Acta Oncologica | 2009

RapidArc volumetric modulated therapy planning for prostate cancer patients

Flemming Kjær-Kristoffersen; Lars Ohlhues; Joakim Medin; S. Korreman

Purpose. Recently, Varian Medical Systems have announced the introduction of a new treatment technique, RapidArc, in which dose is delivered over a single gantry rotation with dynamically variable MLC positions, dose rate and gantry speed. At Rigshospitalet, the RapidArc technique was brought into clinical practice in May 2008 for treatment of prostate cancer patients. We report here our experiences with performing treatment planning using the Eclipse RapidArc optimization software for this patient group. Material and methods. A stand-alone installation of Eclipse 8.5 with RapidArc optimization capability was performed at Rigshospitalet. Patient data for 8 prostate cancer patients were imported, most of whom were previously treated at Rigshospitalet using IMRT. Three of the patients were treated at Rigshospitalet using the RapidArc technique. Treatment plans were optimized using objectives as given by standard guidelines for clinical treatment planning. RapidArc plans were compared to the IMRT plans by which the patients were actually treated or in the three cases treated with the RapidArc technique to IMRT plans achieved using standard guidelines. Comparison was done with respect to target coverage, doses to rectum and bladder, over-all maximum dose and number of monitor units. Results. Overall, the RapidArc treatment plans gave better or equal sparing of the organs at risk than the IMRT treatment plans. The number of monitor units was lower in most cases, by up to approximately 75%. However, the target dose homogeneity was not as high as for IMRT. The low-dose bath was larger than for IMRT. Conclusion. RapidArc optimization is very promising, especially regarding the potential of reducing the number of monitor units, while providing good sparing of organs at risk. Some improvement is still warranted with respect to achieving high target dose homogeneity.


Physics in Medicine and Biology | 2004

Real-time optical-fibre luminescence dosimetry for radiotherapy: physical characteristics and applications in photon beams

Marianne C. Aznar; Claus E. Andersen; L. Bøtter-Jensen; Sven Bäck; Sören Mattsson; Flemming Kjær-Kristoffersen; Joakim Medin

A new optical-fibre radiation dosimeter system, based on radioluminescence and optically stimulated luminescence from carbon-doped aluminium oxide, was developed and tested in clinical photon beams. This prototype offers several features, such as a small detector (1 x 1 x 2 mm3), high sensitivity, real-time read-out and the ability to measure both dose rate and absorbed dose. The measurements describing reproducibility and output dependence on dose rate, field size and energy all had standard deviations smaller than 1%. The signal variation with the angle of incidence was smaller than 2% (1 SD). Measurements performed in clinical situations suggest the potential of using this real-time system for in vivo dosimetry in radiotherapy.


Acta Oncologica | 2009

Dosimetric verification of RapidArc treatment delivery

S. Korreman; Joakim Medin; Flemming Kjær-Kristoffersen

Purpose. Recently, Varian Medical Systems have announced the introduction of a new treatment technique, in which dose is delivered over a single gantry rotation with variable MLC positions, dose rate and gantry speed. In February 2008, a preclinical installation of the RapidArc™ beam delivery approach was carried out on a Varian Clinac at Rigshospitalet in Copenhagen. The purpose of the installation was to perform measurements to verify the correctness of doses delivered with the RapidArc technique. In May 2008, the clinical release of the RapidArc application was installed at Rigshospitalet. Methods and materials. Nine treatment plans were generated in the Eclipse version 8.5 including the RapidArc optimizer for H&N and prostate cases. The plans were delivered to the Scandidos Delta4® cylindrical diode array phantom. First, the measured dose distributions were compared with the calculated doses. All plans were then delivered several times to verify consistency of the delivery. Gamma analysis was used to verify the correspondence between dose distributions. The temporal resolution of the delivery was analysed by investigating the arc segments between control points separately. Results. Overall, good agreement was observed between measured and calculated doses in most cases with gamma values above 1 in >95% of measured points. The reproducibility of delivery was also very high. Gamma analysis between two consecutive runs of the same delivery plan generally showed gamma values above 1 in none of the measured points, and dose deviation less than 1%. Temporal analysis showed small discrepancies between doses delivered between control points (∼2 degrees of the rotation) in consecutive runs of a plan, however these were cancelled out in the accumulated dose. Conclusion. The delivery of RapidArc beam delivery has been verified to correspond well with calculated dose distributions for a number of different cases. The delivery was very reproducible, and was carried out with high stability of the accelerator performance.


Radiotherapy and Oncology | 2009

Pulmonary toxicity following IMRT after extrapleural pneumonectomy for malignant pleural mesothelioma

Claus A. Kristensen; Trine Juhler Nøttrup; Anne Kiil Berthelsen; Flemming Kjær-Kristoffersen; Jesper Ravn; Jens Benn Sørensen; S.A. Engelholm

BACKGROUND AND PURPOSE The combination of chemotherapy, surgery, and radiotherapy has improved the prognosis for patients with malignant pleural mesothelioma (MPM). Intensity-modulated radiotherapy (IMRT) has allowed for an increase in dose to the pleural cavity and a reduction in radiation doses to organs at risk. The present study reports and analyses the incidence of fatal pulmonary toxicity in patients treated at Rigshospitalet, Copenhagen. MATERIALS AND METHODS Twenty-six patients were treated with induction chemotherapy followed by extrapleural pneumonectomy and IMRT between April 2003 and April 2006. The entire preoperative pleural surface area was treated to 50 Gy and areas with residual disease or close surgical margins were treated to 60 Gy in 30 fractions. RESULTS The main toxicities were nausea, vomiting, esophagitis, dyspnea, and thrombocytopenia. One patient died from an intracranial hemorrhage during severe thrombocytopenia. Four patients (15%) experienced grade 5 lung toxicity, i.e. pneumonitis 19-40 days after the completion of radiotherapy. Patients with pneumonitis had a significantly larger lung volume fraction receiving 10 Gy or more (V10) (median: 60.3%, range 56.4-83.2%) compared to patients without pneumonitis (median: 52.6%, range: 25.6-80.3%) (p=0.02). Mean lung dose (MLD) was also significantly higher in patients who developed pneumonitis (median 13.9 Gy, range: 13.6-14.2 Gy) than in patients who did not (median=12.4 Gy, range: 8.4-15.4 Gy) (p=0.04). CONCLUSIONS Significant differences in MLD and V10 for patients with fatal pulmonary toxicity compared to patients without fatal lung toxicity have been demonstrated. Based on the presented data local lung dose constraints have been modified in order to avoid unacceptable toxicity.


Physics in Medicine and Biology | 2010

RapidArc treatment verification in 3D using polymer gel dosimetry and Monte Carlo simulation

Sofie Ceberg; Isabelle Gagne; Helen Gustafsson; Jonas Bengtsson Scherman; S. Korreman; Flemming Kjær-Kristoffersen; Michelle Hilts; Sven Bäck

The aim of this study was to verify the advanced inhomogeneous dose distribution produced by a volumetric arc therapy technique (RapidArc) using 3D gel measurements and Monte Carlo (MC) simulations. The TPS (treatment planning system)-calculated dose distribution was compared with gel measurements and MC simulations, thus investigating any discrepancy between the planned dose delivery and the actual delivery. Additionally, the reproducibility of the delivery was investigated using repeated gel measurements. A prostate treatment plan was delivered to a 1.3 liter nPAG gel phantom using one single arc rotation and a target dose of 3.3 Gy. Magnetic resonance imaging of the gel was carried out using a 1.5 T scanner. The MC dose distributions were calculated using the VIMC-Arc code. The relative absorbed dose differences were calculated voxel-by-voxel, within the volume enclosed by the 90% isodose surface (VOI(90)), for the TPS versus gel and TPS versus MC. The differences between the verification methods, MC versus gel, and between two repeated gel measurements were investigated in the same way. For all volume comparisons, the mean value was within 1% and the standard deviation of the differences was within 2.5% (1SD). A 3D gamma analysis between the dose matrices were carried out using gamma criteria 3%/3 mm and 5%/5 mm (% dose difference and mm distance to agreement) within the volume enclosed by the 50% isodose surface (VOI(50)) and the 90% isodose surface (VOI(90)), respectively. All comparisons resulted in very high pass rates. More than 95% of the TPS points were within 3%/3 mm of both the gel measurement and MC simulation, both inside VOI(50) and VOI(90). Additionally, the repeated gel measurements showed excellent consistency, indicating reproducible delivery. Using MC simulations and gel measurements, this verification study successfully demonstrated that the RapidArc plan was both accurately calculated and delivered as planned.


Acta Oncologica | 2007

Nasopharyngeal carcinoma. Treatment planning with IMRT and 3D conformal radiotherapy

Claus A. Kristensen; Flemming Kjær-Kristoffersen; Wendy Sapru; Anne Kiil Berthelsen; Annika Loft; Lena Specht

The study was undertaken in order to compare dose plans for intensity-modulated radiotherapy (IMRT) with 3D conformal radiotherapy (3D-CRT) dose plans in patients with nasopharyngeal carcinoma (NPC). Clinical data from 20 consecutive patients treated with IMRT are presented. For 11 patients 3D-CRT plans were made and compared to the IMRT plans with respect to doses to the planning target volumes (PTVs) and to organs at risk (OARs). For comparison of the conformation of dose to defined target volumes the conformity index (CI) was used. Target volume coverage and critical organ protection were significantly improved with IMRT compared to 3D-CRT. One-year loco-regional control, distant metastasis-free survival, and overall survival were 79%, 72%, and 80%. Two patients have had recurrence in the clinical target volume (CTV) only and seven patients have relapsed in distant organs and/or in head-and-neck areas outside the target areas. The study confirms that IMRT is superior to 3D-CRT in the treatment of NPC. As locoregional control of NPC improves we are facing an increasing number of recurrences outside the irradiated area.


Radiotherapy and Oncology | 2008

Local control and survival in patients with soft tissue sarcomas treated with limb sparing surgery in combination with interstitial brachytherapy and external radiation

Aida Muhic; Dorrit Hovgaard; Michael Mørk Petersen; Søren Daugaard; Birthe Højlund Bech; Henrik Roed; Flemming Kjær-Kristoffersen; Svend Aage Engelholm

PURPOSE The purpose of this study was to evaluate local control, survival and complication rate after treatment of soft tissue sarcoma (STS) with limb-sparing surgery combined with pulsed-dose rate (PDR) interstitial brachytherapy (BRT) and external beam radiotherapy (EBRT). PATIENTS AND METHODS A retrospective review of 39 adult patients (female/male=25/14, mean age 51(range 21-78) years) with STS who underwent primary limb-sparing surgery combined with PDR BRT (20Gy) and additional post-operative EBRT (50Gy) during the years 1995-2004. RESULTS Five patients developed local recurrence after a mean follow-up of 3.4 (1.5-5.9) years. The probability of local recurrence free 5 years survival was 83%. At the time of follow-up 10 patients had died (mean follow-up 2.3 (0.8-7.1) years) and 29 patients were still alive (mean follow-up 5.9 (2.1-11.2) years). The overall 5-year survival rate was 76%. Nineteen (49%) patients suffered from some degree of decreased force or function of the affected extremity, 16 (41%) suffered from oedema, 12 (31%) had persistent pain, 8 (21%) suffered from wound complications, and in 4 (10%) of these patients plastic surgery were required. CONCLUSION Limb sparing surgery, combined with PDR BRT and EBRT can result in good local control in patients with soft tissue sarcomas. BRT is an effective modality with good cosmetic results and acceptable toxicity.


Acta Oncologica | 2008

Post-mastectomy radiotherapy in Denmark: From 2D to 3D treatment planning guidelines of The Danish Breast Cancer Cooperative Group

Mette S. Thomsen; Martin Berg; Hanne Melgaard Nielsen; Aanders N. Pedersen; Marie Overgaard; Marianne Ewertz; Thomas Block; Hans J. Brodersen; Claudio Caldera; Erik Jakobsen; Claus Kamby; Flemming Kjær-Kristoffersen; Dorte Klitgaard; Mette Møller Nielsen; Lars Stenbygaard; S.J. Zimmermann; Cai Grau

This paper describes the procedure of changing from 2D to 3D treatment planning guidelines for post-mastectomy radiotherapy in Denmark. The aim of introducing 3D planning for post-mastectomy radiotherapy was to optimize the target coverage and minimize the dose to the normal tissues. Initially, it was investigated whether it was possible to find a treatment technique alternative to the one recommended by the Danish Breast Cancer Cooperative Group (DBCG). A dosimetric comparison of a combined photon/electron 3-field technique (3F) and a partial wide tangent technique (PWT) was carried out on individual planning CT-scans from seven patients selected to represent a wide range of sizes and shapes of chest walls. The heart dose was lower for PWT than for 3F, however, for both techniques the dose was within the accepted constraints. The lung dose was higher but acceptable for six of the seven patients with PWT. The dose to the internal mammary nodes (IMN) was not satisfactory for five of the seven patients for 3F, whereas only two of the seven patients had a minimum dose lower than 95% of the prescribed dose with PWT. Finally, the dose to the contralateral breast was increased when using PWT compared to 3F. It was concluded that PWT was an appropriate choice of technique for future radiation treatment of post-mastectomy patients. A working group was formed and guidelines for 3D planning were developed during a series of workshops where radiation oncologists and physicists from all radiotherapy centres participated. This work also included a definition of the tissue structures needed to be outlined on the planning CT-scan. The work was initiated in 2003 and the guidelines were approved by the DBCG Radiotherapy Committee in 2006. The first of January 2007 the 3D guidelines had been fully implemented in five of the seven radiotherapy centres.


Physics in Medicine and Biology | 2011

A closer look at RapidArc® radiosurgery plans using very small fields

L.S. Fog; Jens F B Rasmussen; Marianne C. Aznar; Flemming Kjær-Kristoffersen; Ivan R. Vogelius; Svend Aage Engelholm; J.P. Bangsgaard

RapidArc® has become the treatment of choice for an increasing number of treatment sites in many clinics. The extensive use of multiple subfields in RapidArc® treatments presents unique challenges, especially for small targets treated in few fractions. In this work, very small static fields and subsequently RapidArc® and conventional plans for two targets (0.4 and 9.9 cm(3)) were investigated. Doses from static fields 1-4 MLC leaves (0.25-1.00 cm) wide, and larger fields with 1-4 MLC leaves closed in their centres, were measured using the portal dosimeter-based QA system EPIQA (v 1.3) and gafchromic film. RapidArc and conventional plans for two tumours were then measured using EPIQA, gafchromic EBT2 film and the phantom-based QA system Delta4. Eclipse 8.6 and 8.9, grid spacings of 1.25 and 2.50 mm and a Varian HD linac were used. For static fields one MLC leaf wide, the dose was underestimated by Eclipse by as much as 53% (v 8.6, 2.5 mm grid). Eclipse underestimated the dose downstream from a few MLC leaves closed in the centre of a large MLC field by as much as 30%. Eclipse consistently overestimated the width of the penumbra by about 100%. For the conventional plans, there was good agreement between the calculated and measured dose for the 9.9 cm(3) PTV, but a 10% underdose was observed for the 0.4 cm(3) PTV. For the RapidArc® plans, the measured dose for the 9.9 cm(3) PTV was in good agreement with the calculated one. However, for the 0.4 cm(3) PTV about 10% overdosing was detected (Eclipse v 8.6, 2.5 mm grid spacing). EPIQA data indicated that the measured dose profiles were overmodulated compared to the calculated one. The use of small subfields, typically a few MLC leaves wide, or larger fields with one or a few MLC leaves closed in its centre can result in significant errors in the dose calculation. The detector systems used vary in their ability to detect the discrepancies. Using a smaller grid size and newer version of Eclipse reduces the discrepancies observed in this work but does not eliminate them.


Medical Dosimetry | 2009

IMRT in a Pregnant Patient: How to Reduce the Fetal Dose?

M. Josipovic; Håkan Nyström; Flemming Kjær-Kristoffersen

The purpose of our study was to find a solution for fetal dose reduction during head-and-neck intensity modulated radiation therapy (IMRT) of a pregnant patient. The first step was optimization of the IMRT treatment plan with as few monitor units (MUs) as possible, while maintaining an acceptable dose distribution. The peripheral dose originating from the final IMRT plan was measured at distances reaching from the most proximal to the most distal fetal position, along the accelerators longitudinal axis, using an anthropomorphic phantom extended with water-equivalent plastic. The measured peripheral dose was divided into leakage, and internal and collimator scatter, to find the degree to which each component influences the peripheral dose to build an appropriate shield. Collimator scatter was the greatest contributor to the peripheral dose throughout the range of the growing fetus. A shield was built and placed beneath the accelerator head, extending caudally from the field edge, to function as an extra collimator jaw. This shield reduced the fetal dose by a factor of 3.5. The peripheral dose components were also measured for simple rectangular fields and also here the collimator scatter was the greatest contributor to the peripheral dose. Therefore, the shielding used for the IMRT treatment of our patient could also be used when shielding in conventional radiotherapy. It is important for a radiation therapy department to be prepared for treatment of a pregnant patient to shield the fetus efficiently.

Collaboration


Dive into the Flemming Kjær-Kristoffersen's collaboration.

Top Co-Authors

Avatar

S. Korreman

Copenhagen University Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

S.A. Engelholm

Copenhagen University Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Claus E. Andersen

Technical University of Denmark

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Lena Specht

University of Copenhagen

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge