Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Jean-Michel Bourget is active.

Publication


Featured researches published by Jean-Michel Bourget.


Acta Biomaterialia | 2014

Progress in developing a living human tissue-engineered tri-leaflet heart valve assembled from tissue produced by the self-assembly approach

Jean Dubé; Jean-Michel Bourget; Robert Gauvin; Hugues Lafrance; Charles J. Roberge; François A. Auger; Lucie Germain

The aortic heart valve is constantly subjected to pulsatile flow and pressure gradients which, associated with cardiovascular risk factors and abnormal hemodynamics (i.e. altered wall shear stress), can cause stenosis and calcification of the leaflets and result in valve malfunction and impaired circulation. Available options for valve replacement include homograft, allogenic or xenogenic graft as well as the implantation of a mechanical valve. A tissue-engineered heart valve containing living autologous cells would represent an alternative option, particularly for pediatric patients, but still needs to be developed. The present study was designed to demonstrate the feasibility of using a living tissue sheet produced by the self-assembly method, to replace the bovine pericardium currently used for the reconstruction of a stented human heart valve. In this study, human fibroblasts were cultured in the presence of sodium ascorbate to produce tissue sheets. These sheets were superimposed to create a thick construct. Tissue pieces were cut from these constructs and assembled together on a stent, based on techniques used for commercially available replacement valves. Histology and transmission electron microscopy analysis showed that the fibroblasts were embedded in a dense extracellular matrix produced in vitro. The mechanical properties measured were consistent with the fact that the engineered tissue was resistant and could be cut, sutured and assembled on a wire frame typically used in bioprosthetic valve assembly. After a culture period in vitro, the construct was cohesive and did not disrupt or disassemble. The tissue engineered heart valve was stimulated in a pulsatile flow bioreactor and was able to sustain multiple duty cycles. This prototype of a tissue-engineered heart valve containing cells embedded in their own extracellular matrix and sewn on a wire frame has the potential to be strong enough to support physiological stress. The next step will be to test this valve extensively in a bioreactor and at a later date, in a large animal model in order to assess in vivo patency of the graft.


Acta Biomaterialia | 2015

Mechanical properties of endothelialized fibroblast-derived vascular scaffolds stimulated in a bioreactor

Maxime Y. Tondreau; Véronique Laterreur; Robert Gauvin; Karine Vallières; Jean-Michel Bourget; Dan Lacroix; Catherine Tremblay; Lucie Germain; Jean Ruel; François A. Auger

There is an ongoing clinical need for tissue-engineered small-diameter (<6mm) vascular grafts since clinical applications are restricted by the limited availability of autologous living grafts or the lack of suitability of synthetic grafts. The present study uses our self-assembly approach to produce a fibroblast-derived decellularized vascular scaffold that can then be available off-the-shelf. Briefly, scaffolds were produced using human dermal fibroblasts sheets rolled around a mandrel, maintained in culture to allow for the formation of cohesive and three-dimensional tubular constructs, and then decellularized by immersion in deionized water. Constructs were then endothelialized and perfused for 1week in an appropriate bioreactor. Mechanical testing results showed that the decellularization process did not influence the resistance of the tissue and an increase in ultimate tensile strength was observed following the perfusion of the construct in the bioreactor. These fibroblast-derived vascular scaffolds could be stored and later used to deliver readily implantable grafts within 4weeks including an autologous endothelial cell isolation and seeding process. This technology could greatly accelerate the clinical availability of tissue-engineered blood vessels.


Journal of The Mechanical Behavior of Biomedical Materials | 2014

Comparison of the direct burst pressure and the ring tensile test methods for mechanical characterization of tissue-engineered vascular substitutes

Véronique Laterreur; Jean Ruel; François A. Auger; Karine Vallières; Catherine Tremblay; Dan Lacroix; Maxime Y. Tondreau; Jean-Michel Bourget; Lucie Germain

Tissue engineering provides a promising alternative for small diameter vascular grafts, especially with the self-assembly method. It is crucial that these grafts possess mechanical properties that allow them to withstand physiological flow and pressure without being damaged. Therefore, an accurate assessment of their mechanical properties, especially the burst pressure, is essential prior to clinical release. In this study, the burst pressure of self-assembled tissue-engineered vascular substitutes was first measured by the direct method, which consists in pressurizing the construct with fluid until tissue failure. It was then compared to the burst pressure estimated by Laplace׳s law using data from a ring tensile test. The major advantage of this last method is that it requires a significantly smaller tissue sample. However, it has been reported as overestimating the burst pressure compared to a direct measurement. In the present report, it was found that an accurate estimation of the burst pressure may be obtained from a ring tensile test when failure internal diameter is used as the diameter parameter in Laplace׳s law. Overestimation occurs with the method previously reported, i.e. when the unloaded internal diameter is used for calculations. The estimation of other mechanical properties was also investigated. It was demonstrated that data from a ring tensile test provide an accurate estimate of the failure strain and the stiffness of the constructs when compared to measurements with the direct method.


Archive | 2013

Alignment of Cells and Extracellular Matrix Within Tissue- Engineered Substitutes

Jean-Michel Bourget; Maxime D. Guillemette; Teodor Veres; François A. Auger; Lucie Germain

Most of the cells in our body are in direct contact with extracellular matrix (ECM) compo‐ nents which constitute a complex network of nano-scale proteins and glycosaminoglycans. Those cells constantly remodel the ECM by different processes. They build it by secreting dif‐ ferent proteins such as collagen, proteoglycans, laminins or degrade it by producing factors such as matrix metalloproteinase (MMP). Cells interact with the ECM via specific receptors, the integrins [1]. They also organize this matrix, guided by different stimuli, to generate pat‐ terns, essential for tissue and organ functions. Reciprocally, cells are guided by the ECM, they modify their morphology and phenotype depending on the protein types and organization via bidirectional integrin signaling [2-4]. In the growing field of tissue engineering [5], control of these aspects are of the utmost importance to create constructs that closely mimic native tis‐ sues. To do so, we must take into account the composition of the scaffold (synthetic, natural, biodegradable or not), its organization and the dimension of the structure.


Tissue Engineering Part C-methods | 2014

A new construction technique for tissue-engineered heart valves using the self-assembly method.

Catherine Tremblay; Jean Ruel; Jean-Michel Bourget; Laterreur; Karine Vallières; Maxime Y. Tondreau; Dan Lacroix; Lucie Germain; François A. Auger

Tissue engineering appears as a promising option to create new heart valve substitutes able to overcome the serious drawbacks encountered with mechanical substitutes or tissue valves. The objective of this article is to present the construction method of a new entirely biological stentless aortic valve using the self-assembly method and also a first assessment of its behavior in a bioreactor when exposed to a pulsatile flow. A thick tissue was created by stacking several fibroblast sheets produced with the self-assembly technique. Different sets of custom-made templates were designed to confer to the thick tissue a three-dimensional (3D) shape similar to that of a native aortic valve. The construction of the valve was divided in two sequential steps. The first step was the installation of the thick tissue in a flat preshaping template followed by a 4-week maturation period. The second step was the actual cylindrical 3D forming of the valve. The microscopic tissue structure was assessed using histological cross sections stained with Massons Trichrome and Picrosirius Red. The thick tissue remained uniformly populated with cells throughout the construction steps and the dense extracellular matrix presented corrugated fibers of collagen. This first prototype of tissue-engineered heart valve was installed in a bioreactor to assess its capacity to sustain a light pulsatile flow at a frequency of 0.5 Hz. Under the light pulsed flow, it was observed that the leaflets opened and closed according to the flow variations. This study demonstrates that the self-assembly method is a viable option for the construction of complex 3D shapes, such as heart valves, with an entirely biological material.


Tissue Engineering Part A | 2009

Applications of Human Tissue-Engineered Blood Vessel Models to Study the Effects of Shed Membrane Microparticles from T-Lymphocytes on Vascular Function

Maria Pricci; Jean-Michel Bourget; Hubert Robitaille; Chiara Porro; Raffaella Soleti; H. Ahmed Mostefai; François A. Auger; M. Carmen Martinez; Ramaroson Andriantsitohaina; Lucie Germain

Microparticles (MPs) are membrane vesicles harboring cell surface proteins and containing cytoplasmic components of the original cell. High levels of circulating MPs have been detected in pathological states associated with vascular dysfunction. We took advantage of the self-assembly method of tissue engineering to produce in vitro three vascular constructs from human vascular smooth muscle cells and fibroblasts to investigate the role of the adventitia in the modulation of vascular tone by MPs, comparing the contractile response of each of these constructs to histamine. The first two were composed of an adventitia (tissue-engineered vascular adventitia (TEVA)) or a media (tissue-engineered vascular media (TEVM)) solely, and the third one contained a media and an adventitia (tissue-engineered vascular media and adventitia (TEVMA)). In the three constructs, the results show that histamine induces contraction insensitive to blockade of inducible nitric oxide (NO) synthase (iNOS) and cyclooxygenase-2 (COX-2) and not affected by MP treatment. MPs decreased NO production and nuclear factor (NF)-kappaB expression but did not affect superoxide anion (O(2)(-)) release in TEVA. MPs enhanced NF-kappaB expression but did not affect iNOS and COX-2 expression or NO or O(2)(-) release in TEVM. In TEVMA, MPs did not enhance NF-kappaB expression, but COX-2 expression was higher, and O(2)(-) release was lower. Thus, MPs affected NO, O(2)(-), NF-kappaB, and COX-2 in a subtle fashion to maintain the contractile response to histamine. The use of tissue-engineered vascular constructs results in a better understanding of the effect of MPs on human adventitia and media.


BioMed Research International | 2016

Patterning of Endothelial Cells and Mesenchymal Stem Cells by Laser-Assisted Bioprinting to Study Cell Migration

Jean-Michel Bourget; Olivia Kérourédan; Manuela Medina; Murielle Rémy; Noëlie Thebaud; Reine Bareille; Olivier Chassande; Joëlle Amédée; Sylvain Catros; Raphaël Devillard

Tissue engineering of large organs is currently limited by the lack of potent vascularization in vitro. Tissue-engineered bone grafts can be prevascularized in vitro using endothelial cells (ECs). The microvascular network architecture could be controlled by printing ECs following a specific pattern. Using laser-assisted bioprinting, we investigated the effect of distance between printed cell islets and the influence of coprinted mesenchymal cells on migration. When printed alone, ECs spread out evenly on the collagen hydrogel, regardless of the distance between cell islets. However, when printed in coculture with mesenchymal cells by laser-assisted bioprinting, they remained in the printed area. Therefore, the presence of mesenchymal cell is mandatory in order to create a pattern that will be conserved over time. This work describes an interesting approach to study cell migration that could be reproduced to study the effect of trophic factors.


Clinical Science | 2013

Interleukin-10 controls the protective effects of circulating microparticles from patients with septic shock on tissue-engineered vascular media.

Hadj Ahmed Mostefai; Jean-Michel Bourget; Ferhat Meziani; Maria Martinez; Daniela Leonetti; Alain Mercat; Lucie Germain; Ramaroson Andriantsitohaina

During sepsis, inflammation can be orchestrated by the interaction between circulating and vascular cells that, under activation, release MPs (microparticles). Previously, we reported that increased circulating MPs in patients with sepsis play a pivotal role in ex vivo vascular function suggesting that they are protective against vascular hyporeactivity. The present study was designed to investigate the effects of MPs from patients with sepsis on the contractile response of TEVM (tissue-engineered vascular media). TEVM that were composed only of a media layer were produced by tissue engineering from human arterial SMCs (smooth muscle cells) isolated from umbilical cords. TEVM was incubated with MPs isolated from whole blood of 16 patients with sepsis. TEVM were incubated for 24 h with MPs and used for the study of vascular contraction, direct measurements of NO and O2- (superoxide anion) production by EPR and quantification of mRNA cytokine expression. MPs from patients with sepsis increased contraction induced by histamine in TEVM. This effect was not associated with inflammation, neither linked to the activation of NF-κB (nuclear factor κB) pathway nor to the increase in iNOS (inducible NO synthase) and COX (cyclo-oxygenase)-2 expression. In contrast, mRNA expression of IL (interleukin)-10 was enhanced. Then, we investigated the effect of IL-10 on vascular hyporeactivity induced by LPS (lipopolysaccharide). Although IL-10 treatment did not modify the contractile response in TEVM by itself, this interleukin restored contraction in LPS-treated TEVM. In addition, IL-10 treatment both prevented vascular hyporeactivity induced by LPS injection in mice and improved survival of LPS-injected mice. These findings show an association between the capacity of MPs from patients with sepsis to restore vascular hyporeactivity induced by LPS and their ability to increase IL-10 in the tissue-engineered blood vessel model.


Journal of Cellular Physiology | 2015

Contribution of Sp1 to Telomerase Expression and Activity in Skin Keratinocytes Cultured With a Feeder Layer.

Francis Bisson; Claudie Paquet; Jean-Michel Bourget; Karine Zaniolo; Patrick J. Rochette; Solange Landreville; Odile Damour; François Boudreau; François A. Auger; Sylvain L. Guérin; Lucie Germain

The growth of primary keratinocytes is improved by culturing them with a feeder layer. The aim of this study was to assess whether the feeder layer increases the lifespan of cultured epithelial cells by maintaining or improving telomerase activity and expression. The addition of an irradiated fibroblast feeder layer of either human or mouse origin (i3T3) helped maintain telomerase activity as well as expression of the transcription factor Sp1 in cultured keratinocytes. In contrast, senescence occurred earlier, together with a reduction of Sp1 expression and telomerase activity, in keratinocytes cultured without a feeder layer. Telomerase activity was consistently higher in keratinocytes grown on the three different feeder layers tested relative to cells grown without them. Suppression of Sp1 expression by RNA inhibition (RNAi) reduced both telomerase expression and activity in keratinocytes and also abolished their long‐term growth capacity suggesting that Sp1 is a key regulator of both telomerase gene expression and cell cycle progression of primary cultured human skin keratinocytes. The results of the present study therefore suggest that the beneficial influence of the feeder layer relies on its ability to preserve telomerase activity in cultured human keratinocytes through the maintenance of stable levels of Sp1 expression. J. Cell. Physiol. 230: 308–317, 2015.


BioMed Research International | 2015

Potential of Newborn and Adult Stem Cells for the Production of Vascular Constructs Using the Living Tissue Sheet Approach.

Jean-Michel Bourget; Robert Gauvin; David Duchesneau; Murielle Rémy; François A. Auger; Lucie Germain

Bypass surgeries using native vessels rely on the availability of autologous veins and arteries. An alternative to those vessels could be tissue-engineered vascular constructs made by self-organized tissue sheets. This paper intends to evaluate the potential use of mesenchymal stem cells (MSCs) isolated from two different sources: (1) bone marrow-derived MSCs and (2) umbilical cord blood-derived MSCs. When cultured in vitro, a proportion of those cells differentiated into smooth muscle cell- (SMC-) like cells and expressed contraction associated proteins. Moreover, these cells assembled into manipulable tissue sheets when cultured in presence of ascorbic acid. Tubular vessels were then produced by rolling those tissue sheets on a mandrel. The architecture, contractility, and mechanical resistance of reconstructed vessels were compared with tissue-engineered media and adventitia produced from SMCs and dermal fibroblasts, respectively. Histology revealed a collagenous extracellular matrix and the contractile responses measured for these vessels were stronger than dermal fibroblasts derived constructs although weaker than SMCs-derived constructs. The burst pressure of bone marrow-derived vessels was higher than SMCs-derived ones. These results reinforce the versatility of the self-organization approach since they demonstrate that it is possible to recapitulate a contractile media layer from MSCs without the need of exogenous scaffolding material.

Collaboration


Dive into the Jean-Michel Bourget's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge