Angela L. Zachman
Vanderbilt University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Angela L. Zachman.
Biomaterials | 2011
Andrea E. Hafeman; Katarz Yna J. Zienkiewicz; Angela L. Zachman; Hak-Joon Sung; Lillian B. Nanney; Jeffrey M. Davidson; Scott A. Guelcher
Characterization of the degradation mechanism of polymeric scaffolds and delivery systems for regenerative medicine is essential to assess their clinical applicability. Key performance criteria include induction of a minimal, transient inflammatory response and controlled degradation to soluble non-cytotoxic breakdown products that are cleared from the body by physiological processes. Scaffolds fabricated from biodegradable poly(ester urethane)s (PEURs) undergo controlled degradation to non-cytotoxic breakdown products and support the ingrowth of new tissue in preclinical models of tissue regeneration. While previous studies have shown that PEUR scaffolds prepared from lysine-derived polyisocyanates degrade faster under in vivo compared to in vitro conditions, the degradation mechanism is not well understood. In this study, we have shown that PEUR scaffolds prepared from lysine triisocyanate (LTI) or a trimer of hexamethylene diisocyanate (HDIt) undergo hydrolytic, esterolytic, and oxidative degradation. Hydrolysis of ester bonds to yield α-hydroxy acids is the dominant mechanism in buffer, and esterolytic media modestly increase the degradation rate. While HDIt scaffolds show a modest (<20%) increase in degradation rate in oxidative medium, LTI scaffolds degrade six times faster in oxidative medium. Furthermore, the in vitro rate of degradation of LTI scaffolds in oxidative medium approximates the in vivo rate in rat excisional wounds, and histological sections show macrophages expressing myeloperoxidase at the material surface. While recent preclinical studies have underscored the potential of injectable PEUR scaffolds and delivery systems for tissue regeneration, this promising class of biomaterials has a limited regulatory history. Elucidation of the macrophage-mediated oxidative mechanism by which LTI scaffolds degrade in vivo provides key insights into the ultimate fate of these materials when injected into the body.
Biomacromolecules | 2011
Shann S. Yu; Rachel L. Koblin; Angela L. Zachman; Daniel S. Perrien; Lucas H. Hofmeister; Todd D. Giorgio; Hak-Joon Sung
Chronic inflammation-mediated oxidative stress is a common mechanism of implant rejection and failure. Therefore, polymer scaffolds that can degrade slowly in response to this environment may provide a viable platform for implant site-specific, sustained release of immunomodulatory agents over a long time period. In this work, proline oligomers of varying lengths (P(n)) were synthesized and exposed to oxidative environments, and their accelerated degradation under oxidative conditions was verified via high performance liquid chromatography and gel permeation chromatography. Next, diblock copolymers of poly(ethylene glycol) (PEG) and poly(ε-caprolactone) (PCL) were carboxylated to form 100 kDa terpolymers of 4%PEG-86%PCL-10%cPCL (cPCL = poly(carboxyl-ε-caprolactone); i% indicates molar ratio). The polymers were then cross-linked with biaminated PEG-P(n)-PEG chains, where P(n) indicates the length of the proline oligomer flanked by PEG chains. Salt-leaching of the polymeric matrices created scaffolds of macroporous and microporous architecture, as observed by scanning electron microscopy. The degradation of scaffolds was accelerated under oxidative conditions, as evidenced by mass loss and differential scanning calorimetry measurements. Immortalized murine bone-marrow-derived macrophages were then seeded on the scaffolds and activated through the addition of γ-interferon and lipopolysaccharide throughout the 9-day study period. This treatment promoted the release of H(2)O(2) by the macrophages and the degradation of proline-containing scaffolds compared to the control scaffolds. The accelerated degradation was evidenced by increased scaffold porosity, as visualized through scanning electron microscopy and X-ray microtomography imaging. The current study provides insight into the development of scaffolds that respond to oxidative environments through gradual degradation for the controlled release of therapeutics targeted to diseases that feature chronic inflammation and oxidative stress.
Journal of Materials Chemistry B | 2014
Sue Hyun Lee; Timothy C. Boire; Jung Bok Lee; Mukesh K. Gupta; Angela L. Zachman; Rutwik Rath; Hak-Joon Sung
A reactive oxygen species (ROS)-degradable scaffold is fabricated by crosslinking biocompatible, hydrolytically-degradable poly(ε-caprolactone) (PCL) with a ROS-degradable oligoproline peptide, KP7K. The ROS-mediated degradability triggers favorable host responses of the scaffold including improved cell infiltration and angiogenesis in vivo, indicating its unique advantages for tissue engineering applications.
Acta Biomaterialia | 2015
Timothy C. Boire; Mukesh K. Gupta; Angela L. Zachman; Sue Hyun Lee; Daniel A. Balikov; Kwangho Kim; Leon M. Bellan; Hak-Joon Sung
UNLABELLED Thermo-responsive shape memory polymers (SMPs) can be programmed to fit into small-bore incisions and recover their functional shape upon deployment in the body. This property is of significant interest for developing the next generation of minimally-invasive medical devices. To be used in such applications, SMPs should exhibit adequate mechanical strengths that minimize adverse compliance mismatch-induced host responses (e.g. thrombosis, hyperplasia), be biodegradable, and demonstrate switch-like shape recovery near body temperature with favorable biocompatibility. Combinatorial approaches are essential in optimizing SMP material properties for a particular application. In this study, a new class of thermo-responsive SMPs with pendant, photocrosslinkable allyl groups, x%poly(ε-caprolactone)-co-y%(α-allyl carboxylate ε-caprolactone) (x%PCL-y%ACPCL), are created in a robust, facile manner with readily tunable material properties. Thermomechanical and shape memory properties can be drastically altered through subtle changes in allyl composition. Molecular weight and gel content can also be altered in this combinatorial format to fine-tune material properties. Materials exhibit highly elastic, switch-like shape recovery near 37°C. Endothelial compatibility is comparable to tissue culture polystyrene (TCPS) and 100%PCL in vitro and vascular compatibility is demonstrated in vivo in a murine model of hindlimb ischemia, indicating promising suitability for vascular applications. STATEMENT OF SIGNIFICANCE With the ongoing thrust to make surgeries minimally-invasive, it is prudent to develop new biomaterials that are highly compatible and effective in this workflow. Thermo-responsive shape memory polymers (SMPs) have great potential for minimally-invasive applications because SMP medical devices (e.g. stents, grafts) can fit into small-bore minimally-invasive surgical devices and recover their functional shape when deployed in the body. To realize their potential, it is imperative to devise combinatorial approaches that enable optimization of mechanical, SM, and cellular responses for a particular application. In this study, a new class of thermo-responsive SMPs is created in a robust, facile manner with readily tunable material properties. Materials exhibit excellent, switch-like shape recovery near body temperature and promising biocompatibility for minimally-invasive vascular applications.
Acta Biomaterialia | 2012
Spencer W. Crowder; Mukesh K. Gupta; Lucas H. Hofmeister; Angela L. Zachman; Hak-Joon Sung
Polymer properties can be tailored by copolymerizing subunits with specific physico-chemical characteristics. Vascular stent materials require biocompatibility, mechanical strength, and prevention of restenosis. Here we copolymerized poly(ε-caprolactone) (PCL), poly(ethylene glycol) (PEG), and carboxyl-PCL (cPCL) at varying molar ratios and characterized the resulting material properties. We then performed a short-term evaluation of these polymers for their applicability as potential coronary stent coating materials with two primary human coronary artery cell types: smooth muscle cells (HCASMC) and endothelial cells (HCAEC). Changes in proliferation and phenotype were dependent upon intracellular reactive oxygen species (ROS) levels, and 4%PEG-96%PCL-0%cPCL was identified as the most appropriate coating material for this application. After 3days on this substrate HCASMC maintained a healthy contractile phenotype and HCAEC exhibited a physiologically relevant proliferation rate and a balanced redox state. Other test substrates promoted a pathological, synthetic phenotype of HCASMC and/or hyperproliferation of HCAEC. Phenotypic changes of HCASMC appeared to be modulated by the Youngs modulus and surface charge of the test substrates, indicating a structure-function relationship that can be exploited for intricate control over vascular cell functions. These data indicate that tailored copolymer properties can direct vascular cell behavior and provide insights for further development of biologically instructive stent coating materials.
Acta Biomaterialia | 2013
Angela L. Zachman; Jonathan M. Page; Gayathri Prabhakar; Scott A. Guelcher; Hak-Joon Sung
Circulating monocytes undergo spontaneous apoptosis when there is no activation stimulus, which is critical to population control for proper host response to implants. As activation and apoptosis of monocytes/macrophages are regulated by cell-cell and cell-matrix interactions, their regulatory mechanism was investigated in this study using polyethylene glycol (PEG)-containing polyurethane films in which PEG-rich and polyester-rich domains were phase separated. Human blood monocyte-derived macrophages (HBMs) preferentially adhered to PEG domains (cell-matrix interaction) due to the low molecular weight (600 g mol⁻¹), resulting in increased HBM density (cell-cell interaction). As both cell-cell and cell-matrix interactions were promoted, HBM apoptosis increased, while their activation as measured by phagocytosis, intracellular reactive oxygen species (ROS) level and matrix metalloproteinase-9 production decreased compared to PEG-free films. When cell seeding density and cell-adhesive gelatin coating on silicone films were controlled, a cooperative role of cell-matrix (adhesion) and cell-cell (density) interactions in inducing HBM apoptosis was observed. Expression of the macrophage adhesion molecule CD11b caused apoptosis in this context, which was mediated by tissue necrosis factor-α signaling but down-regulated by the ROS inhibitor diphenylene iodonium and the anti-inflammatory peptide Ac-SDKP, suggesting a new concept for the design of biomaterials that allows for cell adhesion without excessive inflammatory activation.
Journal of Cellular Biochemistry | 2014
Xintong Wang; Angela L. Zachman; Nicholas A. Haglund; Simon Maltais; Hak-Joon Sung
Remarkable achievements have been made in the clinical application of mechanical circulatory support and cardiac transplantation for patients with end‐stage heart failure. Despite the successes, complications associated with these therapies continue to drive cardiac regenerative research utilizing stem cell based therapies. Multiple stem cell lineages hold clinical promise for cardiac regeneration—mostly through cellular differentiation, cellular fusion, and paracrine signaling mechanisms. Bone marrow‐derived endothelial progenitor cells are among the most intriguing and controversial cell types currently being investigated. Formidable barriers exist, however, in finding the ideal cardiac regenerative stem cell, such as identifying specific lineage markers, optimizing in vitro cellular expansion and improving methods of stem cell delivery. Hybrid approaches of cardiac regeneration using stem cell therapies in conjunction with immunomodulation after cardiac transplantation or with mechanical circulatory support produce cutting edge stem cell technologies. This review summarizes the current knowledge and therapeutic applications of stem cells in patients with end‐stage heart failure, including stem cell therapy after implantation of mechanical circulatory support and cardiac transplantation. J. Cell. Biochem. 115: 1217–1224, 2014.
Acta Biomaterialia | 2016
Timothy C. Boire; Mukesh K. Gupta; Angela L. Zachman; Sue Hyun Lee; Daniel A. Balikov; Kwangho Kim; Leon M. Bellan; Hak-Joon Sung
UNLABELLED Thermo-responsive shape memory polymers (SMPs) can be programmed to fit into small-bore incisions and recover their functional shape upon deployment in the body. This property is of significant interest for developing the next generation of minimally-invasive medical devices. To be used in such applications, SMPs should exhibit adequate mechanical strengths that minimize adverse compliance mismatch-induced host responses (e.g. thrombosis, hyperplasia), be biodegradable, and demonstrate switch-like shape recovery near body temperature with favorable biocompatibility. Combinatorial approaches are essential in optimizing SMP material properties for a particular application. In this study, a new class of thermo-responsive SMPs with pendant, photocrosslinkable allyl groups, x%poly(ε-caprolactone)-co-y%(α-allyl carboxylate ε-caprolactone) (x%PCL-y%ACPCL), are created in a robust, facile manner with readily tunable material properties. Thermomechanical and shape memory properties can be drastically altered through subtle changes in allyl composition. Molecular weight and gel content can also be altered in this combinatorial format to fine-tune material properties. Materials exhibit highly elastic, switch-like shape recovery near 37 °C. Endothelial compatibility is comparable to tissue culture polystyrene (TCPS) and 100%PCL in vitro and vascular compatibility is demonstrated in vivo in a murine model of hindlimb ischemia, indicating promising suitability for vascular applications. STATEMENT OF SIGNIFICANCE With the ongoing thrust to make surgeries minimally-invasive, it is prudent to develop new biomaterials that are highly compatible and effective in this workflow. Thermo-responsive shape memory polymers (SMPs) have great potential for minimally-invasive applications because SMP medical devices (e.g. stents, grafts) can fit into small-bore minimally-invasive surgical devices and recover their functional shape when deployed in the body. To realize their potential, it is imperative to devise combinatorial approaches that enable optimization of mechanical, SM, and cellular responses for a particular application. In this study, a new class of thermo-responsive SMPs is created in a robust, facile manner with readily tunable material properties. Materials exhibit excellent, switch-like shape recovery near body temperature and promising biocompatibility for minimally-invasive vascular applications.
Nanomedicine: Nanotechnology, Biology and Medicine | 2014
Angela L. Zachman; Lucas H. Hofmeister; Lino Costa; Timothy C. Boire; Yu-Shik Hwang; William H. Hofmeister; Hak-Joon Sung
UNLABELLED The major goal of this study was to create easy-to-use, reusable substrates capable of storing any peptides or bioactive molecules for a desired period of time until cells uptake them without the need for bioactive molecule or peptide-specific techniques. Nanopore arrays of uniform size and distribution were machined into fused silica substrates using femtosecond laser ablation and loaded with peptides by simple adsorption. The nanopore substrates were validated by examining the effect of N-acetyl-seryl-aspartyl-lysyl-proline (Ac-SDKP) loaded nanopores on macrophage phagocytosis and intracellular production of reactive oxygen species (ROS) with and without the pro-inflammatory lipopolysaccharide (LPS). Our results demonstrated that nanopores were generated in a uniform array fashion. Ac-SDKP peptides were stably stored in nanopores and internalized by macrophages. Significant reductions in ROS production and phagocytosis in macrophages were observed over control substrates, even in combination with LPS stimulation, indicating that loading Ac-SDKP peptides in pores significantly improved the anti-inflammatory effects. FROM THE CLINICAL EDITOR This team of scientists intended to create easy-to-use, reusable substrates for storing peptides or bioactive molecules for a desired period of time before cellular uptake occurs, and without the need for bioactive molecule or peptide-specific techniques. They demonstrate the successful generation of nanopores in a uniform array that stably stores Ac-SDKP peptides in the nanopores. When peptides were internalized by macrophages, significant reductions in ROS production and phagocytosis were observed, indicating improved anti-inflammatory effects.
International Journal of Cardiology | 2014
Xintong Wang; Angela L. Zachman; Young Wook Chun; Fang-Wen Shen; Yu-Shik Hwang; Hak-Joon Sung
BACKGROUND Biodegradable polymers have been applied as bulk or coating materials for coronary artery stents. The degradation of polymers, however, could induce endothelial dysfunction and aggravate neointimal formation. Here we use polymeric microparticles to simulate and demonstrate the effects of degraded stent materials on phagocytic activity, cell death and dysfunction of macrophages and endothelial cells. METHODS Microparticles made of low molecular weight polyesters were incubated with human macrophages and coronary artery endothelial cells (ECs). Microparticle-induced phagocytosis, cytotoxicity, apoptosis, cytokine release and surface marker expression were determined by immunostaining or ELISA. Elastase expression was analyzed by ELISA and the elastase-mediated polymer degradation was assessed by mass spectrometry. RESULTS We demonstrated that poly(D,L-lactic acid) (PLLA) and polycaprolactone (PCL) microparticles induced cytotoxicity in macrophages and ECs, partially through cell apoptosis. The particle treatment alleviated EC phagocytosis, as opposed to macrophages, but enhanced the expression of vascular cell adhesion molecule (VCAM)-1 along with decreased nitric oxide production, indicating that ECs were activated and lost their capacity to maintain homeostasis. The activation of both cell types induced the release of elastase or elastase-like protease, which further accelerated polymer degradation. CONCLUSIONS This study revealed that low molecule weight PLLA and PCL microparticles increased cytotoxicity and dysregulated endothelial cell function, which in turn enhanced elastase release and polymer degradation. These indicate that polymer or polymer-coated stents impose a risk of endothelial dysfunction after deployment which can potentially lead to delayed endothelialization, neointimal hyperplasia and late thrombosis.