Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Edward R. Flynn is active.

Publication


Featured researches published by Edward R. Flynn.


Brain Topography | 2002

Conductivities of three-layer live human skull

Akhtari M; Bryant Hc; Mamelak An; Edward R. Flynn; L. Heller; Jerry J. Shih; M. Mandelkern; A. Matlachov; Ranken Dm; E.D. Best; DiMauro Ma; Lee Rr; Sutherling Ww

Electrical conductivities of compact, spongiosum, and bulk layers of the live human skull were determined at varying frequencies and electric fields at room temperature using the four-electrode method. Current, at higher densities that occur in human cranium, was applied and withdrawn over the top and bottom surfaces of each sample and potential drop across different layers was measured. We used a model that considers variations in skull thicknesses to determine the conductivity of the tri-layer skull and its individual anatomical structures. The results indicate that the conductivities of the spongiform (16.2-41.1 milliS/m), the top compact (5.4-7.2 milliS/m) and lower compact (2.8-10.2 milliS/m) layers of the skull have significantly different and inhomogeneous conductivities. The conductivities of the skull layers are frequency dependent in the 10-90 Hz region and are non-ohmic in the 0.45-2.07 A/m2 region. These current densities are much higher than those occurring in human brain.


Breast Cancer Research | 2011

Detection of breast cancer cells using targeted magnetic nanoparticles and ultra-sensitive magnetic field sensors

Helen J. Hathaway; Kimberly S. Butler; Natalie L. Adolphi; Debbie M. Lovato; Robert Belfon; Danielle L. Fegan; Todd C. Monson; Jason E. Trujillo; Trace E. Tessier; Howard C. Bryant; Dale L. Huber; Richard S. Larson; Edward R. Flynn

IntroductionBreast cancer detection using mammography has improved clinical outcomes for many women, because mammography can detect very small (5 mm) tumors early in the course of the disease. However, mammography fails to detect 10 - 25% of tumors, and the results do not distinguish benign and malignant tumors. Reducing the false positive rate, even by a modest 10%, while improving the sensitivity, will lead to improved screening, and is a desirable and attainable goal. The emerging application of magnetic relaxometry, in particular using superconducting quantum interference device (SQUID) sensors, is fast and potentially more specific than mammography because it is designed to detect tumor-targeted iron oxide magnetic nanoparticles. Furthermore, magnetic relaxometry is theoretically more specific than MRI detection, because only target-bound nanoparticles are detected. Our group is developing antibody-conjugated magnetic nanoparticles targeted to breast cancer cells that can be detected using magnetic relaxometry.MethodsTo accomplish this, we identified a series of breast cancer cell lines expressing varying levels of the plasma membrane-expressed human epidermal growth factor-like receptor 2 (Her2) by flow cytometry. Anti-Her2 antibody was then conjugated to superparamagnetic iron oxide nanoparticles using the carbodiimide method. Labeled nanoparticles were incubated with breast cancer cell lines and visualized by confocal microscopy, Prussian blue histochemistry, and magnetic relaxometry.ResultsWe demonstrated a time- and antigen concentration-dependent increase in the number of antibody-conjugated nanoparticles bound to cells. Next, anti Her2-conjugated nanoparticles injected into highly Her2-expressing tumor xenograft explants yielded a significantly higher SQUID relaxometry signal relative to unconjugated nanoparticles. Finally, labeled cells introduced into breast phantoms were measured by magnetic relaxometry, and as few as 1 million labeled cells were detected at a distance of 4.5 cm using our early prototype system.ConclusionsThese results suggest that the antibody-conjugated magnetic nanoparticles are promising reagents to apply to in vivo breast tumor cell detection, and that SQUID-detected magnetic relaxometry is a viable, rapid, and highly sensitive method for in vitro nanoparticle development and eventual in vivo tumor detection.


Contrast Media & Molecular Imaging | 2012

Imaging of Her2-targeted magnetic nanoparticles for breast cancer detection: comparison of SQUID-detected magnetic relaxometry and MRI.

Natalie L. Adolphi; Kimberly S. Butler; Debbie M. Lovato; Trace E. Tessier; Jason E. Trujillo; Helen J. Hathaway; Danielle L. Fegan; Todd C. Monson; Tyler E. Stevens; Dale L. Huber; Jaivijay Ramu; Michelle L. Milne; Stephen A. Altobelli; Howard C. Bryant; Richard S. Larson; Edward R. Flynn

Both magnetic relaxometry and magnetic resonance imaging (MRI) can be used to detect and locate targeted magnetic nanoparticles, noninvasively and without ionizing radiation. Magnetic relaxometry offers advantages in terms of its specificity (only nanoparticles are detected) and the linear dependence of the relaxometry signal on the number of nanoparticles present. In this study, detection of single-core iron oxide nanoparticles by superconducting quantum interference device (SQUID)-detected magnetic relaxometry and standard 4.7 T MRI are compared. The nanoparticles were conjugated to a Her2 monoclonal antibody and targeted to Her2-expressing MCF7/Her2-18 (breast cancer cells); binding of the nanoparticles to the cells was assessed by magnetic relaxometry and iron assay. The same nanoparticle-labeled cells, serially diluted, were used to assess the detection limits and MR relaxivities. The detection limit of magnetic relaxometry was 125 000 nanoparticle-labeled cells at 3 cm from the SQUID sensors. T(2)-weighted MRI yielded a detection limit of 15 600 cells in a 150 µl volume, with r(1) = 1.1 mm(-1) s(-1) and r(2) = 166 mm(-1) s(-1). Her2-targeted nanoparticles were directly injected into xenograft MCF7/Her2-18 tumors in nude mice, and magnetic relaxometry imaging and 4.7 T MRI were performed, enabling direct comparison of the two techniques. Co-registration of relaxometry images and MRI of mice resulted in good agreement. A method for obtaining accurate quantification of microgram quantities of iron in the tumors and liver by relaxometry was also demonstrated. These results demonstrate the potential of SQUID-detected magnetic relaxometry imaging for the specific detection of breast cancer and the monitoring of magnetic nanoparticle-based therapies.


Physics in Medicine and Biology | 2010

Characterization of Single-core Magnetite Nanoparticles for Magnetic Imaging by SQUID-relaxometry

Natalie L. Adolphi; Dale L. Huber; Howard C. Bryant; Todd C. Monson; Danielle L. Fegan; JitKang Lim; Jason E. Trujillo; Trace E. Tessier; Debbie M. Lovato; Kimberly S. Butler; Paula Polyak Provencio; Helen J. Hathaway; Sara A. Majetich; Richard S. Larson; Edward R. Flynn

Optimizing the sensitivity of SQUID (superconducting quantum interference device) relaxometry for detecting cell-targeted magnetic nanoparticles for in vivo diagnostics requires nanoparticles with a narrow particle size distribution to ensure that the Néel relaxation times fall within the measurement timescale (50 ms-2 s, in this work). To determine the optimum particle size, single-core magnetite nanoparticles (with nominal average diameters 20, 25, 30 and 35 nm) were characterized by SQUID relaxometry, transmission electron microscopy, SQUID susceptometry, dynamic light scattering and zeta potential analysis. The SQUID relaxometry signal (detected magnetic moment/kg) from both the 25 nm and 30 nm particles was an improvement over previously studied multi-core particles. However, the detected moments were an order of magnitude lower than predicted based on a simple model that takes into account the measured size distributions (but neglects dipolar interactions and polydispersity of the anisotropy energy density), indicating that improved control of several different nanoparticle properties (size, shape and coating thickness) will be required to achieve the highest detection sensitivity. Antibody conjugation and cell incubation experiments show that single-core particles enable a higher detected moment per cell, but also demonstrate the need for improved surface treatments to mitigate aggregation and improve specificity.


Cancer Research | 2009

Enhanced Leukemia Cell Detection Using a Novel Magnetic Needle and Nanoparticles

Jason E. Jaetao; Kimberly S. Butler; Natalie L. Adolphi; Debbie M. Lovato; Howard C. Bryant; Ian Rabinowitz; Stuart S. Winter; Trace E. Tessier; Helen J. Hathaway; Christian Bergemann; Edward R. Flynn; Richard S. Larson

Acute leukemia is a hematopoietic malignancy for which the accurate measurement of minimal residual disease is critical to determining prognosis and treatment. Although bone marrow aspiration and light microscopy remain the current standard of care for detecting residual disease, these approaches cannot reliably discriminate less than 5% lymphoblast cells. To improve the detection of leukemia cells in the marrow, we developed a novel apparatus that utilizes antibodies conjugated to superparamagnetic iron oxide nanoparticles (SPION) and directed against the acute leukemia antigen CD34, coupled with a magnetic needle biopsy. Leukemia cell lines expressing high or minimal CD34 were incubated with anti-CD34-conjugated SPIONs. Three separate approaches including microscopy, superconducting quantum interference device magnetometry, and in vitro magnetic needle extraction were then used to assess cell sampling. We found that CD34-conjugated nanoparticles preferentially bind high CD34-expressing cell lines. Furthermore, the magnetic needle enabled identification of both cell line and patient leukemia cells diluted into normal blood at concentrations below those normally found in remission marrow samples. Finally, the magnetic needle enhanced the percentage of lymphoblasts detectable by light microscopy by 10-fold in samples of fresh bone marrow aspirate approximating minimal residual disease. These data suggest that bone marrow biopsy using antigen-targeted magnetic nanoparticles and a magnetic needle for the evaluation of minimal residual disease in CD34-positive acute leukemias can significantly enhance sensitivity compared with the current standard of care.


Brain Topography | 2001

Dipole localization of human induced focal afterdischarge seizure in simultaneous magnetoencephalography and electrocorticography.

William W. Sutherling; Massoud Akhtari; Adam N. Mamelak; John C. Mosher; Deborah Arthur; Steve Sands; Peter Weiss; Nancy Lopez; Mauricio DiMauro; Edward R. Flynn; Richard M. Leahy

Localizations were compared for the same human seizure between simultaneously measured MEG and iEEG, which were both co-registered to MRI. The whole-cortex neuromagnetometer localized a dipole in a sphere phantom, co-registered to the MEG sensor array, with an error of 1.4 mm. A focal afterdischarge seizure was induced in a patient with partial epilepsy, by stimulation at a subdural electrocorticography (ECoG) electrode with a known location, which was co-registered to the MRI and to the MEG sensor array. The simultaneous MEG and ECoG during the 30-second seizure was measured and analyzed using the single, moving dipole model, which is the localization model used clinically. The dipole localizations from simultaneous whole cortex 68-channel MEG and 64-channel ECoG were then compared for the repetitive spiking at six different times during the seizure. There were two main regions of MEG and ECoG activity. The locations of these regions were confirmed by determining the location clusters of 8,000 dipoles on ECoG at consecutive time points during the seizure. The mean distances between the stimulated electrode location versus the dipole location of the MEG and versus the dipole location of the ECoG were each about one (1) centimeter. The mean distance between the dipole locations of the MEG versus the dipole locations of the ECoG was about 2 cm. These errors were compared to errors of MEG and ECoG reported previously for phantoms and for somatosensory evoked responses (SER) in patients. Comparing the findings from the present study to those from prior studies, there appeared to be the expected stepwise increase in mean localization error progressing from the phantom, to the SER, to the seizure.


Physics in Medicine and Biology | 2007

Magnetic needles and superparamagnetic cells

Howard C. Bryant; Dmitri A. Sergatskov; Debbie M. Lovato; Natalie L. Adolphi; Richard S. Larson; Edward R. Flynn

Superparamagnetic nanoparticles can be attached in great numbers to pathogenic cells using specific antibodies so that the magnetically-labeled cells themselves become superparamagnets. The cells can then be manipulated and drawn out of biological fluids, as in a biopsy, very selectively using a magnetic needle. We examine the origins and uncertainties in the forces exerted on magnetic nanoparticles by static magnetic fields, leading to a model for trajectories and collection times of dilute superparamagnetic cells in biological fluids. We discuss the design and application of such magnetic needles and the theory of collection times. We compare the mathematical model to measurements in a variety of media including blood. For more information on this article, see medicalphysicsweb.org.


Brain Topography | 2003

A Model for Frequency Dependence of Conductivities of the Live Human Skull

Massoud Akhtari; H.C. Bryant; David Emin; W. Merrifield; A. N. Mamelak; Edward R. Flynn; Jerry J. Shih; M. Mandelkern; A. Matlachov; Ranken Dm; E.D. Best; M. A. DiMauro; R. R. Lee; William W. Sutherling

A mathematical model (σ(ω) ≃ Aωα, where, σ ≡ conductivity, ω =2πf ≡ applied frequency (Hz), A (amplitude) and α (unitless) ≡ search parameters) was used to fit the frequency dependence of electrical conductivities of compact, spongiosum, and bulk layers of the live and, subsequently, dead human skull samples. The results indicate that the fit of this model to the experimental data is excellent. The ranges of values of A and α were, spongiform (12.0-36.5, 0.0083-0.0549), the top compact (5.02-7.76, -0.137-0.0144), the lower compact (2.31-10.6, 0.0267-0.0452), and the bulk (7.46-10.6, 0.0133-0.0239). The respective values A and α for the respective layers of the dead skull samples were (40.1-89.7, -0.0017-0.0287), (5.53-14.5, -0.0296 - -0.0061), (4.58-15.9, -0.0226-0.0268), and (12.7-25.3, -0.0158-0.0132).


Biomedizinische Technik | 2015

Magnetic relaxometry as applied to sensitive cancer detection and localization

Leyma P. De Haro; Todor Karaulanov; Erika C. Vreeland; Bill Anderson; Helen J. Hathaway; Dale L. Huber; Christopher Nettles; Andrew D. Price; Todd C. Monson; Edward R. Flynn

Abstract Background: Here we describe superparamagnetic relaxometry (SPMR), a technology that utilizes highly sensitive magnetic sensors and superparamagnetic nanoparticles for cancer detection. Using SPMR, we sensitively and specifically detect nanoparticles conjugated to biomarkers for various types of cancer. SPMR offers high contrast in vivo, as there is no superparamagnetic background, and bones and tissue are transparent to the magnetic fields. Methods: In SPMR measurements, a brief magnetizing pulse is used to align superparamagnetic nanoparticles of a discrete size. Following the pulse, an array of superconducting quantum interference detectors (SQUID) sensors detect the decaying magnetization field. NP size is chosen so that, when bound, the induced field decays in seconds. They are functionalized with specific biomarkers and incubated with cancer cells in vitro to determine specificity and cell binding. For in vivo experiments, functionalized NPs are injected into mice with xenograft tumors, and field maps are generated to localize tumor sites. Results: Superparamagnetic NPs developed here have small size dispersion. Cell incubation studies measure specificity for different cell lines and antibodies with very high contrast. In vivo animal measurements verify SPMR localization of tumors. Our results indicate that SPMR possesses sensitivity more than 2 orders of magnitude better than previously reported.


Cell Transplantation | 2013

Development of Antibody-Tagged Nanoparticles for Detection of Transplant Rejection Using Biomagnetic Sensors:

Kimberly S. Butler; Debbie M. Lovato; Natalie L. Adolphi; Robert Belfon; Danielle L. Fegan; Todd C. Monson; Helen J. Hathaway; Dale L. Huber; Trace E. Tessier; Howard C. Bryant; Edward R. Flynn; Richard S. Larson

Organ transplantation is a life-saving procedure and the preferred method of treatment for a growing number of disease states. The advent of new immunosuppressants and improved care has led to great advances in both patient and graft survival. However, acute T-cell-mediated graft rejection occurs in a significant quantity of recipients and remains a life-threatening condition. Acute rejection is associated with decrease in long-term graft survival, demonstrating a need to carefully monitor transplant patients. Current diagnostic criteria for transplant rejection rely on invasive tissue biopsies or relatively nonspecific clinical features. A noninvasive way is needed to detect, localize, and monitor transplant rejection. Capitalizing on advances in targeted contrast agents and magnetic-based detection technology, we developed anti-CD3 antibody-tagged nanoparticles. T cells were found to bind preferentially to antibody-tagged nanoparticles, as identified through light microscopy, transmission electron microscopy, and confocal microscopy. Using mouse skin graft models, we were also able to demonstrate in vivo vascular delivery of T-cell targeted nanoparticles. We conclude that targeting lymphocytes with magnetic nanoparticles is conducive to developing a novel, noninvasive strategy for identifying transplant rejection.

Collaboration


Dive into the Edward R. Flynn's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Dale L. Huber

Sandia National Laboratories

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Todd C. Monson

Sandia National Laboratories

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Todor Karaulanov

Los Alamos National Laboratory

View shared research outputs
Researchain Logo
Decentralizing Knowledge