Proceedings of SPIE | 2013

Multi-energy performance of a research prototype CT scanner with small-pixel counting detector

Steffen Kappler; Andre Henning; Bernhard Krauss; Friederike Schoeck; Karl Stierstorfer; Thomas Weidinger; Thomas Flohr

We have investigated the multi-energy performance of our most recent prototype CT scanner with CdTe-based counting detector. With its small pixel pitch of 225 μm this device is prepared for the high X-ray fluxes occurring in clinical CT. Each of these pixels is equipped with two adjustable counters. The ASIC architecture of the detector allows configuration of the counter thresholds in chess patterns, enabling data acquisition in up to four energy bins. We have studied the material separation capability of counting CT with respect to potential clinical applications. Therefore we have analyzed contrast and noise properties in material decomposed CT images using up to four base materials. We have studied contrast agents containing iodine, gadolinium, or gold, and the body-like materials calcium, fat, and water. We describe the mathematical framework used in this work and demonstrate the general multi-energy capability of counting CT with simulations and experimental data from our prototype scanner. To prove the clinical relevance of our studies we compare the results to those obtained with well-established dual-kVp techniques recorded at same patient dose and with identical image sharpness.


Proceedings of SPIE | 2014

Photon counting CT at elevated X-ray tube currents: contrast stability, image noise and multi-energy performance

Steffen Kappler; Andre Henning; Björn Kreisler; Friederike Schoeck; Karl Stierstorfer; Thomas Flohr

The energy-selectivity of photon counting detectors provides contrast enhancement and enables new material-identification techniques for clinical Computed Tomography (CT). Patient dose considerations and the resulting requirement of efficient X-ray detection suggest the use of CdTe or CdZnTe as detector material. The finite signal pulse duration of several nanoseconds present in those detectors requires strong reduction of the pixel size to achieve feasible count rates in the high-flux regime of modern CT scanners. Residual pulse pile-up effects in scans with high X-ray fluxes still can limit two key properties of the counting detector, namely count-rate linearity and spectral linearity. We have used our research prototype scanner with CdTe-based counting detector and 225μm small pixels to investigate these effects in CT imaging scenarios at elevated X-ray tube currents. We present measurements of CT images and provide a detailed analysis of contrast stability, image noise and multi-energy performance achieved with different phantom sizes at various X-ray tube settings.


Proceedings of SPIE | 2017

Ultra-High Spatial Resolution, Multi-Energy CT using Photon Counting Detector Technology.

Shuai Leng; R. Gutjahr; Andrea Ferrero; Steffen Kappler; Andre Henning; Ahmed F. Halaweish; Wei Zhou; Juan C. Montoya; Cynthia H. McCollough

Two ultra-high-resolution (UHR) imaging modes, each with two energy thresholds, were implemented on a research, whole-body photon-counting-detector (PCD) CT scanner, referred to as sharp and UHR, respectively. The UHR mode has a pixel size of 0.25 mm at iso-center for both energy thresholds, with a collimation of 32 × 0.25 mm. The sharp mode has a 0.25 mm pixel for the low-energy threshold and 0.5 mm for the high-energy threshold, with a collimation of 48 × 0.25 mm. Kidney stones with mixed mineral composition and lung nodules with different shapes were scanned using both modes, and with the standard imaging mode, referred to as macro mode (0.5 mm pixel and 32 × 0.5 mm collimation). Evaluation and comparison of the three modes focused on the ability to accurately delineate anatomic structures using the high-spatial resolution capability and the ability to quantify stone composition using the multi-energy capability. The low-energy threshold images of the sharp and UHR modes showed better shape and texture information due to the achieved higher spatial resolution, although noise was also higher. No noticeable benefit was shown in multi-energy analysis using UHR compared to standard resolution (macro mode) when standard doses were used. This was due to excessive noise in the higher resolution images. However, UHR scans at higher dose showed improvement in multi-energy analysis over macro mode with regular dose. To fully take advantage of the higher spatial resolution in multi-energy analysis, either increased radiation dose, or application of noise reduction techniques, is needed.


Proceedings of SPIE | 2016

A High-Resolution Imaging Technique using a Whole-body, Research Photon Counting Detector CT System

Shuai Leng; Zhicong Yu; Ahmed F. Halaweish; Steffen Kappler; K. Hahn; Andre Henning; Zhoubo Li; John I. Lane; David L. Levin; Steven M. Jorgensen; Erik L. Ritman; Cynthia H. McCollough

A high-resolution (HR) data collection mode has been introduced to a whole-body, research photon-counting-detector CT system installed in our laboratory. In this mode, 64 rows of 0.45 mm x 0.45 mm detector pixels were used, which corresponded to a pixel size of 0.25 mm x 0.25 mm at the iso-center. Spatial resolution of this HR mode was quantified by measuring the MTF from a scan of a 50 micron wire phantom. An anthropomorphic lung phantom, cadaveric swine lung, temporal bone and heart specimens were scanned using the HR mode, and image quality was subjectively assessed by two experienced radiologists. High spatial resolution of the HR mode was evidenced by the MTF measurement, with 15 lp/cm and 20 lp/cm at 10% and 2% modulation. Images from anthropomorphic phantom and cadaveric specimens showed clear delineation of small structures, such as lung vessels, lung nodules, temporal bone structures, and coronary arteries. Temporal bone images showed critical anatomy (i.e. stapes superstructure) that was clearly visible in the PCD system. These results demonstrated the potential application of this imaging mode in lung, temporal bone, and vascular imaging. Other clinical applications that require high spatial resolution, such as musculoskeletal imaging, may also benefit from this high resolution mode.


Journal of medical imaging | 2016

Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system

Shuai Leng; Zhicong Yu; Ahmed F. Halaweish; Steffen Kappler; K. Hahn; Andre Henning; Zhoubo Li; John I. Lane; David L. Levin; Steven M. Jorgensen; Erik L. Ritman; Cynthia H. McCollough

Abstract. An ultrahigh-resolution (UHR) data collection mode was enabled on a whole-body, research photon counting detector (PCD) computed tomography system. In this mode, 64 rows of 0.45  mm×0.45  mm detector pixels were used, which corresponded to a pixel size of 0.25  mm×0.25  mm at the isocenter. Spatial resolution and image noise were quantitatively assessed for the UHR PCD scan mode, as well as for a commercially available UHR scan mode that uses an energy-integrating detector (EID) and a set of comb filters to decrease the effective detector size. Images of an anthropomorphic lung phantom, cadaveric swine lung, swine heart specimen, and cadaveric human temporal bone were qualitatively assessed. Nearly equivalent spatial resolution was demonstrated by the modulation transfer function measurements: 15.3 and 20.3  lp/cm spatial frequencies were achieved at 10% and 2% modulation, respectively, for the PCD system and 14.2 and 18.6  lp/cm for the EID system. Noise was 29% lower in the PCD UHR images compared to the EID UHR images, representing a potential dose savings of 50% for equivalent image noise. PCD UHR images from the anthropomorphic phantom and cadaveric specimens showed clear delineation of small structures.


Journal of medical imaging | 2016

Noise performance of low-dose CT: Comparison between an energy integrating detector and a photon counting detector using a whole-body research photon counting CT scanner

Zhicong Yu; Shuai Leng; Steffen Kappler; K. Hahn; Zhoubo Li; Ahmed F. Halaweish; Andre Henning; Cynthia H. McCollough

Abstract. Photon counting detector (PCD)-based computed tomography (CT) is an emerging imaging technique. Compared to conventional energy integrating detector (EID)-based CT, PCD-CT is able to exclude electronic noise that may severely impair image quality at low photon counts. This work focused on comparing the noise performance at low doses between the PCD and EID subsystems of a whole-body research PCD-CT scanner, both qualitatively and quantitatively. An anthropomorphic thorax phantom was scanned, and images of the shoulder portion were reconstructed. The images were visually and quantitatively compared between the two subsystems in terms of streak artifacts, an indicator of the impact of electronic noise. Furthermore, a torso-shaped water phantom was scanned using a range of tube currents. The product of the noise and the square root of the tube current was calculated, normalized, and compared between the EID and PCD subsystems. Visual assessment of the thorax phantom showed that electronic noise had a noticeably stronger degrading impact in the EID images than in the PCD images. The quantitative results indicated that in low-dose situations, electronic noise had a noticeable impact (up to a 5.8% increase in magnitude relative to quantum noise) on the EID images, but negligible impact on the PCD images.


Proceedings of SPIE | 2017

Renal stone characterization using high resolution imaging mode on a photon counting detector CT system

Andrea Ferrero; R. Gutjahr; Andre Henning; Steffen Kappler; Ahmed F. Halaweish; Dilbar Abdurakhimova; Z. Peterson; Juan C. Montoya; Shuai Leng; Cynthia H. McCollough

In addition to the standard-resolution (SR) acquisition mode, a high-resolution (HR) mode is available on a research photon-counting-detector (PCD) whole-body CT system. In the HR mode each detector consists of a 2x2 array of 0.225 mm x 0.225 mm subpixel elements. This is in contrast to the SR mode that consists of a 4x4 array of the same subelements, and results in 0.25 mm isotropic resolution at iso-center for the HR mode. In this study, we quantified ex vivo the capabilities of the HR mode to characterize renal stones in terms of morphology and mineral composition. Forty pure stones - 10 uric acid (UA), 10 cystine (CYS), 10 calcium oxalate monohydrate (COM) and 10 apatite (APA) - and 14 mixed stones were placed in a 20 cm water phantom and scanned in HR mode, at radiation dose matched to that of routine dual-energy stone exams. Data from micro CT provided a reference for the quantification of morphology and mineral composition of the mixed stones. The area under the ROC curve was 1.0 for discriminating UA from CYS, 0.89 for CYS vs COM and 0.84 for COM vs APA. The root mean square error (RMSE) of the percent UA in mixed stones was 11.0% with a medium-sharp kernel and 15.6% with the sharpest kernel. The HR showed qualitatively accurate characterization of stone morphology relative to micro CT.


Proceedings of SPIE | 2017

Dual Energy CT Kidney Stone Differentiation in Photon Counting Computed Tomography

R. Gutjahr; Christoph Polster; Andre Henning; Steffen Kappler; Shuai Leng; Cynthia H. McCollough; Martin Sedlmair; Berthold Schmidt; Bernhard Krauss; Thomas Flohr

This study evaluates the capabilities of a whole-body photon counting CT system to differentiate between four common kidney stone materials, namely uric acid (UA), calcium oxalate monohydrate (COM), cystine (CYS), and apatite (APA) ex vivo. Two different x-ray spectra (120 kV and 140 kV) were applied and two acquisition modes were investigated. The macro-mode generates two energy threshold based image-volumes and two energy bin based image-volumes. In the chesspattern-mode four energy thresholds are applied. A virtual low energy image, as well as a virtual high energy image are derived from initial threshold-based images, while considering their statistically correlated nature. The energy bin based images of the macro-mode, as well as the virtual low and high energy image of the chesspattern-mode serve as input for our dual energy evaluation. The dual energy ratio of the individually segmented kidney stones were utilized to quantify the discriminability of the different materials. The dual energy ratios of the two acquisition modes showed high correlation for both applied spectra. Wilcoxon-rank sum tests and the evaluation of the area under the receiver operating characteristics curves suggest that the UA kidney stones are best differentiable from all other materials (AUC = 1.0), followed by CYS (AUC ≈ 0.9 compared against COM and APA). COM and APA, however, are hardly distinguishable (AUC between 0.63 and 0.76). The results hold true for the measurements of both spectra and both acquisition modes.


Proceedings of SPIE | 2016

Low-dose performance of a whole-body research photon-counting CT scanner

Zhicong Yu; Shuai Leng; Steffen Kappler; K. Hahn; Zhoubo Li; Ahmed F. Halaweish; Andre Henning; Erik L. Ritman; Cynthia H. McCollough

Photon-counting CT (PCCT) is an emerging technique that may bring new possibilities to clinical practice. Compared to conventional CT, PCCT is able to exclude electronic noise that may severely impair image quality at low photon counts. This work focused on assessing the low-dose performance of a whole-body research PCCT scanner consisting of two subsystems, one equipped with an energy-integrating detector, and the other with a photon-counting detector. Evaluation of the low-dose performance of the research PCCT scanner was achieved by comparing the noise performance of the two subsystems, with an emphasis on examining the impact of electronic noise on image quality in low-dose situations.


Archive | 2012

Medical apparatus installation, and method for controlling a medical apparatus

Andre Henning