Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Azhang Hamlekhan is active.

Publication


Featured researches published by Azhang Hamlekhan.


PLOS ONE | 2014

Fabrication of Anti-Aging TiO2 Nanotubes on Biomedical Ti Alloys

Azhang Hamlekhan; Arman Butt; Sweetu Patel; Dmitry Royhman; Christos G. Takoudis; Cortino Sukotjo; Judy Chia Chun Yuan; Gregory Jursich; Mathew T. Mathew; William Hendrickson; Amarjit S. Virdi; Tolou Shokuhfar

The primary objective of this study was to fabricate a TiO2 nanotubular surface, which could maintain hydrophilicity over time (resist aging). In order to achieve non-aging hydrophilic surfaces, anodization and annealing conditions were optimized. This is the first study to show that anodization and annealing condition affect the stability of surface hydrophilicity. Our results indicate that maintenance of hydrophilicity of the obtained TiO2 nanotubes was affected by anodization voltage and annealing temperature. Annealing sharply decreased the water contact angle (WCA) of the as-synthesized TiO2 nanotubular surface, which was correlated to improved hydrophilicity. TiO2 nanotubular surfaces are transformed to hydrophilic surfaces after annealing, regardless of annealing and anodization conditions; however, WCA measurements during aging demonstrate that surface hydrophilicity of non-anodized and 20 V anodized samples decreased after only 11 days of aging, while the 60 V anodized samples maintained their hydrophilicity over the same time period. The nanotubes obtained by 60 V anodization followed by 600 °C annealing maintained their hydrophilicity significantly longer than nanotubes which were obtained by 60 V anodization followed by 300 °C annealing.


International Journal of Nanomedicine | 2014

Biophysical evaluation of cells on nanotubular surfaces: the effects of atomic ordering and chemistry.

Tolou Shokuhfar; Azhang Hamlekhan; Jen Yung Chang; Chang K young Choi; Cortino Sukotjo; Craig R. Friedrich

After the implantation of a biomaterial in the body, the first interaction occurs between the cells in contact with the biomaterial surface. Therefore, evaluating the cell–substrate interface is crucial for designing a successful implant. In this study, the interaction of MC3T3 osteoblasts was studied on commercially pure and alloy (Ti6Al4V) Ti surfaces treated with amorphous and crystalline titanium dioxide nanotubes. The results indicated that the presence of nanotubes increased the density of osteoblast cells in comparison to bare surfaces (no nanotubes). More importantly, our finding shows that the chemistry of the substrate affects the cell density rather than the morphology of the cells. A novel approach based on the focused ion beam technique was used to investigate the biophysical cell–substrate interaction. The analysis revealed that portions of the cells migrated inside the crystalline nanotubes. This observation was correlated with the super hydrophilic properties of the crystalline nanotubes.


Biomaterials | 2014

Cerium oxide nanoparticles attenuate monocrotaline induced right ventricular hypertrophy following pulmonary arterial hypertension

Madhukar B. Kolli; Nandini D.P.K. Manne; Radhakrishna Para; Siva K. Nalabotu; Geeta Nandyala; Tolou Shokuhfar; Kun He; Azhang Hamlekhan; Jane Y. Ma; Paulette S. Wehner; Lucy Dornon; Ravikumar Arvapalli; Kevin M. Rice; Eric R. Blough

Cerium oxide (CeO2) nanoparticles have been posited to exhibit potent anti-oxidant activity which may allow for the use of these materials in biomedical applications. Herein, we investigate whether CeO2 nanoparticle administration can diminish right ventricular (RV) hypertrophy following four weeks of monocrotaline (MCT)-induced pulmonary arterial hypertension (PAH). Male Sprague Dawley rats were randomly divided into three groups: control, MCT only (60 mg/kg), or MCT + CeO2 nanoparticle treatment (60 mg/kg; 0.1 mg/kg). Compared to the control group, the RV weight to body weight ratio was 45% and 22% higher in the MCT and MCT + CeO2 groups, respectively (p < 0.05). Doppler echocardiography demonstrated that CeO2 nanoparticle treatment attenuated monocrotaline-induced changes in pulmonary flow and RV wall thickness. Paralleling these changes in cardiac function, CeO2 nanoparticle treatment also diminished MCT-induced increases in right ventricular (RV) cardiomyocyte cross sectional area, β-myosin heavy chain, fibronectin expression, protein nitrosylation, protein carbonylation and cardiac superoxide levels. These changes with treatment were accompanied by a decrease in the ratio of Bax/Bcl2, diminished caspase-3 activation and reduction in serum inflammatory markers. Taken together, these data suggest that CeO2 nanoparticle administration may attenuate the hypertrophic response of the heart following PAH.


Materials Science and Engineering: C | 2015

Synthesis and characterization of nanocrystalline forsterite coated poly(l-lactide-co-β-malic acid) scaffolds for bone tissue engineering applications

Masoud Mozafari; M. Gholipourmalekabadi; N.P.S. Chauhan; N. Jalali; S. Asgari; J.C. Caicedoa; Azhang Hamlekhan; A.M. Urbanska

In this research, after synthesizing poly(L-lactide-co-β-malic acid) (PLMA) copolymer, hybrid particles of ice and nanocrystalline forsterite (NF) as coating carriers were used to prepare NF-coated PLMA scaffolds. The porous NF-coated scaffolds were directly fabricated by a combined technique using porogen leaching and freeze-drying methods. The obtained results indicate that the scaffolds were structurally porous with NF particles on their surfaces. When compared to the uncoated scaffolds, the NF coating improved both mechanical properties as well as enhanced bioactivity of the scaffolds. In addition, in vitro biological response of the rat bone marrow stromal cells indicated that NF significantly increased the biocompatibility of NF-coated scaffolds compared with PLMA.


Journal of Physics D | 2015

Fabrication of drug eluting implants: study of drug release mechanism from titanium dioxide nanotubes

Azhang Hamlekhan; Suman Sinha-Ray; Christos G. Takoudis; Mathew T. Mathew; Cortino Sukotjo; Alexander L. Yarin; Tolou Shokuhfar

Formation of titanium dioxide nanotubes (TNTs) on a titanium surface holds great potential for promoting desirable cellular response. However, prolongation of drug release from these nano-reservoirs remains to be a challenge. In our previous work TNTs were successfully loaded with a drug. In this study the effect of TNTs dimensions on prolongation of drug release is quantified aiming at the introduction of a simple novel technique which overcomes complications of previously introduced methods. Different groups of TNTs with different lengths and diameters are fabricated. Samples are loaded with a model drug and rate of drug release over time is monitored. The relation of the drug release rate to the TNT dimensions (diameter, length, aspect ratio and volume) is established. The results show that an increase in any of these parameters increases the duration of the release process. However, the strongest parameter affecting the drug release is the aspect ratio. In fact, TNTs with higher aspect ratios release drug slower. It is revealed that drug release from TNT is a diffusion-limited process. Assuming that diffusion of drug in (Phosphate-Buffered Saline) PBS follows onedimensional Fick’s law, the theoretical predictions for drug release profile is compatible with our experimental data for release from a single TNT.


Materials Science and Engineering: C | 2016

Thermally oxidized titania nanotubes enhance the corrosion resistance of Ti6Al4V

John Grotberg; Azhang Hamlekhan; Arman Butt; Sweetu Patel; Dmitry Royhman; Tolou Shokuhfar; Cortino Sukotjo; Christos G. Takoudis; Mathew T. Mathew

The negative impact of in vivo corrosion of metallic biomedical implants remains a complex problem in the medical field. We aimed to determine the effects of electrochemical anodization (60V, 2h) and thermal oxidation (600°C) on the corrosive behavior of Ti-6Al-4V, with serum proteins, at physiological temperature. Anodization produced a mixture of anatase and amorphous TiO2 nanopores and nanotubes, while the annealing process yielded an anatase/rutile mixture of TiO2 nanopores and nanotubes. The surface area was analyzed by the Brunauer-Emmett-Teller method and was estimated to be 3 orders of magnitude higher than that of polished control samples. Corrosion resistance was evaluated on the parameters of open circuit potential, corrosion potential, corrosion current density, passivation current density, polarization resistance and equivalent circuit modeling. Samples both anodized and thermally oxidized exhibited shifts of open circuit potential and corrosion potential in the noble direction, indicating a more stable nanoporous/nanotube layer, as well as lower corrosion current densities and passivation current densities than the smooth control. They also showed increased polarization resistance and diffusion limited charge transfer within the bulk oxide layer. The treatment groups studied can be ordered from greatest corrosion resistance to least as Anodized+Thermally Oxidized > Anodized > Smooth > Thermally Oxidized for the conditions investigated. This study concludes that anodized surface has a potential to prevent long term implant failure due to corrosion in a complex in-vivo environment.


Journal of Oral Implantology | 2014

A Novel Investigation of the Formation of TiO₂ Nanotubes on Thermally Formed Oxide of Ti-6Al-4V

Arman Butt; Azhang Hamlekhan; Sweetu Patel; Dmitry Royhman; Cortino Sukotjo; Mathew T. Mathew; Tolou Shokuhfar; Christos G. Takoudis

Traditionally, titanium oxide (TiO2) nanotubes (TNTs) are anodized on Ti-6Al-4V alloy (Ti-V) surfaces with native TiO2 (amorphous TiO2); subsequent heat treatment of anodized surfaces has been observed to enhance cellular response. As-is bulk Ti-V, however, is often subjected to heat treatment, such as thermal oxidation (TO), to improve its mechanical properties. Thermal oxidation treatment of Ti-V at temperatures greater than 200°C and 400°C initiates the formation of anatase and rutile TiO2, respectively, which can affect TNT formation. This study aims at understanding the TNT formation mechanism on Ti-V surfaces with TO-formed TiO2 compared with that on as-is Ti-V surfaces with native oxide. Thermal oxidation-formed TiO2 can affect TNT formation and surface wettability because TO-formed TiO2 is expected to be part of the TNT structure. Surface characterization was carried out with field emission scanning electron microscopy, energy dispersive x-ray spectroscopy, water contact angle measurements, and white light interferometry. The TNTs were formed on control and 300°C and 600°C TO-treated Ti-V samples, and significant differences in TNT lengths and surface morphology were observed. No difference in elemental composition was found. Thermal oxidation and TO/anodization treatments produced hydrophilic surfaces, while hydrophobic behavior was observed over time (aging) for all samples. Reduced hydrophobic behavior was observed for TO/anodized samples when compared with control, control/anodized, and TO-treated samples. A method for improved surface wettability and TNT morphology is therefore discussed for possible applications in effective osseointegration of dental and orthopedic implants.


RSC Advances | 2017

Transparent TiO2 nanotubes on zirconia for biomedical applications

Sweetu Patel; Natalie Baker; Isabella da Silva Vieira Marques; Azhang Hamlekhan; Mathew T. Mathew; Christos G. Takoudis; Craig R. Friedrich; Cortino Sukotjo; Tolou Shokuhfar

Tissue discoloration in dental implant patients with thin gingival tissue is one of the many causes of dental implants’ revision surgery. Therefore, the purpose of this study is to address this issue by developing a surface that has a “tooth like bright colored” appearance while at the same time enhancing the bone implant integration. A biomimetic surface is fabricated by forming transparent TiO2 nanotubes on zirconia (TTNZ) that can enhance the proliferation and attachment of human mesenchymal stem cells (hMSCs) as compared to roughened ZrO2. This surface treatment was aimed to resolve tissue discoloration and aesthetic appearance problems for dental implant patients, while also enhancing biocompatibility. TiO2 nanotubes (TNTs) were formed using an electrochemical anodization technique in an electrolyte comprised of NH4F, ethylene glycol and water. The presence of TNTs on the ZrO2 substrate was detected by field emission scanning electron microscopy (FESEM). Optical images of longer anodized (20 and 30 min) samples show the white colored appearance characteristic of ZrO2 and FESEM confirmed the presence of TNTs on anodized samples. Surface characteristics of all samples were analyzed using water contact angle analysis, Fourier-transform infrared spectroscopy, white light interferometry and FESEM. Quantitative and qualitative biocompatibility analysis of treated and non-treated ZrO2 surfaces were obtained by performing FESEM, 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-2H-tetrazolium bromide (MTT) assay and fluorescence microscopy. FESEM revealed well-elongated and well-spread cell morphology on the nanotubular surface as compared to roughened ZrO2. Additionally, MTT assay showed a significantly high cell proliferation for anodized Ti–ZrO2 surface as compared to roughened ZrO2 after 7 days of incubation.


International Journal of Oral & Maxillofacial Implants | 2017

Efficiency of Nanotube Surface-Treated Dental Implants Loaded with Doxycycline on Growth Reduction of Porphyromonas gingivalis

Cimara Fortes Ferreira; Jegdish Babu; Azhang Hamlekhan; Sweetu Patel; Tolou Shokuhfar

PURPOSE The prevalence of peri-implant infection in patients with dental implants has been shown to range from 28% to 56%. A nanotube-modified implant surface can deliver antibiotics locally and suppress periodontal pathogenic bacterial growth. The aim of this study was to evaluate the deliverability of antibiotics via a nanotube-modified implant. MATERIALS AND METHODS Dental implants with a nanotube surface were fabricated and loaded with doxycycline. Afterward, each dental implant with a nanotube surface was placed into 2-mL tubes, removed from solution, and placed in a fresh solution daily for 28 days. Experimental samples from 1, 2, 4, 16, 24, and 28 days were used for this evaluation. The concentration of doxycycline was measured using spectrophotometric analysis at 273-nm absorbance. The antibacterial effect of doxycycline was evaluated by supplementing Porphyromonas gingivalis (P gingivalis) growth media with the solution collected from the dental implants at the aforementioned time intervals for a period of 48 hours under anaerobic conditions. A bacterial viability assay was used to evaluate P gingivalis growth at 550-nm absorbance. RESULTS Doxycycline concentration varied from 0.33 to 1.22 μg/mL from day 1 to day 28, respectively. A bacterial viability assay showed the highest P gingivalis growth at day 1 (2 nm) and the lowest at day 4 (0.17 nm), with a gradual reduction from day 1 to day 4 of approximately 87.5%. The subsequent growth pattern was maintained and slightly increased from baseline in approximately 48.3% from day 1 to day 24. The final P gingivalis growth measured at day 28 was 29.4% less than the baseline growth. CONCLUSION P gingivalis growth was suppressed in media supplemented with solution collected from dental implants with a nanotube surface loaded with doxycycline during a 28-day time interval.


143rd Annual Meeting and Exhibition, TMS 2014 | 2014

Optimization of Anodization and Annealing Condition Enhances TiO 2 Nanotubular Surface Hydrophilicity

Azhang Hamlekhan; Arman Butt; Sweetu Patel; Dmitry Royhman; Christos G. Takoudis; Cortino Sukotjo; Mathew T. Mathew; Tolou Shokuhfar

In this study anodization and annealing condition are optimized to fabricate nanotubular surface which is able to maintain its hydrophilicity over time — anti-aging surface. Our results indicate that anodization voltage and annealing temperature affect surface ability to maintain its hydrophilicity. Water contact angle measurements show hydrophilicty is sharply decreased after annealing regardless of annealing and anodization conditions. Non-anodized and 20 V anodized samples lose their hydrophilicity after 11 days of aging in air, while 60 V anodized samples are able to maintain their hydrophilicity after this period.

Collaboration


Dive into the Azhang Hamlekhan's collaboration.

Top Co-Authors

Avatar

Tolou Shokuhfar

University of Illinois at Chicago

View shared research outputs
Top Co-Authors

Avatar

Cortino Sukotjo

University of Illinois at Chicago

View shared research outputs
Top Co-Authors

Avatar

Sweetu Patel

University of Illinois at Chicago

View shared research outputs
Top Co-Authors

Avatar

Christos G. Takoudis

University of Illinois at Chicago

View shared research outputs
Top Co-Authors

Avatar

Mathew T. Mathew

University of Illinois at Chicago

View shared research outputs
Top Co-Authors

Avatar

Arman Butt

University of Illinois at Chicago

View shared research outputs
Top Co-Authors

Avatar

Dmitry Royhman

Rush University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Amarjit S. Virdi

Rush University Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Craig R. Friedrich

Michigan Technological University

View shared research outputs
Researchain Logo
Decentralizing Knowledge