Alberto Lutman
SLAC National Accelerator Laboratory
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Alberto Lutman.
Nature Communications | 2014
C. Behrens; F.-J. Decker; Y. Ding; V. A. Dolgashev; J. Frisch; Zhirong Huang; P. Krejcik; H. Loos; Alberto Lutman; Timothy Maxwell; J. J. Turner; J. Wang; M.-H. Wang; J. Welch; J. Wu
X-ray free-electron lasers, with pulse durations ranging from a few to several hundred femtoseconds, are uniquely suited for studying atomic, molecular, chemical and biological systems. Characterizing the temporal profiles of these femtosecond X-ray pulses that vary from shot to shot is not only challenging but also important for data interpretation. Here we report the time-resolved measurements of X-ray free-electron lasers by using an X-band radiofrequency transverse deflector at the Linac Coherent Light Source. We demonstrate this method to be a simple, non-invasive technique with a large dynamic range for single-shot electron and X-ray temporal characterization. A resolution of less than 1 fs root mean square has been achieved for soft X-ray pulses. The lasing evolution along the undulator has been studied with the electron trapping being observed as the X-ray peak power approaches 100 GW.
Nature Communications | 2015
Agostino Marinelli; Daniel Ratner; Alberto Lutman; J. J. Turner; J. Welch; F.-J. Decker; H. Loos; C. Behrens; S. Gilevich; A. Miahnahri; Sharon Vetter; Timothy Maxwell; Y. Ding; Ryan Coffee; Soichi Wakatsuki; Zhirong Huang
The X-ray free-electron laser has opened a new era for photon science, improving the X-ray brightness by ten orders of magnitude over previously available sources. Similar to an optical laser, the spectral and temporal structure of the radiation pulses can be tailored to the specific needs of many experiments by accurately manipulating the lasing medium, that is, the electron beam. Here we report the generation of mJ-level two-colour hard X-ray pulses of few femtoseconds duration with an XFEL driven by twin electron bunches at the Linac Coherent Light Source. This performance represents an improvement of over an order of magnitude in peak power over state-of-the-art two-colour XFELs. The unprecedented intensity and temporal coherence of this new two-colour X-ray free-electron laser enable an entirely new set of scientific applications, ranging from X-ray pump/X-ray probe experiments to the imaging of complex biological samples with multiple wavelength anomalous dispersion.
Science Advances | 2016
Ken R. Ferguson; Maximilian Bucher; Tais Gorkhover; Sébastien Boutet; H. Fukuzawa; Jason E. Koglin; Yoshiaki Kumagai; Alberto Lutman; Agostino Marinelli; M. Messerschmidt; K. Nagaya; Jim Turner; K. Ueda; Garth J. Williams; P. H. Bucksbaum; Christoph Bostedt
Ultrafast x-ray heating of clusters leads to bond contraction in the solid-to-plasma transition. In condensed matter systems, strong optical excitations can induce phonon-driven processes that alter their mechanical properties. We report on a new phenomenon where a massive electronic excitation induces a collective change in the bond character that leads to transient lattice contraction. Single large van der Waals clusters were isochorically heated to a nanoplasma state with an intense 10-fs x-ray (pump) pulse. The structural evolution of the nanoplasma was probed with a second intense x-ray (probe) pulse, showing systematic contraction stemming from electron delocalization during the solid-to-plasma transition. These findings are relevant for any material in extreme conditions ranging from the time evolution of warm or hot dense matter to ultrafast imaging with intense x-ray pulses or, more generally, any situation that involves a condensed matter-to-plasma transition.
Nature Communications | 2016
Antonio Picón; C. S. Lehmann; Christoph Bostedt; Artem Rudenko; Agostino Marinelli; T. Osipov; Daniel Rolles; N. Berrah; C. Bomme; Maximilian Bucher; Gilles Doumy; Benjamin Erk; Ken R. Ferguson; Tais Gorkhover; Phay Ho; E. P. Kanter; B. Krässig; J. Krzywinski; Alberto Lutman; Anne Marie March; Dooshaye Moonshiram; D. Ray; L. Young; Stephen T. Pratt; S. H. Southworth
New capabilities at X-ray free-electron laser facilities allow the generation of two-colour femtosecond X-ray pulses, opening the possibility of performing ultrafast studies of X-ray-induced phenomena. Particularly, the experimental realization of hetero-site-specific X-ray-pump/X-ray-probe spectroscopy is of special interest, in which an X-ray pump pulse is absorbed at one site within a molecule and an X-ray probe pulse follows the X-ray-induced dynamics at another site within the same molecule. Here we show experimental evidence of a hetero-site pump-probe signal. By using two-colour 10-fs X-ray pulses, we are able to observe the femtosecond time dependence for the formation of F ions during the fragmentation of XeF2 molecules following X-ray absorption at the Xe site.
Optics Letters | 2012
Petri Karvinen; Simon Rutishauser; A. Mozzanica; D. Greiffenberg; Pavle Juranić; Andreas Menzel; Alberto Lutman; J. Krzywinski; David M. Fritz; Henrik T. Lemke; Marco Cammarata; Christian David
We present a spectrometer setup based on grating dispersion for hard x-ray free-electron lasers. This setup consists of a focusing spectrometer grating and a charge-integrating microstrip detector. Measurement results acquired at Linac Coherent Light Source are presented, demonstrating noninvasive monitoring of single-shot spectra with a resolution of 2.0×10(-4) ±0.3×10(-4) at photon energy of 6 keV with more than 95% transmission of the main beam.
Review of Scientific Instruments | 2016
Daniel Higley; Konstantin Hirsch; Georgi L. Dakovski; Emmanuelle Jal; Edwin Yuan; TianMin Liu; Alberto Lutman; James P. MacArthur; Elke Arenholz; Zhao Chen; G. Coslovich; Peter Denes; Patrick Granitzka; P. Hart; Matthias C. Hoffmann; John Joseph; Loic Le Guyader; Ankush Mitra; Stefan Moeller; Hendrik Ohldag; Matthew D. Seaberg; Padraic Shafer; J. Stöhr; A. Tsukamoto; H.-D. Nuhn; A. H. Reid; Hermann A. Dürr; W. F. Schlotter
X-ray magnetic circular dichroism spectroscopy using an X-ray free electron laser is demonstrated with spectra over the Fe L(3,2)-edges. The high brightness of the X-ray free electron laser combined with high accuracy detection of incident and transmitted X-rays enables ultrafast X-ray magnetic circular dichroism studies of unprecedented sensitivity. This new capability is applied to a study of all-optical magnetic switching dynamics of Fe and Gd magnetic sublattices in a GdFeCo thin film above its magnetization compensation temperature.
Applied Physics Letters | 2015
Y. Ding; C. Behrens; Ryan Coffee; F.-J. Decker; Paul Emma; C. Field; Wolfram Helml; Zhirong Huang; P. Krejcik; J. Krzywinski; Henrik Loos; Alberto Lutman; Agostino Marinelli; Timothy Maxwell; J. J. Turner
Generation of femtosecond to sub-femtosecond pulses is attracting much attention in X-ray free-electron laser user community. One method is to use a slotted, emittance-spoiling foil which was proposed before (P. Emma et al., Phys. Rev. Lett. 92, 074801 (2004)) and has been widely used at the Linac Coherent Light Source. Direct experimental characterization of the slotted-foil performance was previously unfeasible due to a lack of appropriate diagnostics. With a recently installed X-band radio-frequency transverse deflector, we are able to characterize the electron bunch spoiling effect and X-ray pulse when using the slotted foil. We show that few-femtosecond X-ray pulses are generated with flexible control of the single-pulse duration or double-pulse separation with comparison to the theoretical model.
Physical Review Letters | 2016
Agostino Marinelli; Ryan Coffee; Sharon Vetter; Philippe Hering; G. N. West; S. Gilevich; Alberto Lutman; S. Li; Timothy Maxwell; J. Galayda; Alan Fry; Z. Huang
In this Letter we report the experimental demonstration of a new temporal shaping technique for x-ray free-electron lasers (FELs). This technique is based on the use of a spectrally shaped infrared (IR) laser and allows optical control of the x-ray generation process. By accurately manipulating the spectral amplitude and phase of the IR laser, we can selectively modify the electron bunch longitudinal emittance thus controlling the duration of the resulting x-ray pulse down to the femtosecond time scale. Unlike other methods currently in use, optical shaping is directly applicable to the next generation of high-average power x-ray FELs such as the Linac Coherent Light Source-II or the European X-FEL, and it enables pulse shaping of FELs at the highest repetition rates. Furthermore, this laser-shaping technique paves the way for flexible tailoring of complex multicolor FEL pulse patterns required for nonlinear multidimensional x-ray spectroscopy as well as novel multicolor diffraction imaging schemes.
Optics Express | 2016
Thomas Kroll; Jan Kern; Markus Kubin; Daniel Ratner; Sheraz Gul; Franklin Fuller; Heike Löchel; J. Krzywinski; Alberto Lutman; Y. Ding; Georgi L. Dakovski; Stefan Moeller; J. J. Turner; Roberto Alonso-Mori; Dennis Nordlund; Jens Rehanek; Christian Weniger; Alexander Firsov; Maria Brzhezinskaya; Ruchira Chatterjee; Benedikt Lassalle-Kaiser; Raymond G. Sierra; Hartawan Laksmono; Ethan Hill; A. S. Borovik; Alexei Erko; A. Föhlisch; Rolf Mitzner; Vittal K. Yachandra; Junko Yano
X-ray free electron lasers (XFELs) enable unprecedented new ways to study the electronic structure and dynamics of transition metal systems. L-edge absorption spectroscopy is a powerful technique for such studies and the feasibility of this method at XFELs for solutions and solids has been demonstrated. However, the required x-ray bandwidth is an order of magnitude narrower than that of self-amplified spontaneous emission (SASE), and additional monochromatization is needed. Here we compare L-edge x-ray absorption spectroscopy (XAS) of a prototypical transition metal system based on monochromatizing the SASE radiation of the linac coherent light source (LCLS) with a new technique based on self-seeding of LCLS. We demonstrate how L-edge XAS can be performed using the self-seeding scheme without the need of an additional beam line monochromator. We show how the spectral shape and pulse energy depend on the undulator setup and how this affects the x-ray spectroscopy measurements.
Review of Scientific Instruments | 2016
Gregor Hartmann; Anton Lindahl; André Knie; Nick Hartmann; Alberto Lutman; James P. MacArthur; Ivan Shevchuk; Jens Buck; Andreas Galler; James M. Glownia; W. Helml; Z. Huang; N M Kabachnik; A. K. Kazansky; Jia Liu; Agostino Marinelli; T. Mazza; H.-D. Nuhn; Peter Walter; Jens Viefhaus; Michael Meyer; Stefan Moeller; Ryan Coffee; M. Ilchen
A non-destructive diagnostic method for the characterization of circularly polarized, ultraintense, short wavelength free-electron laser (FEL) light is presented. The recently installed Delta undulator at the LCLS (Linac Coherent Light Source) at SLAC National Accelerator Laboratory (USA) was used as showcase for this diagnostic scheme. By applying a combined two-color, multi-photon experiment with polarization control, the degree of circular polarization of the Delta undulator has been determined. Towards this goal, an oriented electronic state in the continuum was created by non-resonant ionization of the O2 1s core shell with circularly polarized FEL pulses at hν ≃ 700 eV. An also circularly polarized, highly intense UV laser pulse with hν ≃ 3.1 eV was temporally and spatially overlapped, causing the photoelectrons to redistribute into so-called sidebands that are energetically separated by the photon energy of the UV laser. By determining the circular dichroism of these redistributed electrons using angle resolving electron spectroscopy and modeling the results with the strong-field approximation, this scheme allows to unambiguously determine the absolute degree of circular polarization of any pulsed, ultraintense XUV or X-ray laser source.