Featured researches published by Andrew N. Primak.


Medical Physics | 2005

Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot

Thomas Flohr; Karl Stierstorfer; Stefan Ulzheimer; Herbert Dr. Bruder; Andrew N. Primak; Cynthia H. McCollough

We present a theoretical overview and a performance evaluation of a novel z-sampling technique for multidetector row CT (MDCT), relying on a periodic motion of the focal spot in the longitudinal direction (z-flying focal spot) to double the number of simultaneously acquired slices. The z-flying focal spot technique has been implemented in a recently introduced MDCT scanner. Using 32 x 0.6 mm collimation, this scanner acquires 64 overlapping 0.6 mm slices per rotation in its spiral (helical) mode of operation, with the goal of improved longitudinal resolution and reduction of spiral artifacts. The longitudinal sampling distance at isocenter is 0.3 mm. We discuss in detail the impact of the z-flying focal spot technique on image reconstruction. We present measurements of spiral slice sensitivity profiles (SSPs) and of longitudinal resolution, both in the isocenter and off-center. We evaluate the pitch dependence of the image noise measured in a centered 20 cm water phantom. To investigate spiral image quality we present images of an anthropomorphic thorax phantom and patient scans. The full width at half maximum (FWHM) of the spiral SSPs shows only minor variations as a function of the pitch, measured values differ by less than 0.15 mm from the nominal values 0.6, 0.75, 1, 1.5, and 2 mm. The measured FWHM of the smallest slice ranges between 0.66 and 0.68 mm at isocenter, except for pitch 0.55 (0.72 mm). In a centered z-resolution phantom, bar patterns up to 15 lp/cm can be visualized independent of the pitch, corresponding to 0.33 mm longitudinal resolution. 100 mm off-center, bar patterns up to 14 lp/cm are visible, corresponding to an object size of 0.36 mm that can be resolved in the z direction. Image noise for constant effective mAs is almost independent of the pitch. Measured values show a variation of less than 7% as a function of the pitch, which demonstrates correct utilization of the applied radiation dose at any pitch. The product of image noise and square root of the slice width (FWHM of the respective SSP) is the same constant for all slices except 0.6 mm. For the thinnest slice, relative image noise is increased by 17%. Spiral windmill-type artifacts are effectively suppressed with the z-flying focal spot technique, which has the potential to maintain a low artifact level up to pitch 1.5, in this way increasing the maximum volume coverage speed that can be clinically used.


Medical Physics | 2009

Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration

Andrew N. Primak; J Ramirez Giraldo; Xin Liu; Cynthia H. McCollough

The use of additional spectral filtration for dual-energy (DE) imaging using a dual-source CT (DSCT) system was investigated and its effect on the material-specific DE(ratio) was evaluated for several clinically relevant materials. The x-ray spectra, data acquisition, and reconstruction processes for a DSCT system (Siemens Definition) were simulated using information provided by the system manufacturer, resulting in virtual DE images. The factory-installed filtration for the 80 kV spectrum was left unchanged to avoid any further reductions in tube output, and only the filtration for the high-energy spectrum was modified. Only practical single-element filter materials within the atomic number range of 40 < or = Z < or = 83 were evaluated, with the aim of maximizing the separation between the two spectra, while maintaining similar noise levels for high- and low-energy images acquired at the same tube current. The differences between mean energies and the ratio of the 140 and 80 kV detector signals, each integrated below 80 keV, were evaluated. The simulations were performed for three attenuation scenarios: Head, body, and large body. The large body scenario was evaluated for the DE acquisition mode using the 100 and 140 kV spectra. The DE(ratio) for calcium hydroxyapatite (simulating bone or calcifications), iodine, and iron were determined for CT images simulated using the modified and factory-installed filtration. Several filter materials were found to perform well at proper thicknesses, with tin being a good practical choice. When image noise was matched between the low- and high-energy images, the spectral difference in mean absorbed energy using tin was increased from 25.7 to 42.7 keV (head), from 28.6 to 44.1 keV (body), and from 20.2 to 30.2 keV (large body). The overlap of the signal spectra for energies below 80 keV was reduced from 78% to 31% (head), from 93% to 27% (body), and from 106% to 79% (large body). The DE(ratio) for the body attenuation scenario increased from 1.45 to 1.91 (calcium), from 1.84 to 3.39 (iodine), and from 1.73 to 2.93 (iron) with the additional tin filtration compared to the factory filtration. This use of additional filtration for one of the x-ray tubes used in dual-source DECT dramatically increased the difference between material-specific DE ratios, e.g., from 0.39 to 1.48 for calcium and iodine or from 0.28 to 1.02 for calcium and iron. Because the ability to discriminate between different materials in DE imaging depends primarily on the differences in DE ratios, this increase is expected to improve the performance of any material-specific DECT imaging task. Furthermore, for the large patient size and in conjunction with a 100/140 kV acquisition, the use of additional filtration decreased noise in the low-energy images and increased contrast in the DE image relative to that obtained with 80/140 kV and no additional filtration.


Radiographics | 2008

CT Dosimetry : Comparison of Measurement Techniques and Devices

John A. Bauhs; Thomas J. Vrieze; Andrew N. Primak; Michael R. Bruesewitz; Cynthia H. McCollough

In x-ray computed tomography (CT), the most common parameter used to estimate and minimize patient dose is the CT dose index (CTDI). The CTDI is a volume-averaged measure that is used in situations where the table is incremented in conjunction with the tube rotation. Variants of the CTDI correct for averaging across the field of view and for adjacent beam overlaps or gaps. CTDI is usually measured with a pencil-shaped ionization chamber, although methods have been developed that use alternative detectors, including an optically stimulated luminescence probe and a solid-state real-time dosimeter. Because the CTDI represents an averaged dose to a homogeneous cylindrical phantom, the measurements are only an approximation of the patient dose. Furthermore, dose from interventional or perfusion CT, in which the table remains stationary between multiple scans, is best evaluated with point dose measurements made with small detectors. CTDI and point dose values are nearly the same for measurement of surface dose from spiral CT. However, for measurement of surface dose from perfusion CT, the dose is overestimated by a factor of two or more with CTDI values in comparison with point dose values. Both CTDI and point dose measurement are valuable for evaluating CT scanner output and estimating patient dose.


Medical Physics | 2009

Quantitative imaging of element composition and mass fraction using dual-energy CT: three-material decomposition.

Xin Liu; Andrew N. Primak; Cynthia H. McCollough

In principle, dual-energy CT can only accurately decompose a mixture into two materials. To decompose a mixture into three constitute materials using dual-energy CT measurements, a third criteria must be provided to solve for three unknowns with only two spectral measurements. One solution is to assume that the sum of the volumes of three constituent materials is equivalent to the volume of the mixture (i.e., volume conservation), but this is not always true. A more generalized solution is to use the principle of mass conservation, which assumes that the sum of the masses of the three constituent materials is equivalent to the mass of the mixture. In this article, a mass-conservation based, three-material decomposition dual-energy CT algorithm is described and experimental validation of the accuracy of the technique presented. The results demonstrate that the proposed method can accurately measure elemental concentrations under low noise imaging conditions. Clinically, this may be applied to measure the mass fraction of any chemical element in a three-material mixture of solutions without the requirement of volume conservation.


American Journal of Roentgenology | 2012

Contrast-to-Noise Ratio and Low-Contrast Object Resolution on Full- and Low-Dose MDCT: SAFIRE Versus Filtered Back Projection in a Low-Contrast Object Phantom and in the Liver

Mark E. Baker; Frank Dong; Andrew N. Primak; Nancy A. Obuchowski; David M. Einstein; Namita Gandhi; Brian R. Herts; Andrei S. Purysko; Erick M. Remer; Neil Vachani

OBJECTIVE The purpose of this article is to evaluate the effect of sinogram-affirmed iterative reconstruction (SAFIRE) on contrast-to-noise ratio (CNR) compared with filtered back projection (FBP) and to determine whether SAFIRE improves low-contrast object detection or conspicuity in a low-contrast object phantom and in the liver on full- and low-dose examinations. SUBJECTS AND METHODS A low-contrast object phantom was scanned at 100%, 70%, 50%, and 30% dose using a single-source made of a dual-source MDCT scanner, with the raw data reconstructed with SAFIRE and FBP. Unenhanced liver CT scans in 22 patients were performed using a dual-source MDCT. The raw data from both tubes (100% dose) were reconstructed using FBP, and data from one tube (50% dose) were reconstructed using both FBP and SAFIRE. CNR was measured in the phantom and in the liver. Noise, contrast, and CNR were compared using paired Student t tests. Six readers assessed sphere detection and conspicuity in the phantom and liver-inferior vena cava conspicuity in the patient data. The phantom and patient data were assessed using multiple-variable logistic regression. RESULTS The phantom at 70% and 50% doses with SAFIRE had decreased noise and increased CNR compared with the 100% dose with FBP. In the liver, the mean CNR improvement at 50% dose with SAFIRE compared with FBP was 31.4% and 88% at 100% and 50% doses, respectively (p < 0.001). Sphere object detection and conspicuity improved with SAFIRE (p < 0.001). However, smaller spheres were obscured on both FBP and SAFIRE images at lower doses. Liver-vessel conspicuity improved with SAFIRE over 50%-dose FBP in 67.4% of cases (p < 0.001), and versus 100%-dose FBP, improved in 38.6% of cases (p = 0.085). As a predictor for detection, CNR alone had a discriminatory ability (c-index, 0.970) similar to that of the model that analyzed dose, lesion size, attenuation difference, and reconstruction technique (c-index, 0.978). CONCLUSION Lower dose scans reconstructed with SAFIRE have a higher CNR. The ability of SAFIRE to improve low-contrast object detection and conspicuity depends on the radiation dose level. At low radiation doses, low-contrast objects are invisible, regardless of reconstruction technique.


Medical Physics | 2009

Image quality optimization and evaluation of linearly mixed images in dual-source, dual-energy CT

Lifeng Yu; Andrew N. Primak; Xin Liu; Cynthia H. McCollough

In dual-source dual-energy CT, the images reconstructed from the low- and high-energy scans (typically at 80 and 140 kV, respectively) can be mixed together to provide a single set of nonmaterial-specific images for the purpose of routine diagnostic interpretation. Different from the material-specific information that may be obtained from the dual-energy scan data, the mixed images are created with the purpose of providing the interpreting physician a single set of images that have an appearance similar to that in single-energy images acquired at the same total radiation dose. In this work, the authors used a phantom study to evaluate the image quality of linearly mixed images in comparison to single-energy CT images, assuming the same total radiation dose and taking into account the effect of patient size and the dose partitioning between the low-and high-energy scans. The authors first developed a method to optimize the quality of the linearly mixed images such that the single-energy image quality was compared to the best-case image quality of the dual-energy mixed images. Compared to 80 kV single-energy images for the same radiation dose, the iodine CNR in dual-energy mixed images was worse for smaller phantom sizes. However, similar noise and similar or improved iodine CNR relative to 120 kV images could be achieved for dual-energy mixed images using the same total radiation dose over a wide range of patient sizes (up to 45 cm lateral thorax dimension). Thus, for adult CT practices, which primarily use 120 kV scanning, the use of dual-energy CT for the purpose of material-specific imaging can also produce a set of non-material-specific images for routine diagnostic interpretation that are of similar or improved quality relative to single-energy 120 kV scans.


American Journal of Roentgenology | 2008

Dual-Energy CT Iodine-Subtraction Virtual Unenhanced Technique to Detect Urinary Stones in an Iodine-Filled Collecting System: A Phantom Study

Naoki Takahashi; Robert P. Hartman; Terri J. Vrtiska; Akira Kawashima; Andrew N. Primak; Oleksandr P. Dzyubak; Jayawant N. Mandrekar; Joel G. Fletcher; Cynthia H. McCollough

OBJECTIVE The objective of our study was to evaluate the feasibility of virtual unenhanced images reconstructed from a dual-energy CT scan to depict urinary stones in an iodine solution in a phantom study. MATERIALS AND METHODS Twenty urinary stones of different sizes (1.4-4.2 mm in short-axis diameter) were placed in plastic containers. The containers were consecutively filled with different concentrations of iodine solution (21, 43, 64, 85, and 107 mg/dL; CT attenuation value range, 510-2,310 H at 120 kVp). Dual-energy CT was repeated with 80-140 and 100-140 kVp pairs, two collimation-slice thickness combinations, and the presence or absence of a 4-cm-thick oil gel around the phantom. The iodine-subtraction virtual unenhanced images were reconstructed using commercial software. The images were evaluated by three radiologists in consensus for the visibility of the stones and the presence of residual nonsubtracted iodine. Stone visibility rates were compared between the 80-140 and 100-140 kVp pairs and the five different iodine concentrations. RESULTS Stone visibility rates with the 80-140 kVp pair were 99%, 93%, 96%, 94%, and 3% and those with the 100-140 kVp pair were 98%, 95%, 99%, 94%, and 99% for an iodine concentration of 21, 43, 64, 85, and 107 mg/dL, respectively. The poor visibility rate with 80-140 kVp and 107 mg/dL iodine concentration was due to the failure of iodine subtraction. CONCLUSION Dual-energy CT iodine-subtraction virtual unenhanced technique is capable of depicting urinary stones in iodine solutions of a diverse range of concentrations in a phantom study.


American Journal of Roentgenology | 2010

Dual-Source Dual-Energy CT With Additional Tin Filtration: Dose and Image Quality Evaluation in Phantoms and In Vivo

Andrew N. Primak; Juan Carlos Ramírez Giraldo; Christian Eusemann; Bernhard Schmidt; Birgit Kantor; Joel G. Fletcher; Cynthia H. McCollough

OBJECTIVE The objective of this study was to investigate the effect on radiation dose and image quality of the use of additional spectral filtration for dual-energy CT using dual-source CT (DSCT). MATERIALS AND METHODS A commercial DSCT scanner was modified by adding tin filtration to the high-kV tube, and radiation output and noise were measured in water phantoms. Dose values for equivalent image noise were compared between the dual-energy mode with and without tin filtration and the single-energy mode. To evaluate dual-energy CT material discrimination, the material-specific dual-energy ratio for calcium and that for iodine were determined using images of anthropomorphic phantoms. Data were additionally acquired from imaging a 38-kg pig and an 87-kg pig, and the noise of the linearly mixed images and virtual noncontrast images was compared between dual-energy modes. Finally, abdominal dual-energy CT images of two patients of similar sizes undergoing clinically indicated CT were compared. RESULTS Adding tin filtration to the high-kV tube improved the dual-energy contrast between iodine and calcium as much as 290%. Data from our animal study showed that tin filtration had no effect on noise in the dual-energy CT mixed images but decreased noise by as much as 30% in the virtual noncontrast images. Virtual noncontrast images of patients acquired using 100 and 140 kV with added tin filtration had improved image quality relative to those generated using 80 and 140 kV without tin filtration. CONCLUSION Tin filtration of the high-kV tube of a DSCT scanner increases the ability of dual-energy CT to discriminate between calcium and iodine without increasing dose relative to single-energy CT. Furthermore, the use of 100- and 140-kV tube potentials allows improved dual-energy CT imaging of large patients.


Radiology | 2008

Radiation dose to the fetus for pregnant patients undergoing multidetector CT imaging: Monte carlo simulations estimating fetal dose for a range of gestational age and patient size1

Erin Angel; Clinton V. Wellnitz; Mitchell M. Goodsitt; Nazanin Yaghmai; J DeMarco; Christopher H. Cagnon; James Sayre; Dianna D. Cody; Donna M. Stevens; Andrew N. Primak; Cynthia H. McCollough; Michael F. McNitt-Gray

PURPOSE To use Monte Carlo simulations of a current-technology multidetector computed tomographic (CT) scanner to investigate fetal radiation dose resulting from an abdominal and pelvic examination for a range of actual patient anatomies that include variation in gestational age and maternal size. MATERIALS AND METHODS Institutional review board approval was obtained for this HIPAA-compliant retrospective study. Twenty-four models of maternal and fetal anatomy were created from image data from pregnant patients who had previously undergone clinically indicated CT examination. Gestational age ranged from less than 5 weeks to 36 weeks. Simulated helical scans of the abdominal and pelvic region were performed, and a normalized dose (in milligrays per 100 mAs) was calculated for each fetus. Stepwise multiple linear regression was performed to analyze the correlation of dose with gestational age and anatomic measurements of maternal size and fetal location. Results were compared with several existing fetal dose estimation methods. RESULTS Normalized fetal dose estimates from the Monte Carlo simulations ranged from 7.3 to 14.3 mGy/100 mAs, with an average of 10.8 mGy/100 mAs. Previous methods yielded values of 10-14 mGy/100 mAs. The correlation between gestational age and fetal dose was not significant (P = .543). Normalized fetal dose decreased linearly with increasing patient perimeter (R(2) = 0.681, P < .001), and a two-factor model with patient perimeter and fetal depth demonstrated a strong correlation with fetal dose (R(2) = 0.799, P < .002). CONCLUSION A method for the estimation of fetal dose from models of actual patient anatomy that represented a range of gestational age and patient size was developed. Fetal dose correlated with maternal perimeter and varied more than previously recognized. This correlation improves when maternal size and fetal depth are combined.


Radiology | 2010

Detectability of urinary stones on virtual nonenhanced images generated at pyelographic-phase dual-energy CT.

Naoki Takahashi; Terri J. Vrtiska; Akira Kawashima; Robert P. Hartman; Andrew N. Primak; Joel G. Fletcher; Cynthia H. McCollough

PURPOSE To evaluate the detectability of urinary stones on virtual nonenhanced images generated at pyelographic-phase dual-energy computed tomography (CT). MATERIALS AND METHODS This retrospective HIPAA-compliant study was institutional review board approved. All included patients had previously consented to the use of their medical records for research. Sixty-two patients (38 men, 24 women; age range, 35-91 years) had undergone CT urography, which consisted of nonenhanced and pyelographic-phase dual-energy CT performed by using a dual-source scanner. Commercial software was used to create virtual nonenhanced images by suppressing the iodine signal from the pyelographic-phase dual-energy CT scans. Two radiologists, in consensus, evaluated the virtual nonenhanced images for the presence of stones. Sensitivity for detecting stones was calculated on a per-stone basis. Sensitivity, specificity, and accuracy were also calculated on a per-renal unit (defined as the intrarenal collecting system and ureter of one kidney) basis. The true nonenhanced scan was considered the reference standard. A jackknife method was used because any patient may have multiple stones. RESULTS Of 62 patients with 122 renal units, 21 patients with 25 renal units had a total of 43 stones (maximal transverse diameter range, 1-24 mm; median, 3 mm). The overall sensitivity for detecting stones was 63% (27 of 43 stones) per stone. Sensitivities were 29% (four of 14 stones) for 1-2-mm stones, 64% (nine of 14 stones) for 3-4-mm stones, 83% (five of six stones) for 5-6-mm stones, and 100% (nine of nine stones) for 7-mm or larger (7, 7, 7, 8, 8, 9, 11, 15, and 24 mm) stones. All three ureteral stones (3, 4, and 8 mm) were correctly identified. The sensitivity, specificity, and accuracy for detecting stones on a per-renal unit basis were 65% (17 of 26 renal units), 92% (88 of 96 renal units), and 86% (105 of 122 renal units), respectively. CONCLUSION Virtual nonenhanced images generated at pyelographic-phase dual-energy CT enabled the detection of urinary stones with moderate accuracy. The detection of small (1-2-mm) stones was limited.

Collaboration


Dive into the Andrew N. Primak's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Xin Liu

Missouri University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge