Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Bragi Sveinsson is active.

Publication


Featured researches published by Bragi Sveinsson.


Magnetic Resonance in Medicine | 2017

Imaging and T2 relaxometry of short-T2 connective tissues in the knee using ultrashort echo-time double-echo steady-state (UTEDESS)

Akshay S. Chaudhari; Bragi Sveinsson; Catherine J. Moran; Emily J. McWalter; Ethan M. Johnson; Tao Zhang; Garry E. Gold; Brian A. Hargreaves

To develop a radial, double‐echo steady‐state (DESS) sequence with ultra‐short echo‐time (UTE) capabilities for T2 measurement of short‐T2 tissues along with simultaneous rapid, signal‐to‐noise ratio (SNR)‐efficient, and high‐isotropic‐resolution morphological knee imaging.


Magnetic Resonance Imaging | 2017

A simple analytic method for estimating T2 in the knee from DESS

Bragi Sveinsson; Akshay S. Chaudhari; Garry E. Gold; Brian A. Hargreaves

PURPOSE To introduce a simple analytical formula for estimating T2 from a single Double-Echo in Steady-State (DESS) scan. METHODS Extended Phase Graph (EPG) modeling was used to develop a straightforward linear approximation of the relationship between the two DESS signals, enabling accurate T2 estimation from one DESS scan. Simulations were performed to demonstrate cancellation of different echo pathways to validate this simple model. The resulting analytic formula was compared to previous methods for T2 estimation using DESS and fast spin-echo scans in agar phantoms and knee cartilage in three volunteers and three patients. The DESS approach allows 3D (256×256×44) T2-mapping with fat suppression in scan times of 3-4min. RESULTS The simulations demonstrated that the model approximates the true signal very well. If the T1 is within 20% of the assumed T1, the T2 estimation error was shown to be less than 5% for typical scans. The inherent residual error in the model was demonstrated to be small both due to signal decay and opposing signal contributions. The estimated T2 from the linear relationship agrees well with reference scans, both for the phantoms and in vivo. The method resulted in less underestimation of T2 than previous single-scan approaches, with processing times 60 times faster than using a numerical fit. CONCLUSION A simplified relationship between the two DESS signals allows for rapid 3D T2 quantification with DESS that is accurate, yet also simple. The simplicity of the method allows for immediate T2 estimation in cartilage during the MRI examination.


Magnetic Resonance in Medicine | 2015

Hexagonal undersampling for faster MRI near metallic implants

Bragi Sveinsson; Pauline W. Worters; Garry E. Gold; Brian A. Hargreaves

Slice encoding for metal artifact correction acquires a three‐dimensional image of each excited slice with view‐angle tilting to reduce slice and readout direction artifacts respectively, but requires additional imaging time. The purpose of this study was to provide a technique for faster imaging around metallic implants by undersampling k‐space.


Magnetic Resonance in Medicine | 2018

SNR-weighted regularization of ADC estimates from double-echo in steady-state (DESS)

Bragi Sveinsson; Garry E. Gold; Brian A. Hargreaves; Daehyun Yoon

To improve the homogeneity and consistency of apparent diffusion coefficient (ADC) estimates in cartilage from the double‐echo in steady‐state (DESS) sequence by applying SNR‐weighted regularization during post‐processing.


Magnetic Resonance in Medicine | 2015

Hexagonal Undersampling for Faster MR Imaging near Metallic Implants

Bragi Sveinsson; Pauline W. Worters; Garry E. Gold; Brian A. Hargreaves

Slice encoding for metal artifact correction acquires a three‐dimensional image of each excited slice with view‐angle tilting to reduce slice and readout direction artifacts respectively, but requires additional imaging time. The purpose of this study was to provide a technique for faster imaging around metallic implants by undersampling k‐space.


Magnetic Resonance in Medicine | 2015

Hexagonal undersampling for faster MRI near metallic implants: Hexagonal Sampling for Faster MRI Near Metal Implants

Bragi Sveinsson; Pauline W. Worters; Garry E. Gold; Brian A. Hargreaves

Slice encoding for metal artifact correction acquires a three‐dimensional image of each excited slice with view‐angle tilting to reduce slice and readout direction artifacts respectively, but requires additional imaging time. The purpose of this study was to provide a technique for faster imaging around metallic implants by undersampling k‐space.


Archive | 2013

Distortion-free magnetic resonance imaging near metallic implants

Bragi Sveinsson; Brian A. Hargreaves


Osteoarthritis and Cartilage | 2014

Non-contrast diffusion weighted imaging for the assessment of knee synovitis: a comparative study against contrast-enhanced MRI

Edwin H. G. Oei; Emily J. McWalter; Bragi Sveinsson; Marcus T. Alley; Brian A. Hargreaves; Garry E. Gold


Archive | 2017

METHOD FOR ESTIMATING T2

Brian A. Hargreaves; Bragi Sveinsson


Osteoarthritis and Cartilage | 2015

Automated, non-contrast MRI for detection of synovitis using diffusion-weighted dess

Audrey P. Fan; G. Fong; Bragi Sveinsson; Emily J. McWalter; Edwin H. G. Oei; William H. Robinson; Mark C. Genovese; Brian A. Hargreaves; Garry E. Gold

Collaboration


Dive into the Bragi Sveinsson's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Nikola Stikov

École Polytechnique de Montréal

View shared research outputs
Top Co-Authors

Avatar

Edwin H. G. Oei

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge