Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Safa Tuncer is active.

Publication


Featured researches published by Safa Tuncer.


Journal of Endodontics | 2012

Effect of different final irrigation solutions on dentinal tubule penetration depth and percentage of root canal sealer.

Aysun Kara Tuncer; Safa Tuncer

INTRODUCTION The purpose of this study was to evaluate the effects of different solutions used for final irrigation on sealer penetration into dentinal tubules. METHODS Thirty-two recently extracted human mandibular premolar teeth were treated with sodium hypochlorite (NaOCl) irrigation. The samples were divided into 4 groups according to the final irrigation solution used: (1) the EDTA group: 17% EDTA + 2.5% NaOCl, (2) the maleic acid (MA) group: 7% MA + 2.5% NaOCl, (3) the citric acid (CA) group: 10% CA + 2.5% NaOCl, and (4) the control group: 2.5% NaOCl. All teeth were obturated using the cold lateral condensation technique with gutta-percha and AH 26 sealer (Dentsply; DeTrey, Konstanz, Germany) labeled with fluorescent dye. The teeth were sectioned at distances of 2, 5, and 8 mm from the root apex. Total percentage and maximum depth of sealer penetration were measured using confocal laser scanning microscopy. RESULTS The Kruskal-Wallis analysis results showed that there was a significant difference in the percentage and maximum depth of sealer penetration among all groups in all sections (P < .05).The coronal sections in each group showed a significantly higher percentage and maximum depth of sealer penetration than did the apical and middle sections (P < .05). CONCLUSIONS Final irrigation with EDTA, MA, and CA after the use of NaOCl affected sealer penetration. However, there was no significant difference between these experimental groups (EDTA, MA, and CA) in all sections.


Journal of Esthetic and Restorative Dentistry | 2013

The Effect of a Modeling Resin and Thermocycling on the Surface Hardness, Roughness, and Color of Different Resin Composites

Safa Tuncer; Mustafa Demirci; Murat Tiryaki; Nimet Ünlü; Omer Uysal

STATEMENT OF PROBLEM The application of modeling resin could affect the surface quality and color of resin composites. PURPOSE To evaluate the effects of modeling resin on the microhardness, roughness, and color of composite restorations, with and without thermocycling. METHODS Sixty disc-shaped specimens for each resin composite were prepared in three groups: Group 1: A resin composite disc was cured against a polyester matrix and finished/polished; Group 2: A composite instrument was wetted with Bisco Modeling Resin (Bisco, Schaumburg, IL, USA) to smooth the composite surface, which was cured against a polyester matrix and finished/polished; Group 3: A composite instrument was wetted with modeling resin to smooth the composite surface, which was cured against a polyester matrix. Microhardness, roughness, and color were measured 24 hours after curing and after 10,000 thermocycles. RESULTS Modeling resin significantly influenced the microhardness of GrandioSO (Voco, Cuxhaven, Germany) and Gradia Direct Posterior (GC America, Alsip, IL, USA), and the surface roughness of GrandioSO, Filtek Silorane (3M ESPE, St Paul, MN, USA), and Aelite All Purpose Body (Bisco) (p < 0.05). The microhardness of the Group 1 resin composites was affected by thermocycling (p < 0.05); however, thermocycling had no significant effect on surface roughness (p > 0.05). Tested composites showed clinically perceptible color changes after thermocycling. In Group 1, Filtek Ultimate (3M ESPE) showed the lowest color change (p < 0.05), and in Group 2, Filtek Silorane showed the highest significant color changes (p < 0.05). CONCLUSIONS Modeling resin did not affect the microhardness, surface roughness, and color of Aelite LS Posterior (Bisco), Filtek Ultimate (3M ESPE), and Clearfil Majesty Esthetic (Kuraray Medical Inc, Tokyo, Japan) specimens. Also, thermocycling process only affected microhardness of tested resin composites. CLINICAL SIGNIFICANCE The effect of modeling resin on surface microhardness, roughness, and color stability of composite materials depends on the type of resin composite. In clinical practice, the adverse effects of modeling resin might be alleviated by a proper finishing and polishing procedure.


Restorative Dentistry and Endodontics | 2015

The effect of different drinks on the color stability of different restorative materials after one month.

Neslihan Tekçe; Safa Tuncer; Mustafa Demirci; Merve Efe Serim; Canan Baydemir

Objectives The aim of this study was to evaluate the effect of three different drinks on the color parameters of four different restorative materials. Materials and Methods Three different composites (Filtek Ultimate Universal Restorative, Filtek Ultimate Flowable, and Filtek Silorane, 3M ESPE) and a polyacid-modified composite resin material (Dyract XP, Dentsply DeTrey GmbH) were evaluated. Eighty-four disc-shaped specimens of 8 mm in diameter and 2 mm in thickness were prepared (n = 21 each). Color coordinates (L*a*b*, ΔL*, Δa*, Δb*, and ΔE*) were measured using a VİTA Easyshade Compact (VİTA Zahnfabrik) after 24 hr of storage (baseline) and after 30 day of storage in three different beverages of black tea, Coca cola, or water (control) (n = 7). In each beverage, the specimens were stored three times a day, one hr each, for 30 day. The color changes (ΔE) were calculated and were analyzed by Kruskal-Wallis and Dunn multiple comparison test. Results The color difference (ΔE*) of the resin materials ranged between 1.31 and 15.28 after 30 day of immersion in the staining solutions. Dyract XP in Coca cola (15.28 ± 2.61) and black tea (12.22 ± 2.73) showed the highest mean ΔE* value after 30 day, followed by Filtek Ultimate Universal Restorative (5.99 ± 1.25) and Filtek Ultimate Flowable (4.71 ± 1.40) in black tea (p < 0.05). Conclusions The compomers displayed unacceptable color changes at the end of 30 day in all beverages. Among resin composites, the silorane based composite exhibited relatively good color stability than the others. Filtek Ultimate Universal Restorative and Filtek Flowable showed similar color changes in all beverages.


Clinical Oral Investigations | 2012

Inhibition of cell survival, viability and proliferation by dentin adhesives after direct and indirect exposure in vitro

Safa Tuncer; Mustafa Demirci; Helmut Schweikl; Mine Erguven; Ayhan Bilir; Aysun Kara Tuncer

ObjectivesThe influence of dentin adhesive systems (Scotchbond Multi-Purpose, XP Bond, Xeno V, Clearfil Protect Bond, AdheSE) on cell survival, viability and proliferation was characterized after direct and indirect exposure using different cell culture techniques.Materials and methodsThe primers and cured bonding parts were directly exposed to cells using cell culture inserts, and complete materials were analyzed in a dentin barrier test. Cell responses were examined in 3T3 mouse fibroblasts after 24- and 72-h exposure periods by the estimation of total cell numbers (survival), apoptosis (viability) and cell proliferation.ResultsCell numbers were effectively reduced by the primers of AdheSE, Protect Bond, and Scotchbond Multi-Purpose as well as XP bond after direct exposure in a cell culture insert test device. Likewise, Scotchbond Multi-Purpose primer induced a rate of apoptosis (93.9%) even higher than detected with Protect Bond primer (91.6%). Cell proliferation was entirely inhibited by primers and by Xp Bond as well. The Scotchbond Multi-Purpose was most cytotoxic in a dentin barrier test device after a 24-h indirect exposure. It also increased the percentage of cells in apoptosis to 15.4% compared to untreated controls.ConclusionUnpolymerized primers of dentin adhesives were more cytotoxic than polymerized bonding counterparts. Moreover, total etch dentin adhesives were more cytotoxic than self-etch adhesives.Clinical relevanceWhen dentin adhesives are used in deep cavities without a protective dentin barrier the leachable hydrophobic and hydrophilic component of dentin adhesive systems can penetrate to the pulp and may induce cytotoxic responses in pulp tissues.


Scanning | 2016

Do matrix metalloproteinase inhibitors improve the bond durability of universal dental adhesives

Neslihan Tekçe; Safa Tuncer; Mustafa Demirci; Sibel Balci

The aim of this study was to evaluate the effects of matrix metalloproteinases (MMPs) inhibitors on the microtensile bond strength (μTBS) and the adhesive-dentin interface of two universal dentin bonding agents, Single Bond Universal and All Bond Universal, after 12 months of water storage. Seventy extracted, caries-free, human third molars were used in this study. Of these, 50 were used for μTBS testing and 20 were used for scanning electron microscopy. The two bonding agents were applied to flat dentin surfaces in five different ways: self-etch mode, etch-and-rinse mode with 37% phosphoric acid, etch-and-rinse mode with phosphoric acid containing 1% benzalkonium chloride, etch-and-rinse mode with phosphoric acid and 2% chlorhexidine, and etch-and-rinse mode with 0.5 M ethylenediaminetetraacetic acid (EDTA) (n = 5 for each bonding agent in each group; N = 50). Half the specimens were subjected to μTBS tests at 24 h, while half were subjected to the tests after 12 months of water storage. For each bonding agent, inhibition, storage, and their interaction effects were tested by two-way analysis of variance and Bonferroni tests. For Single Bond Universal, the benzalkonium chloride (p = 0.024) and chlorhexidine groups (p = 0.033) exhibited significantly higher μTBS values at 24 h compared with the self-etch group. For All Bond Universal, all groups displayed similar bond strengths at 24 h (p > 0.05). After 12 months of water storage, the μTBS values decreased significantly in the benzalkonium chloride group for Single Bond Universal (p = 0.001) and the self-etch (p = 0.029), chlorhexidine (p = 0.046), and EDTA (p = 0.032) groups for All Bond Universal. These results suggest that the immediate dentin bond strength increases when universal bonding systems are applied in the etch-and-rinse mode, although the durability decreases. The use of chlorhexidine and EDTA can increase the bond durability of mild adhesives such as Single Bond Universal. SCANNING 38:535-544, 2016.


Journal of Adhesion Science and Technology | 2014

Correlation between sealer penetration into dentinal tubules and bond strength of two new calcium silicate-based and an epoxy resin-based, endodontic sealer

Aysun Kara Tuncer; Safa Tuncer; S. Selçuk Gökyay

The relationship between sealer penetration into dentinal tubules and the bond strength of two new calcium silicate-based and epoxy resin-based endodontic sealers was evaluated. Thirty recently extracted human maxillary incisors were instrumented and divided into three groups according to the sealer used: (1) AH Plus; (2) iRoot SP; and (3) MTA Fillapex. Sealer penetration into dentinal tubules was measured using CLSM. Then, a universal testing machine was used to compare the push-out bond strengths of the sealers to the root canal dentin. AH Plus and MTA Fillapex exhibited significantly higher sealer penetration than iRoot SP did (p > .05). The push-out bond strengths of AH Plus and iRoot SP were higher than that of MTA Fillapex. We concluded that greater penetration of the sealer into the dentinal tubules was not associated with higher bond strength among the three sealers tested.


Dental Materials Journal | 2017

The effect of surface sealant application and accelerated aging on posterior restorative surfaces: An SEM and AFM study

Neslihan Tekçe; Kanşad Pala; Safa Tuncer; Mustafa Demirci

The purpose of this study was to evaluate the effect of surface sealant application and 10,000 thermocycles on the surface roughness and microhardness of different resin composite systems. A micro-hybrid (G Aenial Posterior), a nano-hybrid (Clearfil Majesty Posterior), a nano-fill (Filtek Ultimate Universal Restorative, Enamel Shade), and a bulk-fill resin composite (Filtek Bulk Fill Posterior Restorative) were used for the study. Specimens were evaluated at 24 h, after application of the surface sealant Fortify Plus, and after thermocycling. Data were analyzed using two-way repeated measures of analysis of variance (ANOVA) and a posthoc Bonferroni test (p<0.05). Surface roughness values of G Aenial Posterior and Filtek Ultimate Universal Restorative increased significantly after surface sealant application. However, neither surface sealant application nor thermocycling had a significant effect on composite microhardness values except Filtek Ultimate Universal Restorative (p>0.05).


Dental Materials Journal | 2016

Evaluation of the surface hardness, roughness, gloss and color of composites after different finishing/polishing treatments and thermocycling using a multitechnique approach

Kanşad Pala; Neslihan Tekçe; Safa Tuncer; Merve Efe Serim; Mustafa Demirci

The objectives of this study were to evaluate the mechanical and physical properties of resin composites. The materials evaluated were the Clearfil Majesty Posterior, Filtek Z550 and G-aenial Posterior composites. A total of 189 specimens were fabricated for microhardness, roughness, gloss and color tests. The specimens were divided into three finishing and polishing systems: Enhance, OneGloss and Sof-Lex Spiral. Microhardness, roughness, gloss and color were measured after 24 h and after 10,000 thermocycles. Two samples from each group were evaluated using SEM and AFM. G-aenial Posterior exhibited the lowest microhardness values. The mean roughness ranged from 0.37 to 0.61 µm. The smoothest surfaces were obtained with Sof-Lex Spiral for each material. G-aenial Posterior with Enhance was determined to be the glossiest surfaces. All of the materials exhibited similar ΔE values ranging between 1.69 and 2.75. Sof-Lex Spiral discs could be used successfully to polish composites.


Journal of Adhesion Science and Technology | 2015

The effect of bulk-fill flowable composites on the fracture resistance and cuspal deflection of endodontically treated premolars

Tuğba Toz; Safa Tuncer; Funda Öztürk Bozkurt; Aysun Kara Tuncer; Harika Gozukara Bag

The aim of this study was to evaluate the effect of bulk-fill flowable composites on cuspal deflection and fracture resistance of endodontically treated teeth. Forty-two maxillary premolars were subjected to endodontic treatment followed by the preparation of mesioocclusodistal cavities. Teeth were divided into six groups according to restorative materials as follows: Group 1: Clearfil Majesty Flow and Clearfil Majesty Posterior; Group 2: Venus Bulk Fill and Clearfil Majesty Posterior; Group 3: Clearfil Majesty Posterior; Group 4: Vertise Flow and Clearfil Majesty Posterior; Group 5: SDR and Clearfil Majesty Posterior; and Group 6: x-tra base and Clearfil Majesty Posterior. A single-step self-etch adhesive (OptiBond All-in-One) was applied to all groups, except Group 4. The cavities were restored with a centripetal incremental insertion technique and flowable composites using a 2-mm-thick base material, except for Group 3. The distance between cusp tips was measured before and after the cavity preparations, after the restorations, and after thermal cyclus with a digital micrometer. After measuring, each tooth was subjected to compressive loading with a stainless steel ball (4 mm diameter) perpendicular to the occlusal surface with a crosshead speed of 1 mm/min, and mean loads necessary to fracture were recorded in Newtons. The data were statistically analyzed by Kruskal–Wallis test. No statistically significant differences were found between groups in fracture strength or cuspal deflections (p > 0.05). Bulk-fill flowable composite bases did not change the cuspal deflection or fracture resistance of endodontically treated teeth, compared with that of a conventional flowable base and conventional resin composite.


Journal of Clinical and Experimental Dentistry | 2017

Flexural strength and microhardness of anterior composites after accelerated aging

Kanşad Pala; Neslihan Tekçe; Safa Tuncer; Mustafa Demirci; Fatih Öznurhan; Merve Efe Serim

Background This study aimed to evaluate the flexural strength and microhardness of three different anterior composites after 10 000 thermocycles. Material and Methods The mechanical properties of a nano-fill composite (Filtek Ultimate Universal Restorative (FUR) (Enamel)), a nano-hybrid composite (Clearfil Majesty ES2 (ES2) (Enamel)), and a micro-hybrid composite (G Aenial Anterior (GAA)) were investigated in this study. For the microhardness test, 8-mm diameter and 2-mm thickness composite discs were used (n = 10), and for the flexural strength test, 25x2x2 mm bar-shaped specimens were prepared (n = 13). The specimens were tested at 24 h and after 10 000 thermocycles. Data were analyzed using two-way analysis of variance and the post-hoc Tukey test (p < .05). Correlations between hardness and flexural strength were calculated using Pearson’s correlation analysis. Results There was a significant difference in the microhardness values of the materials (p < .05). FUR exhibited significantly higher microhardness than ES2 and GAA. However, the flexural strength of three composites was statistically similar at 24 h (p > .05). Pearson correlation analysis revealed that there was a negative relationship between the mean hardness and flexural strength values (correlation coefficient = -0.367, p = .043). After 10 000 thermocycles, microhardness values of each material and flexural strength of ES2 and GAA decreased significantly according to 24 h. Conclusions The nano-fill composite FUR displayed significantly higher microhardness values. However, each resin composite was statistically similar for flexural strength values. Ten thousand thermocycles significantly affected microhardness and flexural strength. Key words:Flexural strength, microhardness, anterior composites.

Collaboration


Dive into the Safa Tuncer's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge