Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Birgitta Norlindh is active.

Publication


Featured researches published by Birgitta Norlindh.


PLOS ONE | 2013

Strontium-doped calcium phosphate and hydroxyapatite granules promote different inflammatory and bone remodelling responses in normal and ovariectomised rats.

Carina Cardemil; Ibrahim Elgali; Wei Xia; Lena Emanuelsson; Birgitta Norlindh; Omar Omar; Peter Thomsen

The healing of bone defects may be hindered by systemic conditions such as osteoporosis. Calcium phosphates, with or without ion substitutions, may provide advantages for bone augmentation. However, the mechanism of bone formation with these materials is unclear. The aim of this study was to evaluate the healing process in bone defects implanted with hydroxyapatite (HA) or strontium-doped calcium phosphate (SCP) granules, in non-ovariectomised (non-OVX) and ovariectomised (OVX) rats. After 0 (baseline), six and 28d, bone samples were harvested for gene expression analysis, histology and histomorphometry. Tumour necrosis factor-α (TNF-α), at six days, was higher in the HA, in non-OVX and OVX, whereas interleukin-6 (IL-6), at six and 28d, was higher in SCP, but only in non-OVX. Both materials produced a similar expression of the receptor activator of nuclear factor kappa-B ligand (RANKL). Higher expression of osteoclastic markers, calcitonin receptor (CR) and cathepsin K (CatK), were detected in the HA group, irrespective of non-OVX or OVX. The overall bone formation was comparable between HA and SCP, but with topological differences. The bone area was higher in the defect centre of the HA group, mainly in the OVX, and in the defect periphery of the SCP group, in both non-OVX and OVX. It is concluded that HA and SCP granules result in comparable bone formation in trabecular bone defects. As judged by gene expression and histological analyses, the two materials induced different inflammatory and bone remodelling responses. The modulatory effects are associated with differences in the spatial distribution of the newly formed bone.


Nanomedicine: Nanotechnology, Biology and Medicine | 2013

Osseointegration of titanium with an antimicrobial nanostructured noble metal coating.

Sara Svensson; Felicia Suska; Lena Emanuelsson; Anders Palmquist; Birgitta Norlindh; Margarita Trobos; Helen Bäckros; Linda Persson; Gunilla Rydja; Mattias Ohrlander; Benny Lyvén; Jukka Lausmaa; Peter Thomsen

UNLABELLED Nanometer scale surface features on implants and prostheses can potentially be used to enhance osseointegration and may also add further functionalities, such as infection resistance, to the implant. In this study, a nanostructured noble metal coating consisting of palladium, gold and silver, never previously used in bone applications, was applied to machined titanium screws to evaluate osseointegration after 6 and 12 weeks in rabbit tibiae and femurs. Infection resistance was confirmed by in vitro adhesion test. A qualitatively and quantitatively similar in vivo bone response was observed for the coated and uncoated control screws, using histology, histomorphometry and electron microscopy. The bone-implant interface analysis revealed an extensive bone formation and direct bone-implant contact. These results demonstrate that the nanostructured noble metal coating with antimicrobial properties promotes osseointegration and may therefore be used to add extra implant functionality in the form of increased resistance to infection without the use of antibiotics. FROM THE CLINICAL EDITOR The authors of this paper demonstrate that nanostructured noble metal coating of implants and prostheses used in orthopedic procedures promotes osseointegration and may be used to add extra implant functionality in the form of increased resistance to infection without the use of antibiotics.


Acta Biomaterialia | 2016

Long-term osseointegration of 3D printed CoCr constructs with an interconnected open-pore architecture prepared by electron beam melting

Furqan A. Shah; Omar Omar; Felicia Suska; Anders Snis; Aleksandar Matic; Lena Emanuelsson; Birgitta Norlindh; Jukka Lausmaa; Peter Thomsen; Anders Palmquist

UNLABELLED In orthopaedic surgery, cobalt chromium (CoCr) based alloys are used extensively for their high strength and wear properties, but with concerns over stress shielding and bone resorption due to the high stiffness of CoCr. The structural stiffness, principally related to the bulk and the elastic modulus of the material, may be lowered by appropriate design modifications, to reduce the stiffness mismatch between metal/alloy implants and the adjacent bone. Here, 3D printed CoCr and Ti6Al4V implants of similar macro-geometry and interconnected open-pore architecture prepared by electron beam melting (EBM) were evaluated following 26week implantation in adult sheep femora. Despite higher total bone-implant contact for Ti6Al4V (39±4%) than CoCr (27±4%), bone formation patterns were similar, e.g., densification around the implant, and gradual ingrowth into the porous network, with more bone in the outer half (periphery) than the inner half (centre). Raman spectroscopy revealed no major differences in mineral crystallinity, the apatite-to-collagen ratio, or the carbonate-to-phosphate ratio. Energy dispersive X-ray spectroscopy showed similar Ca/P ratio of the interfacial tissue adjacent to both materials. Osteocytes made direct contact with CoCr and Ti6Al4V. While osteocyte density and distribution in the new-formed bone were largely similar for the two alloys, higher osteocyte density was observed at the periphery of the porous network for CoCr, attributable to slower remodelling and a different biomechanical environment. The results demonstrate the possibility to achieve bone ingrowth into open-pore CoCr constructs, and attest to the potential for fabricating customised osseointegrated CoCr implants for load-bearing applications. STATEMENT OF SIGNIFICANCE Although cobalt chromium (CoCr) based alloys are used extensively in orthopaedic surgery, stress shielding due to the high stiffness of CoCr is of concern. To reduce the stiffness mismatch between CoCr and bone, CoCr and Ti6Al4V implants having an interconnected open-pore architecture were prepared by electron beam melting (EBM). After six months of submerged healing in sheep, both alloys showed similar patterns of bone formation, with densification around the implant and gradual ingrowth into the porous network. The molecular and elemental composition of the interfacial tissue was similar for both alloys. Osteocytes made direct contact with both alloys, with similar overall osteocyte density and distribution. The work attests to the potential for achieving osseointegration of EBM manufactured porous CoCr implants.


Acta Biomaterialia | 2015

Bone response to a novel Ti–Ta–Nb–Zr alloy

Patrik Stenlund; Omar Omar; Ulrika Brohede; Susanne Norgren; Birgitta Norlindh; Anna Johansson; Jukka Lausmaa; Peter Thomsen; Anders Palmquist

Commercially pure titanium (cp-Ti) is regarded as the state-of-the-art material for bone-anchored dental devices, whereas the mechanically stronger alloy (Ti-6Al-4V), made of titanium, aluminum (Al) and vanadium (V), is regarded as the material of choice for high-load applications. There is a call for the development of new alloys, not only to eliminate the potential toxic effect of Al and V but also to meet the challenges imposed on dental and maxillofacial reconstructive devices, for example. The present work evaluates a novel, dual-stage, acid-etched, Ti-Ta-Nb-Zr alloy implant, consisting of elements that create low toxicity, with the potential to promote osseointegration in vivo. The alloy implants (denoted Ti-Ta-Nb-Zr) were evaluated after 7 days and 28 days in a rat tibia model, with reference to commercially pure titanium grade 4 (denoted Ti). Analyses were performed with respect to removal torque, histomorphometry and gene expression. The Ti-Ta-Nb-Zr showed a significant increase in implant stability over time in contrast to the Ti. Further, the histological and gene expression analyses suggested faster healing around the Ti-Ta-Nb-Zr, as judged by the enhanced remodeling, and mineralization, of the early-formed woven bone and the multiple positive correlations between genes denoting inflammation, bone formation and remodeling. Based on the present experiments, it is concluded that the Ti-Ta-Nb-Zr alloy becomes osseointegrated to at least a similar degree to that of pure titanium implants. This alloy is therefore emerging as a novel implant material for clinical evaluation.


Acta Biomaterialia | 2016

Guided bone regeneration using resorbable membrane and different bone substitutes: Early histological and molecular events

Ibrahim Elgali; Alberto Turri; Wei Xia; Birgitta Norlindh; Anna Johansson; Christer Dahlin; Peter Thomsen; Omar Omar

UNLABELLED Bone insufficiency remains a major challenge for bone-anchored implants. The combination of guided bone regeneration (GBR) and bone augmentation is an established procedure to restore the bone. However, a proper understanding of the interactions between the bone substitute and GBR membrane materials and the bone-healing environment is lacking. This study aimed to investigate the early events of bone healing and the cellular activities in response to a combination of GBR membrane and different calcium phosphate (CaP) materials. Defects were created in the trabecular region of rat femurs, and filled with deproteinized bovine bone (DBB), hydroxyapatite (HA) or strontium-doped HA (SrHA) or left empty (sham). All the defects were covered with an extracellular matrix membrane. Defects were harvested after 12h, 3d and 6d for histology/histomorphometry, immunohistochemistry and gene expression analyses. Histology revealed new bone, at 6d, in all the defects. Larger amount of bone was observed in the SrHA-filled defect. This was in parallel with the reduced expression of osteoclastic genes (CR and CatK) and the osteoblast-osteoclast coupling gene (RANKL) in the SrHA defects. Immunohistochemistry indicated fewer osteoclasts in the SrHA defects. The observations of CD68 and periostin-expressing cells in the membrane per se indicated that the membrane may contribute to the healing process in the defect. It is concluded that the bone-promoting effects of Sr in vivo are mediated by a reduction in catabolic and osteoblast-osteoclast coupling processes. The combination of a bioactive membrane and CaP bone substitute material doped with Sr may produce early synergistic effects during GBR. STATEMENT OF SIGNIFICANCE The study provides novel molecular, cellular and structural evidence on the promotion of early bone regeneration in response to synthetic strontium-containing hydroxyapatite (SrHA) substitute, in combination with a resorbable, guided bone regeneration (GBR) membrane. The prevailing view, based mainly upon in vitro data, is that the beneficial effects of Sr are exerted by the stimulation of bone-forming cells (osteoblasts) and the inhibition of bone-resorbing cells (osteoclasts). In contrast, the present study demonstrates that the local effect of Sr in vivo is predominantly via the inhibition of osteoclast number and activity and the reduction of osteoblast-osteoclast coupling. This experimental data will form the basis for clinical studies, using this material as an interesting bone substitute for guided bone regeneration.


Clinical Implant Dentistry and Related Research | 2015

Oxidized Titanium Implants Enhance Osseointegration via Mechanisms Involving RANK/RANKL/OPG Regulation.

Maria Lennerås; Anders Palmquist; Birgitta Norlindh; Lena Emanuelsson; Peter Thomsen; Omar Omar

BACKGROUND The role of implant surface properties for bone formation and bone remodeling, that is, the major events during osseointegration, are incompletely understood. PURPOSE This experimental study aimed to investigate the relation between molecular and morphological patterns at the bone interface for machined and oxidized implants. MATERIALS AND METHODS Machined and anodically oxidized titanium implants were inserted in rat tibiae. The implants and surrounding tissue were retrieved at 1, 3, 6, 14, or 28 days for gene expression, histology, histomorphometry, backscatter scanning electron microscopy, and transmission electron microscopy. RESULTS Compared with machined-surface implants, a higher degree of mineralized bone was found in contact with the oxidized-surface implants. After 3 days, cells adherent to the oxidized implants demonstrated a markedly higher expression of receptor activator of nuclear factor kappa-B (RANK), receptor activator of nuclear factor kappa-B ligand (RANKL), and osteoprotegerin (OPG). Whereas the OPG expression was higher at the machined implants at 6, 14, and 28 days, a higher RANKL/OPG ratio was detected at the oxidized implants. Between 3 and 14 days, both implants demonstrated a temporal increase in RANKL/OPG, corresponding to the remodeling phase at the bone-implant interface. For both implant types, the RANKL/OPG ratio sharply decreased to a low level after 28 days. CONCLUSIONS The present results show that oxidized implants rapidly promote a high degree of mineralized bone apposition to the surface. As determined by the gene expression data, the mechanisms involve an early induction of osteoclastic differentiation and subsequently more intensive bone remodeling, which accelerates the maturation of the bone-implant interface. The present study suggests that the RANKL/OPG ratio is a sensitive indicator for monitoring the remodeling process during osseointegration.


Acta Biomaterialia | 2017

The influence of controlled surface nanotopography on the early biological events of osseointegration

Dimitrios Karazisis; Sarunas Petronis; Hossein Agheli; Lena Emanuelsson; Birgitta Norlindh; Anna Johansson; Lars Rasmusson; Peter Thomsen; Omar Omar

The early cell and tissue interactions with nanopatterned titanium implants are insufficiently described in vivo. A limitation has been to transfer a pre-determined, well-controlled nanotopography to 3D titanium implants, without affecting other surface parameters, including surface microtopography and chemistry. This in vivo study aimed to investigate the early cellular and molecular events at the bone interface with screw-shaped titanium implants superimposed with controlled nanotopography. Polished and machined titanium implants were firstly patterned with 75-nm semispherical protrusions. Polished and machined implants without nano-patterns were designated as controls. Thereafter, all nanopatterned and control implants were sputter-coated with a 30nm titanium layer to unify the surface chemistry. The implants were inserted in rat tibiae and samples were harvested after 12h, 1d and 3d. In one group, the implants were unscrewed and the implant-adherent cells were analyzed using quantitative polymerase chain reaction. In another group, implants with surrounding bone were harvested en bloc for histology and immunohistochemistry. The results showed that nanotopography downregulated the expression of monocyte chemoattractant protein-1 (MCP-1), at 1d, and triggered the expression of osteocalcin (OC) at 3d. This was in parallel with a relatively lower number of recruited CD68-positive macrophages in the tissue surrounding the nanopatterned implants. Moreover, a higher proportion of newly formed osteoid and woven bone was found at the nanopatterned implants at 3d. It is concluded that nanotopography, per se, attenuates the inflammatory process and enhances the osteogenic response during the early phase of osseointegration. This nanotopography-induced effect appeared to be independent of the underlying microscale topography. STATEMENT OF SIGNIFICANCE This study provides a first line of evidence that pre-determined nanopatterns on clinically relevant, screw-shaped, titanium implants can be recognized by cells in the complex in vivo environment. Until now, most of the knowledge relating to cell interactions with nanopatterned surfaces has been acquired from in vitro studies involving mostly two-dimensional nanopatterned surfaces of varying chemical composition. We have managed to superimpose pre-determined nanoscale topography on polished and micro-rough, screw-shaped, implants, without changes in the microscale topography or chemistry. This was achieved by colloidal lithography in combination with a thin titanium film coating on top of both nanopatterned and control implants. The early events of osseointegration were evaluated at the bone interface to these implants. The results revealed that nanotopography, as such, elicits downregulatory effects on the early recruitment and activity of inflammatory cells while enhancing osteogenic activity and woven bone formation.


Biomaterials | 2015

A novel soft tissue model for biomaterial-associated infection and inflammation - Bacteriological, morphological and molecular observations

Sara Svensson; Margarita Trobos; Maria Hoffman; Birgitta Norlindh; Sarunas Petronis; Jukka Lausmaa; Felicia Suska; Peter Thomsen

Infection constitutes a major risk for implant failure, but the reasons why biomaterial sites are more vulnerable than normal tissue are not fully elucidated. In this study, a soft tissue infection model was developed, allowing the analysis of cellular and molecular responses in each of the sub-compartments of the implant-tissue interface (on the implant surface, in the surrounding exudate and in the tissue). Smooth and nanostructured titanium disks with or without noble metal chemistry (silver, gold, palladium), and sham sites, were inoculated with Staphylococcus epidermidis and analysed with respect to number of viable bacteria, number, viability and gene expression of host cells, and using different morphological techniques after 4 h, 24 h and 72 h. Non-infected rats were controls. Results showed a transient inflammatory response at control sites, whereas bacterial administration resulted in higher recruitment of inflammatory cells (mainly polymorphonuclear), higher, continuous cell death and higher gene expression of tumour necrosis factor-alpha, interleukin-6, interleukin-8, Toll-like receptor 2 and elastase. At all time points, S. epidermidis was predominantly located in the interface zone, extra- and intracellularly, and lower levels were detected on the implants compared with surrounding exudate. This model allows detailed analysis of early events in inflammation and infection associated to biomaterials in vivo leading to insights into host defence mechanisms in biomaterial-associated infections.


Acta Orthopaedica | 2014

Retrieved bone-anchored percutaneous amputation prosthesis showing maintained osseointegration after 11 years—a case report

Anders Palmquist; Sara H. Windahl; Birgitta Norlindh; Rickard Brånemark; Peter Thomsen

The patient is a woman born in 1960. She suffered a high transfemoral amputation due to a tumor in 1976. In 1993, she was enrolled for treatment with a custom-designed bone-anchored implant solution. The surgery was performed in 2 stages, Briefly, at stage 1 of surgery (S1), a titanium fixture was implanted in residual femoral bone after reaming of the intramedullary canal, and using a 3-D centering guide and fluoroscopy to ensure proper positioning. At stage 2 of surgery (S2) 6 months later, a full skin thickness flap was trimmed of subcutaneous fat and sutured to the distal end of the femoral bone, essentially according to the surgical technique developed for percutaneous bone-anchored hearing aids (Tjellstrom 1989). In conjunction with S2, a skin-penetrating abutment was inserted into the fixture and secured via an abutment screw. Following S2, the rehabilitation included a gradual increase of the load on the implant, the fitting of an external prosthesis to the abutment, increased activity, and prosthetic use. In 1998, the titanium fixture fractured at the distal end, and a custom-made abutment was installed to try to avoid fixture removal. This abutment failed in 2000, and was exchanged. In 2004, the fixture fractured again due to fatigue, and it was removed. The distal part was loose and was easily removed, while the proximal part was drilled out with a trephine burr together with a surrounding tissue collar. The fixture with surrounding bone was immersed in 4% formalin. The patient was successfully revised with a new implant and has not suffered from any new fracture. Specimen preparation The specimen was dehydrated and embedded in LR White (London Resin Co. Ltd., UK) and divided into 2 pieces through the long axis by use of a diamond band saw. One part was used for preparation of a toluidine blue stained ground section for histological and histomorphometrical analysis using light microscopy. The counter part of the block was divided further into one smaller part at the apical end, containing 7 threads intended for micro-CT analysis in a Skyscan 1172. The rest was polished with grit paper to create an even surface, and then sputter-coated with gold (approximately 10 nm) and analyzed by scanning electron microscopy (SEM).


Journal of the Royal Society Interface | 2012

Bone-titanium oxide interface in humans revealed by transmission electron microscopy and electron tomography

Anders Palmquist; Kathryn Grandfield; Birgitta Norlindh; Torsten Mattsson; Rickard Brånemark; Peter Thomsen

Collaboration


Dive into the Birgitta Norlindh's collaboration.

Top Co-Authors

Avatar

Peter Thomsen

Sahlgrenska University Hospital

View shared research outputs
Top Co-Authors

Avatar

Omar Omar

University of Gothenburg

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jukka Lausmaa

SP Technical Research Institute of Sweden

View shared research outputs
Top Co-Authors

Avatar

Anna Johansson

University of Gothenburg

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Felicia Suska

University of Gothenburg

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ibrahim Elgali

University of Gothenburg

View shared research outputs
Researchain Logo
Decentralizing Knowledge