Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Paola Saccomandi is active.

Publication


Featured researches published by Paola Saccomandi.


International Journal of Hyperthermia | 2013

Techniques for temperature monitoring during laser-induced thermotherapy: An overview

Paola Saccomandi; Emiliano Schena; Sergio Silvestri

Abstract Laser-induced thermotherapy (LITT) is a hyperthermic procedure recently employed to treat cancer in several organs. The amount of coagulated tissue depends on the temperature distribution around the applicator, which plays a crucial role for an optimal outcome: the removal of the whole neoplastic tissue, whilst preventing damage to the surrounding healthy tissue. Although feedback concerning tissue temperature could be useful to drive the physician in the adjustment of laser settings and treatment duration, LITT is usually performed without real-time monitoring of tissue temperature. During recent decades, many thermometric techniques have been developed to be used during thermal therapies. This paper provides an overview of techniques and sensors employed for temperature measurement during tissue hyperthermia, focusing on LITT, and an investigation of their performances in this application. The paper focuses on the most promising and widespread temperature monitoring techniques, splitting them into two groups: the former includes invasive techniques based on the use of thermocouples and fibre-optic sensors; the second analyses non-invasive methods, i.e. magnetic resonance imaging-, computerised tomography- and ultrasound-based thermometry. Background information on measuring principle, medical applications, advantages and weaknesses of each method are provided and discussed.


Sensors | 2013

Optical Fiber-Based MR-Compatible Sensors for Medical Applications: An Overview

Fabrizio Taffoni; Domenico Formica; Paola Saccomandi; Giovanni Di Pino; Emiliano Schena

During last decades, Magnetic Resonance (MR)—compatible sensors based on different techniques have been developed due to growing demand for application in medicine. There are several technological solutions to design MR-compatible sensors, among them, the one based on optical fibers presents several attractive features. The high elasticity and small size allow designing miniaturized fiber optic sensors (FOS) with metrological characteristics (e.g., accuracy, sensitivity, zero drift, and frequency response) adequate for most common medical applications; the immunity from electromagnetic interference and the absence of electrical connection to the patient make FOS suitable to be used in high electromagnetic field and intrinsically safer than conventional technologies. These two features further heightened the potential role of FOS in medicine making them especially attractive for application in MRI. This paper provides an overview of MR-compatible FOS, focusing on the sensors employed for measuring physical parameters in medicine (i.e., temperature, force, torque, strain, and position). The working principles of the most promising FOS are reviewed in terms of their relevant advantages and disadvantages, together with their applications in medicine.


IEEE Transactions on Biomedical Engineering | 2012

Theoretical Analysis and Experimental Evaluation of Laser-Induced Interstitial Thermotherapy in Ex Vivo Porcine Pancreas

Paola Saccomandi; Emiliano Schena; Michele Arturo Caponero; F. M. Di Matteo; M. Martino; M. Pandolfi; Sergio Silvestri

Laser-induced interstitial thermotherapy (LITT) has been recently applied to pancreas in animal models for ablation purpose. Assessment of thermal effects due to the laser-pancreatic tissue interaction is a critical factor in validating the procedure feasibility and safety. A mathematical model based on bioheat equation and its experimental assessment was developed. The LITT procedure was performed on 40 ex vivo porcine pancreases, with an Nd:YAG (1064 nm) energy of 1000 J and power from 1.5 up to 10 W conveyed by a quartz optical fiber with 300 μm diameter. Six fiber Bragg grating sensors have been utilized to measure temperature distribution as a function of time at fixed distances from the applicator tip within pancreas undergoing LITT. Simulations and experiments show temperature variations ΔT steeply decreasing with distance from the applicator at higher power values: at 6 W, ΔT >; 40°C at 5 mm and ΔT ≅ 5°C at 10 mm. ΔT nonlinearly increases with power close to the applicator. Ablated and coagulated tissue volumes have also been measured and experimental results agree with theoretical ones. Despite the absence of data in the current literature on pancreas optical parameters, the model allowed a quite good prediction of thermal effects. The prediction of LITT effects on pancreas is necessary to assess laser dosimetry.


Medical Engineering & Physics | 2015

Flow measurement in mechanical ventilation: A review

Emiliano Schena; Carlo Massaroni; Paola Saccomandi; Stefano Cecchini

Accurate monitoring of flow rate and volume exchanges is essential to minimize ventilator-induced lung injury. Mechanical ventilators employ flowmeters to estimate the amount of gases delivered to patients and use the flow signal as a feedback to adjust the desired amount of gas to be delivered. Since flowmeters play a crucial role in this field, they are required to fulfill strict criteria in terms of dynamic and static characteristics. Therefore, mechanical ventilators are equipped with only the following kinds of flowmeters: linear pneumotachographs, fixed and variable orifice meters, hot wire anemometers, and ultrasonic flowmeters. This paper provides an overview of these sensors. Their working principles are described together with their relevant advantages and disadvantages. Furthermore, the most promising emerging approaches for flowmeters design (i.e., fiber optic technology and three dimensional micro-fabrication) are briefly reviewed showing their potential for this application.


International Journal of Hyperthermia | 2014

CT-based thermometry: An overview

F. Fani; Emiliano Schena; Paola Saccomandi; Sergio Silvestri

Abstract The dependence of computed tomography (CT) values on temperature has been pointed out by several authors since the late 1970s. They emphasised the importance of this phenomenon on the calibration process with water equivalent phantoms of the CT scanners. Few years later the potential of CT thermometry for non-invasive temperature mapping during thermal procedures was investigated. The interest on the employment of this technique during thermal treatments has been recently renewed with the improvement of modern CT scanner performances and with the increased popularity of minimally invasive thermal techniques for cancer treatment. A good thermometry allows avoiding unintended damage of the healthy tissues during the procedure by providing a detailed tissue temperature distribution; therefore, it is recommended in order to achieve good effectiveness of the thermal treatment. Researchers have been working on this issue for more than four decades and different non-invasive solutions have been proposed, i.e., microwave thermal imaging, infrared (IR)-, ultrasound-, magnetic-resonance (MR)-, and CT-based thermometry. This review aims to summarise the essential physics and the currently available data on CT-based thermometry and to elucidate the potential use of this technique during thermal procedures. Background information on measuring principle, an investigation of the performances achieved by this technique and the thermal sensitivity of the CT-number of different organs are provided and discussed.


Physics in Medicine and Biology | 2013

Experimental assessment of CT-based thermometry during laser ablation of porcine pancreas.

Emiliano Schena; Paola Saccomandi; Francesco Giurazza; Michele Arturo Caponero; Luca Mortato; F. M. Di Matteo; F. Panzera; R. Del Vescovo; B. Beomonte Zobel; Sergio Silvestri

Laser interstitial thermotherapy (LITT) is employed to destroy tumors in organs, and its outcome strongly depends on the temperature distribution inside the treated tissue. The recent introduction of computed tomography (CT) scan thermometry, based on the CT number dependence of the tissue with temperature, overcomes the invasiveness of other techniques used to monitor temperature during LITT. The averaged CT number (ROI = 0.02 cm(2)) of an ex vivo swine pancreas is monitored during LITT (Nd:YAG laser power of 3 W, treatment time: 120 s) at different distances from the applicator (from 4 to 30 mm). The averaged CT number shows a clear decrease during treatment: it is highest at 4 mm from the applicator (mean variation in the whole treatment of -0.256 HU s(-1)) and negligible at 30 mm, since the highest temperature increase is present close to the applicator (i.e., 45 °C at 4 mm and 25 °C at 6 mm). To obtain the relationship between CT numbers and pancreas temperature, the reference temperature was measured by 12 fiber Bragg grating sensors. The CT number decreases as a function of temperature, showing a nonlinear trend with a mean thermal sensitivity of -0.50 HU °C(-1). Results here reported are the first assessment of pancreatic CT number dependence on temperature, at the best of our knowledge. Findings can be useful to further investigate CT scan thermometry during LITT on the pancreas.


Journal of Functional Biomaterials | 2015

Medical smart textiles based on fiber optic technology: an overview.

Carlo Massaroni; Paola Saccomandi; Emiliano Schena

The growing interest in the development of smart textiles for medical applications is driven by the aim to increase the mobility of patients who need a continuous monitoring of such physiological parameters. At the same time, the use of fiber optic sensors (FOSs) is gaining large acceptance as an alternative to traditional electrical and mechanical sensors for the monitoring of thermal and mechanical parameters. The potential impact of FOSs is related to their good metrological properties, their small size and their flexibility, as well as to their immunity from electromagnetic field. Their main advantage is the possibility to use textile based on fiber optic in a magnetic resonance imaging environment, where standard electronic sensors cannot be employed. This last feature makes FOSs suitable for monitoring biological parameters (e.g., respiratory and heartbeat monitoring) during magnetic resonance procedures. Research interest in combining FOSs and textiles into a single structure to develop wearable sensors is rapidly growing. In this review we provide an overview of the state-of-the-art of textiles, which use FOSs for monitoring of mechanical parameters of physiological interest. In particular we briefly describe the working principle of FOSs employed in this field and their relevant advantages and disadvantages. Also reviewed are their applications for the monitoring of mechanical parameters of physiological interest.


Sensors | 2016

Fiber optic sensors for temperature monitoring during thermal treatments: An overview

Emiliano Schena; Daniele Tosi; Paola Saccomandi; Elfed Lewis; Taesung Kim

During recent decades, minimally invasive thermal treatments (i.e., Radiofrequency ablation, Laser ablation, Microwave ablation, High Intensity Focused Ultrasound ablation, and Cryo-ablation) have gained widespread recognition in the field of tumor removal. These techniques induce a localized temperature increase or decrease to remove the tumor while the surrounding healthy tissue remains intact. An accurate measurement of tissue temperature may be particularly beneficial to improve treatment outcomes, because it can be used as a clear end-point to achieve complete tumor ablation and minimize recurrence. Among the several thermometric techniques used in this field, fiber optic sensors (FOSs) have several attractive features: high flexibility and small size of both sensor and cabling, allowing insertion of FOSs within deep-seated tissue; metrological characteristics, such as accuracy (better than 1 °C), sensitivity (e.g., 10 pm·°C−1 for Fiber Bragg Gratings), and frequency response (hundreds of kHz), are adequate for this application; immunity to electromagnetic interference allows the use of FOSs during Magnetic Resonance- or Computed Tomography-guided thermal procedures. In this review the current status of the most used FOSs for temperature monitoring during thermal procedure (e.g., fiber Bragg Grating sensors; fluoroptic sensors) is presented, with emphasis placed on their working principles and metrological characteristics. The essential physics of the common ablation techniques are included to explain the advantages of using FOSs during these procedures.


Biosensors | 2014

Microfabricated Tactile Sensors for Biomedical Applications: A Review

Paola Saccomandi; Emiliano Schena; Calogero Maria Oddo; Loredana Zollo; Sergio Silvestri; Eugenio Guglielmelli

During the last decades, tactile sensors based on different sensing principles have been developed due to the growing interest in robotics and, mainly, in medical applications. Several technological solutions have been employed to design tactile sensors; in particular, solutions based on microfabrication present several attractive features. Microfabrication technologies allow for developing miniaturized sensors with good performance in terms of metrological properties (e.g., accuracy, sensitivity, low power consumption, and frequency response). Small size and good metrological properties heighten the potential role of tactile sensors in medicine, making them especially attractive to be integrated in smart interfaces and microsurgical tools. This paper provides an overview of microfabricated tactile sensors, focusing on the mean principles of sensing, i.e., piezoresistive, piezoelectric and capacitive sensors. These sensors are employed for measuring contact properties, in particular force and pressure, in three main medical fields, i.e., prosthetics and artificial skin, minimal access surgery and smart interfaces for biomechanical analysis. The working principles and the metrological properties of the most promising tactile, microfabricated sensors are analyzed, together with their application in medicine. Finally, the new emerging technologies in these fields are briefly described.


Biosensors | 2015

Smart Textile Based on Fiber Bragg Grating Sensors for Respiratory Monitoring: Design and Preliminary Trials

Marco Ciocchetti; Carlo Massaroni; Paola Saccomandi; Michele Arturo Caponero; Andrea Polimadei; Domenico Formica; Emiliano Schena

Continuous respiratory monitoring is important to assess adequate ventilation. We present a fiber optic-based smart textile for respiratory monitoring able to work during Magnetic Resonance (MR) examinations. The system is based on the conversion of chest wall movements into strain of two fiber Bragg grating (FBG) sensors, placed on the upper thorax (UT). FBGs are glued on the textile by an adhesive silicon rubber. To increase the system sensitivity, the FBGs positioning was led by preliminary experiments performed using an optoelectronic system: FBGs placed on the chest surface experienced the largest strain during breathing. System performances, in terms of respiratory period (TR), duration of inspiratory (TI) and expiratory (TE) phases, as well as left and right UT volumes, were assessed on four healthy volunteers. The comparison of results obtained by the proposed system and an optoelectronic plethysmography highlights the high accuracy in the estimation of TR, TI, and TE: Bland-Altman analysis shows mean of difference values lower than 0.045 s, 0.33 s, and 0.35 s for TR, TI, and TE, respectively. The mean difference of UT volumes between the two systems is about 8.3%. The promising results foster further development of the system to allow routine use during MR examinations.

Collaboration


Dive into the Paola Saccomandi's collaboration.

Top Co-Authors

Avatar

Emiliano Schena

Università Campus Bio-Medico

View shared research outputs
Top Co-Authors

Avatar

Sergio Silvestri

Università Campus Bio-Medico

View shared research outputs
Top Co-Authors

Avatar

Carlo Massaroni

Università Campus Bio-Medico

View shared research outputs
Top Co-Authors

Avatar

Francesco Giurazza

Università Campus Bio-Medico

View shared research outputs
Top Co-Authors

Avatar

Guido Costamagna

Catholic University of the Sacred Heart

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Giulia Frauenfelder

Università Campus Bio-Medico

View shared research outputs
Researchain Logo
Decentralizing Knowledge