Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Myung Ho Rho is active.

Publication


Featured researches published by Myung Ho Rho.


Thyroid | 2009

Ultrasound-guided fine-needle aspiration biopsy of thyroid nodules: comparison in efficacy according to nodule size.

Dong-Wook Kim; Eun Joo Lee; Sang Hyo Kim; Tae Hyun Kim; Sang Hyub Lee; Dae Hwan Kim; Myung Ho Rho

BACKGROUND The objective of this study was to compare the efficacy and procedure time of ultrasound-guided fine-needle aspiration biopsy (US-FNAB) of thyroid nodules, according to the nodule size. METHODS US-FNABs of thyroid nodules performed between June 2007 and December 2007 were studied. We divided these patients into three groups according to the largest diameter of their nodules. Group A consisted of patients with thyroid nodules less than or equal to 5 mm, group B of patients with thyroid nodules greater than 5 mm and less than or equal to 10 mm, and group C of patients with thyroid nodules greater than 10 mm. We retrospectively reviewed the cytopathology results and complications in all three patient groups and measured the separate, total US-FNAB procedure time for each of 20 randomly selected thyroid nodules. RESULTS US-FNAB was performed on 438 thyroid nodules in 253 patients. In groups A, B, and C, the adequacy rates from the first US-FNAB were 79.6% (90/113), 90.6% (125/138), and 95.2% (178/187), respectively. In groups A, B, and C, 113, 138, and 187 thyroid nodules in 100, 120, and 169 patients, respectively, revealed 59, 75, and 126 benign; 12, 11, and 9 suspicious for malignancy; 9, 32, and 29 malignant; 10, 7, and 14 inderminate for malignancy; and 23, 13, and 9 inadequate on the first US-FNAB. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were determined to be 85.7%, 100%, 100%, 94.9%, and 96.1% in group A; 97.7%, 100%, 100%, 98.7%, and 99.1% in group B; and 100%, 99.2%, 97.1%, 100%, and 99.4% in group C. The mean procedure times in groups A, B, and C were 2 minutes 33 seconds, 1 minute 50 seconds, and 1 minute 32 seconds, respectively. There were no significant patient complications in any of the three patient groups. CONCLUSIONS US-FNAB of thyroid nodules smaller than 5 mm in maximum diameter was less successful, and the sensitivity was lower than those of nodules larger than 5 mm. We considered, however, that the sampling adequacy and efficacy of US-FNAB of thyroid nodules less than 5 mm in maximum diameter was satisfactory in our series and should be similar in other centers with similar characteristics to ours.


British Journal of Radiology | 2013

A practical MRI grading system for cervical foraminal stenosis based on oblique sagittal images

Hee-Jin Park; Kim Ss; So Yeon Lee; Park Nh; Eun Chul Chung; Myung Ho Rho; Heon-Ju Kwon; S H Kook

OBJECTIVE To propose a new and practical MRI grading method for cervical neural foraminal stenosis and to evaluate its reproducibility. METHODS We evaluated 50 patients (37 males and 13 females, mean age 49 years) who visited our institution and underwent oblique sagittal MRI of the cervical spine. A total of 300 foramina and corresponding nerve roots in 50 patients were qualitatively analysed from C4-5 to C6-7. We assessed the grade of cervical foraminal stenosis at the maximal narrowing point according to the new grading system based on T2 weighted oblique sagittal images. The incidence of each of the neural foraminal stenosis grades according to the cervical level was analysed by χ(2) tests. Intra- and interobserver agreements between two radiologists were analysed using kappa statistics. Kappa value interpretations were poor (κ<0.1), slight (0.1≤κ≤0.2), fair (0.2<κ≤0.4), moderate (0.4<κ≤0.6), substantial (0.6<κ≤0.8) and almost perfect (0.8<κ≤1.0). RESULTS Significant stenoses (Grades 2 and 3) were rarely found at the C4-5 level. The incidence of Grade 3 at the C5-6 level was higher than that at other levels, a difference that was statistically significant. The overall intra-observer agreement according to the cervical level was almost perfect. The agreement at each level was almost perfect, except for only substantial agreement at the right C6-7 by Reader 2. No statistically significant differences were seen according to the cervical level. Overall kappa values of interobserver agreement according to the cervical level were almost perfect. In addition, the agreement of each level was almost perfect. Overall intra- and interobserver agreement for the presence of foraminal stenosis (Grade 0 vs Grades 1, 2 and 3) and for significant stenosis (Grades 0 and 1 vs Grades 2 and 3) showed similar results and were almost perfect. However, only substantial agreement was seen in the right C6-7. CONCLUSION A new grading system for cervical foraminal stenosis based on oblique sagittal MRI provides reliable assessment and good reproducibility. This new grading system is a useful and easy method for the objective evaluation of cervical neural foraminal stenosis by radiologists and clinicians. ADVANCES IN KNOWLEDGE The use of the new grading system for cervical foraminal stenosis based on oblique sagittal MRI can be a useful method for evaluating cervical neural foraminal stenosis.


British Journal of Radiology | 2012

Ultrasonography-guided ethanol ablation of predominantly solid thyroid nodules: a preliminary study for factors that predict the outcome.

D W Kim; Myung Ho Rho; Hee-Jin Park; H J Kwag

OBJECTIVES The aim of this study was to evaluate the success rate in ultrasonography-guided ethanol ablation (EA) of benign, predominantly solid thyroid nodules and to assess the value of colour Doppler ultrasonography in prediction of its success. METHODS From January 2008 to June 2009, 30 predominantly solid thyroid nodules in 27 patients were enrolled. Differences in the success rate of EA were assessed according to nodule vascularity, nodule size, ratio of cystic component, amount of injected ethanol, degree of intranodular echo-staining just after ethanol injection and the number of EA sessions. RESULTS On follow-up ultrasonography after EA for treatment of thyroid nodules, 16 nodules showed an excellent response (90% or greater decrease in volume) and 2 nodules showed a good response (50-90% decrease in volume) on follow-up ultrasonography. However, 5 nodules showed an incomplete response (10-50% decrease in volume) and 7 nodules showed a poor response (10% or less decrease in volume). Statistical analysis revealed a significant association of nodule vascularity (p=0.002) and degree of intranodular echo-staining just after ethanol injection (p=0.003) with a successful outcome; however, no such association was observed with regard to nodule size, ratio of cystic component, amount of infused ethanol and the number of EA sessions. No serious complications were observed during or after EA. CONCLUSION The success rate of EA was 60%, and nodule vascularity and intranodular echo-staining on colour Doppler ultrasonography were useful in predicting the success rate of EA for benign, predominantly solid thyroid nodules.


British Journal of Radiology | 2012

Medial meniscal root tears and meniscal extrusion transverse length ratios on MRI

Hee-Jin Park; Kim Ss; So Yeon Lee; Yoon Jung Choi; Eun Chul Chung; Myung Ho Rho; Kwag Hj

OBJECTIVE To evaluate the clinical utility of the meniscal extrusion transverse ratio of the medial meniscus in the diagnosis of meniscal root tear compared with the gold standard of arthroscopic diagnosis. METHODS This retrospective study sample included 32 males and 35 females who underwent MRI at our institution. There were 24 meniscal root tear cases. The control groups were 18 cases of medial meniscal tears without root tears and 25 cases of negative meniscal findings on arthroscopy. Meniscal extrusion (L) and maximal transverse lengths (T) of the medial meniscus were measured, and L/T ratios were calculated. These results were correlated with arthroscopic findings and analysed statistically. With arthroscopic findings used as the standard of reference, the sensitivity and specificity of 10%, 11% and 12% extrusion thresholds, and 3 mm of medial meniscal extrusion (MME) as diagnostic thresholds, were calculated. RESULTS The mean length of the meniscal extrusions of meniscal root tears was twice as long as the control group. The mean L/T ratio of the meniscal root tears was approximately 13%, while those of the control groups were 5%. The differences in the L and L/T between the meniscal root tears and normal and meniscal root tears and other meniscal tears were statistically significant (p<0.001), but those between normal and other meniscal tears were not. The best diagnostic discrimination was achieved using an extrusion ratio threshold of 10% (79% sensitivity, 86% specificity). The 3 mm of MME threshold demonstrated high specificity (98%), but not high sensitivity (54%). CONCLUSION The mean L/T ratio of the meniscal root tears was approximately 13% and was statistically significant. The best diagnostic discrimination was achieved using an extrusion ratio threshold of 10%. Advances in knowledge The use of the L/T ratio in combination with MME can be a useful method for evaluating medial meniscal root tears.


British Journal of Radiology | 2016

Usefulness of the fast spin-echo three-point Dixon (mDixon) image of the knee joint on 3.0-T MRI: comparison with conventional fast spin-echo T2 weighted image

Hee J Park; So Y Lee; Myung Ho Rho; Eun Chul Chung; Jin H Ahn; Jai H Park; In S Lee

OBJECTIVE To compare the quality of two different imaging methods, three-point Dixon (mDixon) and fast spin-echo (FSE) T2 weighted image (T2WI) [and fat suppression (FS) T2WI], and to assess the utility of mDixon for the imaging of knee joint pathology. METHODS This retrospective study included 66 patients who underwent both mDixon and FSE T2WI (and FS T2WI) of the knee joint. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the two sequences at the articular cartilage and ligament were measured. Two radiologists independently evaluated the anatomic identification score and diagnostic performances of the two sequences. RESULTS The mean SNRs and CNRs of the patellar cartilage, femoral cartilage and anterior cruciate ligament (ACL) were significantly higher on T2WI and FS T2WI than on mDixon imaging, with the exception of the mean SNR of ACL on in-phase images. Most of the anatomic identification scores did not show significant differences, except for inferiorities of the in-phase mDixon in the evaluation of the cruciate ligament. There were no significant differences in sensitivity, specificity and accuracy between mDixon and T2WI regarding diagnostic performance. CONCLUSION mDixon images have equivalent anatomic identification ability with the exception of cruciate ligament delineation on in-phase images and have a diagnostic performance comparable with that of FSE T2WI for meniscal, cartilage and ligament injuries of the knee joint. There would be a net saving in time, if mDixon was the only sequence used. ADVANCES IN KNOWLEDGE The mDixon images have equivalent anatomic identification abilities, with the exception of cruciate ligament delineation on in-phase images and have a diagnostic performance comparable with that of FSE T2WI for meniscal, cartilage and ligament injuries of the knee joint.


Korean Journal of Radiology | 2013

Initial experience with the new double-lumen scepter balloon catheter for treatment of wide-necked aneurysms

Myung Ho Rho; Byung Moon Kim; Sang Hyun Suh; Dong Joon Kim; Dong Ik Kim

Objective A new double-lumen balloon catheter was being developed for the treatment of cerebral aneurysms. The purpose of this study is to report our initial experience of a double-lumen balloon catheter for the treatment of wide-necked aneurysms. Materials and Methods Seventeen patients (mean age, 63 years; range, 45-80 years) with wide-necked, with or without a branch-incorporated aneurysms, (10 ruptured and 9 unruptured) were treated with balloon-assisted coil embolization using a double-lumen balloon catheter (Scepter C™ or Scepter XC™) for 7 months after being introduced to our country. Locations of the aneurysms were posterior communicating artery (n = 7), anterior communicating artery or A2 (n = 7), middle cerebral artery (MCA) bifurcation (n = 3), basilar artery tip (n = 1) and anterior choroidal artery (n = 1). The initial clinical and angiographic outcomes were retrospectively evaluated. Results Coil embolization was successfully completed in all 19 aneurysms, resulting in complete occlusions (n = 18) or residual neck (n = 1). In one procedure, a thrombus formation was detected at the neck portion of the ruptured MCA bifurcation aneurysm near to the end of the procedure. It was completely resolved with an intra-arterial infusion of Glycoprotein IIb/IIIa inhibitor (Tirofiban, 1.0 mg) without any clinical sequela. There were no treatment-related events in the remaining 18 aneurysms. At discharge, functional neurological state improved in 11 patients (10 patients with ruptured aneurysm and 1 with unruptured aneurysm presenting with mass symptoms) and 6 patients with unruptured aneurysms had no newly developed symptoms. Conclusion In this preliminary case series, the newly developed double-lumen Scepter balloon appears to be a safe and convenient device for coil embolization of wide-necked aneurysms.


British Journal of Radiology | 2010

Eosinophilic cystitis associated with eosinophilic enterocolitis: case reports and review of the literature.

Mi Sung Kim; Hee-Jin Park; C S Park; E J Lee; Myung Ho Rho; N H Park; J Joh

We report three cases of eosinophilic cystitis. Contrast-enhanced computed tomography (CT) revealed characteristic bladder wall thickening exceeding 10 mm, with preservation of the mucosal lining and intense, progressive contrast enhancement on sequential arterial and delayed scans. Eosinophilic cystitis might have been associated with eosinophilic infiltration in other organs, such as the gastrointestinal tracts and liver.


Acta Radiologica | 2016

Modified thoracolumbar injury classification and severity score (TLICS) and its clinical usefulness

Hee Jin Park; So Yeon Lee; Noh Hyuck Park; Hun Gyu Shin; Eun Chul Chung; Myung Ho Rho; Mi Sung Kim; Heon Ju Kwon

Background Thoracolumbar injury classification and severity score (TLICS) is not very reliable for assessment of injury to the posterior ligament complex, even when scored by experts. It is not reasonable to score every compression fracture or burst fracture the same as there is great variety in the severity of compression fractures and burst fractures. Purpose To propose a modified TLICS (mTLICS) and evaluate the performance of the mTLICS system by measuring the agreement between scores determined by radiologists using both systems and actual treatment procedure delivered. Material and Methods We retrospectively evaluated 134 patients with acute lumbar and thoracic spinal trauma after undergoing magnetic resonance imaging (MRI) using new mTLICS and conventional TLICS system. Inter-observer agreements of TLICS and mTLICS scores were analyzed using the kappa statistic. Nonparametric correlation analysis was used to determine correlation (R) among each score and the surgical intervention. Results The mTLICS system showed slightly higher correlation than TLICS (Rs, TLICS, 0.592 and 0.613 vs. mTLICS, 0.628 and 0.639). If we consider a total maximal score of 4 to be a negative surgical indication, mTLICS showed significantly higher sensitivities than TLICS, and if we consider a total minimal score of 4 to be a positive surgical indication, mTLICS showed significantly higher specificities than TLICS. Conclusion The mTLICS score corrects deficiencies in the TLICS system that lead to ambiguity in the radiological diagnostic criteria. mTLICS is a more suitable scoring system than TLICS for predicting surgical management accurately, especially for morphological injuries.


British Journal of Radiology | 2013

Clinical correlation of a new practical MRI method for assessing central lumbar spinal stenosis

Hee-Jin Park; Kim Ss; Youn-Soo Lee; So Yeon Lee; Park Nh; Yoon Jung Choi; Eun Chul Chung; Myung Ho Rho

OBJECTIVE To evaluate interobserver agreement and determine whether a new MRI grading system agrees with symptoms and neurological signs. METHODS We examined 160 patients (72 males and 88 females; mean age 57 years) who underwent MRI of the lumbar spine at our institution and were evaluated by two musculoskeletal radiologists. The presence and grade of central lumbar spinal stenosis (CLSS) at L3-4, L4-5 and L5-S1 were assessed according to a new grading system, the Lee system. The results were correlated with clinical manifestations and neurological examinations [positive neurological manifestation (PNM) and negative neurological manifestation (NNM)]. Statistical analyses were performed using kappa statistics and non-parametric correlation analysis (Spearmans correlation). RESULTS Interobserver agreement in the grading of CLSS between the two readers was substantial (κ=0.780). Interobserver agreement of the L4-5 level and older age group was high (0.789, 0.814). The correlation coefficient (R) of Reader 1 between MRI Grades 0, 1, 2 or 3 and neurological manifestations (negative or positive) was 0.654; the R of Reader 2 was 0.591. In the younger age group (<57 years), the R of Reader 1 was 0.634 and the R of Reader 2 was 0.500. In the older age group (≥57 years), the R of Reader 1 was 0.650 and the R of Reader 2 was 0.645. Correlation coefficients were higher at the L3-4 level (0.612-0.678) than at other levels but did not show statistical significance (p>0.05). CONCLUSION Interobserver agreement for the new CLSS grading system was substantial. Grade 0 was associated with NNMs and Grade 3 with PNMs in this cohort. Grade 2 demonstrates more cases of PNM than NNM but requires further evaluation. Correlations between MRI grades and clinical manifestations were moderate and slightly higher in older patients. ADVANCES IN KNOWLEDGE The new practical MRI grading method can be useful in the categorisation of CLSS and shows strong clinical correlation.


Neurological Research | 2015

Multiple overlapping stent-assisted coiling of complex aneurysms: a single-center experience

Yu Sam Won; Myung Ho Rho; Eun Chul Chung; Hyun Pyo Hong; Sae Yung Kim; Hee Jin Park; Yoon Jung Choi; So Yeon Lee; Chun Sik Choi; Yon Kwon Ihn

Abstract Objectives: Coil embolization of wide-necked and fusiform aneurysms is challenging and is frequently associated with recanalization despite assistance of any additional device. The purpose of this study was to evaluate the feasibility and mid-term outcomes of complex aneurysms after multiple overlapping stent-assisted coiling (OSAC). Methods: We retrospectively evaluated 26 wide-necked and fusiform atherosclerotic or dissecting aneurysms that were treated with multiple OSAC. Eight aneurysms (30·8%) presented with subarachnoid hemorrhage and one (3·9%) with intracranial hemorrhage. Results: Complete embolization was achieved in 15 of the 26 aneurysms (57·7%), while remnant neck was identified in nine (34·6%) and remnant aneurysm was noted in two (7·7%). Immediate procedure-related complications were observed in five patients (19·2%) including two with asymptomatic in-stent thrombosis, one with transient right-sided weakness, one with decreased mentality, and one with aphasia and quadriplegia. A procedure-related permanent neurologic deficit (modified Rankin scale scores of 1 and 5) was noted in two patients (7·7%). Angiographic follow-up (mean duration 23·9 months) after OSAC was carried out in 18 patients (69·2%): 11 (61·1%) were stable, 3 (16·7%) improved, 3 (16·7%) had minor compaction, and 1 had major recanalization (5·5%). One recurred aneurysm after OSAC and two recanalized aneurysms after single stenting were re-treated using additional stent-assisted coiling, and there was no recanalization in these three aneurysms during the 25·7 months after re-treatment. Conclusions: Multiple OSAC is feasible and effective for complex aneurysms and recurrent aneurysms after stent-assisted coiling.

Collaboration


Dive into the Myung Ho Rho's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

So Yeon Lee

Sungkyunkwan University

View shared research outputs
Top Co-Authors

Avatar

Hee Jin Park

Sungkyunkwan University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Mi Sung Kim

Sungkyunkwan University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Yu Sam Won

Sungkyunkwan University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Heon Ju Kwon

Sungkyunkwan University

View shared research outputs
Researchain Logo
Decentralizing Knowledge