Techniques for temperature monitoring during laser-induced thermotherapy: An overview

Paola Saccomandi; Emiliano Schena; Sergio Silvestri

Abstract Laser-induced thermotherapy (LITT) is a hyperthermic procedure recently employed to treat cancer in several organs. The amount of coagulated tissue depends on the temperature distribution around the applicator, which plays a crucial role for an optimal outcome: the removal of the whole neoplastic tissue, whilst preventing damage to the surrounding healthy tissue. Although feedback concerning tissue temperature could be useful to drive the physician in the adjustment of laser settings and treatment duration, LITT is usually performed without real-time monitoring of tissue temperature. During recent decades, many thermometric techniques have been developed to be used during thermal therapies. This paper provides an overview of techniques and sensors employed for temperature measurement during tissue hyperthermia, focusing on LITT, and an investigation of their performances in this application. The paper focuses on the most promising and widespread temperature monitoring techniques, splitting them into two groups: the former includes invasive techniques based on the use of thermocouples and fibre-optic sensors; the second analyses non-invasive methods, i.e. magnetic resonance imaging-, computerised tomography- and ultrasound-based thermometry. Background information on measuring principle, medical applications, advantages and weaknesses of each method are provided and discussed.


Sensors | 2013

Optical Fiber-Based MR-Compatible Sensors for Medical Applications: An Overview

Fabrizio Taffoni; Domenico Formica; Paola Saccomandi; Giovanni Di Pino; Emiliano Schena

During last decades, Magnetic Resonance (MR)—compatible sensors based on different techniques have been developed due to growing demand for application in medicine. There are several technological solutions to design MR-compatible sensors, among them, the one based on optical fibers presents several attractive features. The high elasticity and small size allow designing miniaturized fiber optic sensors (FOS) with metrological characteristics (e.g., accuracy, sensitivity, zero drift, and frequency response) adequate for most common medical applications; the immunity from electromagnetic interference and the absence of electrical connection to the patient make FOS suitable to be used in high electromagnetic field and intrinsically safer than conventional technologies. These two features further heightened the potential role of FOS in medicine making them especially attractive for application in MRI. This paper provides an overview of MR-compatible FOS, focusing on the sensors employed for measuring physical parameters in medicine (i.e., temperature, force, torque, strain, and position). The working principles of the most promising FOS are reviewed in terms of their relevant advantages and disadvantages, together with their applications in medicine.


IEEE Transactions on Biomedical Engineering | 2012

Theoretical Analysis and Experimental Evaluation of Laser-Induced Interstitial Thermotherapy in Ex Vivo Porcine Pancreas

Paola Saccomandi; Emiliano Schena; Michele Arturo Caponero; F. M. Di Matteo; M. Martino; M. Pandolfi; Sergio Silvestri

Laser-induced interstitial thermotherapy (LITT) has been recently applied to pancreas in animal models for ablation purpose. Assessment of thermal effects due to the laser-pancreatic tissue interaction is a critical factor in validating the procedure feasibility and safety. A mathematical model based on bioheat equation and its experimental assessment was developed. The LITT procedure was performed on 40 ex vivo porcine pancreases, with an Nd:YAG (1064 nm) energy of 1000 J and power from 1.5 up to 10 W conveyed by a quartz optical fiber with 300 μm diameter. Six fiber Bragg grating sensors have been utilized to measure temperature distribution as a function of time at fixed distances from the applicator tip within pancreas undergoing LITT. Simulations and experiments show temperature variations ΔT steeply decreasing with distance from the applicator at higher power values: at 6 W, ΔT >; 40°C at 5 mm and ΔT ≅ 5°C at 10 mm. ΔT nonlinearly increases with power close to the applicator. Ablated and coagulated tissue volumes have also been measured and experimental results agree with theoretical ones. Despite the absence of data in the current literature on pancreas optical parameters, the model allowed a quite good prediction of thermal effects. The prediction of LITT effects on pancreas is necessary to assess laser dosimetry.


Thorax | 2010

Breathing pattern and chest wall volumes during exercise in patients with cystic fibrosis, pulmonary fibrosis and COPD before and after lung transplantation

H. Wilkens; B. Weingard; A. Lo Mauro; Emiliano Schena; Antonio Pedotti; G. Sybrecht; Andrea Aliverti

Background Pulmonary fibrosis (PF), cystic fibrosis (CF) and chronic obstructive pulmonary disease (COPD) often cause chronic respiratory failure (CRF). Methods In order to investigate if there are different patterns of adaptation of the ventilatory pump in CRF, in three groups of lung transplant candidates with PF (n=9, forced expiratory volume in 1 s (FEV1)=37±3% predicted, forced vital capacity (FVC)=32±2% predicted), CF (n=9, FEV1=22±3% predicted, FVC=30±3% predicted) and COPD (n=21, FEV1=21±1% predicted, FVC=46±2% predicted), 10 healthy controls and 16 transplanted patients, total and compartmental chest wall volumes were measured by opto-electronic plethysmography during rest and exercise. Results Three different breathing patterns were found during CRF in PF, CF and COPD. Patients with COPD were characterised by a reduced duty cycle at rest and maximal exercise (34±1%, p<0.001), while patients with PF and CF showed an increased breathing frequency (49±6 and 34±2/min, respectively) and decreased tidal volume (0.75±0.10 and 0.79±0.07 litres) (p<0.05). During exercise, end-expiratory chest wall and rib cage volumes increased significantly in patients with COPD and CF but not in those with PF. End-inspiratory volumes did not increase in CF and PF. The breathing pattern of transplanted patients was similar to that of healthy controls. Conclusions There are three distinct patterns of CRF in patients with PF, CF and COPD adopted by the ventilatory pump to cope with the underlying lung disease that may explain why patients with PF and CF are prone to respiratory failure earlier than patients with COPD. After lung transplantation the chronic adaptations of the ventilatory pattern to advanced lung diseases are reversible and indicate that the main contributing factor is the lung itself rather than systemic effects of the disease.


Medical Engineering & Physics | 2015

Flow measurement in mechanical ventilation: A review

Emiliano Schena; Carlo Massaroni; Paola Saccomandi; Stefano Cecchini

Accurate monitoring of flow rate and volume exchanges is essential to minimize ventilator-induced lung injury. Mechanical ventilators employ flowmeters to estimate the amount of gases delivered to patients and use the flow signal as a feedback to adjust the desired amount of gas to be delivered. Since flowmeters play a crucial role in this field, they are required to fulfill strict criteria in terms of dynamic and static characteristics. Therefore, mechanical ventilators are equipped with only the following kinds of flowmeters: linear pneumotachographs, fixed and variable orifice meters, hot wire anemometers, and ultrasonic flowmeters. This paper provides an overview of these sensors. Their working principles are described together with their relevant advantages and disadvantages. Furthermore, the most promising emerging approaches for flowmeters design (i.e., fiber optic technology and three dimensional micro-fabrication) are briefly reviewed showing their potential for this application.


International Journal of Hyperthermia | 2014

CT-based thermometry: An overview

F. Fani; Emiliano Schena; Paola Saccomandi; Sergio Silvestri

Abstract The dependence of computed tomography (CT) values on temperature has been pointed out by several authors since the late 1970s. They emphasised the importance of this phenomenon on the calibration process with water equivalent phantoms of the CT scanners. Few years later the potential of CT thermometry for non-invasive temperature mapping during thermal procedures was investigated. The interest on the employment of this technique during thermal treatments has been recently renewed with the improvement of modern CT scanner performances and with the increased popularity of minimally invasive thermal techniques for cancer treatment. A good thermometry allows avoiding unintended damage of the healthy tissues during the procedure by providing a detailed tissue temperature distribution; therefore, it is recommended in order to achieve good effectiveness of the thermal treatment. Researchers have been working on this issue for more than four decades and different non-invasive solutions have been proposed, i.e., microwave thermal imaging, infrared (IR)-, ultrasound-, magnetic-resonance (MR)-, and CT-based thermometry. This review aims to summarise the essential physics and the currently available data on CT-based thermometry and to elucidate the potential use of this technique during thermal procedures. Background information on measuring principle, an investigation of the performances achieved by this technique and the thermal sensitivity of the CT-number of different organs are provided and discussed.


Micromachines | 2012

Micromachined Flow Sensors in Biomedical Applications

Sergio Silvestri; Emiliano Schena

Application fields of micromachined devices are growing very rapidly due to the continuous improvement of three dimensional technologies of micro-fabrication. In particular, applications of micromachined sensors to monitor gas and liquid flows hold immense potential because of their valuable characteristics (e.g., low energy consumption, relatively good accuracy, the ability to measure very small flow, and small size). Moreover, the feedback provided by integrating microflow sensors to micro mass flow controllers is essential to deliver accurately set target small flows. This paper is a review of some application areas in the biomedical field of micromachined flow sensors, such as blood flow, respiratory monitoring, and drug delivery among others. Particular attention is dedicated to the description of the measurement principles utilized in early and current research. Finally, some observations about characteristics and issues of these devices are also reported.


Physics in Medicine and Biology | 2013

Experimental assessment of CT-based thermometry during laser ablation of porcine pancreas.

Emiliano Schena; Paola Saccomandi; Francesco Giurazza; Michele Arturo Caponero; Luca Mortato; F. M. Di Matteo; F. Panzera; R. Del Vescovo; B. Beomonte Zobel; Sergio Silvestri

Laser interstitial thermotherapy (LITT) is employed to destroy tumors in organs, and its outcome strongly depends on the temperature distribution inside the treated tissue. The recent introduction of computed tomography (CT) scan thermometry, based on the CT number dependence of the tissue with temperature, overcomes the invasiveness of other techniques used to monitor temperature during LITT. The averaged CT number (ROI = 0.02 cm(2)) of an ex vivo swine pancreas is monitored during LITT (Nd:YAG laser power of 3 W, treatment time: 120 s) at different distances from the applicator (from 4 to 30 mm). The averaged CT number shows a clear decrease during treatment: it is highest at 4 mm from the applicator (mean variation in the whole treatment of -0.256 HU s(-1)) and negligible at 30 mm, since the highest temperature increase is present close to the applicator (i.e., 45 °C at 4 mm and 25 °C at 6 mm). To obtain the relationship between CT numbers and pancreas temperature, the reference temperature was measured by 12 fiber Bragg grating sensors. The CT number decreases as a function of temperature, showing a nonlinear trend with a mean thermal sensitivity of -0.50 HU °C(-1). Results here reported are the first assessment of pancreatic CT number dependence on temperature, at the best of our knowledge. Findings can be useful to further investigate CT scan thermometry during LITT on the pancreas.


Journal of Functional Biomaterials | 2015

Medical smart textiles based on fiber optic technology: an overview.

Carlo Massaroni; Paola Saccomandi; Emiliano Schena

The growing interest in the development of smart textiles for medical applications is driven by the aim to increase the mobility of patients who need a continuous monitoring of such physiological parameters. At the same time, the use of fiber optic sensors (FOSs) is gaining large acceptance as an alternative to traditional electrical and mechanical sensors for the monitoring of thermal and mechanical parameters. The potential impact of FOSs is related to their good metrological properties, their small size and their flexibility, as well as to their immunity from electromagnetic field. Their main advantage is the possibility to use textile based on fiber optic in a magnetic resonance imaging environment, where standard electronic sensors cannot be employed. This last feature makes FOSs suitable for monitoring biological parameters (e.g., respiratory and heartbeat monitoring) during magnetic resonance procedures. Research interest in combining FOSs and textiles into a single structure to develop wearable sensors is rapidly growing. In this review we provide an overview of the state-of-the-art of textiles, which use FOSs for monitoring of mechanical parameters of physiological interest. In particular we briefly describe the working principle of FOSs employed in this field and their relevant advantages and disadvantages. Also reviewed are their applications for the monitoring of mechanical parameters of physiological interest.


Forensic Science International | 2012

Determination of stature from skeletal and skull measurements by CT scan evaluation

Francesco Giurazza; Riccardo Del Vescovo; Emiliano Schena; Sofia Battisti; Roberto Luigi Cazzato; Francesco Rosario Grasso; Sergio Silvestri; V. Denaro; Bruno Beomonte Zobel

The aim of this article is to find a correlation between height and femur/skull measurements through Computed Tomography (CT) scans and derive regression equations for total skeletal height estimation in the Caucasian population. We selected 200 Caucasian patients from March 2010 to July 2011 who had to perform a CT scan for cancer restaging. The mean age is 64.5 years. Both sexes are represented by the same number of persons. Patients have executed a total body CT scan with contrast; once scan accomplished, we measured height through a digital scales. We analyzed CT scans of each patient, obtaining multiplanar reconstruction in sagittal and coronal planes with 1mm of thickness, and we measured 10 diameters of skull and femur. Then we performed a single and a multiple regression analysis considering the three diameters that better correlated with height. The skeletal diameters with the highest correlation coefficients with stature were femur lengths, length of cranial base (Ba-N), and distance from the posterior extremity of the cranial base to the inferior point of the nasal bone (Ba-NB). Although both femur and skull are skeletal segments used for stature estimation, in our sample femur gave stronger correlation with height than skull. h=35.7+1.48·BaN+2.32·BaNB+2.53·FEM and h=3.06·FEM+72.6 are the formulae that provided the most accurate stature assessment using multiple and single regression analysis respectively.

Collaboration


Dive into the Emiliano Schena's collaboration.

Top Co-Authors

Avatar

Paola Saccomandi

Università Campus Bio-Medico

View shared research outputs
Top Co-Authors

Avatar

Sergio Silvestri

Università Campus Bio-Medico

View shared research outputs
Top Co-Authors

Avatar

Carlo Massaroni

Università Campus Bio-Medico

View shared research outputs
Top Co-Authors

Avatar

Francesco Giurazza

Università Campus Bio-Medico

View shared research outputs
Top Co-Authors

Avatar

Domenico Formica

Università Campus Bio-Medico

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Bruno Beomonte Zobel

Università Campus Bio-Medico

View shared research outputs
Top Co-Authors

Avatar

Giulia Frauenfelder

Università Campus Bio-Medico

View shared research outputs
Researchain Logo
Decentralizing Knowledge