Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Miguel Ángel Rodríguez-Delgado is active.

Publication


Featured researches published by Miguel Ángel Rodríguez-Delgado.


Journal of Chromatography A | 2010

Carbon nanotubes: Solid-phase extraction

Lidia M. Ravelo-Pérez; Antonio V. Herrera-Herrera; Javier Hernández-Borges; Miguel Ángel Rodríguez-Delgado

Since the first report in 1991, carbon nanotubes (CNTs) have shown great possibilities for a wide variety of processes and applications, which include their use as electrodes, sensors (gas, enzymatic, etc.), nanoprobes, electronic materials, field emitters, etc. The combination of structures, dimensions and topologies has provided physical and chemical attractive properties that are unparalleled by most known materials. Their applications have also reached the Analytical Chemistry field in which CNTs are being used as matrices in matrix assisted laser desorption ionization, stationary phases in either gas chromatography, high performance liquid chromatography or capillary electrochromatography, also as pseudostationary phases in capillary electrophoresis, etc. as well as new solid-phase extraction (SPE) materials. Concerning this last application the number of works has considerably increased in the last five years. This review article pretends to focus on the most important features and different applications of SPE using CNTs (including matrix solid-phase dispersion and solid-phase microextraction) covering articles published since their introduction up to now (September 2009).


Journal of Chromatography A | 2001

Separation of phenolic compounds by high-performance liquid chromatography with absorbance and fluorimetric detection

Miguel Ángel Rodríguez-Delgado; Sabina Malovaná; J.P. Pérez; T. Borges; F. García Montelongo

Phenolic compounds including phenolic aldehydes, acids and flavonoids are separated by high-performance liquid chromatography (HPLC) with analysis time shorter than described in the literature. The use of a fluorescence detector in series with absorbance detector allowed increasing selectivity and sensitivity for the determination of catechin, vanillic acid, syringic acid, epicatechin and trans-resveratrol in wine samples. An optimised sample preparation method using liquid-liquid extraction with diethyl ether at pH 2.0 was used. The optimised method was applied to analyse wine samples with good results.


Analytica Chimica Acta | 2012

Carbon nanotubes applications in separation science: a review.

Antonio V. Herrera-Herrera; Miguel Ángel González-Curbelo; Javier Hernández-Borges; Miguel Ángel Rodríguez-Delgado

Due to the intensive and multidisciplinary research carried out during the last two decades on carbon nanotubes (CNTs), the scientific community understands nowadays much better the chemistry, structure and properties of these interesting materials. In fact, they have found their particular place in a wide number of application fields (nanotechnology, electronics, optics, medicine, etc.) among which Analytical Chemistry is becoming more and more important. The aim of this review is to provide an updated report of the most recent manuscripts (years 2009-2011) regarding the use of CNTs in Separation Science. In particular, the use of CNTs as solid-phase extraction and microextraction sorbents, as part of membranes as well as their use in chromatography and electrophoresis will be discussed and commented. Besides, although not as fully related to Separation Science as the previous techniques, the use of CNTs as laser desorption/ionization substrates has also been considered because of its importance in the field.


Journal of Chromatography A | 2009

Ionic liquid based dispersive liquid–liquid microextraction for the extraction of pesticides from bananas

Lidia M. Ravelo-Pérez; Javier Hernández-Borges; María Asensio-Ramos; Miguel Ángel Rodríguez-Delgado

This paper describes a dispersive liquid-liquid microextraction (DLLME) procedure using room temperature ionic liquids (RTILs) coupled to high-performance liquid chromatography with diode array detection capable of quantifying trace amounts of eight pesticides (i.e. thiophanate-methyl, carbofuran, carbaryl, tebuconazole, iprodione, oxyfluorfen, hexythiazox and fenazaquin) in bananas. Fruit samples were first homogenized and extracted (1g) with acetonitrile and after suitable evaporation and reconstitution of the extract in 10 mL of water, a DLLME procedure using 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM][PF(6)]) as extraction solvent was used. Experimental conditions affecting the DLLME procedure (sample pH, sodium chloride percentage, ionic liquid amount and volume of disperser solvent) were optimized by means of an experimental design. In order to determine the presence of a matrix effect, calibration curves for standards and fortified banana extracts (matrix matched calibration) were studied. Mean recovery values of the extraction of the pesticides from banana samples were in the range of 69-97% (except for thiophanate-methyl and carbofuran, which were 53-63%) with a relative standard deviation lower than 8.7% in all cases. Limits of detection achieved (0.320-4.66 microg/kg) were below the harmonized maximum residue limits established by the European Union (EU). The proposed method, was also applied to the analysis of this group of pesticides in nine banana samples taken from the local markets of the Canary Islands (Spain). To the best of our knowledge, this is the first application of RTILs as extraction solvents for DLLME of pesticides from samples different than water.


Journal of Chromatography A | 2008

Multi-walled carbon nanotubes as efficient solid-phase extraction materials of organophosphorus pesticides from apple, grape, orange and pineapple fruit juices

Lidia M. Ravelo-Pérez; Javier Hernández-Borges; Miguel Ángel Rodríguez-Delgado

Multi-walled carbon nanotubes (MWCNTs) have been used for the first time as solid-phase extraction (SPE) sorbents for the extraction of eight organophosphorus pesticides (i.e. ethoprophos, diazinon, chlorpyriphos-methyl, fenitrothion, malathion, chlorpyriphos, fenamiphos and buprofezin) from different commercial fruit juices (i.e. apple, grape, orange and pineapple). The developed method, which involves SPE and direct gas chromatography with nitrogen phosphorus detection analysis, is very fast, simple and cheap: only 1:1 dilution with Milli-Q water and pH adjustment to 6.0 of 10 mL of juice is necessary prior to a quick MWCNTs-SPE procedure that used only 40 mg of stationary phase (MWCNTs of 10-15 nm o.d., 2-6 nm i.d. and 0.1-10 microm length). Mean recovery values were above 73% for all the pesticides and fruit juices (between 77 and 101% for apple juice, 75 and 103% for grape juice, 73 and 103% for orange juice and 73 and 93% for pineapple juice) with a relative standard deviation (RSD) lower than 8.5% in all cases. Matrix matched calibration was carried out for each sample matrix since statistical differences between the calibration curves constructed is pure solvent and in the reconstructed juice extracts were found. Limits of detection ranged between 1.85 and 7.32 microg/L (which also represents LODs between 1.85 and 7.34 microg/kg) well below the European Union maximum residue limits for the raw fruits. The proposed method, which is demonstrated to be quick, cheap, accurate and highly selective, was also applied to the analysis of this group of pesticides in several commercial juices in which none of the selected pesticides were found.


Analytica Chimica Acta | 2001

Optimisation of sample preparation for the determination of trans-resveratrol and other polyphenolic compounds in wines by high performance liquid chromatography

Sabina Malovaná; F. García Montelongo; J.P. Pérez; Miguel Ángel Rodríguez-Delgado

Abstract Different methods for sample preparation as a preliminary stage for the simultaneous determination of trans -resveratrol and other polyphenolic compounds are compared with the aim to establish the best conditions for the determination of these compounds in wine samples by high performance liquid chromatography (HPLC). Sample preparation using liquid–liquid extraction and solid-phase extraction were compared. Liquid–liquid extraction using as organic solvent diethyl ether at pH 2.0 shows the best results. The dried extract was solved in methanol/water 1:1 (v/v) that improve drastically the separation efficiency. The developed method was applied to the analysis of wines from the Canary Islands.


Journal of Chromatography A | 2011

Ionic liquid-dispersive liquid-liquid microextraction for the simultaneous determination of pesticides and metabolites in soils using high-performance liquid chromatography and fluorescence detection.

María Asensio-Ramos; Javier Hernández-Borges; Teresa M. Borges-Miquel; Miguel Ángel Rodríguez-Delgado

In this work, an ionic liquid-dispersive liquid-liquid microextraction (IL-DLLME) procedure was developed for the extraction of a group of pesticides (carbendazim/benomyl, thiabendazole, fuberidazole, carbaryl and triazophos) and some of their key metabolites in soils (2-aminobenzimidazole, metabolite of carbendazim and 1-naphthol, metabolite of carbaryl) from aqueous soil extracts, using high performance liquid chromatography (HPLC) with fluorescence detection (FD). Analytes were previously extracted from four soils with different physicochemical properties (forestal, ornamental, garden and lapilli soils) by ultrasound-assisted extraction (USE). The IL 1-hexyl-3-methylimidazolium hexafluorophosphate ([HMIm][PF(6)]) and methanol (MeOH) were used as extraction and dispersion solvent, respectively, for the DLLME procedure. Factors affecting IL-DLLME (sample pH, IL amount, volume of dispersion solvent and sodium chloride percentage) were optimized by means of an experimental design, obtaining the most favorable results when using 117.5 mg of IL and 418 μL of MeOH to extract the compounds from the aqueous soil extracts at pH 5.20 containing 30% (w/v) NaCl. Calibration of the USE-IL-DLLME-HPLC-FD method was carried out for every type of soil and accuracy and precision studies were developed at two levels of concentration, finding that no significant differences existed between real and spiked concentrations (Students t test). LODs achieved were in the low ng/g range.


Journal of Chromatography A | 2002

Determination of esters in dry and sweet white wines by headspace solid-phase microextraction and gas chromatography

Juan J. Rodríguez-Bencomo; José Elias Conde; Miguel Ángel Rodríguez-Delgado; Francisco J. García-Montelongo; J.P Pérez-Trujillo

Headspace solid-phase microextraction (HS-SPME) was studied for the high-resolution gas chromatographic (HRGC) analysis of esters in wines. Five different SPME fibers were tested and the influence of different factors such as temperature and time of desorption, extraction time, extraction technique, stirring, sample and vial volume, sugar and ethanol content were studied and optimised using model solutions. The proposed HS-SPME-GC method is an appropriate technique for the quantitative analysis of esters in dry and sweet white wines.


Journal of Pharmaceutical and Biomedical Analysis | 2013

Dispersive liquid-liquid microextraction combined with ultra-high performance liquid chromatography for the simultaneous determination of 25 sulfonamide and quinolone antibiotics in water samples.

Antonio V. Herrera-Herrera; Javier Hernández-Borges; Teresa M. Borges-Miquel; Miguel Ángel Rodríguez-Delgado

In this work, a dispersive liquid-liquid microextraction (DLLME) procedure combined with ultra-high performance liquid chromatography with diode-array detection was developed to determine 25 antibiotics in mineral and run-off waters. Optimum DLLME conditions (5 mL of water at pH=7.6, 20% (w/v) NaCl, 685 μL of CHCl₃ as extractant solvent, and 1250 μL of ACN as disperser solvent) allowed the repeatable, accurate and selective determination of 11 sulfonamides (sulfanilamide, sulfacetamide, sulfadiazine, sulfathiazole, sulfadimidin, sulfamethoxypyridazine, sulfadoxine, sulfamethoxazole, sulfisoxazole, sulfadimethoxine and sulfaquinoxaline) and 14 quinolones (pipemidic acid, marbofloxacin, fleroxacin, levofloxacin, pefloxacin, ciprofloxacin, lomefloxacin, danofloxacin, enrofloxacin, sarafloxacin, difloxacin, moxifloxacin, oxolinic acid and flumequine). The method was validated by means of the obtention of calibration curves of the whole method as well as a recovery study at two levels of concentration. The LODs of the method were in the range 0.35-10.5 μg/L with recoveries between 78% and 117%.


Journal of Chromatography A | 2011

Oxidized multi-walled carbon nanotubes for the dispersive solid-phase extraction of quinolone antibiotics from water samples using capillary electrophoresis and large volume sample stacking with polarity switching

Antonio V. Herrera-Herrera; Lidia M. Ravelo-Pérez; Javier Hernández-Borges; María M. Afonso; J. Antonio Palenzuela; Miguel Ángel Rodríguez-Delgado

In this work, a new method for the determination of eleven quinolone antibiotics (moxifloxacin, lomefloxacin, danofloxacin, ciprofloxacin, levofloxacin, marbofloxacin, enrofloxacin, difloxacin, pefloxacin, oxolinic acid and flumequine) in different water samples using dispersive solid-phase extraction (dSPE) and capillary zone electrophoresis with diode-array detection was developed. Oxidized multi-walled carbon nanotubes (o-MWCNTs) were used for the first time as stationary phases for the off-line preconcentration by dSPE of the antibiotics. A 65 mM phosphate buffer at pH 8.5 was found adequate for analyte separation while large volume sample stacking with polarity switching of the analytes dissolved in water containing 10% (v/v) of acetonitrile was carried out in order to improve the sensitivity. dSPE parameters, such as sample volume and pH, o-MWCNT amount, volume and type of eluent in dSPE were optimized. Application of the developed method to the analysis of spiked Milli-Q, mineral, tap, and wastewater samples resulted in good recoveries values ranging from 62.3 to 116% with relative standard deviation values lower than 7.7% in all cases. Limits of detection were in the range of 28-94 ng/L. The proposed method is very fast, simple, repeatable, accurate and highly selective.

Collaboration


Dive into the Miguel Ángel Rodríguez-Delgado's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Alejandro Cifuentes

Spanish National Research Council

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge