Leily Macedo Firoozmand
Federal University of Maranhão
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Leily Macedo Firoozmand.
Brazilian Dental Journal | 2012
Gabriela da Rocha Leódido; Hianna Oliveira Fernandes; Mateus Rodrigues Tonetto; Cristina Dupim Presoto; Matheus Coelho Bandeca; Leily Macedo Firoozmand
The aim of this in vitro study was to evaluate the shear bond strength of brackets after pre-treatment with different fluoride solutions. This study used 48 freshly extracted sound bovine incisors that were randomly assigned to 4 experimental groups (n=12). CG: (control) without treatment; NF: 4 min application of neutral fluoride; APF: application of 1.23% acidulated phosphate fluoride (APF) for 4 min; and SFV: application of 5% sodium fluoride varnish for 6 h. For each group, after surface treatment, prophylaxis of enamel and bracket bonding with Transbond XT composite resin (3M) were performed following the manufacturers specifications. The shear bond strength was performed with a universal testing machine 24 h after fixing the brackets. The tooth surfaces were analyzed to verify the adhesive remnant index (ARI). Data were analyzed statistically by ANOVA and Tukeys test (α=0.05). There was statistically significant difference among the groups (p<0.0001). CG and NF groups presented significantly higher bond strength than APF and SFV. There was no significant difference between CG and NF or between APF and SFV (p>0.05). The analysis of ARI scores revealed that most failures occurred at the enamel-resin interface. It may be concluded that the pre-treatment of enamel with 1.23% APF and 5% SFV prior to fixing orthodontic brackets reduces shear bond strength values.
Brazilian Oral Research | 2013
Leily Macedo Firoozmand; Juliana Viana Pereira Brandão; Melissa Proença Nogueira Fialho
The aim of this study was to evaluate the shear bond strength (SBS) of polycrystalline ceramic brackets (PCB) bonded after bleaching treatment using different composite resins and enamel etching times. A total of 144 bovine incisors were randomly divided into two study groups (n = 72, each) as follows: G1, enamel bleached with 35% hydrogen peroxide, and G2 (control group), enamel unbleached. After the bleaching treatment, the samples were stored in artificial saliva for 14 days. These groups were further divided into two subgroups (n = 36, each) as follows: GA, brackets bonded with Transbond XT (3M) and GB, brackets bonded with Filtek Z250 (3M). For each resin used, three different etching times with 37% phosphoric acid (15, 30 and 60 seconds) were tested. SBS tests were performed using a universal testing machine (EMIC), and the adhesive remnant index (ARI) score was verified. Significant differences among the three experimental conditions and interactions between the groups were observed. The type of composite resin accounted for 24% of the influence on the bond strength, whereas the etching time and bleaching treatment accounted for 14.5% and 10% of the influence on bond strength, respectively. The ARI revealed that the most common area of adhesion failure was at the composite resin-bracket interface. The type of composite resin, etching time and external bleaching significantly influenced the SBS of PCB on enamel, even after 14 days of saliva storage.
The Scientific World Journal | 2016
Leily Macedo Firoozmand; Mariana Gonçalves Cordeiro; Marcos André dos Santos da Silva; Rudys Rodolfo de Jesus Tavarez; Etevaldo Matos Maia Filho
The aim of this study was to evaluate the radiopacity of silorane and methacrylate resin composites, comparing them to the enamel, dentin, and aluminum penetrometer using a digital image. From six resin composites (Filtek™ P90, Filtek Z350, Filtek Z350 XT flow, Tetric Ceram, TPH Spectrum, and SureFil SDR flow) cylindrical disks (5 × 1u2009mm) were made and radiographed by a digital method, together with a 15-step aluminum step-wedge and a 1u2009mm slice of human tooth. The degree of radiopacity of each image was quantified using digital image processing. The mean values of the shades of gray of the tested materials were measured and the equivalent width of aluminum was calculated for each resin. The results of our work yielded the following radiopacity values, given here in descending order: Tetric Ceram > TPH > SDR > Z350 > Z350 flow > P90 > enamel > dentin. The radiopacity of the materials was different both for the enamel and for the dentin, except for resin P90, which was no different than enamel. In conclusion, silorane-based resin exhibited a radiopacity higher than dentin and closest to the enamel; a large portion of the methacrylate-based flow and conventional resins demonstrated greater radiopacity in comparison to dentin and enamel.
The Scientific World Journal | 2015
Gisele Lima Bezerra; Carlos Rocha Gomes Torres; Mateus Rodrigues Tonetto; Álvaro Henrique Borges; Milton Carlos Kuga; Matheus Coelho Bandeca; Leily Macedo Firoozmand
The objective of this study is to assess, in vitro, the shear bond strength of orthodontic brackets fixed with remineralizing adhesive systems submitted to thermomechanical cycling, simulating one year of orthodontic treatment. Sixty-four bovine incisor teeth were randomly divided into 4 experimental groups (n = 16): XT: Transbond XT, QC: Quick Cure, OL: Ortholite Color, and SEP: Transbond Plus Self-Etching Primer. The samples were submitted to thermomechanical cycling simulating one year of orthodontic treatment. Shear bond strength tests were carried out using a universal testing machine with a load cell of 50u2009KgF at 0.5u2009mm/minute. The samples were examined with a stereomicroscope and a scanning electron microscope (SEM) in order to analyze enamel surface and Adhesive Remnant Index (ARI). Kruskal-Wallis and Mann-Whitney (with Bonferroni correction) tests showed a significant difference between the studied groups (p < 0.05). Groups XT, QC, and SEP presented the highest values of adhesive resistance and no statistical differences were found between them. The highest frequency of failures between enamel and adhesive was observed in groups XT, QC, and OL. Quick Cure (QC) remineralizing adhesive system presented average adhesive resistance values similar to conventional (XT) and self-etching (SEP) adhesives, while remineralizing system (OL) provided the lowest values of adhesive resistance.
Brazilian Dental Journal | 2018
Lauber José dos Santos Almeida Junior; Estevam Carlos de Oliveira Lula; Karla Janilee de Souza Penha; Vinicius Souza Correia; Fernando Augusto Cintra Magalhães; Darlon Martins Lima; Leily Macedo Firoozmand
The present study aimed to evaluates polymerization shrinkage (PS) using microcomputed tomography (μCT) and microtensile bond strength (μTBS) in bulk fill composites (BFC) and conventional class I restorations as well as the correlation between these factors. Class I cavities (4 x 5 x 4 mm), factor-C = 4.2, were created in third molars that were free of caries, which were randomly divided in 4 groups (n = 6): XTI (Filtek Supreme XTE: incremental technique); XTB (Filtek Supreme XTE: single fill technique); TBF (Tetric Bulk Fill); and SF (SonicFill). Each tooth was scanned twice in μCT: T0 was after filling the cavity with composite, and T1 was after light curing. The data were analyzed by subtracting the composite volume for each time (T1 - T0). After 1 week, the teeth were sectioned crosswise in the buccolingual and mesiodistal directions to obtain specimens with approximately 1 mm² thickness and fixed in a universal testing machine to perform μTBS. The Kruskal-Wallis and Dunn tests showed a statistically significant difference for shrinkage in µCT among the XTI and XTB and between the SF and XTB. Regarding the μTBS, all the groups differed from XTB. Bulk fill composites type presents a PS similar to that of the conventional nanoparticulate composite inserted using the incremental technique, but the bond strength was higher for the incremental group, which presented a lower number of pre-test failures when compared to BFC. No correlation was observed between the polymerization shrinkage and bond strength in the studied composites.
Clinical, Cosmetic and Investigational Dentistry | 2017
Rudys Rodolfo de Jesus Tavarez; Lauber José dos Santos Almeida Junior; Tayanne Christine Gomes Guará; Izabella Santos Ribeiro; Etevalo Matos Maia Filho; Leily Macedo Firoozmand
Objectives The purpose of this study was to evaluate the influence of surface treatment and different types of composite resin on the microshear bond strength of repairs. Materials and methods Seventy-two specimens (n=72) were prepared using a nanoparticle resin and stored in artificial saliva at 37 ± 1°C for 24 h. After this period, the specimens (n=24) were restored with microhybrid resin P60 (3M ESPE), nanoparticle resin Filtek Z350 (3M ESPE), and Bulk Fill Surefil SDR Flow (Dentsply) composite resins. Previously, the surfaces of the samples were treated, forming the following subgroups (n=12): (A) conditioned with 37% phosphoric acid for 30 s, and (B) abrasioned with a diamond tip for 3 s and conditioned with 37% phosphoric acid. In all groups, before insertion of the composite resin, the adhesive system Adper Single Bond 2 was actively applied and photopolymerized for 20 s. Results The microshear test was executed to assess bond strength. Kruskal–Wallis (p<0.05) and Mann–Whitney statistical tests showed significant statistical difference considering that the bulk-fill resin turned out to have a lower bond strength than the conventional nanoparticle and microhybrid composites. With regard to the technique, the roughening with diamond bur followed by the application of phosphoric acid exhibited values higher than the exclusive use of acid. Conclusion The microshear bond strength of the composite resin repairs varies in accordance with the type of composite resin utilized, and roughening the surface increased the bond strength of these materials.
Clinical, Cosmetic and Investigational Dentistry | 2017
Rudys Rodolfo de Jesus Tavarez; Gisele Lima Bezerra; Karla Janilee de Souza Penha; Carlos Rocha Gomes Torres; Leily Macedo Firoozmand
Objective The aim of this study was to evaluate in vitro bond strength of metal brackets bonded with: total etch, total etch with erbium: yttrium aluminum garnet laser (Er:YAG) and self-etching adhesive systems, submitted to thermal-mechanical cycling, simulating 1 year of orthodontic treatment. Materials and methods For the study, 80 bovine incisors were randomly divided into 3 experimental groups (n=16 each): XT- acid etching + Transbond XT, XT/Er:YAG- Transbond XT associated with Er:YAG laser irradiation (λ=2.94 μm, 60 mJ, 10 Hz) and SEP- Transbond Plus Self Etching Primer. Samples were submitted to thermal-mechanical cycling, simulating 1 year of orthodontic treatment. Afterward, the shear bond strength test was performed in a universal test machine at a speed of 0.5mm/min. Samples were evaluated under a stereomicroscope and by scanning electron microscopy for analysis of enamel surface and adhesive remnant index. Data were analyzed using Kruskal–Wallis and Mann–Whitney (with Bonferroni correction) statistical tests. Results Statistically significant difference was observed between the groups studied (p<0.05). Groups XT and SEP showed the highest bond strength values, without statistical difference between them, while group XT/Er:YAG showed reduction in bond strength values. Higher frequency of adhesive failures between enamel and adhesive system was verified for groups XT and XT/Er:YAG. Conclusion The conventional (XT) and self-etching (SEP) adhesive systems showed mean bond strength values, similar between them, whereas the previous application of Er:YAG laser promoted the lowest bond strength values.
Brazilian Oral Research | 2017
Lauber José dos Santos Almeida Junior; Karla Janilee de Souza Penha; Ana Ferreira Souza; Estevam Carlos de Oliveira Lula; Fernando Augusto Cintra Magalhães; Darlon Martins Lima; Leily Macedo Firoozmand
This in vitro study aimed to evaluate the volume of polymerization shrinkage (VS), gap (VG), and void (VV) using computerized microtomography (μCT) in bulk fill resin composites and conventional class I restorations, and to establish a correlation between these factors. Class I cavities (4 x 5 x 4 mm), C-factor = 4.2, were performed on caries-free human third molars and randomly divided into five groups (n = 6): FSI (Filtek Supreme XTE incremental insertion); FSS [(Filtek Supreme XTE single insertion(SI)]; TBF [(Tetric Bulk Fill: SI and manual filling (MF)]; SFM (Sonic Fill: SI/MF); and SFS (SonicFill: SI and sonic filling). The teeth were scanned and analyzed by μCT at T0, after filling the cavity with resin, and at T1, after polymerization for VG and VV, and for VS (T1-T0). There was statistically significant difference in VS in μCT for the FSI and FSS groups and between SFS and FSS as well as some difference in VV for FSI and bulk fill resin composites and no difference in VG between the conventional technique and bulk fill composites. Bulk fill resin composites presented similar VS and gap formation to those of incrementally inserted conventional resin composites. There is a moderate and weak positive correlation between polymerization shrinkage and gap formation and void, respectively. The final gap formation was more dependent on the initial gap than on polymerization shrinkage or void volume.
Rev. Odonto Ciênc. (Online) | 2016
Fernando Pinheiro Fialho; Leily Macedo Firoozmand
Objective: Depending on the degree of saturation and time that pigments have been in the dentalxa0tissue, teeth with severe color change may have a poor prognosis for bleaching treatment. Case Report: In the reported case, after a careful clinical history and evaluation of clinical case axa0conservative treatment with composite resin restoration was carried out on superior central incisorxa0with severe darkening. Direct composite resins with different opacity and translucency in associationxa0with resin pigments and a conservative technique were used guaranteeing a minimal intervention andxa0giving a natural aspect to the tooth. The use of pigments made possible less wear of dental structurexa0for insertion of the composite resin, mimetizing the restored tooth with the corresponding teeth. Conclusion: It was concluded that in some cases where indirect restorations would be indicated,xa0when different kinds of dental materials and techniques are applied, direct restorative treatmentxa0would be a great option for esthetic restorations.
Brazilian Dental Journal | 2015
Leily Macedo Firoozmand; Lawanne Ellen Carvalho Noleto; Isabella Azevedo Gomes; José Bauer; Meire Coelho Ferreira
The aim of this study was evaluate in vitro the influence of simplified adhesive systems (etch-and-rinse and self-etching) and 1.23% acidulated phosphate fluoride (APF) on the microshear bond strength (μ-SBS) of composite resins on primary molars and incisors. Forty primary molars and forty incisors vestibular enamel was treated with either the self-etching Clearfil SE Bond (CSE, Kuraray) or etch-and-rinse Adper Single Bond 2 (SB2, 3M/ESPE) adhesive system. Each group was subdivided based on the prior treatment of the enamel with or without the topical application of 1.23% APF. Thereafter, matrices were positioned and filled with composite resin and light cured. After storage in distilled water at 37 ± 1°C for 24 h, the specimens were submitted to μ-SBS in a universal testing machine. Kruskal-Wallis and Mann-Whitney tests (p < 0.05) showed that the prior application of 1.23% APF led to a significant reduction in bond strength. The type of adhesive exerted no significant influence bond strength. In the inter-group analysis, however, significantly bond strength reduction was found for the incisors when CSE was employed with APF. Adhesive failure was the most common type of fracture. The bond strength was affected by the prior application of 1.23% APF and type of tooth.