Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Mustafa Demirci is active.

Publication


Featured researches published by Mustafa Demirci.


Journal of Esthetic and Restorative Dentistry | 2013

The Effect of a Modeling Resin and Thermocycling on the Surface Hardness, Roughness, and Color of Different Resin Composites

Safa Tuncer; Mustafa Demirci; Murat Tiryaki; Nimet Ünlü; Omer Uysal

STATEMENT OF PROBLEM The application of modeling resin could affect the surface quality and color of resin composites. PURPOSE To evaluate the effects of modeling resin on the microhardness, roughness, and color of composite restorations, with and without thermocycling. METHODS Sixty disc-shaped specimens for each resin composite were prepared in three groups: Group 1: A resin composite disc was cured against a polyester matrix and finished/polished; Group 2: A composite instrument was wetted with Bisco Modeling Resin (Bisco, Schaumburg, IL, USA) to smooth the composite surface, which was cured against a polyester matrix and finished/polished; Group 3: A composite instrument was wetted with modeling resin to smooth the composite surface, which was cured against a polyester matrix. Microhardness, roughness, and color were measured 24 hours after curing and after 10,000 thermocycles. RESULTS Modeling resin significantly influenced the microhardness of GrandioSO (Voco, Cuxhaven, Germany) and Gradia Direct Posterior (GC America, Alsip, IL, USA), and the surface roughness of GrandioSO, Filtek Silorane (3M ESPE, St Paul, MN, USA), and Aelite All Purpose Body (Bisco) (p < 0.05). The microhardness of the Group 1 resin composites was affected by thermocycling (p < 0.05); however, thermocycling had no significant effect on surface roughness (p > 0.05). Tested composites showed clinically perceptible color changes after thermocycling. In Group 1, Filtek Ultimate (3M ESPE) showed the lowest color change (p < 0.05), and in Group 2, Filtek Silorane showed the highest significant color changes (p < 0.05). CONCLUSIONS Modeling resin did not affect the microhardness, surface roughness, and color of Aelite LS Posterior (Bisco), Filtek Ultimate (3M ESPE), and Clearfil Majesty Esthetic (Kuraray Medical Inc, Tokyo, Japan) specimens. Also, thermocycling process only affected microhardness of tested resin composites. CLINICAL SIGNIFICANCE The effect of modeling resin on surface microhardness, roughness, and color stability of composite materials depends on the type of resin composite. In clinical practice, the adverse effects of modeling resin might be alleviated by a proper finishing and polishing procedure.


Restorative Dentistry and Endodontics | 2015

The effect of different drinks on the color stability of different restorative materials after one month.

Neslihan Tekçe; Safa Tuncer; Mustafa Demirci; Merve Efe Serim; Canan Baydemir

Objectives The aim of this study was to evaluate the effect of three different drinks on the color parameters of four different restorative materials. Materials and Methods Three different composites (Filtek Ultimate Universal Restorative, Filtek Ultimate Flowable, and Filtek Silorane, 3M ESPE) and a polyacid-modified composite resin material (Dyract XP, Dentsply DeTrey GmbH) were evaluated. Eighty-four disc-shaped specimens of 8 mm in diameter and 2 mm in thickness were prepared (n = 21 each). Color coordinates (L*a*b*, ΔL*, Δa*, Δb*, and ΔE*) were measured using a VİTA Easyshade Compact (VİTA Zahnfabrik) after 24 hr of storage (baseline) and after 30 day of storage in three different beverages of black tea, Coca cola, or water (control) (n = 7). In each beverage, the specimens were stored three times a day, one hr each, for 30 day. The color changes (ΔE) were calculated and were analyzed by Kruskal-Wallis and Dunn multiple comparison test. Results The color difference (ΔE*) of the resin materials ranged between 1.31 and 15.28 after 30 day of immersion in the staining solutions. Dyract XP in Coca cola (15.28 ± 2.61) and black tea (12.22 ± 2.73) showed the highest mean ΔE* value after 30 day, followed by Filtek Ultimate Universal Restorative (5.99 ± 1.25) and Filtek Ultimate Flowable (4.71 ± 1.40) in black tea (p < 0.05). Conclusions The compomers displayed unacceptable color changes at the end of 30 day in all beverages. Among resin composites, the silorane based composite exhibited relatively good color stability than the others. Filtek Ultimate Universal Restorative and Filtek Flowable showed similar color changes in all beverages.


Clinical Oral Investigations | 2012

Inhibition of cell survival, viability and proliferation by dentin adhesives after direct and indirect exposure in vitro

Safa Tuncer; Mustafa Demirci; Helmut Schweikl; Mine Erguven; Ayhan Bilir; Aysun Kara Tuncer

ObjectivesThe influence of dentin adhesive systems (Scotchbond Multi-Purpose, XP Bond, Xeno V, Clearfil Protect Bond, AdheSE) on cell survival, viability and proliferation was characterized after direct and indirect exposure using different cell culture techniques.Materials and methodsThe primers and cured bonding parts were directly exposed to cells using cell culture inserts, and complete materials were analyzed in a dentin barrier test. Cell responses were examined in 3T3 mouse fibroblasts after 24- and 72-h exposure periods by the estimation of total cell numbers (survival), apoptosis (viability) and cell proliferation.ResultsCell numbers were effectively reduced by the primers of AdheSE, Protect Bond, and Scotchbond Multi-Purpose as well as XP bond after direct exposure in a cell culture insert test device. Likewise, Scotchbond Multi-Purpose primer induced a rate of apoptosis (93.9%) even higher than detected with Protect Bond primer (91.6%). Cell proliferation was entirely inhibited by primers and by Xp Bond as well. The Scotchbond Multi-Purpose was most cytotoxic in a dentin barrier test device after a 24-h indirect exposure. It also increased the percentage of cells in apoptosis to 15.4% compared to untreated controls.ConclusionUnpolymerized primers of dentin adhesives were more cytotoxic than polymerized bonding counterparts. Moreover, total etch dentin adhesives were more cytotoxic than self-etch adhesives.Clinical relevanceWhen dentin adhesives are used in deep cavities without a protective dentin barrier the leachable hydrophobic and hydrophilic component of dentin adhesive systems can penetrate to the pulp and may induce cytotoxic responses in pulp tissues.


Scanning | 2016

Do matrix metalloproteinase inhibitors improve the bond durability of universal dental adhesives

Neslihan Tekçe; Safa Tuncer; Mustafa Demirci; Sibel Balci

The aim of this study was to evaluate the effects of matrix metalloproteinases (MMPs) inhibitors on the microtensile bond strength (μTBS) and the adhesive-dentin interface of two universal dentin bonding agents, Single Bond Universal and All Bond Universal, after 12 months of water storage. Seventy extracted, caries-free, human third molars were used in this study. Of these, 50 were used for μTBS testing and 20 were used for scanning electron microscopy. The two bonding agents were applied to flat dentin surfaces in five different ways: self-etch mode, etch-and-rinse mode with 37% phosphoric acid, etch-and-rinse mode with phosphoric acid containing 1% benzalkonium chloride, etch-and-rinse mode with phosphoric acid and 2% chlorhexidine, and etch-and-rinse mode with 0.5 M ethylenediaminetetraacetic acid (EDTA) (n = 5 for each bonding agent in each group; N = 50). Half the specimens were subjected to μTBS tests at 24 h, while half were subjected to the tests after 12 months of water storage. For each bonding agent, inhibition, storage, and their interaction effects were tested by two-way analysis of variance and Bonferroni tests. For Single Bond Universal, the benzalkonium chloride (p = 0.024) and chlorhexidine groups (p = 0.033) exhibited significantly higher μTBS values at 24 h compared with the self-etch group. For All Bond Universal, all groups displayed similar bond strengths at 24 h (p > 0.05). After 12 months of water storage, the μTBS values decreased significantly in the benzalkonium chloride group for Single Bond Universal (p = 0.001) and the self-etch (p = 0.029), chlorhexidine (p = 0.046), and EDTA (p = 0.032) groups for All Bond Universal. These results suggest that the immediate dentin bond strength increases when universal bonding systems are applied in the etch-and-rinse mode, although the durability decreases. The use of chlorhexidine and EDTA can increase the bond durability of mild adhesives such as Single Bond Universal. SCANNING 38:535-544, 2016.


European Journal of Dentistry | 2014

Bacterial penetration of restored cavities using two self-etching bonding systems

Nevin Cobanoglu; Fusun Ozer; Mustafa Demirci; Osman Erganis; Satoshi Imazato

Objective: The aim of this study was to investigate the effects of two bonding systems, with and without antibacterial monomers, on marginal bacterial and dye leakage. Materials and Methods: Class V cavities were prepared in extracted teeth for a bacterial leakage test, and the teeth were sterilized using a steam autoclave. Four cavities were not restored for the controls, and the other teeth were divided into two groups (n = 16 cavities each): Clearfil Protect Bond group (CPB) and Clearfil SE Bond group (CSE). After application of the bonding agent, the cavities were restored using a composite resin (Clearfil AP-X). The teeth were thermocycled, stored in a broth culture of 1.56 Χ 108 colony forming units (CFU)/ml of Streptococcus mutans at 37°C for 10 days, and subsequently processed for bacterial staining. Sections from the demineralized teeth were evaluated under a light microscope. In the dye leakage test, the cavities were restored as described in the bacterial penetration test. After thermocycling, the teeth were immersed in 5% basic fuchsin for 24 h, and then divided in half and observed under a stereomicroscope. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U-tests (P = 0.05). Results: The bacterial stain was detected at the cavity wall of five cavities in both bonding systems. Additionally, two cavities in the CSE group, one cavity in the CPB group, and all control cavities showed bacterial staining within the cut dentinal tubules. Dye staining at the axial cavity wall was detected in only three of the teeth for both bonding systems. Conclusion: The bonding systems used in this study provided an acceptable marginal seal to prevent bacterial and dye leakage.


Dental Materials Journal | 2017

The effect of surface sealant application and accelerated aging on posterior restorative surfaces: An SEM and AFM study

Neslihan Tekçe; Kanşad Pala; Safa Tuncer; Mustafa Demirci

The purpose of this study was to evaluate the effect of surface sealant application and 10,000 thermocycles on the surface roughness and microhardness of different resin composite systems. A micro-hybrid (G Aenial Posterior), a nano-hybrid (Clearfil Majesty Posterior), a nano-fill (Filtek Ultimate Universal Restorative, Enamel Shade), and a bulk-fill resin composite (Filtek Bulk Fill Posterior Restorative) were used for the study. Specimens were evaluated at 24 h, after application of the surface sealant Fortify Plus, and after thermocycling. Data were analyzed using two-way repeated measures of analysis of variance (ANOVA) and a posthoc Bonferroni test (p<0.05). Surface roughness values of G Aenial Posterior and Filtek Ultimate Universal Restorative increased significantly after surface sealant application. However, neither surface sealant application nor thermocycling had a significant effect on composite microhardness values except Filtek Ultimate Universal Restorative (p>0.05).


Dental Materials Journal | 2016

Evaluation of the surface hardness, roughness, gloss and color of composites after different finishing/polishing treatments and thermocycling using a multitechnique approach

Kanşad Pala; Neslihan Tekçe; Safa Tuncer; Merve Efe Serim; Mustafa Demirci

The objectives of this study were to evaluate the mechanical and physical properties of resin composites. The materials evaluated were the Clearfil Majesty Posterior, Filtek Z550 and G-aenial Posterior composites. A total of 189 specimens were fabricated for microhardness, roughness, gloss and color tests. The specimens were divided into three finishing and polishing systems: Enhance, OneGloss and Sof-Lex Spiral. Microhardness, roughness, gloss and color were measured after 24 h and after 10,000 thermocycles. Two samples from each group were evaluated using SEM and AFM. G-aenial Posterior exhibited the lowest microhardness values. The mean roughness ranged from 0.37 to 0.61 µm. The smoothest surfaces were obtained with Sof-Lex Spiral for each material. G-aenial Posterior with Enhance was determined to be the glossiest surfaces. All of the materials exhibited similar ΔE values ranging between 1.69 and 2.75. Sof-Lex Spiral discs could be used successfully to polish composites.


Journal of Clinical and Experimental Dentistry | 2017

Flexural strength and microhardness of anterior composites after accelerated aging

Kanşad Pala; Neslihan Tekçe; Safa Tuncer; Mustafa Demirci; Fatih Öznurhan; Merve Efe Serim

Background This study aimed to evaluate the flexural strength and microhardness of three different anterior composites after 10 000 thermocycles. Material and Methods The mechanical properties of a nano-fill composite (Filtek Ultimate Universal Restorative (FUR) (Enamel)), a nano-hybrid composite (Clearfil Majesty ES2 (ES2) (Enamel)), and a micro-hybrid composite (G Aenial Anterior (GAA)) were investigated in this study. For the microhardness test, 8-mm diameter and 2-mm thickness composite discs were used (n = 10), and for the flexural strength test, 25x2x2 mm bar-shaped specimens were prepared (n = 13). The specimens were tested at 24 h and after 10 000 thermocycles. Data were analyzed using two-way analysis of variance and the post-hoc Tukey test (p < .05). Correlations between hardness and flexural strength were calculated using Pearson’s correlation analysis. Results There was a significant difference in the microhardness values of the materials (p < .05). FUR exhibited significantly higher microhardness than ES2 and GAA. However, the flexural strength of three composites was statistically similar at 24 h (p > .05). Pearson correlation analysis revealed that there was a negative relationship between the mean hardness and flexural strength values (correlation coefficient = -0.367, p = .043). After 10 000 thermocycles, microhardness values of each material and flexural strength of ES2 and GAA decreased significantly according to 24 h. Conclusions The nano-fill composite FUR displayed significantly higher microhardness values. However, each resin composite was statistically similar for flexural strength values. Ten thousand thermocycles significantly affected microhardness and flexural strength. Key words:Flexural strength, microhardness, anterior composites.


Australian Endodontic Journal | 2017

Influence of polymerisation method and type of fibre on fracture strength of endodontically treated teeth

Neslihan Tekçe; Kanşad Pala; Safa Tuncer; Mustafa Demirci; Merve Efe Serim

The aim of this study was to investigate (i) the effect of direct or indirect polymerisation of adhesive-impregnated ribbon fibre under 4-mm bulk-filled composites on fracture strength; (ii) to compare polyethylene ribbon fibre-reinforcement composites with short fibre-reinforced composite; and (iii) the effectiveness of polyethylene ribbon fibre according to the restorative materials used (low-viscous bulk-fill composite, high-viscous flowable composite or conventional paste composite). Seventy molars were divided into seven groups; (groups 1-2) Ribbond-reinforced Surefil-SDR; (group 3) Ribbond-reinforced G Aenial Flo; (group 4) Ribbond-reinforced G Aenial Posterior; (group 5) short fibre-reinforced composite everX Posterior; (group 6) unfilled cavity; (group 7) intact teeth. Ribbond was adopted to cavity walls by impregnating an adhesive and using a flowable composite. In group 1, adhesive-impregnated Ribbond was polymerised directly using a light-curing-unit, and indirectly in group 2 under 4-mm bulk-filled composite. Direct or indirect polymerisation of adhesive impregnated ribbon fibre under 4-mm bulk-filled composite did not change the fracture strength results. Polyethylene ribbon fibre-reinforced groups (groups 1-4) and short fibre-reinforced composite group (group 5) displayed similar results. Polyethylene ribbon fibre can be used safely under 4-mm bulk-filled composites. Ribbond-reinforced low-viscous bulk-fill, high-viscous flowable, and conventional paste composite exhibited similar fracture strength results.


Biotechnology & Biotechnological Equipment | 2015

Microtensile bond strength and sealing efficiency of all-in-one self-etching adhesives

Neslihan Tekçe; Mustafa Demirci; Safa Tuncer; Omer Uysal

This study aimed to evaluate the microtensile bond strength and amount of microleakage with self-etch adhesives. For the bond strength study, 50 human third molars were randomly assigned to five groups according to the adhesive system used. In each group, half of the specimens were subjected to the microtensile test immediately after the bonding procedures and tooth sectioning, while the remaining half were subjected to the test after storage in distilled water for 3 months. For the microleakage study, following the preparation and restoration of class V cavities, 70 human molars were divided into two groups for the five adhesives; the specimens in one group were stored in distilled water for 24 h and those in the other group were stored for 3 months. In both groups, the teeth were sectioned and evaluated for dye penetration after the storage time. After 24 h, the microtensile bond strengths in descending order were as follows: Clearfil SE Bond > G Aenial Bond > Optibond All-in-One (AiO) > Adper Prompt L Pop (hereafter L Pop) > Futurabond M. After 3 months, the µTBS of all five bonding agents was decreased, although the decrease was significant only for L Pop, which showed the highest scores for leakage around the enamel margins, whereas Futurabond M showed the highest scores for leakage around the gingival margins. After 3 months, the microleakages scores significantly increased for G Aenial Bond, Futurabond M and OptibondAiO.

Collaboration


Dive into the Mustafa Demirci's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge