%) and 40.0% (95% CI: 7.3%, 83.0%), respectively. Overall accuracy of DSCT in detecting airway anomalies in pediatrics with cardiovascular anomalies was 87.9% (95% CI: 74.5%, 97.6%). In grading of tracheobronchial stenosis, images from CT correlated closely (r = 0.89) with those of FTB. Mean effective dose was 0.60±0.20 mSv. Conclusion In pediatric patients, ECG-triggered CT to evaluate congenital cardiovascular anomalies can also be used to diagnose and characterize fixed airway involvement in relation to the vascular structures.


Chinese Medical Journal | 2015

Comparison of Elastic Properties of Bilateral Carotid Arteries in Relation to Site of Acute Ischemic Stroke Using Velocity Vector Imaging

Jun-Li Hu; Xian Li; Ximing Wang; Zhaoping Cheng; Dong-Feng Chen; Shao-Chun Wang; Qing-Xia Kong

IntRoductIon Ischemic stroke accounts for 70% of all the cerebrovascular diseases. Severe stenosis and occlusions of extracranial and intracranial artery are all important risk factors causing ischemic stroke. Based on the widespread observation worldwide, intracranial atherosclerosis is the most common vascular lesions in Asians, Hispanics, and Africans.[1] Therefore, accurate and noninvasive methods for early diagnosis of stroke in individuals without significant stenosis of the extracranial carotid artery is of considerable clinical interest.


Chinese Medical Journal | 2015

Diagnostic Value of Prospective Electrocardiogram-triggered Dual-source Computed Tomography Angiography for Infants and Children with Interrupted Aortic Arch

Haiou Li; Ximing Wang; Pei Nie; Xiaopeng Ji; Zhaoping Cheng; Jiuhong Chen; Zhuodong Xu

Background: Accurate assessment of intra- as well as extra-cardiac malformations and radiation dosage concerns are especially crucial to infants and children with interrupted aortic arch (IAA). The purpose of this study is to investigate the value of prospective electrocardiogram (ECG)-triggered dual-source computed tomography (DSCT) angiography with low-dosage techniques in the diagnosis of IAA. Methods: Thirteen patients with suspected IAA underwent prospective ECG-triggered DSCT scan and transthoracic echocardiography (TTE). Surgery was performed on all the patients. A five-point scale was used to assess image quality. The diagnostic accuracy of DSCT angiography and TTE was compared with the surgical findings as the reference standard. A nonparametric Chi-square test was used for comparative analysis. P <0.05 was considered as a significant difference. The mean effective radiation dose (ED) was calculated. Results: Diagnostic DSCT images were obtained for all the patients. Thirteen IAA cases with 60 separate cardiovascular anomalies were confirmed by surgical findings. The diagnostic accuracy of TTE and DSCT for total cardiovascular malformations was 93.7% and 97.9% (P > 0.05), and that for extra-cardiac vascular malformations was 92.3% and 99.0% (P < 0.05), respectively. The mean score of image quality was 3.77 ± 0.83. The mean ED was 0.30 ± 0.04 mSv (range from 0.23 mSv to 0.39 mSv). Conclusions: In infants and children with IAA, prospective ECG-triggered DSCT with low radiation exposure and high diagnostic efficiency has higher accuracy compared to TTE in detection of extra-cardiac vascular anomalies.


European Radiology | 2010

Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience

Zhaoping Cheng; Ximing Wang; Yanhua Duan; Lebin Wu; Dawei Wu; Baoting Chao; Cheng Liu; Zhuodong Xu; Hongxin Li; Fei Liang; Jian Xu; Jiuhong Chen

Collaboration


Dive into the Zhaoping Cheng's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge