C. De Bleye
University of Liège
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by C. De Bleye.
Journal of Pharmaceutical and Biomedical Analysis | 2012
C. De Bleye; Pierre-François Chavez; Jérôme Mantanus; R.D. Marini; Ph. Hubert; Eric Rozet; Eric Ziemons
Based on the large number of publications reported over the past five years, near-infrared spectroscopy (NIRS) is more and more considered an attractive and promising analytical tool regarding Process Analytical Technology and Green Chemistry. From the reviewed literature, few of these publications present a thoroughly validated NIRS method even if some guidelines have been published by different groups and regulatory authorities. However, as any analytical method, the validation of NIRS method is a mandatory step at the end of the development in order to give enough guarantees that each of the future results during routine use will be close enough to the true value. Besides the introduction of PAT concepts in the revised document of the European Pharmacopoeia (2.2.40) dealing with near-infrared spectroscopy recently published in Pharmeuropa, it agrees very well with this mandatory step. Indeed, the latter suggests to use similar analytical performance characteristics than those required for any analytical procedure based on acceptance criteria consistent with the intended use of the method. In this context, this review gives a comprehensive and critical overview of the methodologies applied to assess the validity of quantitative NIRS methods used in pharmaceutical applications.
Journal of Pharmaceutical and Biomedical Analysis | 2014
Pierre-Yves Sacre; C. De Bleye; Pierre-François Chavez; Lauranne Netchacovitch; Ph. Hubert; Eric Ziemons
Vibrational spectroscopy (MIR, NIR and Raman) based hyperspectral imaging is one of the most powerful tools to analyze pharmaceutical preparation. Indeed, it combines the advantages of vibrational spectroscopy to imaging techniques and allows therefore the visualization of distribution of compounds or crystallization processes. However, these techniques provide a huge amount of data that must be processed to extract the relevant information. This review presents fundamental concepts of hyperspectral imaging, the basic theory of the most used chemometric tools used to pre-process, process and post-process the generated data. The last part of the present paper focuses on pharmaceutical applications of hyperspectral imaging and highlights the data processing approaches to enable the reader making the best choice among the different tools available.
Analytica Chimica Acta | 2011
Jérôme Mantanus; Eric Rozet; K. Van Butsele; C. De Bleye; Attilio Ceccato; Brigitte Evrard; Ph. Hubert; Eric Ziemons
Using near infrared (NIR) and Raman spectroscopy as PAT tools, 3 critical quality attributes of a silicone-based drug reservoir were studied. First, the Active Pharmaceutical Ingredient (API) homogeneity in the reservoir was evaluated using Raman spectroscopy (mapping): the API distribution within the industrial drug reservoirs was found to be homogeneous while API aggregates were detected in laboratory scale samples manufactured with a non optimal mixing process. Second, the crosslinking process of the reservoirs was monitored at different temperatures with NIR spectroscopy. Conformity tests and Principal Component Analysis (PCA) were performed on the collected data to find out the relation between the temperature and the time necessary to reach the crosslinking endpoints. An agreement was found between the conformity test results and the PCA results. Compared to the conformity test method, PCA had the advantage to discriminate the heating effect from the crosslinking effect occurring together during the monitored process. Therefore the 2 approaches were found to be complementary. Third, based on the HPLC reference method, a NIR model able to quantify the API in the drug reservoir was developed and thoroughly validated. Partial Least Squares (PLS) regression on the calibration set was performed to build prediction models of which the ability to quantify accurately was tested with the external validation set. The 1.2% Root Mean Squared Error of Prediction (RMSEP) of the NIR model indicated the global accuracy of the model. The accuracy profile based on tolerance intervals was used to generate a complete validation report. The 95% tolerance interval calculated on the validation results indicated that each future result will have a relative error below ±5% with a probability of at least 95%. In conclusion, 3 critical quality attributes of silicone-based drug reservoirs were quickly and efficiently evaluated by NIR and Raman spectroscopy.
Journal of Chromatography A | 2010
Cédric Hubert; Sabah Houari; Frédéric Lecomte; Virginie Houbart; C. De Bleye; Marianne Fillet; Géraldine Piel; Eric Rozet; Ph. Hubert
A sensitive and accurate LC/MS method was developed for the monitoring of glucosamine (GLcN) dog plasmatic concentration. In this scope, relatively low plasmatic concentrations of GLcN were expected, ranging from 50 to 1000 ng/mL. Liquid chromatography coupled to simple quadrupole mass spectrometry detection (LC/MS) was selected bringing the selectivity and the sensitivity needed for this application. Additionally, a solid phase extraction (SPE) step was performed to reduce matrix and ion suppression effects. Due to the ionisable character of the compound of interest, a mixed-mode strong cation exchange (Plexa PCX) disposable extraction cartridge (DEC) was selected. The separation was carried out on a Zorbax SB-CN column (5 microm, 4.6mm i.d. x 250 mm), considering hydrophilic interaction liquid chromatography (HILIC). Indeed, the mobile phase was made of methanol and 5mM ammonium hydrogen carbonate buffer at pH 7.5 (95/5, v/v). The detection was led at m/z ratios of 180.0 and 417.0, for GLcN and IS, respectively. Reliability of the results was demonstrated through the validation of the method using an approach based on the accuracy profile allowing managing the risk associated to the use of these methods in routine analysis: it is thus guaranteed that each future result will fall in the +/-30% acceptance limits with a probability of at least 90%. Successful application of the method to a preliminary pharmacokinetic study illustrated the usefulness of the method for pre-clinical studies.
Journal of Pharmaceutical and Biomedical Analysis | 2012
Frédéric Lecomte; Cédric Hubert; Sophie Demarche; C. De Bleye; Amandine Dispas; M. Jost; F. Frankenne; Attilio Ceccato; Eric Rozet; Ph. Hubert
Method validation is essential to ensure that an analytical method is fit for its intended purpose. Additionally, it is advisable to estimate measurement uncertainty in order to allow a correct interpretation of the results generated by analytical methods. Measurement uncertainty can be efficiently estimated during method validation as a top-down approach. However, method validation predictions of the quantitative performances of the assay and estimations of measurement uncertainty may be far away from the real performances obtained during the routine application of this assay. In this work, the predictions of the quantitative performances and measurement uncertainty estimations obtained from a method validation are compared to those obtained during routine applications of a bioanalytical method. For that purpose, a new hydrophilic interaction chromatography (HILIC) method was used. This method was developed for the determination of cidofovir, an antiviral drug, in human plasma. Cidofovir (CDV) is a highly polar molecule presenting three ionizable functions. Therefore, it is an interesting candidate for determination by HILIC mode. CDV is an acyclic cytidine monophosphate analog that has a broad antiviral spectrum and is currently undergoing evaluation in clinical trials as a topical agent for treatment of papillomavirus infections. The analytical conditions were optimized by means of design of experiments approach in order to obtain robust analytical conditions. These ones were absolutely necessary to enable the comparisons mentioned above. After a sample clean-up by means of solid phase extraction, the chromatographic analysis was performed on bare silica stationary phase using a mixture of acetonitrile-ammonium hydrogen carbonate (pH 7.0; 20mM) (72:28, v/v) as mobile phase. This newly developed bioanalytical method was then fully validated according to FDA (Food and Drug Administration) requirements using a total error approach that guaranteed that each future result will fall within acceptance limits of ±30% with a probability of 95% over a concentration range of 92.7-1020ng/mL. A routine application of the cidofovir determination in two pre-clinical trials demonstrated that the prediction made during the pre-study validation was consistent by retrospective analysis of the quality control (QC) samples. Finally, comparison of the measurement uncertainty estimations calculated from the method validation with those obtained from the routine application of the method was performed, stressing that the estimations obtained during method validation underestimated those obtained from routine applications and that the magnitude of this underestimation was function of the cidofovir concentration. Finally, this new HILIC method is reliable, easily applicable to routine analysis and transposable at low cost in other laboratories.
Talanta | 2013
C. De Bleye; Elodie Dumont; Eric Rozet; Pierre-Yves Sacre; Pierre-François Chavez; Lauranne Netchacovitch; Géraldine Piel; Ph. Hubert; Eric Ziemons
A surface enhanced Raman scattering (SERS) method able to quantify 4-aminophenol in a pharmaceutical formulation based on acetaminophen, also called paracetamol, was developed and, for the first time, successfully validated. In this context, silver nanoparticles were synthesized according to the method described by Lee-Meisel and used as SERS substrate. The repeatability of the silver colloid synthesis was tested using different methods to characterize the size and the zeta potential of silver nanoparticles freshly synthesized. To optimize the SERS samples preparation, a design of experiments implicating concentrations of citrate-reduced silver nanoparticles and aggregating agent was performed in order to maximize the Raman signal enhancement. Finally, an approach based on tolerance intervals and accuracy profiles was applied in order to thoroughly validate the method in a range of concentrations comprised from 3 to 15 µg mL(-1) using normalized band intensities. The standard addition method was selected as method calibration. Therefore, measurements were carried out on 4-aminophenol spiked solutions of the pharmaceutical formulation. Despite the well-known stability and reproducibility problems of SERS, the validation was performed using two operators and five batches of nanoparticles, one for each validation day.
Journal of Pharmaceutical and Biomedical Analysis | 2014
C. De Bleye; Pierre-Yves Sacre; Elodie Dumont; Lauranne Netchacovitch; Pierre-François Chavez; Géraldine Piel; Pierre Lebrun; Ph. Hubert; Eric Ziemons
This publication reports, for the first time, the development of a quantitative approach using surface-enhanced Raman chemical imaging (SER-CI). A pharmaceutical model presented as tablets based on paracetamol, which is the most sold drug around the world, was used to develop this approach. 4-Aminophenol is the main impurity of paracetamol and is actively researched in pharmaceutical formulations because of its toxicity. As its concentration is generally very low (<0.1%, w/w), conventional Raman chemical imaging cannot be used. In this context, a SER-CI method was developed to quantify 4-aminophenol assessing a limit of quantification below its limit of specification of 1000 ppm. Citrate-reduced silver nanoparticles were used as SERS substrate and these nanoparticles were functionalized using 1-butanethiol. Different ways to cover the tablets surface by butanethiol-functionalized silver nanoparticles were tested and a homogeneity study of the silver nanoparticles covering was realized. This homogeneity study was performed in order to choose the best way to cover the surface of tablets by silver colloid. Afterwards, the optimization of the SER-CI approach was necessary and different spectral intensity normalizations were tested. Finally, a quantitative approach using SER-CI was developed enabling to quantify 4-aminophenol from 0.025% to 0.2% in paracetamol tablets. This quantitative approach was tested on two different series of tablets using different batches of silver nanoparticles.
International Journal of Pharmaceutics | 2017
Lauranne Netchacovitch; Elodie Dumont; Johan Cailletaud; Justine Thiry; C. De Bleye; Pierre-Yves Sacre; M. Boiret; Brigitte Evrard; Ph. Hubert; Eric Ziemons
The development of a quantitative method determining the crystalline percentage in an amorphous solid dispersion is of great interest in the pharmaceutical field. Indeed, the crystalline Active Pharmaceutical Ingredient transformation into its amorphous state is increasingly used as it enhances the solubility and bioavailability of Biopharmaceutical Classification System class II drugs. One way to produce amorphous solid dispersions is the Hot-Melt Extrusion (HME) process. This study reported the development and the comparison of the analytical performances of two techniques, based on backscattering and transmission Raman spectroscopy, determining the crystalline remaining content in amorphous solid dispersions produced by HME. Principal Component Analysis (PCA) and Partial Least Squares (PLS) regression were performed on preprocessed data and tended towards the same conclusions: for the backscattering Raman results, the use of the DuoScan™ mode improved the PCA and PLS results, due to a larger analyzed sampling volume. For the transmission Raman results, the determination of low crystalline percentages was possible and the best regression model was obtained using this technique. Indeed, the latter acquired spectra through the whole sample volume, in contrast with the previous surface analyses performed using the backscattering mode. This study consequently highlighted the importance of the analyzed sampling volume.
Journal of Pharmaceutical and Biomedical Analysis | 2015
Lauranne Netchacovitch; Justine Thiry; C. De Bleye; Pierre-François Chavez; Fabrice Krier; Pierre-Yves Sacre; Brigitte Evrard; Ph. Hubert; Eric Ziemons
Since the last decade, more and more Active Pharmaceutical Ingredient (API) candidates have poor water solubility inducing low bioavailability. These molecules belong to the Biopharmaceutical Classification System (BCS) classes II and IV. Thanks to Hot-Melt Extrusion (HME), it is possible to incorporate these candidates in pharmaceutical solid forms. Indeed, HME increases the solubility and the bioavailability of these drugs by encompassing them in a polymeric carrier and by forming solid dispersions. Moreover, in 2004, the FDAs guidance initiative promoted the usefulness of Process Analytical Technology (PAT) tools when developing a manufacturing process. Indeed, the main objective when developing a new pharmaceutical process is the product quality throughout the production chain. The trend is to follow this parameter in real-time in order to react immediately when there is a bias. Vibrational spectroscopic techniques, NIR and Raman, are useful to analyze processes in-line. Moreover, off-line Raman microspectroscopy is more and more used when developing new pharmaceutical processes or when analyzing optimized ones by combining the advantages of Raman spectroscopy and imaging. It is an interesting tool for homogeneity and spatial distribution studies. This review treats about spectroscopic techniques analyzing a HME process, as well off-line as in-line, presenting their advantages and their complementarities.
Analytica Chimica Acta | 2015
C. De Bleye; Elodie Dumont; Cédric Hubert; Pierre-Yves Sacre; Lauranne Netchacovitch; Pierre-François Chavez; Ph. Hubert; Eric Ziemons
Bisphenol A (BPA) is well known for its use in plastic manufacture and thermal paper production despite its risk of health toxicity as an endocrine disruptor in humans. Since the publication of new legislation regarding the use of BPA, manufacturers have begun to replace BPA with other phenolic molecules such as bisphenol F (BPF) and bisphenol B (BPB), but there are no guarantees regarding the health safety of these compounds at this time. In this context, a very simple, cheap and fast surface-enhanced Raman scattering (SERS) method was developed for the sensitive detection of these molecules in spiked tap water solutions. Silver nanoparticles were used as SERS substrates. An original strategy was employed to circumvent the issue of the affinity of bisphenols for metallic surfaces and the silver nanoparticles surface was functionalized using pyridine in order to improve again the sensitivity of the detection. Semi-quantitative detections were performed in tap water solutions at a concentrations range from 0.25 to 20 μg L(-1) for BPA and BPB and from 5 to 100 μg L(-1) for BPF. Moreover, a feasibility study for performing a multiplex-SERS detection of these molecules was also performed before successfully implementing the developed SERS method on real samples.