Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Denise M. Irvine is active.

Publication


Featured researches published by Denise M. Irvine.


Medical Physics | 2013

Octavius 4D characterization for flattened and flattening filter free rotational deliveries

Conor K. McGarry; Barry F. O'Connell; Mark W. D. Grattan; Christina E. Agnew; Denise M. Irvine; A.R. Hounsell

PURPOSE In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans. METHODS The response of the detectors to field size, dose linearity, and dose rate were assessed for 6 MV FF beams and also 6 and 10 MV FFF beams. Dosimetric and mechanical accuracy of the detector array within the Octavius 4D rotational phantom was evaluated against measurements made using semiflex and pinpoint ionization chambers, and radiochromic film. Verification FF and FFF RapidArc plans were assessed using a gamma function with 3%∕3 mm tolerances and 2%∕2 mm tolerances and further analysis of these plans was undertaken using film and a second detector array with higher spatial resolution. RESULTS A warm-up dose of >6 Gy was required for detector stability. Dose-rate measurements were stable across a range from 0.26 to 15 Gy∕min and dose response was linear, although the device overestimated small doses compared with pinpoint ionization chamber measurements. Output factors agreed with ionization chamber measurements to within 0.6% for square fields of side between 3 and 25 cm and within 1.2% for 2 × 2 cm(2) fields. The Octavius 4D phantom was found to be consistent with measurements made with radiochromic film, where the gantry angle was found to be within 0.4° of that expected during rotational deliveries. RapidArc FF and FFF beams were found to have an accuracy of >97.9% and >90% of pixels passing 3%∕3 mm and 2%∕2 mm, respectively. Detector spatial resolution was observed to be a factor in determining the accurate delivery of each plan, particularly at steep dose gradients. This was confirmed using data from a second detector array with higher spatial resolution and with radiochromic film. CONCLUSIONS The Octavius 4D phantom with associated Octavius detector 729 ionization chamber array is a dosimetrically and mechanically stable device for pretreatment verification of FF and FFF RapidArc treatments. Further improvements may be possible through use of a detector array with higher spatial resolution (detector size and∕or detector spacing).


Journal of Applied Clinical Medical Physics | 2014

Correlation of phantom-based and log file patient-specific QA with complexity scores for VMAT

Christina E. Agnew; Denise M. Irvine; Conor K. McGarry

The motivation for this study was to reduce physics workload relating to patient‐specific quality assurance (QA). VMAT plan delivery accuracy was determined from analysis of pre‐ and on‐treatment trajectory log files and phantom‐based ionization chamber array measurements. The correlation in this combination of measurements for patient‐specific QA was investigated. The relationship between delivery errors and plan complexity was investigated as a potential method to further reduce patient‐specific QA workload. Thirty VMAT plans from three treatment sites — prostate only, prostate and pelvic node (PPN), and head and neck (H&N) — were retrospectively analyzed in this work. The 2D fluence delivery reconstructed from pretreatment and on‐treatment trajectory log files was compared with the planned fluence using gamma analysis. Pretreatment dose delivery verification was also carried out using gamma analysis of ionization chamber array measurements compared with calculated doses. Pearson correlations were used to explore any relationship between trajectory log file (pretreatment and on‐treatment) and ionization chamber array gamma results (pretreatment). Plan complexity was assessed using the MU/ arc and the modulation complexity score (MCS), with Pearson correlations used to examine any relationships between complexity metrics and plan delivery accuracy. Trajectory log files were also used to further explore the accuracy of MLC and gantry positions. Pretreatment 1%/1 mm gamma passing rates for trajectory log file analysis were 99.1% (98.7%–99.2%), 99.3% (99.1%–99.5%), and 98.4% (97.3%–98.8%) (median (IQR)) for prostate, PPN, and H&N, respectively, and were significantly correlated to on‐treatment trajectory log file gamma results (R=0.989,p<0.001). Pretreatment ionization chamber array (2%/2 mm) gamma results were also significantly correlated with on‐treatment trajectory log file gamma results (R=0.623,p<0.001). Furthermore, all gamma results displayed a significant correlation with MCS (R>0.57,p<0.001), but not with MU/arc. Average MLC position and gantry angle errors were 0.001±0.002mm and 0.025°±0.008° over all treatment sites and were not found to affect delivery accuracy. However, variability in MLC speed was found to be directly related to MLC position accuracy. The accuracy of VMAT plan delivery assessed using pretreatment trajectory log file fluence delivery and ionization chamber array measurements were strongly correlated with on‐treatment trajectory log file fluence delivery. The strong correlation between trajectory log file and phantom‐based gamma results demonstrates potential to reduce our current patient‐specific QA. Additionally, insight into MLC and gantry position accuracy through trajectory log file analysis and the strong correlation between gamma analysis results and the MCS could also provide further methodologies to both optimize the VMAT planning and QA process. PACS number: 87.53.Bn, 87.55.Kh, 87.55.Qr


Practical radiation oncology | 2014

Improvement in clinical step and shoot intensity modulated radiation therapy delivery accuracy on an integrated linear accelerator control system.

Christina E. Agnew; Denise M. Irvine; A.R. Hounsell; Conor K. McGarry

PURPOSE The dose delivery accuracy of 30 clinical step and shoot intensity modulated radiation therapy plans was investigated using the single integrated multileaf collimator controller of the Varian Truebeam linear accelerator (linac) (Varian Medical Systems, Palo Alto, CA) and compared with the dose delivery accuracy on a previous generation Varian 2100CD C-Series linac. METHODS AND MATERIALS Ten prostate, 10 prostate and pelvic node, and 10 head-and-neck cases were investigated in this study. Dose delivery accuracy on each linac was assessed using Farmer ionization chamber point dose measurements, 2-dimensional planar ionization chamber array measurements, and the corresponding Varian dynamic log files. Absolute point dose measurements, fluence delivery accuracy, leaf position accuracy, and the overshoot effect were assessed for each plan. RESULTS Absolute point dose delivery accuracy increased by 1.5% on the Truebeam compared with the 2100CD linac. No improvement in fluence delivery accuracy between the linacs, at a gamma criterion of 3%/3 mm was measured using the 2-dimensional ionization chamber array, with median (interquartile range) gamma passing rates of 98.99% (97.70%-99.72%) and 99.28% (98.26%-99.75%) for the Truebeam and 2100CD linacs, respectively. Varian log files also showed no improvement in fluence delivery between the linacs at 3%/3 mm, with median gamma passing rates of 99.97% (99.93%-99.99%) and 99.98% (99.94%-100%) for the Truebeam and 2100CD linacs, respectively. However, log files revealed improved leaf position accuracy and fluence delivery at 1%/1 mm criterion on the Truebeam (99.87%; 99.78%-99.94%) compared with the 2100CD linac (97.87%; 91.93%-99.49%). The overshoot effect, characterized on the 2100CD linac, was not observed on the Truebeam. CONCLUSIONS The integrated multileaf collimator controller on the Varian Truebeam improves clinical treatment delivery accuracy of step and shoot intensity modulated radiation therapy fields compared with delivery on a Varian C-series linac.


British Journal of Radiology | 2015

Optimizing geometric accuracy of four dimensional CT scans acquired using the wall and couch mounted Varian Real-Time Position Management camera systems

B.F. O'Connell; Denise M. Irvine; Aidan J Cole; G.G. Hanna; Conor K. McGarry

OBJECTIVE The aim of this study was to identify sources of anatomical misrepresentation owing to the location of camera mounting, tumour motion velocity and image processing artefacts in order to optimize the four-dimensional CT (4DCT) scan protocol and improve geometrical-temporal accuracy. METHODS A phantom with an imaging insert was driven with a sinusoidal superior-inferior motion of varying amplitude and period for 4DCT scanning. The length of a high-density cube within the insert was measured using treatment planning software to determine the accuracy of its spatial representation. Scan parameters were varied, including the tube rotation period and the cine time between reconstructed images. A CT image quality phantom was used to measure various image quality signatures under the scan parameters tested. RESULTS No significant difference in spatial accuracy was found for 4DCT scans carried out using the wall- or couch-mounted camera for sinusoidal target motion. Greater spatial accuracy was found for 4DCT scans carried out using a tube rotation speed of 0.5 s rather than 1.0 s. The reduction in image quality when using a faster rotation speed was not enough to require an increase in patient dose. CONCLUSION The 4DCT accuracy may be increased by optimizing scan parameters, including choosing faster tube rotation speeds. Peak misidentification in the recorded breathing trace may lead to spatial artefacts, and this risk can be reduced by using a couch-mounted infrared camera. ADVANCES IN KNOWLEDGE This study explicitly shows that 4DCT scan accuracy is improved by scanning with a faster CT tube rotation speed.


Journal of Clinical Oncology | 2016

Single institution, retrospective comparison of toxicity and outcome for static 5-field IMRT versus VMAT in the delivery of prostate and pelvic nodal irradiation in high-risk prostate cancer.

Philip Turner; Suneil Jain; Gemma Corey; Darren M. Mitchell; Karen Tumelty; Denise M. Irvine; J. Harney; Fionnuala Houghton; J. McAleese; Lin Shum; David P. Stewart; Joe M. O'Sullivan

147 Background: There is emerging evidence for the role of pelvic nodal irradiation in high-risk prostate cancer. We have assessed the toxicity rates and outcomes with 2 different radiotherapy techniques. Methods: The baseline disease metrics, toxicity and outcome data for men treated at our institution with prostate and pelvic nodal irradiation during a 2 year period were retrospectively collected. The radiotherapy technique, either 5-field IMRT or VMAT was recorded along with a single dose-level to indicate normal tissue exposure (V50 to bowel and rectum, that is the percentage of total organ receiving ≥ 50Gy). Results: 67 men with a median age of 64 years were identified; 83.6% were Gleason ≥ 8, 82.1% were ≥ T3a, 50.7% were N1, 4.5% were M1a/M1b. All had neoadjuvant and concurrent hormone therapy. All received 74Gy to prostate; 70.1% received 60Gy to pelvic nodes, 28.4% received 55Gy to pelvic nodes (1 patient received 56Gy). 55.2% were treated with static IMRT and 44.8% with VMAT with no significant d...


Radiation Oncology | 2016

Class solutions for SABR-VMAT for high-risk prostate cancer with and without elective nodal irradiation

Sarah O.S. Osman; Prakash Jeevanandam; Nithya Kanakavelu; Denise M. Irvine; Ciara Lyons; Suneil Jain; A.R. Hounsell; Conor K. McGarry


Physica Medica | 2018

Patient-specific quality control for stereotactic cranial radiosurgery

Candice McCallum; Prakash Jeevanandam; Denise M. Irvine; Conor K. McGarry


Medical Physics | 2018

Improvement of off‐axis SABR plan verification results by using adapted dose reconstruction algorithms for the Octavius 4D system

Prakash Jeevanandam; Christina E. Agnew; Denise M. Irvine; Conor K. McGarry


Ejso | 2017

Impact and practical aspects of rectal spacer insertion for prostate stereotactic radiotherapy – First UK experience

Ciaran Fairmichael; Raymond King; Sara Os. Osman; Denise M. Irvine; A.R. Hounsell; Darren M. Mitchell; Conor K. McGarry; Suneil Jain


Physica Medica | 2016

Characterisation of a MatriXX Evolution ionisation chamber array for stereotactic body radiotherapy (SBRT) plan validation

Robert Lally; Denise M. Irvine; Conor K. McGarry

Collaboration


Dive into the Denise M. Irvine's collaboration.

Top Co-Authors

Avatar

Conor K. McGarry

Belfast Health and Social Care Trust

View shared research outputs
Top Co-Authors

Avatar

A.R. Hounsell

Belfast Health and Social Care Trust

View shared research outputs
Top Co-Authors

Avatar

Christina E. Agnew

Belfast Health and Social Care Trust

View shared research outputs
Top Co-Authors

Avatar

Suneil Jain

Queen's University Belfast

View shared research outputs
Top Co-Authors

Avatar

Prakash Jeevanandam

Belfast Health and Social Care Trust

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Nithya Kanakavelu

Belfast Health and Social Care Trust

View shared research outputs
Top Co-Authors

Avatar

Sarah O.S. Osman

Queen's University Belfast

View shared research outputs
Top Co-Authors

Avatar

Aidan J Cole

Queen's University Belfast

View shared research outputs
Top Co-Authors

Avatar