Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where D. Corsini is active.

Publication


Featured researches published by D. Corsini.


Journal of Instrumentation | 2017

Measuring the electron neutrino mass with improved sensitivity: the HOLMES experiment

A. Giachero; Bradley K. Alpert; D.T. Becker; D. Bennett; M. Biasotti; C. Brofferio; V. Ceriale; G. Ceruti; D. Corsini; Peter K. Day; M. De Gerone; R. Dressler; M. Faverzani; E. Ferri; J. W. Fowler; E. Fumagalli; G. Gallucci; J. Gard; F. Gatti; J. Hays-Wehle; S. Heinitz; G. C. Hilton; U. Köster; M. Lusignoli; J. A. B. Mates; S. Nisi; A. Nucciotti; A. Orlando; L. Parodi; G. Pessina

HOLMES is a new experiment aiming at directly measuring the neutrino mass with a sensitivity below 2 eV. HOLMES will perform a calorimetric measurement of the energy released in the decay of


Proceedings of SPIE | 2016

The Cryogenic Anti-Coincidence detector for ATHENA X-IFU: pulse analysis of the AC-S7 single pixel prototype

Matteo D'Andrea; A. Argan; Simone Lotti; C. Macculi; Luigi Piro; M. Biasotti; D. Corsini; F. Gatti; G. Torrioli

^{163}


Proceedings of SPIE | 2016

The Cryogenic AntiCoincidence detector for ATHENA X-IFU: A program overview

C. Macculi; A. Argan; Matteo D'Andrea; Simone Lotti; M. Laurenza; Luigi Piro; M. Biasotti; D. Corsini; F. Gatti; G. Torrioli; M. Fiorini; S. Molendi; M. Uslenghi; T. Mineo; A. Bulgarelli; V. Fioretti; E. Cavazzuti

Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with spectrometers. This measurement was proposed in 1982 by A. De Rujula and M. Lusignoli, but only recently the detector technological progress has allowed to design a sensitive experiment. HOLMES will deploy a large array of low temperature microcalorimeters with implanted


Proceedings of SPIE | 2016

The new cryogenic silicon monolithic micro-bridged Anticoincidence detector for the X-IFU of ATHENA

M. Biasotti; D. Corsini; M. De Gerone; F. Gatti; C. Macculi; Matteo D'Andrea; Luigi Piro

^{163}


Proceedings of SPIE | 2014

The Cryogenic AntiCoincidence detector for ATHENA: the progress towards the final pixel design

C. Macculi; Luigi Piro; Donatella Cea; L. Colasanti; Simone Lotti; L. Natalucci; F. Gatti; D. Bagliani; M. Biasotti; D. Corsini; G. Pizzigoni; G. Torrioli; Marco Barbera; Teresa Mineo; Emanuele Perinati

Ho nuclei. HOLMES, besides being an important step forward in the direct neutrino mass measurement with a calorimetric approach, will also establish the potential of this approach to extend the sensitivity down to 0.1 eV and lower. In its final configuration HOLMES will collect about


Journal of Physics: Conference Series | 2014

Large Area ?-thermal Phonon TES Detector Mediated by the quasi-particle Diffusion Signal for Space Application

G. Pizzigoni; D Bagliani; M. Biasotti; D. Corsini; M De Gerone; F. Gatti; C. Macculi; Luigi Piro

3\cdot 10^{13}


Journal of Physics: Conference Series | 2018

Direct neutrino mass measurement by the HOLMES experiment

A. Nucciotti; Bradley K. Alpert; M. Balata; D. Becker; D. A. Bennett; A. Bevilacqua; M. Biasotti; V. Ceriale; G. Ceruti; D. Corsini; M De Gerone; R. Dressler; M. Faverzani; E. Ferri; J. W. Fowler; J. Gard; F. Gatti; A. Giachero; J. Hays-Wehle; S. Heinitz; G. C. Hilton; U. Köster; M. Lusignoli; J. A. B. Mates; S. Nisi; A. Orlando; L. Parodi; G. Pessina; A. Puiu; S. Ragazzi

decays with 1000 detectors characterized by an instrumental energy resolution of the order of few eV and a time resolution of few microseconds. To embed the


Journal of Low Temperature Physics | 2018

Status of the HOLMES Experiment to Directly Measure the Neutrino Mass

A. Nucciotti; Bradley K. Alpert; M. Balata; D. Becker; D. A. Bennett; A. Bevilacqua; M. Biasotti; V. Ceriale; G. Ceruti; D. Corsini; M. De Gerone; R. Dressler; M. Faverzani; E. Ferri; J. W. Fowler; G. Gallucci; J. Gard; F. Gatti; A. Giachero; J. Hays-Wehle; S. Heinitz; G. C. Hilton; U. Köster; M. Lusignoli; J. A. B. Mates; S. Nisi; A. Orlando; L. Parodi; G. Pessina; A. Puiu

^{163}


Journal of Low Temperature Physics | 2018

The Cryogenic AntiCoincidence Detector for ATHENA X-IFU: Improvement of the Test Setup Toward the Demonstration Model

M. D’Andrea; C. Macculi; A. Argan; Simone Lotti; Gabriele Minervini; Luigi Piro; M. Biasotti; D. Corsini; F. Gatti; G. Torrioli; A. Volpe

Ho into the gold absorbers a custom mass separator ion implanter is being developed. The detectors used for the HOLMES experiment will be Mo/Cu bilayers TESs (Transition Edge Sensors) on SiN


Proceedings of SPIE | 2016

The mechanical and EM simulations of the CryoAC for the ATHENA X-IFU

D. Corsini; M. Biasotti; F. Gatti; M. De Gerone; C. Rossi; Luigi Piro; C. Macculi

_x

Collaboration


Dive into the D. Corsini's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

G. Torrioli

Istituto Nazionale di Fisica Nucleare

View shared research outputs
Researchain Logo
Decentralizing Knowledge