Journal of Biomechanics | 2010
Ines Kutzner; Bernd Heinlein; Friedmar Graichen; Alwina Bender; A. Rohlmann; Andreas Halder; Alexander Beier; G. Bergmann
Detailed knowledge about loading of the knee joint is essential for preclinical testing of implants, validation of musculoskeletal models and biomechanical understanding of the knee joint. The contact forces and moments acting on the tibial component were therefore measured in 5 subjects in vivo by an instrumented knee implant during various activities of daily living. Average peak resultant forces, in percent of body weight, were highest during stair descending (346% BW), followed by stair ascending (316% BW), level walking (261% BW), one legged stance (259% BW), knee bending (253% BW), standing up (246% BW), sitting down (225% BW) and two legged stance (107% BW). Peak shear forces were about 10-20 times smaller than the axial force. Resultant forces acted almost vertically on the tibial plateau even during high flexion. Highest moments acted in the frontal plane with a typical peak to peak range -2.91% BWm (adduction moment) to 1.61% BWm (abduction moment) throughout all activities. Peak flexion/extension moments ranged between -0.44% BWm (extension moment) and 3.16% BWm (flexion moment). Peak external/internal torques lay between -1.1% BWm (internal torque) and 0.53% BWm (external torque). The knee joint is highly loaded during daily life. In general, resultant contact forces during dynamic activities were lower than the ones predicted by many mathematical models, but lay in a similar range as measured in vivo by others. Some of the observed load components were much higher than those currently applied when testing knee implants.
PLOS ONE | 2014
G. Bergmann; Alwina Bender; Friedmar Graichen; Joern Dymke; A. Rohlmann; Adam Trepczynski; Markus O. Heller; Ines Kutzner
The loads acting in knee joints must be known for improving joint replacement, surgical procedures, physiotherapy, biomechanical computer simulations, and to advise patients with osteoarthritis or fractures about what activities to avoid. Such data would also allow verification of test standards for knee implants. This work analyzes data from 8 subjects with instrumented knee implants, which allowed measuring the contact forces and moments acting in the joint. The implants were powered inductively and the loads transmitted at radio frequency. The time courses of forces and moments during walking, stair climbing, and 6 more activities were averaged for subjects with I) average body weight and average load levels and II) high body weight and high load levels. During all investigated activities except jogging, the high force levels reached 3,372–4,218N. During slow jogging, they were up to 5,165N. The peak torque around the implant stem during walking was 10.5 Nm, which was higher than during all other activities including jogging. The transverse forces and the moments varied greatly between the subjects, especially during non-cyclic activities. The high load levels measured were mostly above those defined in the wear test ISO 14243. The loads defined in the ISO test standard should be adapted to the levels reported here. The new data will allow realistic investigations and improvements of joint replacement, surgical procedures for tendon repair, treatment of fractures, and others. Computer models of the load conditions in the lower extremities will become more realistic if the new data is used as a gold standard. However, due to the extreme individual variations of some load components, even the reported average load profiles can most likely not explain every failure of an implant or a surgical procedure.
PLOS ONE | 2013
Ines Kutzner; Adam Trepczynski; Markus O. Heller; G. Bergmann
The external knee adduction moment is considered a surrogate measure for the medial tibiofemoral contact force and is commonly used to quantify the load reducing effect of orthopedic interventions. However, only limited and controversial data exist about the correlation between adduction moment and medial force. The objective of this study was to examine whether the adduction moment is indeed a strong predictor for the medial force by determining their correlation during gait. Instrumented knee implants with telemetric data transmission were used to measure tibiofemoral contact forces in nine subjects. Gait analyses were performed simultaneously to the joint load measurements. Skeletal kinematics, as well as the ground reaction forces and inertial parameters, were used as inputs in an inverse dynamics approach to calculate the external knee adduction moment. Linear regression analysis was used to analyze the correlation between adduction moment and medial force for the whole stance phase and separately for the early and late stance phase. Whereas only moderate correlations between adduction moment and medial force were observed throughout the whole stance phase (R2 = 0.56) and during the late stance phase (R2 = 0.51), a high correlation was observed at the early stance phase (R2 = 0.76). Furthermore, the adduction moment was highly correlated to the medial force ratio throughout the whole stance phase (R2 = 0.75). These results suggest that the adduction moment is a surrogate measure, well-suited to predicting the medial force ratio throughout the whole stance phase or medial force during the early stance phase. However, particularly during the late stance phase, moderate correlations and high inter-individual variations revealed that the predictive value of the adduction moment is limited. Further analyses are necessary to examine whether a combination of other kinematic, kinetic or neuromuscular factors may lead to a more reliable prediction of the force magnitude.
Journal of Biomechanics | 2011
Ines Kutzner; Steffen Küther; Bernd Heinlein; Jörn Dymke; Alwina Bender; Andreas Halder; G. Bergmann
Knee osteoarthritis occurs predominately at the medial compartment. To unload the affected compartment, valgus braces are used which induce an additional valgus moment in order to shift the load more laterally. Until now the biomechanical effect of braces was mainly evaluated by measuring changes in external knee adduction moments. The aim of this study was to investigate if and to which extent the medial compartment load is reduced in vivo when wearing valgus braces. Six components of joint contact load were measured in vivo in three subjects, using instrumented, telemeterized knee implants. From the forces and moments the medio-lateral force distribution was calculated. Two braces, MOS Genu (Bauerfeind AG) and Genu Arthro (Otto Bock) were investigated in neutral, 4° and 8° valgus adjustment during walking, stair ascending and descending. During walking with the MOS brace in 4°/8° valgus adjustment, medial forces were reduced by 24%/30% on average at terminal stance. During walking with the GA in the 8° valgus position, medial forces were reduced by only 7%. During stair ascending/descending significant reductions of 26%/24% were only observed with the MOS (8°). The load reducing ability of the two investigated valgus braces was confirmed in three subjects. However, the load reduction depends on the brace stiffness and its valgus adjustment and varies strongly inter-individually. Valgus adjustments of 8° might, especially with the MOS brace, not be tolerated by patients for a long time. Medial load reductions of more than 25% can therefore probably not be expected in clinical practise.
Journal of Bone and Joint Surgery, American Volume | 2012
Andreas Halder; Ines Kutzner; Friedmar Graichen; Bernd Heinlein; Alexander Beier; G. Bergmann
BACKGROUND Malalignment after total knee replacement could cause overloading of the implant bearing as well as of the bone itself, leading to osteolysis and early loosening. To quantify the stresses the implant has to withstand and to define a safe zone of limb alignment, the total contact forces as well as their mediolateral distribution have to be determined. Analytical gait data and mathematical models have been used for this purpose. We performed this study to determine in vivo loads of five patients after implantation of an instrumented tibial baseplate. METHODS Five patients with osteoarthritis of the knee received total knee replacement. The tibial component was instrumented with strain gauges for the measurement of three forces and three moments. The signals from the gauges were transferred telemetrically to an external receiver. At twelve months after surgery, postoperative measurements were obtained with the patients walking at a self-selected comfortable speed across a level walkway. Peak axial and medial forces of fifteen to twenty gait cycles were averaged and reported as a percent of individual body weight. RESULTS During the stance phase of the gait cycle, two maxima of the axial force occurred. Typical values were 215% of body weight at the first peak and 266% of body weight at the second peak. The medial load share was typically 73% at the first axial force peak and 65% at the second axial force peak. Analysis of inter-individual variations revealed a linear correlation with limb alignment. A deviation of 1° varus from neutral alignment increased the medial load share by 5%. CONCLUSIONS Consistent with the results of previous studies, we found that the force transferred by the medial compartment was usually greater than that transferred by the lateral compartment. Concerning the design of total knee replacements, an asymmetric tibial component with a larger medial contact area could possibly reduce peak contact stress on the bone and improve fixation of the implant. Mediolateral load distribution was quantified and correlated with limb alignment, thereby permitting the effects of malalignment after total knee replacement to be estimated.
Journal of Orthopaedic Research | 2011
Ines Kutzner; Philipp Damm; Bernd Heinlein; Jörn Dymke; Friedmar Graichen; G. Bergmann
A conventional method to unload the medial compartment of patients with gonarthrosis and thus to achieve pain reduction is the use of laterally wedged shoes. Our aim was to measure in vivo their effect on medial compartment loads using instrumented knee implants. Medial tibio‐femoral contact forces were measured in six subjects with instrumented knee implants during walking with the following shoes: without wedge, with 5 and 10 mm wedges under the lateral sole, and with a laterally wedged insole (5 mm). Measurements were repeated with the shoes in combination with an ankle‐stabilizing orthosis. Without orthosis, peak medial forces were reduced by only 1–4% on average. With orthosis, the average reduction was 2–7%. Highest reductions were generally observed with the 10 mm wedge, followed by the 5 mm wedge, and the 5 mm insole. Individual force reductions reached up to 15%. Medial force reductions while walking with wedged shoes were generally small. Due to high inter‐individual differences, it seems that some patients might benefit from lateral wedges, whereas others might not. Further analyses of the individual kinematics will show which factors are most decisive for the reduction of medial compartment load.
Arthritis & Rheumatism | 2014
Adam Trepczynski; Ines Kutzner; G. Bergmann; William R. Taylor; Markus O. Heller
The external knee adduction moment (EAM) is often considered a surrogate measure of the distribution of loads across the tibiofemoral joint during walking. This study was undertaken to quantify the relationship between the EAM and directly measured medial tibiofemoral contact forces (Fmed) in a sample of subjects across a spectrum of activities.
Journal of Biomechanics | 2013
Ines Kutzner; Daniel Stephan; Jörn Dymke; Alwina Bender; Friedmar Graichen; G. Bergmann
Since footwear is commonly used every day, its influence on knee joint loading and thereby on the development and progression of osteoarthritis may be crucial. So far the influence of footwear has been examined only indirectly. The aim of this study was to directly measure the effect of footwear on tibiofemoral contact loads during walking. Instrumented knee implants with telemetric data transmission were used to measure the tibiofemoral contact forces and moments in six subjects. The loads during walking with four different shoes (basic running shoes, advanced running shoes, classical dress shoes and shoes with a soft rounded sole in the sagittal plane (MBT)) were compared to those during barefoot walking. Peak values of all six load components were analyzed. In general, footwear tended to increase knee joint loading slightly, with the dress shoe being the most unfavorable type of footwear. At the early stance phase all load components were increased by all shoe types. The resultant force rose by 2-5%, the internal adduction moment by 7-12% and the forces on the medial compartment by 3-5%. Significant reductions of the resultant force were solely observed for the advanced running shoe (-6%) and the MBT (-9%) shoe at late stance. Also the medial compartment force was slightly yet non-significantly reduced by 2-5% with the two shoes. It is questionable whether such small load changes have an influence on the progression of gonarthrosis. Future research is necessary to examine which factors regarding the shoe design, such as heel height, arch support or flexibility are most decisive for a reduction of knee joint loading.
BioMed Research International | 2014
Jens Schwiesau; Bernhard Fritz; Ines Kutzner; G. Bergmann; Thomas M. Grupp
The wear behaviour of total knee arthroplasty (TKA) is dominated by two wear mechanisms: the abrasive wear and the delamination of the gliding components, where the second is strongly linked to aging processes and stress concentration in the material. The addition of vitamin E to the bulk material is a potential way to reduce the aging processes. This study evaluates the wear behaviour and delamination susceptibility of the gliding components of a vitamin E blended, ultra-high molecular weight polyethylene (UHMWPE) cruciate retaining (CR) total knee arthroplasty. Daily activities such as level walking, ascending and descending stairs, bending of the knee, and sitting and rising from a chair were simulated with a data set received from an instrumented knee prosthesis. After 5 million test cycles no structural failure of the gliding components was observed. The wear rate was with 5.62 ± 0.53 mg/million cycles falling within the limit of previous reports for established wear test methods.
Journal of Biomechanics | 2017
Philipp Damm; Ines Kutzner; G. Bergmann; A. Rohlmann; Hendrik Schmidt
Walking is a task that we seek to understand because it is the most relevant human locomotion. Walking causes complex loading patterns and high load magnitudes within the human body. This work summarizes partially published load data collected in earlier in vivo measurement studies on 9 patients with telemeterized knee endoprostheses, 10 with hip endoprostheses and 5 with vertebral body replacements. Moreover, for the 19 endoprosthesis patients, additional simultaneously measured and previously unreported ground reaction forces are presented. The ground reaction force and the implant forces in the knee and hip exhibited a double peak during each step. The maxima of the ground reaction forces ranged from 100% to 126% bodyweight. In comparison, the greatest implant forces in the hip (249% bodyweight) and knee (271% bodyweight) were much greater. The mean peak force measured in the vertebral body replacement was 39% bodyweight and occurred at different time points of the stance phase. We concluded that walking leads to high load magnitudes in the knee and hip, whereas the forces in the vertebral body replacement remained relatively low. This indicates that the first peak force was greater in the hip than in the knee joint while this was reversed for the second peak force. The forces in the spinal implant were considerably lower than in the knee and hip joints.