Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Behnoosh Tavakoli is active.

Publication


Featured researches published by Behnoosh Tavakoli.


Optics Express | 2008

Three dimensional visualization by photon counting computational Integral Imaging

Behnoosh Tavakoli; Bahram Javidi; Edward A. Watson

In this paper, we present three dimensional (3D) object reconstruction using photon-counted elemental images acquired by a passive 3D Integral Imaging (II) system. The maximum likelihood (ML) estimator is derived to reconstruct the irradiance of the 3D scene pixels and the reliability of the estimator is described by confidence intervals. For applications in photon scarce environments, our proposed technique provides 3D reconstruction for better visualization as well as significant reduction in the computational burden and required bandwidth for transmission of integral images. The performance of the reconstruction is illustrated qualitatively and compared quantitatively with Peak to Signal to Noise Ratio (PSNR) criterion.


Radiology | 2013

Breast Cancer: Assessing Response to Neoadjuvant Chemotherapy by Using US-guided Near-Infrared Tomography

Quing Zhu; Patricia DeFusco; Andrew Ricci; Edward Cronin; Poornima Hegde; Mark Kane; Behnoosh Tavakoli; Yan Xu; Jesse Hart; Susan Tannenbaum

PURPOSE To assess initial breast tumor hemoglobin (Hb) content before the initiation of neoadjuvant chemotherapy, monitor the Hb changes at the end of each treatment cycle, and correlate these findings with tumor pathologic response. MATERIALS AND METHODS The HIPAA-compliant study protocol was approved by the institutional review boards of both institutions. Written informed consent was obtained from all patients. Patients who were eligible for neoadjuvant chemotherapy were recruited between December 2007 and May 2011, and their tumor Hb content was assessed by using a near-infrared imager coupled with an ultrasonography (US) system. Thirty-two women (mean age, 48 years; range, 32-82 years) were imaged before treatment, at the end of every treatment cycle, and before definitive surgery. The patients were graded in terms of their final pathologic response on the basis of the Miller-Payne system as nonresponders and partial responders (grades 1-3) and near-complete and complete responders (grades 4 and 5). Tumor vascularity was assessed from total Hb (tHb), oxygenated Hb (oxyHb), and deoxygenated Hb (deoxyHb) concentrations. Tumor vascularity changes during treatment were assessed from percentage tHb normalized to the pretreatment level. A two-sample two-sided t test was used to calculate the P value and to evaluate statistical significance between groups. Bonferroni-Holm correction was applied to obtain the corrected P value for multiple comparisons. RESULTS There were 20 Miller-Payne grade 1-3 tumors and 14 grade 4 or 5 tumors. Mean maximum pretreatment tHb, oxyHb, and deoxyHb levels were significantly higher in grade 4 and 5 tumors than in grade 1-3 tumors (P = .005, P = .008, and P = .017, respectively). The mean percentage tHb changes were significantly higher in grade 4 or 5 tumors than in grade 1-3 tumors at the end of treatment cycles 1-3 (P = .009 and corrected P = .009, P = .002 and corrected P = .004, and P < .001 and corrected P < .001, respectively). DISCUSSION These findings indicate that initial tumor Hb content is a strong predictor of final pathologic response. Additionally, the tHb changes during early treatment cycles can further predict final pathologic response.


Optics Express | 2007

Performance of 3D integral imaging with position uncertainty

Behnoosh Tavakoli; Mehdi Daneshpanah; Bahram Javidi; Edward A. Watson

We present the theoretical and simulation results on the analysis of Synthetic Aperture Integral Imaging (SAII) technique and its sensitivity to pickup position uncertainty. SAII is a passive three dimensional imaging technique based on multiple image acquisitions with different perspective of the scene under incoherent or natural illumination. In practical SAII applications, there is always an uncertainty associated with the position at which each sensor captures the elemental image. We present a theoretical analysis that quantifies image degradation in terms of Mean Square Error (MSE) metric. Simulation results are also presented to identify the parameters affecting the reconstruction degradation and to confirm the analysis. We show that in SAII with a given uncertainty in the sensor locations, the high spatial frequency content of the 3D reconstructed images are most degraded. We also show an inverse relationship between the reconstruction distance and degradation metric. To the best of our knowledge, this is the first time that the effects of sensor position uncertainty on 3D computational reconstruction in synthetic aperture integral imaging systems have been quantitatively analyzed.


Journal of Biomedical Optics | 2011

Target detection and quantification using a hybrid hand-held diffuse optical tomography and photoacoustic tomography system.

Patrick D. Kumavor; Chen Xu; Andres Aguirre; John Gamelin; Yasaman Ardeshirpour; Behnoosh Tavakoli; Saeid Zanganeh; Umar Alqasemi; Yi Yang; Quing Zhu

We present a photoacoustic tomography-guided diffuse optical tomography approach using a hand-held probe for detection and characterization of deeply-seated targets embedded in a turbid medium. Diffuse optical tomography guided by coregistered ultrasound, MRI, and x ray has demonstrated a great clinical potential to overcome lesion location uncertainty and to improve light quantification accuracy. However, due to the different contrast mechanisms, some lesions may not be detectable by a nonoptical modality but yet have high optical contrast. Photoacoustic tomography utilizes a short-pulsed laser beam to diffusively penetrate into tissue. Upon absorption of the light by the target, photoacoustic waves are generated and used to reconstruct, at ultrasound resolution, the optical absorption distribution that reveals optical contrast. However, the robustness of optical property quantification of targets by photoacoustic tomography is complicated because of the wide range of ultrasound transducer sensitivity, the orientation and shape of the targets relative to the ultrasound array, and the uniformity of the laser beam. We show in this paper that the relative optical absorption map provided by photoacoustic tomography can potentially guide the diffuse optical tomography to accurately reconstruct target absorption maps.


Journal of Biophotonics | 2013

Co-registered pulse-echo/photoacoustic transvaginal probe for real time imaging of ovarian tissue.

Patrick D. Kumavor; Umar Alqasemi; Behnoosh Tavakoli; Hai Li; Yi Yang; Xiaoguang Sun; Edward Warych; Quing Zhu

We present the design and construction of a prototype imaging probe capable of co-registered pulse-echo ultrasound and photoacoustic (optoacoustic) imaging in real time. The probe consists of 36 fibers of 200 micron core diameter each that are distributed around a commercial transvaginal ultrasound transducer, and housed in a protective shield. Its performance was demonstrated by two sets of experiments. The first set involved imaging of blood flowing through a tube mimicking a blood vessel, the second set involved imaging of human ovaries ex vivo. The results suggest that the system along with the probe has great potential for imaging and characterizing of ovarian tissue in vivo.


Journal of Biomedical Optics | 2013

Two-step reconstruction method using global optimization and conjugate gradient for ultrasound-guided diffuse optical tomography

Behnoosh Tavakoli; Quing Zhu

Abstract. Ultrasound-guided diffuse optical tomography (DOT) is a promising method for characterizing malignant and benign lesions in the female breast. We introduce a new two-step algorithm for DOT inversion in which the optical parameters are estimated with the global optimization method, genetic algorithm. The estimation result is applied as an initial guess to the conjugate gradient (CG) optimization method to obtain the absorption and scattering distributions simultaneously. Simulations and phantom experiments have shown that the maximum absorption and reduced scattering coefficients are reconstructed with less than 10% and 25% errors, respectively. This is in contrast with the CG method alone, which generates about 20% error for the absorption coefficient and does not accurately recover the scattering distribution. A new measure of scattering contrast has been introduced to characterize benign and malignant breast lesions. The results of 16 clinical cases reconstructed with the two-step method demonstrates that, on average, the absorption coefficient and scattering contrast of malignant lesions are about 1.8 and 3.32 times higher than the benign cases, respectively.


Journal of Biomedical Optics | 2011

Depth-correction algorithm that improves optical quantification of large breast lesions imaged by diffuse optical tomography

Behnoosh Tavakoli; Quing Zhu

Optical quantification of large lesions imaged with diffuse optical tomography in reflection geometry is depth dependence due to the exponential decay of photon density waves. We introduce a depth-correction method that incorporates the target depth information provided by coregistered ultrasound. It is based on balancing the weight matrix, using the maximum singular values of the target layers in depth without changing the forward model. The performance of the method is evaluated using phantom targets and 10 clinical cases of larger malignant and benign lesions. The results for the homogenous targets demonstrate that the location error of the reconstructed maximum absorption coefficient is reduced to the range of the reconstruction mesh size for phantom targets. Furthermore, the uniformity of absorption distribution inside the lesions improve about two times and the median of the absorption increases from 60 to 85% of its maximum compared to no depth correction. In addition, nonhomogenous phantoms are characterized more accurately. Clinical examples show a similar trend as the phantom results and demonstrate the utility of the correction method for improving lesion quantification.


Journal of Biomedical Optics | 2010

Effect of ultrasound transducer face reflectivity on the light fluence inside a turbid medium in photoacoustic imaging

Behnoosh Tavakoli; Patrick D. Kumavor; Andres Aguirre; Quing Zhu

Many endoscopic, intravascular, and transvaginal applications require light to be delivered through optical fibers in a reflection mode. For photoacoustic imaging in reflection geometry, the front-face reflectivity of the ultrasound transducer face imposes a boundary condition that affects the light fluence and its distribution inside a turbid medium. Understanding and characterizing this boundary condition is critical for maximizing tissue illumination and therefore the signal-to-noise ratio of the photoacoustic signal. We systematically analyze the light fluence under three typical commercial transducer faces having reflection coefficients of 1.4, 18, and 28%, and compare the results to a transducer face with 60% coefficient at the laser wavelength of 750 nm. Monte Carlo simulations and experimental results show that light fluence and distribution obtained inside a turbid medium with the use of the 60% reflection coefficient transducer face has a significant improvement over the others, especially at shallower depths.


Proceedings of SPIE, the International Society for Optical Engineering | 2007

Analysis of synthetic aperture integral imaging

Behnoosh Tavakoli; Mehdi Daneshpanah; Bahram Javidi; Edward A. Watson

We present the simulation results on the analysis of Synthetic Aperture Integral Imaging (SAII) technique and its sensitivity to pickup position uncertainty. SAII is a passive three dimensional imaging technique based on multiple image acquisitions with different perspective of the scene under incoherent or natural illumination. In practical SAII applications, there is always an uncertainty associated with the position at which each sensor captures the elemental image. We present simulation results of image degradation in terms of Mean Square Error (MSE) metric. We also show an inverse relationship between the reconstruction distance and degradation metric.


Proceedings of SPIE | 2013

Ovarian tissue characterization using bulk optical properties

Behnoosh Tavakoli; Yan Xu; Quing Zhu

Ovarian cancer, the deadliest of all gynecologic cancers, is not often found in its early stages due to few symptoms and no reliable screening test. Optical imaging has a great potential to improve the ovarian cancer detection and diagnosis. In this study we have characterized the bulk optical properties of 26 ex-vivo human ovaries using a Diffuse Optical Tomography system. The quantitative values indicated that, in the postmenopausal group, malignant ovaries showed significantly lower scattering coefficient than normal ones. The scattering parameter is largely related to the collagen content that has shown a strong correlation with the cancer development.

Collaboration


Dive into the Behnoosh Tavakoli's collaboration.

Top Co-Authors

Avatar

Quing Zhu

University of Connecticut

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Yan Xu

University of Connecticut

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Mark Kane

University of Connecticut

View shared research outputs
Top Co-Authors

Avatar

Poornima Hegde

University of Connecticut Health Center

View shared research outputs
Top Co-Authors

Avatar

Susan Tannenbaum

University of Connecticut Health Center

View shared research outputs
Top Co-Authors

Avatar

Andres Aguirre

University of Connecticut

View shared research outputs
Top Co-Authors

Avatar

Bahram Javidi

University of Connecticut

View shared research outputs
Researchain Logo
Decentralizing Knowledge