Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Caroline Scemama is active.

Publication


Featured researches published by Caroline Scemama.


Journal of Orthopaedic Research | 2015

Validation of a computer-assisted method for measurement of radiographic wear in total hip arthroplasty using all polyethylene cemented acetabular components

Jean Langlois; Amine Zaoui; Caroline Scemama; John M. Martell; Charles R. Bragdon; Moussa Hamadouche

Although cemented all polyethylene (PE) cups have been routinely used in total hip arthroplasty for decades, no computer‐assisted method for measurement of radiographic wear has ever been specifically validated for these implants. Using a validated hip phantom model, AP plain hip radiographs were obtained consecutively for eight simulated wear positions. A version of Martells Hip Analysis Suite software dedicated to all polyethylene sockets was used by three different examiners of varied experience. Bias (mean, standard deviation and 95% confidence interval limit), repeatability (standard deviation and 95% limit) and reproducibility (standard deviation and 95% limit) for two‐dimensional wear measurements were assessed, as recommended by the current ASTM guidelines. Using this protocol, the dedicated software showed an overall mean bias of 0.089 ± 0.060 mm (mean ± SD), and 0.118 mm for 95% CI limit. Repeatability (intra examiner) standard deviation and 95% limit were respectively 0.106 mm and 0.292 mm. Reproducibility (inter examiner) standard deviation and 95% limit were respectively 0.112 mm and 0.308 mm. Martell Hip Analysis for all PE cemented cups is a reliable and low‐cost instrument in the assessment of wear, despite being less precise than its original version dedicated to cementless components.


International Orthopaedics | 2015

Length of clinically proven cemented hip stems: State of the art or subject to improvement?

Moussa Hamadouche; Alexander Jahnke; Caroline Scemama; Bernd Ishaque; Markus Rickert; Luc Kerboull; Eike Jakubowitz


International Orthopaedics | 2017

Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial

Caroline Scemama; Philippe Anract; Valérie Dumaine; Antoine Babinet; Jean Pierre Courpied; Moussa Hamadouche


International Orthopaedics | 2016

Anterior approach for total hip arthroplasty conversion of hip fusion

Caroline Scemama; Vincent Lestrat; Benoit Combourieu; Thierry Judet


International Orthopaedics | 2015

Minimum five-year wear rate of metal-on-highly cross-linked polyethylene in primary total hip arthroplasty

Caroline Scemama; Claudio Dora; Jean Langlois; Moussa Hamadouche


International Orthopaedics | 2014

Osseointegration of polyethylene implants coated with titanium and biomimetically or electrochemically deposited hydroxyapatite in a rabbit model

Caroline Scemama; Bertrand David; Morad Bensidhoum; Moussa Hamadouche


Orthopaedic Proceedings | 2018

A RANDOMIZED CONTROLLED TRIAL COMPARISON OF DELTA CERAMIC VERSUS METAL AGAINST CONVENTIONAL POLYETHYLENE IN TOTAL HIP ARTHROPLASTY

Amine Zaoui; Jean Langlois; S El Hage; Caroline Scemama; Jean-Pierre Courpied; Moussa Hamadouche


Revue de Chirurgie Orthopédique et Traumatologique | 2016

Le polyéthylène hautement réticulé de deuxième génération dopé à la vitamine E versus conventionnel dans l’arthroplastie totale de hanche. Étude prospective randomisée à 4 ans minimum de recul

Caroline Scemama; Philippe Anract; Valérie Dumaine; Antoine Babinet; Jean-Pierre Courpied; Moussa Hamadouche


Revue de Chirurgie Orthopédique et Traumatologique | 2014

Imagerie in vivo de l’inflammation aux particules d’usure de polyéthylène dans un modèle d’ostéolyse murin

Amine Zaoui; Jean Langlois; Christophe Nich; Morad Bensidhoum; Delphine Logeart-Avramouglou; Caroline Scemama; Hervé Petite; Moussa Hamadouche


Revue de Chirurgie Orthopédique et Traumatologique | 2014

Évaluation à 5 ans minimum de recul d’un polyéthylène hautement réticulé de première génération dans une cupule métal-back

Caroline Scemama; Moussa Hamadouche; Claudio Dora

Collaboration


Dive into the Caroline Scemama's collaboration.

Top Co-Authors

Avatar

Moussa Hamadouche

Paris Descartes University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Amine Zaoui

Centre national de la recherche scientifique

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Philippe Anract

Paris Descartes University

View shared research outputs
Top Co-Authors

Avatar

Hervé Petite

Centre national de la recherche scientifique

View shared research outputs
Researchain Logo
Decentralizing Knowledge