Physics in Medicine and Biology | 2004

Real-time optical-fibre luminescence dosimetry for radiotherapy: physical characteristics and applications in photon beams

Marianne C. Aznar; Claus E. Andersen; L. Bøtter-Jensen; Sven Bäck; Sören Mattsson; Flemming Kjær-Kristoffersen; Joakim Medin

A new optical-fibre radiation dosimeter system, based on radioluminescence and optically stimulated luminescence from carbon-doped aluminium oxide, was developed and tested in clinical photon beams. This prototype offers several features, such as a small detector (1 x 1 x 2 mm3), high sensitivity, real-time read-out and the ability to measure both dose rate and absorbed dose. The measurements describing reproducibility and output dependence on dose rate, field size and energy all had standard deviations smaller than 1%. The signal variation with the angle of incidence was smaller than 2% (1 SD). Measurements performed in clinical situations suggest the potential of using this real-time system for in vivo dosimetry in radiotherapy.


Physics in Medicine and Biology | 2004

Linear energy transfer dependence of a normoxic polymer gel dosimeter investigated using proton beam absorbed dose measurements

Helen Gustavsson; Sven Bäck; Joakim Medin; Erik Grusell; Lars E. Olsson

Three-dimensional dosimetry with good spatial resolution can be performed using polymer gel dosimetry, which has been investigated for dosimetry of different types of particles. However, there are only sparse data concerning the influence of the linear energy transfer (LET) properties of the radiation on the gel absorbed dose response. The purpose of this study was to investigate possible LET dependence for a polymer gel dosimeter using proton beam absorbed dose measurements. Polymer gel containing the antioxidant tetrakis(hydroxymethyl)phosphonium (THP) was irradiated with 133 MeV monoenergetic protons, and the gel absorbed dose response was evaluated using MRI. The LET distribution for a monoenergetic proton beam was calculated as a function of depth using the Monte Carlo code PETRA. There was a steep increase in the Monte Carlo calculated LET starting at the depth corresponding to the front edge of the Bragg peak. This increase was closely followed by a decrease in the relative detector sensitivity (Srel = Dgel/Ddiode), indicating that the response of the polymer gel detector was dependent on LET. The relative sensitivity was 0.8 at the Bragg peak, and reached its minimum value at the end of the proton range. No significant effects in the detector response were observed for LET < 4.9 keV microm(-1), thus indicating that the behaviour of the polymer gel dosimeter would not be altered for the range of LET values expected in the case of photons or electrons in a clinical range of energies.


Physics in Medicine and Biology | 2005

The influence of RBE variations in a clinical proton treatment plan for a hypopharynx cancer

Nina Tilly; Jonas Johansson; Ulf Isacsson; Joakim Medin; Erik Blomquist; Erik Grusell; Bengt Glimelius

Currently, most clinical range-modulated proton beams are assumed to have a fixed overall relative biological effectiveness (RBE) of 1.1. However, it is well known that the RBE increases with depth in the spread-out Bragg peak (SOBP) and becomes about 10% higher than mid-SOBP RBE at 2 mm from the distal edge (Paganetti 2003 Technol. Cancer Res. Treat. 2 413-26) and can reach values of 1.3-1.4 in vitro at the distal edge (Robertson et al 1975 Cancer 35 1664-77, Courdi et al 1994 Br. J. Radiol. 67 800-4). We present a fast method for applying a variable RBE correction with linear energy transfer (LET) dependent tissue-specific parameters based on the alpharef/betaref ratios suitable for implementation in a treatment planning system. The influence of applying this variable RBE correction on a clinical multiple beam proton dose plan is presented here. The treatment plan is evaluated by RBE weighted dose volume histograms (DVHs) and the calculation of tumour control probability (TCP) and normal tissue complication probability (NTCP) values. The variable RBE correction yields DVHs for the clinical target volumes (CTVs), a primary advanced hypopharynx cancer and subclinical disease in the lymph nodes, that are slightly higher than those achieved by multiplying the absorbed dose with RBE=1.1. Although, more importantly, the RBE weighted DVH for an organ at risk, the spinal cord is considerably increased for the variable RBE. As the spinal cord in this particular case is located 8 mm behind the planning target volume (PTV) and hence receives only low total doses, the NTCP values are zero in spite of the significant increase in the RBE weighted DVHs for the variable RBE. However, high NTCP values for the non-target normal tissue were obtained when applying the variable RBE correction. As RBE variations tend to be smaller for in vivo systems, this study-based on in vitro data since human tissue RBE values are scarce and have large uncertainties-can be interpreted as showing the upper limits of the possible effects of utilizing a variable RBE correction. In conclusion, the results obtained here still indicate a significant difference in introducing a variable RBE compared to applying a generic RBE of 1.1, suggesting it is worth considering such a correction in clinical proton therapy planning, especially when risk organs are located immediately behind the target volume.


Physics in Medicine and Biology | 1999

Ferrous sulphate gel dosimetry and MRI for proton beam dose measurements.

Sven Bäck; Joakim Medin; Peter Magnusson; Peter Olsson; Erik Grusell; Lars E. Olsson

Ferrous sulphate gel dosimetry has the potential for measurement of absorbed dose distributions in proton therapy. The chemical properties of the gel are altered according to the radiation dose and these changes can be evaluated in three dimensions using MRI. The purpose of this work was to investigate the properties of a ferrous gel used with clinical proton beams. The gel was irradiated with both monoenergetic and range-modulated proton beams. It was then evaluated using MRI. The depth dose by means of the 1/T1 distribution was studied and compared with data from a plane-parallel plate ionization chamber. 1/T1 was shown to be proportional to the dose at a mean proton energy of approximately 90 MeV. The dose response was no different from that obtained using photon beams. However, on normalization at the entrance, the relative 1/T1 at the Bragg peak was 15-20% lower than the corresponding ionization chamber data for the monoenergetic proton beam. Better agreement was found for the modulated beam, but with significant differences close to the distal edge of the 1/T1 distribution. The change in sensitivity with depth was explained by means of a linear energy transfer dependence. This property was further studied using Monte Carlo methods.


Physics in Medicine and Biology | 2000

General characteristics of the use of silicon diode detectors for clinical dosimetry in proton beams

Erik Grusell; Joakim Medin

The properties of silicon diode detectors, used for dosimetry in clinical proton beams, were investigated with special regard to the measurement of relative dose distributions in water. Different types of silicon diode detector were studied, and the resulting distributions of detector signal versus depth in the water phantom were compared with the corresponding distributions obtained with a plane-parallel NACP ionization chamber. The measurements were performed in a proton beam with an initial energy of 173 MeV. It is shown that the Hi-p silicon detector gives a signal which is proportional to the ionization density in the silicon crystal in all parts of the Bragg curve, and for all levels of accumulated dose to the detector. This is in contrast to detectors based on n-type silicon, or on low resistivity p-type silicon. After pre-irradiation, these latter detectors show a stopping-power dependent recombination, yielding an increase in the detector signal per unit dose with increasing LET. This effect leads to an over-response in the Bragg peak, which increases gradually with the accumulated detector dose. Using the Hi-p silicon diode detector, the depth ionization distribution was found to be equal to the distribution obtained with the plane-parallel NACP ionization chamber at all pre-irradiation levels, within the experimental accuracy. This implies that the quotient between the ionization in the detector and the absorbed dose to the surrounding water is equal for these detectors.


Radiotherapy and Oncology | 1996

Proton dosimetry intercomparison

Stanislav Vatnitsky; J Siebers; Daniel W. Miller; Michael F. Moyers; M Schaefer; D. T. L. Jones; Stefaan Vynckier; Y Hayakawa; S Delacroix; Ulf Isacsson; Joakim Medin; A Kacperek; Antony Lomax; Adolf Coray; H Kluge; J Heese; Lynn Verhey; Inder K. Daftari; K Gall; G Lam; T Beck; Günther H. Hartmann

BACKGROUND AND PURPOSE Methods for determining absorbed dose in clinical proton beams are based on dosimetry protocols provided by the AAPM and the ECHED. Both groups recommend the use of air-filled ionization chambers calibrated in terms of exposure or air kerma in a 60Co beam when a calorimeter or Faraday cup dosimeter is not available. The set of input data used in the AAPM and the ECHED protocols, especially proton stopping powers and w-value is different. In order to verify inter-institutional uniformity of proton beam calibration, the AAPM and the ECHED recommend periodic dosimetry intercomparisons. In this paper we report the results of an international proton dosimetry intercomparison which was held at Loma Linda University Medical Center. The goal of the intercomparison was two-fold: first, to estimate the consistency of absorbed dose delivered to patients among the participating facilities, and second, to evaluate the differences in absorbed dose determination due to differences in 60Co-based ionization chamber calibration protocols. MATERIALS AND METHODS Thirteen institutions participated in an international proton dosimetry intercomparison. The measurements were performed in a 15-cm square field at a depth of 10 cm in both an unmodulated beam (nominal accelerator energy of 250 MeV) and a 6-cm modulated beam (nominal accelerator energy of 155 MeV), and also in a circular field of diameter 2.6 cm at a depth of 1.14 cm in a beam with 2.4 cm modulation (nominal accelerator energy of 100 MeV). RESULTS The results of the intercomparison have shown that using ionization chambers with 60Co calibration factors traceable to standard laboratories, and institution-specific conversion factors and dose protocols, the absorbed dose specified to the patient would fall within 3% of the mean value. A single measurement using an ionization chamber with a proton chamber factor determined with a Faraday cup calibration differed from the mean by 8%. CONCLUSION The adoption of a single ionization chamber dosimetry protocol and uniform conversion factors will establish agreement on proton absorbed dose to approximately 1.5%, consistent with that which has been observed in high-energy photon and electron dosimetry.


Physics in Medicine and Biology | 2006

Experimental determination of beam quality factors, kQ, for two types of Farmer chamber in a 10 MV photon and a 175 MeV proton beam

Joakim Medin; C. K. Ross; Norman V. Klassen; Hugo Palmans; Erik Grusell; Jan-Erik Grindborg

Absorbed doses determined with a sealed water calorimeter operated at 4 degrees C are compared with the results obtained using ionization chambers and the IAEA TRS-398 code of practice in a 10 MV photon beam (TPR(20,10) = 0.734) and a 175 MeV proton beam (at a depth corresponding to the residual range, R(res) = 14.7 cm). Three NE 2571 and two FC65-G ionization chambers were calibrated in terms of absorbed-dose-to-water in (60)Co at the Swedish secondary standard dosimetry laboratory, directly traceable to the BIPM. In the photon beam quality, calorimetry was found to agree with ionometry within 0.3%, confirming the k(Q) values tabulated in TRS-398. In contrast, a 1.8% deviation was found in the proton beam at 6 g cm(-2) depth, suggesting that the TRS-398 tabulated k(Q) values for these two ionization chamber types are too high. Assuming no perturbation effect in the proton beam for the ionization chambers, a value for (w(air)/e)(Q) of 33.6 J C(-1) +/- 1.7% (k = 1) can be derived from these measurements. An analytical evaluation of the effect from non-elastic nuclear interactions in the ionization chamber wall indicates a perturbation effect of 0.6%. Including this estimated result in the proton beam would increase the determined (w(air)/e)(Q) value by the same amount.


Physics in Medicine and Biology | 2000

Comparison of dosimetry recommendations for clinical proton beams

Joakim Medin; Pedro Andreo; Stefaan Vynckier

The formalism and data in the two most recent dosimetry recommendations for clinical proton beams, ICRU Report 59 and the forthcoming IAEA Code of Practice, are compared. Chamber calibrations in terms of air kerma and absorbed dose to water are considered, including five different cylindrical ionization chamber types commonly used in proton beam dosimetry. The methodology for both types of calibration for ionization chambers is described in ICRU Report 59. The procedure based on air kerma calibrations is compared with an alternative formalism based on IAEA Codes of Practice (TRS-277, TRS-381), modified for proton beams. The new IAEA Code of Practice is exclusively based on calibrations in terms of absorbed dose to water and a direct comparison with ICRU Report 59 recommendations is made. Common to the two formalisms are the fundamental quantities Wair and w(air) and their atmospheric conditions of applicability. The difference in the recommended values of the ratio w(air)/Wair (protons to 60Co) is as large as 2.3%. The use of Wair and w(air) values for dry air (IAEA) and for ambient air (ICRU) is a contribution to the discrepancy, and the ICRU usage is questioned. For air kerma based chamber calibrations, ICRU Report 59 does not take into account the effect of different compositions of the build-up cap and chamber wall on the calibration beam quality. For the chamber types included in the study, this introduces discrepancies of up to 1.1%. Combined with differences in the recommended basic data, discrepancies in absorbed dose determination in proton beams of up to 2.1% are found. For the absorbed dose to water based formalism, differences in the formalism, notably the omission of perturbation factors for 60Co in ICRU 59, and data yield discrepancies in calculated kQ factors, and in absorbed dose determinations, between -1.5% and +2.6%, depending on the chamber type and the proton beam quality.


Physics in Medicine and Biology | 1995

Faraday cup dosimetry in a proton therapy beam without collimation

Erik Grusell; Ulf Isacsson; Anders Montelius; Joakim Medin

A Faraday cup in a proton beam can give an accurate measurement of the number of protons collected by the cup. It is shown that the collection efficiency with a proper design can be close to unity. To be able to calibrate an ionization chamber from such a measurement, as is recommended in some dosimetry protocols, the energy spectrum of the proton beam must be accurately known. This is normally not the case when the lateral beam extension is defined by collimators. Therefore a method for relating an ionization chamber measurement in an uncollimated beam to the total number of protons in the beam has been developed and is described together with experimental results from calibrating an ionization chamber using this method in the therapeutic beam in Uppsala. This method is applicable to ionization chambers of any shape and the accuracy is estimated to be 1.6% (1 SD).


Medical Imaging 2004: Image Perception, Observer Performance, and Technology Assessment | 2004

Comparison of two methods for evaluation of image quality of lumbar spine radiographs

Anders Tingberg; Magnus Båth; Markus Håkansson; Joakim Medin; Michael Sandborg; Gudrun Alm-Carlsson; Sören Mattsson; Lars Gunnar Månsson

To evaluate the image quality of clinical radiographs with two different methods, and to find correlations between the two methods. Based on fifteen lumbar spine radiographs, two new sets of images were created. A hybrid image set was created by adding two distributions of artificial lesions to each original image. The image quality parameters spatial resolution and noise were manipulated and a total of 210 hybrid images were created. A set of 105 disease-free images was created by applying the same combinations of spatial resolution and noise to the original images. The hybrid images were evaluated with the free-response forced error experiment (FFE) and the normal images with visual grading analysis (VGA) by nine experienced radiologists. The VGA study showed that images with low noise are preferred over images with higher noise levels. The alteration of the MTF had a limited influence on the VGA score. For the FFE study the visibility of the lesions was independent of the spatial resolution and the noise level. In this study we found no correlation between the two methods, probably because the detectability of the artificial lesions was not influenced by the manipulations of noise level and resolution. Hence, the detection of lesions in lumbar spine radiography may not be a quantum-noise limited task. The results show the strength of the VGA technique in terms of detecting small changes in the two image quality parameters. The method is more robust and has a higher statistical power than the ROC related method and could therefore, in some cases, be more suitable for use in optimization studies.

Collaboration


Dive into the Joakim Medin's collaboration.

Top Co-Authors

Avatar

Erik Grusell

Uppsala University Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Claus E. Andersen

Technical University of Denmark

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Lars Gunnar Månsson

Sahlgrenska University Hospital

View shared research outputs
Top Co-Authors

Avatar

Magnus Båth

Sahlgrenska University Hospital

View shared research outputs
Top Co-Authors

Avatar

Markus Håkansson

Sahlgrenska University Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Pedro Andreo

International Atomic Energy Agency

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge