Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Bruno Tesini Roseguini is active.

Publication


Featured researches published by Bruno Tesini Roseguini.


Revista Brasileira De Medicina Do Esporte | 2005

Limiar ventilatório e variabilidade da freqüência cardíaca em adolescentes

Antonio Fernando Brunetto; Bruno Moreira Silva; Bruno Tesini Roseguini; Daniel Müller Hirai; Dartagnan Pinto Guedes

The analysis of blood lactate concentration and pulmonary gas exchanges are methods traditionally employed to identify the transition in the muscle metabolism energy production. However, the analysis of heart rate variability has been recently suggested as an alternative method. The objective of the present study was to compare the heart rate variability threshold (HRVT) with the ventilatory threshold (VT) in a sample of adolescents. Forty-one subjects (22 boys and 19 girls) with age between 15 and 18 years were submitted to a maximal exercise test in a treadmill (modified Bruce protocol). The VT was identified using the ventilatory equivalent of oxygen by means of ergospirometry resources. The heart rate variability was analyzed from the R-R intervals, through the Poincare plot, which provides information with regard to the standard deviation of the instantaneous beat-to-beat variability (SD1), the standard deviation of the long-term continuous R-R intervals (SD2) and the SD1/SD2 ratio. The HRVT was identified according to three criteria: (1) difference lower than 1 ms in the SD1 between two consecutive exercise levels; (2) SD1 lower than 3 ms; and (3) occurrence of both criteria simultaneously. Through the analysis of the results it was verified that the R-R intervals and the SD2 reduced progressively at each 10% interval of VO2peak until the end of the physical effort (0.05 < p < 0.01). The SD1 reduced significantly since 20% until 50% of VO2peak. From 60% until the VO2peak there was no significant difference in the SD1. The SD1/SD2 ratio began to increase at 60%. The VT occurred at 54.4 ± 8.8% of VO2peak, while the HRVT occurred at 52.4 ± 12.5%, 57.0 ± 14.1% and 57.8 ± 13.8% of VO2peak, for criteria 1, 2 and 3, respectively. No significant differences between the VT and the three criteria used for HRVT identification were observed. Significant product-moment correlation coefficients were found between the HRVT identified by the three criteria and the VT, when VO2 absolute values were analyzed. However, there was no statistically significant correlation between the HRVT and the VT when expressed in proportion of VO2peak. In short, it seems early to apply the HRVT as an alternative method in the adolescents VT identification.As analises da concentracao sanguinea de lactato e das trocas gasosas respiratorias sao metodos tradicionalmente empregados para identificar a transicao de producao de energia pelo metabolismo muscular. No entanto, mais recentemente, vem sendo sugerido metodo alternativo mediante analise da variabilidade da frequencia cardiaca. Pretendeu-se, com o presente estudo, estabelecer comparacoes entre o limiar de variabilidade da frequencia cardiaca (LiVFC) e o primeiro limiar ventilatorio (LV1), em uma amostra de adolescentes. Para tanto, foram submetidos a teste de esforco fisico de carga maxima em esteira ergometrica 41 sujeitos (22 rapazes e 19 mocas) com idades entre 15 e 18 anos. O LV1 foi identificado mediante o equivalente ventilatorio de oxigenio envolvendo recursos de ergoespirometria. A variabilidade da frequencia cardiaca foi analisada por intermedio dos intervalos R-R, atraves da plotagem de Poincare, que oferece informacoes quanto ao desvio-padrao da variabilidade instantânea batimento-a-batimento (SD1), ao desvio-padrao a longo prazo de intervalos R-R continuos (SD2) e a razao SD1/SD2. O LiVFC foi identificado pelo SD1 de acordo com tres criterios: (1) diferencas entre o SD1 de dois estagios consecutivos menor que 1ms; (2) SD1 menor que 3ms; e (3) ocorrencia de ambos os criterios em conjunto. Mediante analise dos resultados verificou-se que os intervalos R-R e SD2 diminuiram progressivamente a cada intervalo de 10% do VO2pico ate o final do teste de esforco fisico (0,05 < p < 0,01). O SD1 diminuiu significativamente desde 20% ate 50% do VO2pico. A partir de 60% ate o VO2pico o SD1 nao apresentou diferencas significativas. A razao SD1/SD2 aumentou a partir de 60%. O LV1 ocorreu a 54,4 ± 8,8% do VO2pico enquanto o LiVFC, a 52,4 ± 12,5%, 57,0 ± 14,1% e 57,8 ± 13,8% do VO2 pico, para os criterios 1, 2 e 3, respectivamente. Nao foram observadas diferencas estatisticas entre o LV1 e os tres criterios utilizados para identificacao do LiVFC. Observaram-se coeficientes de correlacao momento-produto significativos entre o LiVFC identificado mediante os tres criterios considerados e o LV1, quando foram utilizados os valores absolutos de VO2. Porem, nao foram encontradas correlacoes estatisticas significativas entre o LiVFC e a identificacao do LV1 expresso em proporcao do VO2pico. Em assim sendo, concluiu-se que parece ser precipitado tentar empregar o LiVFC como metodo alternativo na identificacao do LV1 de adolescentes.


Revista Da Associacao Medica Brasileira | 2005

Respostas autonômicas cardíacas à manobra de tilt em adolescentes obesos

Antonio Fernando Brunetto; Bruno Tesini Roseguini; Bruno Moreira Silva; Daniel Müller Hirai; Dartagnan Pinto Guedes

INTRODUCAO: A obesidade esta associada as alteracoes do sistema nervoso autonomo. Estudos previos em adultos tem mostrado que obesos apresentam resposta autonomica cardiaca diminuida frente a mudancas posturais. Contudo, pouco se sabe sobre o impacto do sobrepeso na adolescencia quanto as respostas autonomicas ao estresse postural passivo. OBJETIVO: Comparar as respostas autonomicas cardiacas a manobra de tilt entre adolescentes obesos e nao-obesos mediante analise da variabilidade da frequencia cardiaca (VFC). METODOS: Quatorze adolescentes obesos (15,5±1,6 anos) foram comparados com 20 adolescentes nao-obesos (15,4±0,8 anos). A modulacao autonomica cardiaca foi estudada mediante analise da variabilidade da frequencia cardiaca de trechos de cinco minutos de registro de intervalos RR antes e depois da inclinacao da mesa de tilt a 70o. A VFC foi estudada no dominio do tempo (DT) e no dominio da frequencia (DF). Os componentes espectrais foram estudados na baixa (LF) e na alta frequencia (HF) e pela razao LF/HF. RESULTADOS: Adolescentes obesos demonstraram menor HF em unidades normalizadas (38,2±11.1 vs 53,9±15,5, p<0,05) e maior LF em unidades normalizadas (60,7±11,3 vs 44,6±15,7, p<0,05) na posicao supina. Nenhuma diferenca foi encontrada nos parâmetros da VFC apos a manobra de tilt. Ao comparar a diferenca entre as posicoes ortostatica e supino, os adolescentes obesos apresentaram menores mudancas de LF unidades normalizadas (22,4±12,6 vs 38±16,4, p<0,05) e HF unidades normalizadas (-21,9±12,4 vs _37,3±16,3, p<0,05). CONCLUSAO: Adolescentes obesos apresentaram uma resposta autonomica cardiaca alterada frente ao estresse postural, caracterizada principalmente por uma hiporesponsividade vagal.


Revista Brasileira De Medicina Do Esporte | 2005

O limiar de esforço percebido (LEP) corresponde à potência crítica e a um indicador de máximo estado estável de consumo de oxigênio

Fábio Yuzo Nakamura; Antonio Fernando Brunetto; Daniel Müller Hirai; Bruno Tesini Roseguini; Eduardo Kokubun

O esforco percebido tem sido alvo de diversas investigacoes, geralmente associando-o a indicadores fisiologicos objetivos no exercicio. Recentemente, foi proposta a identificacao do limiar de esforco percebido (LEP) em corrida aquatica, o qual nao diferiu da velocidade critica. Em tese, ambos os parâmetros seriam indicadores de maximo estado estavel de variaveis como o VO2 e lactato sanguineo. Este trabalho teve como objetivo verificar a coincidencia entre LEP, potencia critica (PCrit) e um indicador de maximo estado estavel de VO2 (PCrit) em cicloergometro. Oito participantes do sexo masculino foram submetidos a teste de esforco progressivo, para determinacao do VO2pico (46,7 ± 8,5ml/kg/min), e a quatro testes retangulares exaustivos para estimativa dos parâmetros do modelo de potencia critica, LEP e PCrit. A relacao hiperbolica entre potencia mecânica e tempo ate que o VO2pico fosse alcancado em cada teste foi utilizada para a estimativa da PCrit, tida como a assintota no eixo da potencia, e a porcao da capacidade de trabalho anaerobio (CTAnaer) depletada ate o estabelecimento do VO2pico (CTAnaer). Para identificar o LEP, os coeficientes angulares das retas do aumento do esforco percebido no tempo (ordenada) e as potencias utilizadas (abscissa) foram ajustados a uma funcao linear que fornecia um ponto no eixo da potencia em que o esforco percebido seria mantido estavel indefinidamente. Os parâmetros PCrit e CTAnaer foram estimados por meio da equacao nao linear potencia-tempo. Para comparacao das estimativas de LEP, PCrit e PCrit foi empregada ANOVA para medidas repetidas e as associacoes foram estabelecidas por correlacao de Pearson. CTAnaer e CTAnaer foram comparadas por teste t. O LEP (180W ± 61W), PCrit (174W ± 43W) e PCrit (176W ± 48W) nao diferiram significantemente e as correlacoes foram de 0,92-0,98. CTAnaer (14.080 ± 5.219J) foi menor que CTAnaer (22.093 ± 9.042J). Conclui-se que o LEP prediz de forma acurada a intensidade de PCrit e PCrit.


Pediatric Cardiology | 2005

Effects of gender and aerobic fitness on cardiac autonomic responses to head-up tilt in healthy adolescents.

Antonio Fernando Brunetto; Bruno Tesini Roseguini; Bruno Moreira Silva; Daniel Müller Hirai; Dartagnan Pinto Guedes

Cardiovascular autonomic responses to orthostatic challenges are affected by gender and cardiorespiratory fitness in adults. However, little is know about the effects of these factors in healthy adolescents. We studied 41 adolescents (20 boys and 21 girls) aged 12-17 years, divided into aerobic fitness tertiles based on the results of a maximal treadmill exercise test. Cardiac autonomic modulation was assessed by heart rate variability (HRV) analysis of 5-minute RR interval recordings before and after 70° head-up tilt maneuver. HRV was analyzed by time (TD) and frequency domain (FD) methods. TD was analyzed by standard deviation of the RR intervals and the root mean square of successive differences of RR intervals. The power spectral components were studied at low (LF) and high (HF) frequencies and as the LF/HF ratio. We did not find any differences in TD and FD measures before and after tilt in either gender or fitness groups, except for a higher heart rate response for boys. These results suggests that cardiac autonomic responses to head-up tilt in healthy adolescents are not affected by gender or aerobic fitness.


Revista Brasileira De Medicina Do Esporte | 2008

Limiar de variabilidade da freqüência cardíaca em adolecentes obesos e não-obesos

Antonio Fernando Brunetto; Bruno Tesini Roseguini; Bruno Moreira Silva; Daniel Müller Hirai; Enio Ricardo Vaz Ronque; Dartagnan Pinto Guedes

Obesity in adolescence is associated with a cardiac sympathetic-parasympathetic dysfunction at rest. However, there is little information about the autonomic response during exercise in these adolescents. OBJECTIVE: To compare the cardiac autonomic modulation during a maximal exercise test in obese and non-obese adolescents and analyze the association between the Heart Rate Variability threshold (HRVT) and the Ventilatory threshold (VT). METHODS: Ten obese and 19 non-obese male adolescents with age between 13-18 years were submitted to a maximal progressive treadmill physical exercise test for Heart Rate Variability (HRV) study and VT determination. HRV was assessed through the study of Poincare Plot, by the analysis of the standard deviation of instantaneous beat-to-beat variability (SD1). HRVT was defined as the effort intensity at which the SD1 reached less than 3 ms. RESULTS: The SD1 index reduced progressively in both groups until approximately 50-60% of VO2peak, while the obese adolescents showed lower significant values (p<0.001) only in the relative intensity of 20% of VO2peak. The obese adolescents showed relative values (mL.kg-1.min-1) of VO2peak and VT significantly lower (p<0.05) than non-obese ones. There were no significant differences between VT and HRVT, expressed in absolute and relative VO2 values for neither groups. However, no significant correlations between VT and HRVT were found, neither in absolute nor relative values. CONCLUSIONS: Obesity in adolescence does not seem to be associated with the autonomic modulation during physical exercise. It is possible to determine the HRVT by Poincare Plot in obese and non-obese adolescents. Nonetheless, the absence of statistical association between HRVT and VT suggests a lack of causal relationship between these events.


Revista Brasileira De Medicina Do Esporte | 2005

Ventilatory threshold and heart rate variability in adolescents

Antonio Fernando Brunetto; Bruno Moreira Silva; Bruno Tesini Roseguini; Daniel Müller Hirai; Dartagnan Pinto Guedes

The analysis of blood lactate concentration and pulmonary gas exchanges are methods traditionally employed to identify the transition in the muscle metabolism energy production. However, the analysis of heart rate variability has been recently suggested as an alternative method. The objective of the present study was to compare the heart rate variability threshold (HRVT) with the ventilatory threshold (VT) in a sample of adolescents. Forty-one subjects (22 boys and 19 girls) with age between 15 and 18 years were submitted to a maximal exercise test in a treadmill (modified Bruce protocol). The VT was identified using the ventilatory equivalent of oxygen by means of ergospirometry resources. The heart rate variability was analyzed from the R-R intervals, through the Poincare plot, which provides information with regard to the standard deviation of the instantaneous beat-to-beat variability (SD1), the standard deviation of the long-term continuous R-R intervals (SD2) and the SD1/SD2 ratio. The HRVT was identified according to three criteria: (1) difference lower than 1 ms in the SD1 between two consecutive exercise levels; (2) SD1 lower than 3 ms; and (3) occurrence of both criteria simultaneously. Through the analysis of the results it was verified that the R-R intervals and the SD2 reduced progressively at each 10% interval of VO2peak until the end of the physical effort (0.05 < p < 0.01). The SD1 reduced significantly since 20% until 50% of VO2peak. From 60% until the VO2peak there was no significant difference in the SD1. The SD1/SD2 ratio began to increase at 60%. The VT occurred at 54.4 ± 8.8% of VO2peak, while the HRVT occurred at 52.4 ± 12.5%, 57.0 ± 14.1% and 57.8 ± 13.8% of VO2peak, for criteria 1, 2 and 3, respectively. No significant differences between the VT and the three criteria used for HRVT identification were observed. Significant product-moment correlation coefficients were found between the HRVT identified by the three criteria and the VT, when VO2 absolute values were analyzed. However, there was no statistically significant correlation between the HRVT and the VT when expressed in proportion of VO2peak. In short, it seems early to apply the HRVT as an alternative method in the adolescents VT identification.As analises da concentracao sanguinea de lactato e das trocas gasosas respiratorias sao metodos tradicionalmente empregados para identificar a transicao de producao de energia pelo metabolismo muscular. No entanto, mais recentemente, vem sendo sugerido metodo alternativo mediante analise da variabilidade da frequencia cardiaca. Pretendeu-se, com o presente estudo, estabelecer comparacoes entre o limiar de variabilidade da frequencia cardiaca (LiVFC) e o primeiro limiar ventilatorio (LV1), em uma amostra de adolescentes. Para tanto, foram submetidos a teste de esforco fisico de carga maxima em esteira ergometrica 41 sujeitos (22 rapazes e 19 mocas) com idades entre 15 e 18 anos. O LV1 foi identificado mediante o equivalente ventilatorio de oxigenio envolvendo recursos de ergoespirometria. A variabilidade da frequencia cardiaca foi analisada por intermedio dos intervalos R-R, atraves da plotagem de Poincare, que oferece informacoes quanto ao desvio-padrao da variabilidade instantânea batimento-a-batimento (SD1), ao desvio-padrao a longo prazo de intervalos R-R continuos (SD2) e a razao SD1/SD2. O LiVFC foi identificado pelo SD1 de acordo com tres criterios: (1) diferencas entre o SD1 de dois estagios consecutivos menor que 1ms; (2) SD1 menor que 3ms; e (3) ocorrencia de ambos os criterios em conjunto. Mediante analise dos resultados verificou-se que os intervalos R-R e SD2 diminuiram progressivamente a cada intervalo de 10% do VO2pico ate o final do teste de esforco fisico (0,05 < p < 0,01). O SD1 diminuiu significativamente desde 20% ate 50% do VO2pico. A partir de 60% ate o VO2pico o SD1 nao apresentou diferencas significativas. A razao SD1/SD2 aumentou a partir de 60%. O LV1 ocorreu a 54,4 ± 8,8% do VO2pico enquanto o LiVFC, a 52,4 ± 12,5%, 57,0 ± 14,1% e 57,8 ± 13,8% do VO2 pico, para os criterios 1, 2 e 3, respectivamente. Nao foram observadas diferencas estatisticas entre o LV1 e os tres criterios utilizados para identificacao do LiVFC. Observaram-se coeficientes de correlacao momento-produto significativos entre o LiVFC identificado mediante os tres criterios considerados e o LV1, quando foram utilizados os valores absolutos de VO2. Porem, nao foram encontradas correlacoes estatisticas significativas entre o LiVFC e a identificacao do LV1 expresso em proporcao do VO2pico. Em assim sendo, concluiu-se que parece ser precipitado tentar empregar o LiVFC como metodo alternativo na identificacao do LV1 de adolescentes.


Revista Brasileira De Medicina Do Esporte | 2005

The perceived exertion threshold (PET) corresponds to the critical power and to an indicator of maximal oxygen uptake steady state

Fábio Yuzo Nakamura; Antonio Fernando Brunetto; Daniel Müller Hirai; Bruno Tesini Roseguini; Eduardo Kokubun

O esforco percebido tem sido alvo de diversas investigacoes, geralmente associando-o a indicadores fisiologicos objetivos no exercicio. Recentemente, foi proposta a identificacao do limiar de esforco percebido (LEP) em corrida aquatica, o qual nao diferiu da velocidade critica. Em tese, ambos os parâmetros seriam indicadores de maximo estado estavel de variaveis como o VO2 e lactato sanguineo. Este trabalho teve como objetivo verificar a coincidencia entre LEP, potencia critica (PCrit) e um indicador de maximo estado estavel de VO2 (PCrit) em cicloergometro. Oito participantes do sexo masculino foram submetidos a teste de esforco progressivo, para determinacao do VO2pico (46,7 ± 8,5ml/kg/min), e a quatro testes retangulares exaustivos para estimativa dos parâmetros do modelo de potencia critica, LEP e PCrit. A relacao hiperbolica entre potencia mecânica e tempo ate que o VO2pico fosse alcancado em cada teste foi utilizada para a estimativa da PCrit, tida como a assintota no eixo da potencia, e a porcao da capacidade de trabalho anaerobio (CTAnaer) depletada ate o estabelecimento do VO2pico (CTAnaer). Para identificar o LEP, os coeficientes angulares das retas do aumento do esforco percebido no tempo (ordenada) e as potencias utilizadas (abscissa) foram ajustados a uma funcao linear que fornecia um ponto no eixo da potencia em que o esforco percebido seria mantido estavel indefinidamente. Os parâmetros PCrit e CTAnaer foram estimados por meio da equacao nao linear potencia-tempo. Para comparacao das estimativas de LEP, PCrit e PCrit foi empregada ANOVA para medidas repetidas e as associacoes foram estabelecidas por correlacao de Pearson. CTAnaer e CTAnaer foram comparadas por teste t. O LEP (180W ± 61W), PCrit (174W ± 43W) e PCrit (176W ± 48W) nao diferiram significantemente e as correlacoes foram de 0,92-0,98. CTAnaer (14.080 ± 5.219J) foi menor que CTAnaer (22.093 ± 9.042J). Conclui-se que o LEP prediz de forma acurada a intensidade de PCrit e PCrit.


Revista Brasileira De Medicina Do Esporte | 2005

Umbral ventilatorio y variabilidad de la frecuencia cardíaca en los adolescentes

Antonio Fernando Brunetto; Bruno Moreira Silva; Bruno Tesini Roseguini; Daniel Müller Hirai; Dartagnan Pinto Guedes

The analysis of blood lactate concentration and pulmonary gas exchanges are methods traditionally employed to identify the transition in the muscle metabolism energy production. However, the analysis of heart rate variability has been recently suggested as an alternative method. The objective of the present study was to compare the heart rate variability threshold (HRVT) with the ventilatory threshold (VT) in a sample of adolescents. Forty-one subjects (22 boys and 19 girls) with age between 15 and 18 years were submitted to a maximal exercise test in a treadmill (modified Bruce protocol). The VT was identified using the ventilatory equivalent of oxygen by means of ergospirometry resources. The heart rate variability was analyzed from the R-R intervals, through the Poincare plot, which provides information with regard to the standard deviation of the instantaneous beat-to-beat variability (SD1), the standard deviation of the long-term continuous R-R intervals (SD2) and the SD1/SD2 ratio. The HRVT was identified according to three criteria: (1) difference lower than 1 ms in the SD1 between two consecutive exercise levels; (2) SD1 lower than 3 ms; and (3) occurrence of both criteria simultaneously. Through the analysis of the results it was verified that the R-R intervals and the SD2 reduced progressively at each 10% interval of VO2peak until the end of the physical effort (0.05 < p < 0.01). The SD1 reduced significantly since 20% until 50% of VO2peak. From 60% until the VO2peak there was no significant difference in the SD1. The SD1/SD2 ratio began to increase at 60%. The VT occurred at 54.4 ± 8.8% of VO2peak, while the HRVT occurred at 52.4 ± 12.5%, 57.0 ± 14.1% and 57.8 ± 13.8% of VO2peak, for criteria 1, 2 and 3, respectively. No significant differences between the VT and the three criteria used for HRVT identification were observed. Significant product-moment correlation coefficients were found between the HRVT identified by the three criteria and the VT, when VO2 absolute values were analyzed. However, there was no statistically significant correlation between the HRVT and the VT when expressed in proportion of VO2peak. In short, it seems early to apply the HRVT as an alternative method in the adolescents VT identification.As analises da concentracao sanguinea de lactato e das trocas gasosas respiratorias sao metodos tradicionalmente empregados para identificar a transicao de producao de energia pelo metabolismo muscular. No entanto, mais recentemente, vem sendo sugerido metodo alternativo mediante analise da variabilidade da frequencia cardiaca. Pretendeu-se, com o presente estudo, estabelecer comparacoes entre o limiar de variabilidade da frequencia cardiaca (LiVFC) e o primeiro limiar ventilatorio (LV1), em uma amostra de adolescentes. Para tanto, foram submetidos a teste de esforco fisico de carga maxima em esteira ergometrica 41 sujeitos (22 rapazes e 19 mocas) com idades entre 15 e 18 anos. O LV1 foi identificado mediante o equivalente ventilatorio de oxigenio envolvendo recursos de ergoespirometria. A variabilidade da frequencia cardiaca foi analisada por intermedio dos intervalos R-R, atraves da plotagem de Poincare, que oferece informacoes quanto ao desvio-padrao da variabilidade instantânea batimento-a-batimento (SD1), ao desvio-padrao a longo prazo de intervalos R-R continuos (SD2) e a razao SD1/SD2. O LiVFC foi identificado pelo SD1 de acordo com tres criterios: (1) diferencas entre o SD1 de dois estagios consecutivos menor que 1ms; (2) SD1 menor que 3ms; e (3) ocorrencia de ambos os criterios em conjunto. Mediante analise dos resultados verificou-se que os intervalos R-R e SD2 diminuiram progressivamente a cada intervalo de 10% do VO2pico ate o final do teste de esforco fisico (0,05 < p < 0,01). O SD1 diminuiu significativamente desde 20% ate 50% do VO2pico. A partir de 60% ate o VO2pico o SD1 nao apresentou diferencas significativas. A razao SD1/SD2 aumentou a partir de 60%. O LV1 ocorreu a 54,4 ± 8,8% do VO2pico enquanto o LiVFC, a 52,4 ± 12,5%, 57,0 ± 14,1% e 57,8 ± 13,8% do VO2 pico, para os criterios 1, 2 e 3, respectivamente. Nao foram observadas diferencas estatisticas entre o LV1 e os tres criterios utilizados para identificacao do LiVFC. Observaram-se coeficientes de correlacao momento-produto significativos entre o LiVFC identificado mediante os tres criterios considerados e o LV1, quando foram utilizados os valores absolutos de VO2. Porem, nao foram encontradas correlacoes estatisticas significativas entre o LiVFC e a identificacao do LV1 expresso em proporcao do VO2pico. Em assim sendo, concluiu-se que parece ser precipitado tentar empregar o LiVFC como metodo alternativo na identificacao do LV1 de adolescentes.


Revista Brasileira De Medicina Do Esporte | 2005

El umbral de esfuerzo percibido (UEP) corresponde a la potencia crítica y a un indicador de máximo estado estable de consumo de oxigeno

Fábio Yuzo Nakamura; Antonio Fernando Brunetto; Daniel Müller Hirai; Bruno Tesini Roseguini; Eduardo Kokubun

O esforco percebido tem sido alvo de diversas investigacoes, geralmente associando-o a indicadores fisiologicos objetivos no exercicio. Recentemente, foi proposta a identificacao do limiar de esforco percebido (LEP) em corrida aquatica, o qual nao diferiu da velocidade critica. Em tese, ambos os parâmetros seriam indicadores de maximo estado estavel de variaveis como o VO2 e lactato sanguineo. Este trabalho teve como objetivo verificar a coincidencia entre LEP, potencia critica (PCrit) e um indicador de maximo estado estavel de VO2 (PCrit) em cicloergometro. Oito participantes do sexo masculino foram submetidos a teste de esforco progressivo, para determinacao do VO2pico (46,7 ± 8,5ml/kg/min), e a quatro testes retangulares exaustivos para estimativa dos parâmetros do modelo de potencia critica, LEP e PCrit. A relacao hiperbolica entre potencia mecânica e tempo ate que o VO2pico fosse alcancado em cada teste foi utilizada para a estimativa da PCrit, tida como a assintota no eixo da potencia, e a porcao da capacidade de trabalho anaerobio (CTAnaer) depletada ate o estabelecimento do VO2pico (CTAnaer). Para identificar o LEP, os coeficientes angulares das retas do aumento do esforco percebido no tempo (ordenada) e as potencias utilizadas (abscissa) foram ajustados a uma funcao linear que fornecia um ponto no eixo da potencia em que o esforco percebido seria mantido estavel indefinidamente. Os parâmetros PCrit e CTAnaer foram estimados por meio da equacao nao linear potencia-tempo. Para comparacao das estimativas de LEP, PCrit e PCrit foi empregada ANOVA para medidas repetidas e as associacoes foram estabelecidas por correlacao de Pearson. CTAnaer e CTAnaer foram comparadas por teste t. O LEP (180W ± 61W), PCrit (174W ± 43W) e PCrit (176W ± 48W) nao diferiram significantemente e as correlacoes foram de 0,92-0,98. CTAnaer (14.080 ± 5.219J) foi menor que CTAnaer (22.093 ± 9.042J). Conclui-se que o LEP prediz de forma acurada a intensidade de PCrit e PCrit.


Lecturas: Educación física y deportes | 2006

Objetividade da medida do limiar ventilatório

Bruno M. Silva; Bruno Tesini Roseguini; Antonio Fernando Brunetto; Fábio Yuzo Nakamura; Daniel Müller Hirai; Bruna Camargo Brunetto

Collaboration


Dive into the Bruno Tesini Roseguini's collaboration.

Top Co-Authors

Avatar

Antonio Fernando Brunetto

Universidade Estadual de Londrina

View shared research outputs
Top Co-Authors

Avatar

Daniel Müller Hirai

Universidade Estadual de Londrina

View shared research outputs
Top Co-Authors

Avatar

Bruno Moreira Silva

Universidade Estadual de Londrina

View shared research outputs
Top Co-Authors

Avatar

Dartagnan Pinto Guedes

Universidade Estadual de Londrina

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Eduardo Kokubun

Universidade Estadual de Londrina

View shared research outputs
Top Co-Authors

Avatar

Bruna Camargo Brunetto

Universidade Estadual de Londrina

View shared research outputs
Top Co-Authors

Avatar

Bruno M. Silva

Federal University of São Paulo

View shared research outputs
Top Co-Authors

Avatar

Enio Ricardo Vaz Ronque

Universidade Estadual de Londrina

View shared research outputs
Top Co-Authors

Avatar

Daniel Müller Hirai

Universidade Estadual de Londrina

View shared research outputs
Researchain Logo
Decentralizing Knowledge