Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Boris Hyle Park is active.

Publication


Featured researches published by Boris Hyle Park.


Optics Express | 2004

In vivo high-resolution video-rate spectral-domain optical coherence tomography of the human retina and optic nerve

Nader Nassif; Barry Cense; Boris Hyle Park; Mark C. Pierce; Seok Hyun Yun; Brett E. Bouma; Guillermo J. Tearney; Teresa Chen; J. F. de Boer

An ultra-high-speed spectral-domain optical coherence tomography system (SD-OCT) was developed for imaging the human retina and optic nerve in vivo at a sustained depth profile (A-line) acquisition speed of 29 kHz. The axial resolution was 6 microm in tissue and the system had shot-noise-limited performance with a maximum sensitivity of 98.4 dB. 3-dimensional data sets were collected in 11 and 13 seconds for the macula and optic nerve head respectively and are presented to demonstrate the potential clinical applications of SD-OCT in ophthalmology. Additionally, a 3-D volume of the optic nerve head was constructed from the acquired data and the retinal vascular network was visualized.


Optics Express | 2003

In vivo dynamic human retinal blood flow imaging using ultra-high-speed spectral domain optical Doppler tomography

Brian R. White; Mark C. Pierce; Nader Nassif; Barry Cense; Boris Hyle Park; Guillermo J. Tearney; Brett E. Bouma; Teresa Chen; de J.M.C. Boer

An ultra-high-speed spectral domain optical Doppler tomography (SD-ODT) system is used to acquire images of blood flow in a human retina in vivo, at 29,000 depth profiles (A-lines) per second and with data acquisition over 99% of the measurement time. The phase stability of the system is examined and image processing algorithms are presented that allow accurate determination of bi-directional Doppler shifts. Movies are presented of human retinal flow acquired at 29 frames per second with 1000 A-lines per frame over a time period of 3.28 seconds, showing accurate determination of vessel boundaries and time-dependent bi-directional flow dynamics in artery-vein pairs. The ultra-high-speed SD-ODT system allows visualization of the pulsatile nature of retinal blood flow, detects blood flow within the choroid and retinal capillaries, and provides information on the cardiac cycle. In summary, accurate video rate imaging of retinal blood flow dynamics is demonstrated at ocular exposure levels below 600 µW.


Optics Express | 2004

Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography

Barry Cense; Nader Nassif; Teresa C. Chen; Mark C. Pierce; Seok Hyun Yun; Boris Hyle Park; Brett E. Bouma; Guillermo J. Tearney; J. F. de Boer

We present the first ultrahigh-resolution optical coherence tomography (OCT) structural intensity images and movies of the human retina in vivo at 29.3 frames per second with 500 A-lines per frame. Data was acquired at a continuous rate of 29,300 spectra per second with a 98% duty cycle. Two consecutive spectra were coherently summed to improve sensitivity, resulting in an effective rate of 14,600 A-lines per second at an effective integration time of 68 micros. The turn-key source was a combination of two super luminescent diodes with a combined spectral width of more than 150 nm providing 4.5 mW of power. The spectrometer of the spectraldomain OCT (SD-OCT) setup was centered around 885 nm with a bandwidth of 145 nm. The effective bandwidth in the eye was limited to approximately 100 nm due to increased absorption of wavelengths above 920 nm in the vitreous. Comparing the performance of our ultrahighresolution SD-OCT system with a conventional high-resolution time domain OCT system, the A-line rate of the spectral-domain OCT system was 59 times higher at a 5.4 dB lower sensitivity. With use of a software based dispersion compensation scheme, coherence length broadening due to dispersion mismatch between sample and reference arms was minimized. The coherence length measured from a mirror in air was equal to 4.0 microm (n= 1). The coherence length determined from the specular reflection of the foveal umbo in vivo in a healthy human eye was equal to 3.5 microm (n = 1.38). With this new system, two layers at the location of the retinal pigmented epithelium seem to be present, as well as small features in the inner and outer plexiform layers, which are believed to be small blood vessels. ?2004 Optical Society of America.


Optics Letters | 2005

Spectral-domain optical coherence phase microscopy for quantitative phase-contrast imaging

Chulmin Joo; Taner Akkin; Barry Cense; Boris Hyle Park; Johannes F. de Boer

We describe a novel microscopy technique for quantitative phase-contrast imaging of a transparent specimen. The technique is based on depth-resolved phase information provided by common path spectral-domain optical coherence tomography and can measure minute phase variations caused by changes in refractive index and thickness inside the specimen. We demonstrate subnanometer level path-length sensitivity and present images obtained on reflection from a known phase object and human epithelial cheek cells.


Optics Letters | 2002

Spectral shaping for non-Gaussian source spectra in optical coherence tomography

Renu Tripathi; Nader Nassif; J. Stuart Nelson; Boris Hyle Park; Johannes F. de Boer

We present a digital spectral shaping technique to reduce the sidelobes (ringing) of the axial point-spread function in optical coherence tomography for non-Gaussian-shaped source spectra. The spectra of two superluminescent diodes were combined to generate a spectrum with significant modulation. Images of onion cells demonstrate the improved image quality in a turbid biological sample. A quantitative analysis of the accompanying penalty in signal-to-noise ratio is given.


Optics Express | 2008

High-speed polarization sensitive optical frequency domain imaging with frequency multiplexing

Wang-Yuhl Oh; Seok Hyun Yun; Benjamin J. Vakoc; Milen Shishkov; Adrien E. Desjardins; Boris Hyle Park; J. F. de Boer; Guillermo J. Tearney; E. Bouma

Polarization sensitive optical coherence tomography (PS-OCT) provides a cross-sectional image of birefringence in biological samples that is complementary in many applications to the standard reflectance-based image. Recent ex vivo studies have demonstrated that birefringence mapping enables the characterization of collagen and smooth muscle concentration and distribution in vascular tissues. Instruments capable of applying these measurements percutaneously in vivo may provide new insights into coronary atherosclerosis and acute myocardial infarction. We have developed a polarization sensitive optical frequency domain imaging (PS-OFDI) system that enables high-speed intravascular birefringence imaging through a fiber-optic catheter. The novel design of this system utilizes frequency multiplexing to simultaneously measure reflectance of two incident polarization states, overcoming concerns regarding temporal variations of the catheter fiber birefringence and spatial variations in the birefringence of the sample. We demonstrate circular cross-sectional birefringence imaging of a human coronary artery ex vivo through a flexible fiber-optic catheter with an A-line rate of 62 kHz and a ranging depth of 6.2 mm.


Journal of Biomedical Optics | 2000

Optical coherence tomography of the rat cochlea

Brian J. F. Wong; J.F. de Boer; Boris Hyle Park; Zhongping Chen; J.S. Nelson

Optical coherence tomography (OCT) was used to image the internal structure of a rat cochlea (ex vivo). Immediately following sacrifice, the temporal bone of a Sprague-Dawley rat was harvested. Axial OCT cross sectional images (over regions of interest, 1x1 mm-2x8 mm) were obtained with a spatial resolution of 10-15 microm. The osseous borders of the lateral membranous labyrinth overlying the cochlea and the scala vestibuli, media, and tympani, which were well demarcated by the modiolus, Reissners and the basilar membranes, were clearly identified. OCT can be used to image internal structures in the cochlea without violating the osseous labyrinth using simple surgical exposure of the promontory, and may potentially be used to diagnose inner ear pathology in vivo in both animal and human subjects labyrinth.


Optics Express | 2004

Adaptive ranging for optical coherence tomography

Nicusor Iftimia; Brett E. Bouma; J. F. de Boer; Boris Hyle Park; Barry Cense; Guillermo J. Tearney

At present, optical coherence tomography systems have a limited imaging depth or axial scan range, making diagnosis of large diameter arterial vessels and hollow organs difficult. Adaptive ranging is a feedback technique where image data is utilized to adjust the coherence gate offset and range. In this paper, we demonstrate an adaptive optical coherence tomography system with a 7.0 mm range. By matching the imaging depth to the approximately 1.5 mm penetration depth in tissue, a 3 dB sensitivity improvement over conventional imaging systems with a 3.0 mm imaging depth was realized.


Optics Express | 2005

Effects of sample arm motion in endoscopic polarization-sensitive optical coherence tomography

Mark C. Pierce; Milen Shishkov; Boris Hyle Park; Nader Nassif; Brett E. Bouma; Guillermo J. Tearney; J. F. de Boer

Motion of the sample arm fiber in optical coherence tomography (OCT) systems can dynamically alter the polarization state of light incident on tissue during imaging, with consequences for both conventional and polarization-sensitive (PS-)OCT. Endoscopic OCT is particularly susceptible to polarization-related effects, since in most cases, the transverse scanning mechanism involves motion of the sample arm optical fiber to create an image. We investigated the effects of a scanning sample arm fiber on the polarization state of light in an OCT system, and demonstrate that by referencing the state backscattered from within a sample to the measured state at the surface, changes in polarization state due to sample fiber motion can be isolated. The technique is demonstrated by high-speed PS-OCT imaging at 1 frame per second, with both linear and rotary scanning fiber-optic probes. Measurements were made on a calibrated wave plate, and endoscopic PS-OCT images of ex-vivo human tissues are also presented, allowing comparison with features in histologic sections.


Optics Express | 2006

Optical frequency domain imaging with a rapidly swept laser in the 815-870 nm range

H.D. Lim; de J.F. Boer; Boris Hyle Park; Eugine Lee; Ronit Yelin; Seok Hyun Yun

Optical frequency domain imaging (OFDI) in the 800-nm biological imaging window is demonstrated by using a novel wavelength-swept laser source. The laser output is tuned continuously from 815 to 870 nm at a 43.2-kHz repetition rate with 7-mW average power. Axial resolution of 10-mum in biological tissue and peak sensitivity of 96 dB are achieved. In vivo imaging of Xenopus laevis is demonstrated with an acquisition speed of 84 frames per second (512 axial lines per frame). This new imaging technique may prove useful in comprehensive retinal screening for medical diagnosis and contrast-agent-based imaging for biological investigations.

Collaboration


Dive into the Boris Hyle Park's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Barry Cense

Indiana University Bloomington

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Teresa C. Chen

Massachusetts Eye and Ear Infirmary

View shared research outputs
Researchain Logo
Decentralizing Knowledge