Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Martijn Riool is active.

Publication


Featured researches published by Martijn Riool.


Acta Biomaterialia | 2014

Staphylococcus epidermidis originating from titanium implants infects surrounding tissue and immune cells

Martijn Riool; Leonie de Boer; Valery Jaspers; Chris M. van der Loos; Willem J. B. van Wamel; Gang Wu; Paulus H. S. Kwakman; Sebastian A. J. Zaat

Infection is a major cause of failure of inserted or implanted biomedical devices (biomaterials). During surgery, bacteria may adhere to the implant, initiating biofilm formation. Bacteria are also observed in and recultured from the tissue surrounding implants, and may even reside inside host cells. Whether these bacteria originate from biofilms is not known. Therefore, we investigated the fate of Staphylococcus epidermidis inoculated on the surface of implants as adherent planktonic cells or as a biofilm in mouse experimental biomaterial-associated infection. In order to discriminate the challenge strain from potential contaminating mouse microflora, we constructed a fully virulent green fluorescent S. epidermidis strain. S. epidermidis injected along subcutaneous titanium implants, pre-seeded on the implants or pre-grown as biofilm, were retrieved from the implants as well as the surrounding tissue in all cases after 4days, and in histology bacteria were observed in the tissue co-localizing with macrophages. Thus, bacteria adherent to or in a biofilm on the implant are a potential source of infection of the surrounding tissue, and antimicrobial strategies should prevent both biofilm formation and tissue colonization.


Journal of Controlled Release | 2015

A doxycycline-loaded polymer-lipid encapsulation matrix coating for the prevention of implant-related osteomyelitis due to doxycycline-resistant methicillin-resistant Staphylococcus aureus.

Willem-Jan Metsemakers; Noam Emanuel; Or Cohen; Malka Reichart; Inga Potapova; Tanja Schmid; David Segal; Martijn Riool; Paulus H. S. Kwakman; Leonie de Boer; Anna de Breij; Peter H. Nibbering; R. Geoff Richards; Sebastian A. J. Zaat; T. Fintan Moriarty

Implant-associated bone infections caused by antibiotic-resistant pathogens pose significant clinical challenges to treating physicians. Prophylactic strategies that act against resistant organisms, such as methicillin-resistant Staphylococcus aureus (MRSA), are urgently required. In the present study, we investigated the efficacy of a biodegradable Polymer-Lipid Encapsulation MatriX (PLEX) loaded with the antibiotic doxycycline as a local prophylactic strategy against implant-associated osteomyelitis. Activity was tested against both a doxycycline-susceptible (doxy(S)) methicillin-susceptible S. aureus (MSSA) as well as a doxycycline-resistant (doxy(R)) methicillin-resistant S. aureus (MRSA). In vitro elution studies revealed that 25% of the doxycycline was released from the PLEX-coated implants within the first day, followed by a 3% release per day up to day 28. The released doxycycline was highly effective against doxy(S) MSSA for at least 14days in vitro. A bolus injection of doxycycline mimicking a one day release from the PLEX-coating reduced, but did not eliminate, mouse subcutaneous implant-associated infection (doxy(S) MSSA). In a rabbit intramedullary nail-related infection model, all rabbits receiving a PLEX-doxycycline-coated nail were culture negative in the doxy(S) MSSA-group and the surrounding bone displayed a normal physiological appearance in both histological sections and radiographs. In the doxy(R) MRSA inoculated rabbits, a statistically significant reduction in the number of culture-positive samples was observed for the PLEX-doxycycline-coated group when compared to the animals that had received an uncoated nail, although the reduction in bacterial burden did not reach statistical significance. In conclusion, the PLEX-doxycycline coating on titanium alloy implants provided complete protection against implant-associated MSSA osteomyelitis, and resulted in a significant reduction in the number of culture positive samples when challenged with a doxycycline-resistant MRSA.


Journal of Controlled Release | 2016

Prevention of Staphylococcus aureus biomaterial-associated infections using a polymer-lipid coating containing the antimicrobial peptide OP-145.

A. de Breij; Martijn Riool; Paulus H. S. Kwakman; L. de Boer; Robert A. Cordfunke; Jan W. Drijfhout; Or Cohen; Noam Emanuel; Sebastian A. J. Zaat; Peter H. Nibbering; T.F. Moriarty

The scarcity of current antibiotic-based strategies to prevent biomaterial-associated infections (BAI) and their risk of resistance development prompted us to develop a novel antimicrobial implant-coating to prevent Staphylococcus aureus-induced BAI. We incorporated the antimicrobial peptide OP-145 into a Polymer-Lipid Encapsulation MatriX (PLEX)-coating to obtain high peptide levels for prolonged periods at the implant-tissue interphase. We first confirmed that OP-145 was highly effective in killing S. aureus and inhibiting biofilm formation in vitro. OP-145 injected along S. aureus-inoculated implants in mice significantly reduced the number of culture-positive implants. OP-145 was released from the PLEX coating in a controlled zero-order kinetic rate after an initial 55%-burst release and displayed bactericidal activity in vitro. In a rabbit intramedullary nail-related infection model, 67% of rabbits with PLEX-OP-145-coated nails had culture-negative nails after 28days compared to 29% of rabbits with uncoated nails. In rabbits with PLEX-OP-145-coated nails, bone and soft tissue samples were culture-negative in 67% and 80%, respectively, whereas all bone samples and 71% of the soft tissue samples of rabbits with uncoated nails were infected. Together, PLEX-OP-145 coatings, of which both compounds have already been found safe in man, can prevent implant colonization and S. aureus-induced BAIs.


Frontiers in chemistry | 2017

Antimicrobial Peptides in Biomedical Device Manufacturing

Martijn Riool; Anna de Breij; Jan W. Drijfhout; Peter H. Nibbering; Sebastian A. J. Zaat

Over the past decades the use of medical devices, such as catheters, artificial heart valves, prosthetic joints, and other implants, has grown significantly. Despite continuous improvements in device design, surgical procedures, and wound care, biomaterial-associated infections (BAI) are still a major problem in modern medicine. Conventional antibiotic treatment often fails due to the low levels of antibiotic at the site of infection. The presence of biofilms on the biomaterial and/or the multidrug-resistant phenotype of the bacteria further impair the efficacy of antibiotic treatment. Removal of the biomaterial is then the last option to control the infection. Clearly, there is a pressing need for alternative strategies to prevent and treat BAI. Synthetic antimicrobial peptides (AMPs) are considered promising candidates as they are active against a broad spectrum of (antibiotic-resistant) planktonic bacteria and biofilms. Moreover, bacteria are less likely to develop resistance to these rapidly-acting peptides. In this review we highlight the four main strategies, three of which applying AMPs, in biomedical device manufacturing to prevent BAI. The first involves modification of the physicochemical characteristics of the surface of implants. Immobilization of AMPs on surfaces of medical devices with a variety of chemical techniques is essential in the second strategy. The main disadvantage of these two strategies relates to the limited antibacterial effect in the tissue surrounding the implant. This limitation is addressed by the third strategy that releases AMPs from a coating in a controlled fashion. Lastly, AMPs can be integrated in the design and manufacturing of additively manufactured/3D-printed implants, owing to the physicochemical characteristics of the implant material and the versatile manufacturing technologies compatible with antimicrobials incorporation. These novel technologies utilizing AMPs will contribute to development of novel and safe antimicrobial medical devices, reducing complications and associated costs of device infection.


Materials Science and Engineering: C | 2017

Fabrication of oxide layer on zirconium by micro-arc oxidation: Structural and antimicrobial characteristics

S. Fidan; Faiz Muhaffel; Martijn Riool; G. Cempura; L. de Boer; Sebastian A. J. Zaat; A. Czyrska Filemonowicz; Huseyin Cimenoglu

The aim of this study was to cover the surfaces of zirconium (Zr) with an antimicrobial layer for biomedical applications. For this purpose, the micro-arc oxidation (MAO) process was employed in a sodium silicate and sodium hydroxide containing base electrolyte with and without addition of silver acetate (AgC2H3O2). In general, synthesized MAO layers were composed of zirconium oxide (ZrO2) and zircon (ZrSiO4). Addition of AgC2H3O2 into the base electrolyte caused homogenous precipitation of silver-containing particles in the MAO layer, which exhibited excellent antibacterial efficiency against methicillin-resistant Staphylococcus aureus (MRSA) as compared to the untreated and MAO-treated Zr.


EFORT Open Reviews | 2016

Orthopaedic device-related infection: current and future interventions for improved prevention and treatment

T. Fintan Moriarty; Richard Kuehl; Tom Coenye; Willem-Jan Metsemakers; Mario Morgenstern; Edward M. Schwarz; Martijn Riool; Sebastiaan A. J. Zaat; Nina Khana; Stephen L. Kates; R. Geoff Richards

Orthopaedic and trauma device-related infection (ODRI) remains one of the major complications in modern trauma and orthopaedic surgery. Despite best practice in medical and surgical management, neither prophylaxis nor treatment of ODRI is effective in all cases, leading to infections that negatively impact clinical outcome and significantly increase healthcare expenditure. The following review summarises the microbiological profile of modern ODRI, the impact antibiotic resistance has on treatment outcomes, and some of the principles and weaknesses of the current systemic and local antibiotic delivery strategies. The emerging novel strategies aimed at preventing or treating ODRI will be reviewed. Particular attention will be paid to the potential for clinical impact in the coming decades, when such interventions are likely to be critically important. The review focuses on this problem from an interdisciplinary perspective, including basic science innovations and best practice in infectious disease. Cite this article: Moriarty TF, Kuehl R, Coenye T, et al. Orthopaedic device related infection: current and future interventions for improved prevention and treatment. EFORT Open Rev 2016;1:89-99. DOI: 10.1302/2058-5241.1.000037.


Science Translational Medicine | 2018

The antimicrobial peptide SAAP-148 combats drug-resistant bacteria and biofilms

Anna de Breij; Martijn Riool; Robert A. Cordfunke; Nermina Malanovic; Leonie de Boer; Roman I. Koning; Elisabeth Ravensbergen; Marnix Franken; Tobias van der Heijde; Bouke K. Boekema; Paulus H. S. Kwakman; Niels Kamp; Abdelouahab El Ghalbzouri; Karl Lohner; Sebastian A. J. Zaat; Jan W. Drijfhout; Peter H. Nibbering

Infections refractory to conventional antibiotics may be targeted by the antimicrobial peptide SAAP-148. New way to keep bacteria at bay Antibiotic resistance is a major threat to public health. To develop a new type of weapon in the arms race against bacteria, de Breij et al. generated a panel of synthetic peptides based on the human antimicrobial peptide LL-37. The lead candidate from this panel, SAAP-148, can kill dangerous antibiotic-resistant pathogens in many contexts, including on ex vivo human skin and in biofilms. Long-term exposure to SAAP-148 did not induce bacterial resistance. Topical application of SAAP-148 could one day be used in hospitals to help patients combat bacteria resistant to traditional antibiotics. Development of novel antimicrobial agents is a top priority in the fight against multidrug-resistant (MDR) and persistent bacteria. We developed a panel of synthetic antimicrobial and antibiofilm peptides (SAAPs) with enhanced antimicrobial activities compared to the parent peptide, human antimicrobial peptide LL-37. Our lead peptide SAAP-148 was more efficient in killing bacteria under physiological conditions in vitro than many known preclinical- and clinical-phase antimicrobial peptides. SAAP-148 killed MDR pathogens without inducing resistance, prevented biofilm formation, and eliminated established biofilms and persister cells. A single 4-hour treatment with hypromellose ointment containing SAAP-148 completely eradicated acute and established, biofilm-associated infections with methicillin-resistant Staphylococcus aureus and MDR Acinetobacter baumannii from wounded ex vivo human skin and murine skin in vivo. Together, these data demonstrate that SAAP-148 is a promising drug candidate in the battle against antibiotic-resistant bacteria that pose a great threat to human health.


Chromosome Research | 2010

Stable S/MAR-based episomal vectors are regulated at the chromatin level

Federico Tessadori; Kang Zeng; Erik M. M. Manders; Martijn Riool; Dean A. Jackson; Roel van Driel

Episomal vectors assembled from defined genetic components are a promising alternative to traditional gene therapy vectors that integrate in the host genome and may cause insertional mutations. The vector pEPI-eGFP is stably retained in the episomal state in cultured mammalian cells at low copy number for many generations without integration into the host genome. Although pEPI-eGFP is a fully engineered vector, little is known about how it interacts with the host genome and about the molecular mechanisms that are responsible for its transcriptional activity. We have analyzed the expression of the episomal reporter gene eGFP under conditions that affect the chromatin state of the genome. We have also constructed pEPI derivatives carrying a tandem array of lac operator sequences, which allows in vivo visualization and manipulation of the chromatin state of the episome. We show that changes in chromatin state of both the host and pEPI-eGFP induces changes in episomal gene activity and influences the episome’s nuclear distributions. We conclude that episomal genes are subject to control systems of the host, similarly to their counterparts in the host genome.


European Cells & Materials | 2017

A chlorhexidine-releasing epoxy-based coating on titanium implants prevents Staphylococcus aureus experimental biomaterial-associated infection

Martijn Riool; A. J. Dirks; Valery Jaspers; T. J.A. Loontjens; C. M. van der Loos; Sandrine Florquin; I. Apachitei; L. N.D. Rijk; H. A. Keul; Saj Zaat

Prevention of biomaterial-associated infections (BAI) remains a challenging problem, in particular due to the increased risk of resistance development with the current antibiotic-based strategies. Metallic orthopaedic devices, such as non-cemented implants, are often inserted under high mechanical stress. These non-cemented implants cannot be protected by e.g. antibioticreleasing bone cement or other antimicrobial approaches, such as the use of bioactive glass. Therefore, in order to avoid abrasion during implantation procedures, we developed an antimicrobial coating with great mechanical stability for orthopaedic implants, to prevent Staphylococcus aureus BAI. We incorporated 5 and 10 wt % chlorhexidine in a novel mechanically stable epoxy-based coating, designated CHX5 and CHX10, respectively. The coatings displayed potent bactericidal activity in vitro against S. aureus, with over 80 % of the release (19 µg/cm2 for CHX5 and 41 µg/cm2 for CHX10) occurring within the first 24 h. In mice, the CHX10 coating significantly reduced the number of CFU (colony forming units), both on the implants and in the peri-implant tissues, 1 d after S. aureus challenge. The CHX10-coated implants were well-tolerated by the animals, with no signs of toxicity observed by histological analysis. Moreover, the coating significantly reduced the frequency of culture-positive tissues 1 d, and of culture-positive implants 1 and 4 d after challenge. In summary, the chlorhexidine-releasing mechanically stable epoxy-based CHX10 coating prevented implant colonisation and S. aureus BAI in mice and has good prospects for clinical development.


Biochimica et Biophysica Acta | 2018

Synthetic antimicrobial peptides delocalize membrane bound proteins thereby inducing a cell envelope stress response

Soraya Omardien; Jan W. Drijfhout; Henk van Veen; Soraya Schachtschabel; Martijn Riool; Leendert W. Hamoen; Stanley Brul; Sebastian A. J. Zaat

BACKGROUND Three amphipathic cationic antimicrobial peptides (AMPs) were characterized by determining their effect on Gram-positive bacteria using Bacillus subtilis strain 168 as a model organism. These peptides were TC19 and TC84, derivatives of thrombocidin-1 (TC-1), the major AMPs of human blood platelets, and Bactericidal Peptide 2 (BP2), a synthetic designer peptide based on human bactericidal permeability increasing protein (BPI). METHODS To elucidate the possible mode of action of the AMPs we performed a transcriptomic analysis using microarrays. Physiological analyses were performed using transmission electron microscopy (TEM), fluorescence microscopy and various B. subtilis mutants that produce essential membrane bound proteins fused to green fluorescent protein (GFP). RESULTS The transcriptome analysis showed that the AMPs induced a cell envelope stress response (cell membrane and cell wall). The cell membrane stress response was confirmed with the physiological observations that TC19, TC84 and BP2 perturb the membrane of B. subtilis. Using B. subtilis mutants, we established that the cell wall stress response is due to the delocalization of essential membrane bound proteins involved in cell wall synthesis. Other essential membrane proteins, involved in cell membrane synthesis and metabolism, were also delocalized due to alterations caused by the AMPs. CONCLUSIONS We showed that peptides TC19, TC84 and BP2 perturb the membrane causing essential proteins to delocalize, thus preventing the possible repair of the cell envelope after the initial interference with the membrane. GENERAL SIGNIFICANCE These AMPs show potential for eventual clinical application against Gram-positive bacterial cells and merit further application-oriented investigation.

Collaboration


Dive into the Martijn Riool's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jan W. Drijfhout

Leiden University Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Peter H. Nibbering

Leiden University Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Anna de Breij

Leiden University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Robert A. Cordfunke

Leiden University Medical Center

View shared research outputs
Top Co-Authors

Avatar

I. Apachitei

Delft University of Technology

View shared research outputs
Top Co-Authors

Avatar

L. de Boer

University of Amsterdam

View shared research outputs
Top Co-Authors

Avatar

Amir A. Zadpoor

Delft University of Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge