Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Evan L. Neidholdt is active.

Publication


Featured researches published by Evan L. Neidholdt.


Journal of the American Chemical Society | 2010

Interfacial Reactions of Ozone with Surfactant Protein B in a Model Lung Surfactant System

Hugh I. Kim; Hyungjun Kim; Young Shik Shin; Luther W. Beegle; Seung Soon Jang; Evan L. Neidholdt; William A. Goddard; James R. Heath; Isik Kanik; J. L. Beauchamp

Oxidative stresses from irritants such as hydrogen peroxide and ozone (O(3)) can cause dysfunction of the pulmonary surfactant (PS) layer in the human lung, resulting in chronic diseases of the respiratory tract. For identification of structural changes of pulmonary surfactant protein B (SP-B) due to the heterogeneous reaction with O(3), field-induced droplet ionization (FIDI) mass spectrometry has been utilized. FIDI is a soft ionization method in which ions are extracted from the surface of microliter-volume droplets. We report structurally specific oxidative changes of SP-B(1-25) (a shortened version of human SP-B) at the air-liquid interface. We also present studies of the interfacial oxidation of SP-B(1-25) in a nonionizable 1-palmitoyl-2-oleoyl-sn-glycerol (POG) surfactant layer as a model PS system, where competitive oxidation of the two components is observed. Our results indicate that the heterogeneous reaction of SP-B(1-25) at the interface is quite different from that in the solution phase. In comparison with the nearly complete homogeneous oxidation of SP-B(1-25), only a subset of the amino acids known to react with ozone are oxidized by direct ozonolysis in the hydrophobic interfacial environment, both with and without the lipid surfactant layer. Combining these experimental observations with the results of molecular dynamics simulations provides an improved understanding of the interfacial structure and chemistry of a model lung surfactant system subjected to oxidative stress.


Review of Scientific Instruments | 2011

Laser ablation-miniature mass spectrometer for elemental and isotopic analysis of rocks

Mahadeva P. Sinha; Evan L. Neidholdt; Joel A. Hurowitz; Wolfgang Sturhahn; B. Beard; Michael H. Hecht

A laser ablation-miniature mass spectrometer (LA-MMS) for the chemical and isotopic measurement of rocks and minerals is described. In the LA-MMS method, neutral atoms ablated by a pulsed laser are led into an electron impact ionization source, where they are ionized by a 70 eV electron beam. This results in a secondary ion pulse typically 10-100 μs wide, compared to the original 5-10 ns laser pulse duration. Ions of different masses are then spatially dispersed along the focal plane of the magnetic sector of the miniature mass spectrometer (MMS) and measured in parallel by a modified CCD array detector capable of detecting ions directly. Compared to conventional scanning techniques, simultaneous measurement of the ion pulse along the focal plane effectively offers a 100% duty cycle over a wide mass range. LA-MMS offers a more quantitative assessment of elemental composition than techniques that detect ions directly generated by the ablation process because the latter can be strongly influenced by matrix effects that vary with the structure and geometry of the surface, the wavelength of the laser beam, and the not well characterized ionization efficiencies of the elements in the process. The above problems attendant to the direct ion analysis has been minimized in the LA-MMS by analyzing the ablated neutral species after their post-ionization by electron impaction. These neutral species are much more abundant than the directly ablated ions in the ablated vapor plume and are, therefore, expected to be characteristic of the chemical composition of the solid. Also, the electron impact ionization of elements is well studied and their ionization cross sections are known and easy to find in databases. Currently, the LA-MMS limit of detection is 0.4 wt.%. Here we describe LA-MMS elemental composition measurements of various minerals including microcline, lepidolite, anorthoclase, and USGS BCR-2G samples. The measurements of high precision isotopic ratios including (41)K/(39)K (0.077 ± 0.004) and (29)Si/(28)Si (0.052 ± 0.006) in these minerals by LA-MMS are also described. The LA-MMS has been developed as a prototype instrument system for space applications for geochemical and geochronological measurements on the surface of extraterrestrial bodies.


Analytical Chemistry | 2011

Switched Ferroelectric Plasma Ionizer (SwiFerr) for Ambient Mass Spectrometry

Evan L. Neidholdt; J. L. Beauchamp

We present the implementation of a switched ferroelectric plasma ionizer (SwiFerr) for ambient analysis of trace substances by mass spectrometry. The device utilizes the ferroelectric properties of barium titanate (BaTiO(3)) to take advantage of the high electric field resulting from polarization switching in the material. The source comprises a [001]-oriented barium titanate crystal (5 × 5 × 1 mm) with a metallic rear electrode and a metallic grid front electrode. When a high voltage AC waveform is applied to the rear electrode to switch polarization, the resulting electric field on the face of the crystal promotes electron emission and results in plasma formation between the crystal face and the grounded grid at ambient pressure. Interaction with this plasma and the resulting reagent ions effects ionization of trace neutrals. The source requires less than 1 W of power to operate under most circumstances, ionizes molecules with acidic and basic functional groups easily, and has proven quite versatile for ambient analysis of both vapor phase and aspirated powdered solid samples. Ionization of vapor phase samples of the organics triethylamine, tripropylamine, tributylamine, and pyridine results in observation of the singly protonated species in the positive ion mass spectrum with sensitivity extending into the high ppb range. With acetic acid, deprotonated clusters dominate the negative ion mass spectrum. Aerodynamic sampling of powdered samples is used to record mass spectra of the pharmaceuticals loperamide and ibuprofen. Chemical signatures, including protonated loperamide and deprotonated ibuprofen, are observed for each drug. The robust, low power source lends itself easily to miniaturization and incorporation in field-portable devices used for the rapid detection and characterization of trace substances and hazardous materials in a range of different environments.


Analytical Chemistry | 2013

Continuous Flow Ion Mobility Separation with Mass Spectrometric Detection Using a Nano-Radial Differential Mobility Analyzer at Low Flow Rates

Nicholas A. Brunelli; Evan L. Neidholdt; Konstantinos P. Giapis; J. L. Beauchamp

We describe a hybrid mass-mobility instrument in which a continuous-flow ion mobility classifier is used as a front-end separation device for mass spectrometric analysis of ions generated with an electrospray ionization source. Using nitrogen as a carrier gas, the resolving power of the nano-radial differential mobility analyzer (nRDMA) for nanometer-sized ions is 5-7 for tetraalkylammonium ions. Data are presented demonstrating the ability of the system to resolve the different aggregation and charge states of tetraalkylammonium ions and protonated peptides using a quadrupole ion trap (QIT) mass spectrometer to analyze the mobility-classified ions. Specifically, data are presented for the two charge states of the decapeptide Gramicidin S. A key feature of the new instrument is the ability to continuously transmit ions with specific mobilities to the mass spectrometer for manipulation and analysis.


Journal of the American Society for Mass Spectrometry | 2009

Ionization mechanism of the ambient pressure pyroelectric ion source (APPIS) and its applications to chemical nerve agent detection

Evan L. Neidholdt; J. L. Beauchamp

We present studies of the ionization mechanism operative in the ambient pressure pyroelectric ionization source (APPIS), along with applications that include detection of simulants for chemical nerve agents. It is found that ionization by APPIS occurs in the gas-phase. As the crystal is thermally cycled over a narrow temperature range, electrical discharges near the surface of the crystal produce energetic species which, through reactions with atmospheric molecules, result in reactant ions such as protonated water clusters or clusters of hydroxide and water. Reactant ions can be observed directly in the mass spectrometer. These go on to react with trace neutrals via proton transfer reactions to produce the ions observed in mass spectra, which are usually singly protonated or deprotonated species. Further implicating gas-phase ionization, observed product distributions are highly dependent on the composition of ambient gases, especially the concentration of water vapor and oxygen surrounding the source. For example, basic species such as triethylamine are observed as singly protonated cations at a water partial pressure of 10 torr. At a water pressure of 4 torr, reactive oxygen species are formed and lead to observation of protonated amine oxides. The ability of the APPIS source to detect basic molecules with high proton affinities makes it highly suited for the detection of chemical nerve agents. We demonstrate this application using simulants corresponding to VX and GA (Tabun). With the present source configuration pyridine is detected readily at a concentration of 4 ppm, indicating ultimate sensitivity in the high ppb range.


ieee aerospace conference | 2015

The Mass Analyzer for Real-time Investigation of Neutrals at Europa (MARINE)

Murray Darrach; Stojan M. Madzunkov; Rembrandt Schaefer; Dragan Nikolić; Jurij Simcic; Richard Kidd; Evan L. Neidholdt; Marcin Pilinski; Andres Jaramillo-Botero; Kenneth A. Farley

Presented herein is the progress on developing a new mass analyzer for analysis of the exospheres of planets, moons, and primitive bodies, such as found at Europa or Enceladus. Europa, one of Jupiters four Galilean moons, may have a subsurface ocean plausibly containing the key ingredients for life as well as sources of chemical energy. Clues to the composition and chemical state of Europas ocean can be found both on Europas icy surface and in its tenuous atmosphere. Given the high scientific priority of assessing the habitability of Europas ocean, the Europa Clipper notional payload includes a Neutral Mass Spectrometer whose purpose is to characterize the composition of ejected surface products during a series of flyby investigations. The Mass Analyzer for Real-time Investigation of Neutrals at Europa (MARINE) is capable of measuring the abundances of neutral particle species in Europas exosphere including H2O, O2, CO2, and SO2, and determining their number density profiles at per-second sampling rates as a function of altitude above Europas surface. MARINE will either detect tracers of potential subsurface biological activity in Europas exosphere, or place upper limits on their surface abundances. It exceeds all requirements for the proposed investigations with margins ranging from 100 to 1000%, while remaining fully compatible with spacecraft accommodation constraints for mass, power, data volume, and field-of-view.


ieee aerospace conference | 2012

In situ geochronology as a mission-enabling technology

Max Coleman; Michael H. Hecht; Joel A. Hurowitz; Evan L. Neidholdt; James Polk; Mahadeva P. Sinha; Wolfgang Sturhahn; Wayne Zimmerman

Although there are excellent estimates of ages of terrains on Mars from crater counting, even a few absolute ages would serve to validate the calibration. Results with uncertainties, although much larger than those that could be achieved in labs on Earth, would be extremely valuable. While there are other possibilities for in situ geochronology instruments, we describe here two alternative technologies, being developed in JPL. There are two common features of both. The first is analysis by means of miniature mass spectrometer. The second is use of laser sampling to reduce or avoid sample handling, preparation and pre-treatment and equally importantly, to allow analysis of individual, texturally resolved minerals in coarse-grained rocks. This textural resolution will aid in selection of grains more or less enriched in the relevant elements and allow construction of isochrons for more precise dating. Either of these instruments could enable missions to Mars and other planetary bodies.


Analytical Chemistry | 2007

Compact Ambient Pressure Pyroelectric Ion Source for Mass Spectrometry

Evan L. Neidholdt; J. L. Beauchamp


Journal of the American Chemical Society | 2009

Miniaturization and Mass Spectrometry Miniaturization and Mass Spectrometry . Edited by Séverine Le Gac and Albert van der Berg (University of Twente, The Netherlands). Royal Society of Chemistry: Cambridge. 2009. xvi+316 pp.

Evan L. Neidholdt


Archive | 2011

159. ISBN 978-0-85404-129-9 .

Nicholas A. Brunelli; Konstantinos P. Giapis; J. L. Beauchamp; Evan L. Neidholdt

Collaboration


Dive into the Evan L. Neidholdt's collaboration.

Top Co-Authors

Avatar

J. L. Beauchamp

California Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Mahadeva P. Sinha

California Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Michael H. Hecht

California Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Wolfgang Sturhahn

California Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Kenneth A. Farley

California Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Konstantinos P. Giapis

California Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Max Coleman

California Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Nicholas A. Brunelli

Georgia Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

George R. Rossman

California Institute of Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge