Christi Kolarcik
University of Pittsburgh
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Christi Kolarcik.
Journal of Neural Engineering | 2015
Christi Kolarcik; Kasey Catt; Erika Rost; Ingrid N Albrecht; Dennis Bourbeau; Zhanhong Du; Takashi D.Y. Kozai; Xiliang Luo; Douglas J. Weber; X. Tracy Cui
OBJECTIVE The dorsal root ganglion is an attractive target for implanting neural electrode arrays that restore sensory function or provide therapy via stimulation. However, penetrating microelectrodes designed for these applications are small and deliver low currents. For long-term performance of microstimulation devices, novel coating materials are needed in part to decrease impedance values at the electrode-tissue interface and to increase charge storage capacity. APPROACH Conductive polymer poly(3,4-ethylenedioxythiophene) (PEDOT) and multi-wall carbon nanotubes (CNTs) were coated on the electrode surface and doped with the anti-inflammatory drug, dexamethasone. Electrode characteristics and the tissue reaction around neural electrodes as a result of stimulation, coating and drug release were characterized. Hematoxylin and eosin staining along with antibodies recognizing Iba1 (microglia/macrophages), NF200 (neuronal axons), NeuN (neurons), vimentin (fibroblasts), caspase-3 (cell death) and L1 (neural cell adhesion molecule) were used. Quantitative image analyses were performed using MATLAB. MAIN RESULTS Our results indicate that coated microelectrodes have lower in vitro and in vivo impedance values. Significantly less neuronal death/damage was observed with coated electrodes as compared to non-coated controls. The inflammatory response with the PEDOT/CNT-coated electrodes was also reduced. SIGNIFICANCE This study is the first to report on the utility of these coatings in stimulation applications. Our results indicate PEDOT/CNT coatings may be valuable additions to implantable electrodes used as therapeutic modalities.
Acta Biomaterialia | 2012
Christi Kolarcik; Dennis Bourbeau; Erdrin Azemi; E. Rost; Li Zhang; Carl F. Lagenaur; Douglas J. Weber; Xinyan Tracy Cui
The spinal cord (SC) and dorsal root ganglion (DRG) are target implantation regions for neural prosthetics, but the tissue-electrode interface in these regions is not well-studied. To improve understanding of these locations, the tissue reactions around implanted electrodes were characterized. L1, an adhesion molecule shown to maintain neuronal density and reduce gliosis in brain tissue, was then evaluated in SC and DRG implants. Following L1 immobilization onto neural electrodes, the bioactivities of the coatings were verified in vitro using neuron, astrocyte and microglia cultures. Non-modified and L1-coated electrodes were implanted into adult rats for 1 or 4 weeks. Hematoxylin and eosin staining along with cell-type specific antibodies were used to characterize the tissue response. In the SC and DRG, cells aggregated at the electrode-tissue interface. Microglia staining was more intense around the implant site and decreased with distance from the interface. Neurofilament staining in both locations decreased or was absent around the implant, compared with surrounding tissue. With L1, neurofilament staining was significantly increased while neuronal cell death decreased. These results indicate that L1-modified electrodes may result in an improved chronic neural interface and will be evaluated in recording and stimulation studies.
Molecular Diagnosis & Therapy | 2006
Christi Kolarcik; Robert Bowser
Motor neuron diseases (MNDs) and, in particular, amyotrophic lateral sclerosis (ALS), are a heterogeneous group of neurologic disorders characterized by the progressive loss of motor function. In ALS, a selective and relentless degeneration of both upper and lower motor neurons occurs, culminating in mortality typically within 5 years of symptom onset. However, survival rates vary among individual patients and can be from a few months to >10 years from diagnosis. Inadequacies in disease detection and treatment, along with a lack of diagnostic and prognostic tools, have prompted many to turn to proteomics-based biomarker discovery efforts. Proteomics refers to the study of the proteins expressed by a genome at a particular time, and the proteome can respond to and reflect the status of an organism, including health and disease states. Although an emerging field, proteomic applications promise to uncover biomarkers critical for differentiating patients with ALS and other MNDs from healthy individuals and from patients affected by other diseases. Ideally, these studies will also provide mechanistic information to facilitate identification of new drug targets for subsequent therapeutic development.In addition to proper experimental design, standard operating procedures for sample acquisition, preprocessing, and storage must be developed. Biological samples typically analyzed in proteomic studies of neurologic diseases include both plasma and cerebrospinal fluid (CSF). Recent studies have identified individual proteins and/or protein panels from blood plasma and CSF that represent putative biomarkers for ALS, although many of these proteins are not unique to this disease. Continued investigations are required to validate these initial findings and to further pursue the role of these proteins as diagnostic biomarkers or surrogate markers of disease progression. Protein biomarkers specific to ALS will additionally function to evaluate drug efficacy in clinical trials and to identify novel targets for drug design. It is hoped that proteomic technologies will soon integrate the basic biology of ALS with mechanistic disease information to achieve success in the clinical setting.
Acta Biomaterialia | 2017
Zhanhong Jeff Du; Christi Kolarcik; Takashi D.Y. Kozai; Silvia Luebben; Shawn A. Sapp; Xin Sally Zheng; James A. Nabity; X. Tracy Cui
Chronically implanted neural multi-electrode arrays (MEA) are an essential technology for recording electrical signals from neurons and/or modulating neural activity through stimulation. However, current MEAs, regardless of the type, elicit an inflammatory response that ultimately leads to device failure. Traditionally, rigid materials like tungsten and silicon have been employed to interface with the relatively soft neural tissue. The large stiffness mismatch is thought to exacerbate the inflammatory response. In order to minimize the disparity between the device and the brain, we fabricated novel ultrasoft electrodes consisting of elastomers and conducting polymers with mechanical properties much more similar to those of brain tissue than previous neural implants. In this study, these ultrasoft microelectrodes were inserted and released using a stainless steel shuttle with polyethyleneglycol (PEG) glue. The implanted microwires showed functionality in acute neural stimulation. When implanted for 1 or 8weeks, the novel soft implants demonstrated significantly reduced inflammatory tissue response at week 8 compared to tungsten wires of similar dimension and surface chemistry. Furthermore, a higher degree of cell body distortion was found next to the tungsten implants compared to the polymer implants. Our results support the use of these novel ultrasoft electrodes for long term neural implants. STATEMENT OF SIGNIFICANCE One critical challenge to the translation of neural recording/stimulation electrode technology to clinically viable devices for brain computer interface (BCI) or deep brain stimulation (DBS) applications is the chronic degradation of device performance due to the inflammatory tissue reaction. While many hypothesize that soft and flexible devices elicit reduced inflammatory tissue responses, there has yet to be a rigorous comparison between soft and stiff implants. We have developed an ultra-soft microelectrode with Youngs modulus lower than 1MPa, closely mimicking the brain tissue modulus. Here, we present a rigorous histological comparison of this novel ultrasoft electrode and conventional stiff electrode with the same size, shape and surface chemistry, implanted in rat brains for 1-week and 8-weeks. Significant improvement was observed for ultrasoft electrodes, including inflammatory tissue reaction, electrode-tissue integration as well as mechanical disturbance to nearby neurons. A full spectrum of new techniques were developed in this study, from insertion shuttle to in situ sectioning of the microelectrode to automated cell shape analysis, all of which should contribute new methods to the field. Finally, we showed the electrical functionality of the ultrasoft electrode, demonstrating the potential of flexible neural implant devices for future research and clinical use.
Soft Matter | 2015
Christi Kolarcik; Silvia Luebben; Shawn A. Sapp; Jenna Hanner; Takashi D.Y. Kozai; Emily Chang; James A. Nabity; Shawn T. Nabity; Carl F. Lagenaur; X. Tracy Cui
The FASEB Journal | 2014
Christi Kolarcik; Andrew Lesniak; Carlos Castro; Anthony J. Demetris; Robert A. Gaunt; Xinyan Tracy Cui
The FASEB Journal | 2014
Christi Kolarcik; Jenna Hanner; Zhanhong Du; Shawn A. Sapp; Silvia Luebben; Xinyan Tracy Cui
The FASEB Journal | 2010
Christi Kolarcik; Robert Bowser
The FASEB Journal | 2010
Christi Kolarcik; Jeban Ganesalingam; Samuel W. Darko; Jiyan An; David Lacomis; Robert Bowser
The FASEB Journal | 2009
Christi Kolarcik; Robert Bowser