Acta Biomaterialia | 2008

Polyester vascular prostheses coated with a cyclodextrin polymer and activated with antibiotics: cytotoxicity and microbiological evaluation.

Nicolas Blanchemain; Thomas Laurent; Feng Chai; Christel Neut; Stéphan Haulon; Vera Krump-Konvalinkova; Michel Morcellet; Bernard Martel; C. James Kirkpatrick; Hartmut F. Hildebrand

Polyester (PET) vascular grafts are used to replace or bypass damaged arteries. To minimize the risk of infection during and after surgical interventions, a PET vascular prosthesis (Polythese) was functionalized with cyclodextrin polymers (PolyCDs) in order to obtain the controlled release of antibiotics (ABs: ciprofloxacin, vancomcyin and rifampicin). An epithelial cell line (L132) was used to determine the viability of the antibiotics, and human pulmonary microvascular endothelial cells (HPMEC) were used for cell proliferation by cell counting and cell vitality with Alamar Blue fluorescent dye. Staphylococcus aureus, Escherichia coli and Enteroccocus sp. were used to determine the antimicrobial activity of AB-loaded virgin and PolyCD-grafted Polythese by the minimum inhibitory concentration method. The spectrophotometric titration results first showed that a larger amount of ABs was sorbed onto PolyCD-coated Polythese compared to virgin Polythese (26.7 vs. 35.3 mg g(-1), 51.1 vs. 72.4 mg g(-1) and 4.1 vs. 21.0 mg g(-1), respectively, for rifampicin, vancomycin and ciprofloxacin). These results were further confirmed by a microbiological test, which showed AB-loaded PolyCD-coated Polythese displayed better antimicrobial activity. The viability test revealed the toxicity of rifampicin (22 mg l(-1)) and ciprofloxacin (35 mg l(-1)), and the absence of toxicity of vancomycin. These tests allow us to further explain the lower vitality and proliferation of HPMEC on the AB-loaded PolyCD-coated Polythese, which was due not to the functionalization process of prostheses but to the cytotoxicity of certain ABs themselves. Moreover, such a property could be exploited to tackle intracellular bacteria, such as in tuberculosis and other diseases, and will not compromise further in vivo applications of our functionalized vascular prostheses.


International Journal of Pharmaceutics | 2010

Bone implants modified with cyclodextrin: Study of drug release in bulk fluid and into agarose gel

T.H. Hoang Thi; Feng Chai; S. Leprêtre; Nicolas Blanchemain; Bernard Martel; F. Siepmann; Hartmut F. Hildebrand; Juergen Siepmann; M.P. Flament

The aim of this work was to better understand the importance of the type of experimental setup used to monitor antibiotic release from functionalized hydroxyapatite implants. Microporous hydroxyapatite discs were prepared by sintering and subsequently functionalized with hydroxypropyl-β-cyclodextrin (HPβCD) polymer crosslinked with butanetetracarboxylic acid. On one hand, polymerization was performed within the implant after its impregnation with the monomers (CD-HA-M implant). On the other hand, a pre-synthesized HPβCD polymer was loaded and fixed onto the HA discs (CD-HA-P implant). Both types of implants were soaked with ciprofloxacin hydrochloride or vancomycin hydrochloride solution and dried at 37°C. The DSC study highlighted that the cyclodextrin polymer could interfere with both drugs, due to the carboxylic groups carried by the crosslinks. Drug release was measured into phosphate buffered saline pH 7.4 in agitated vials, or into agarose gels to more realistically mimic in vivo conditions. Importantly, in all cases, drug release into agarose gels was much slower than into well-agitated phosphate buffer. Non-functionalized discs displayed faster drug release because no complex could be formed and/or due to the absence of the HPβCD polymer network hindering drug diffusion within the implant pores. In the case of ciprofloxacin hydrochloride, drug release from the CD-HA-M implants was faster than drug release from the CD-HA-P implants due to the different polymer structures resulting in different complexation strengths, whereas in the case of vancomycin hydrochloride the release patterns were similar because vancomycin hydrochloride was not included into the cyclodextrin. The agarose gel method seems more biorelevant and discriminatory than the vial method for drug release measurements from bone implants.


Acta Biomaterialia | 2011

Methyl-β-cyclodextrin modified vascular prosthesis: Influence of the modification level on the drug delivery properties in different media

Nicolas Blanchemain; Y. Karrout; Nicolas Tabary; Christel Neut; Marc Bria; Juergen Siepmann; Hartmut F. Hildebrand; Bernard Martel

A textile polyester vascular graft was modified with methyl-β-cyclodextrin (MeβCD) to obtain a new implant capable of releasing antibiotics directly in situ at the site of operation over a prolonged period and thereby prevent post-operative infections. We investigated the influence of the curing parameters (time and temperature) that allow control of the degree of functionalization (DF) of the support by MeβCD. The inclusion of ciprofloxacin (CFX) in the MeβCD cavity was observed in solution by two-dimensional (1)H NMR spectroscopy. The amount of CFX loaded on the modified graft increased with DF. Depending on the release medium (water, phosphate-buffered saline, or human plasma) and the DF of the prostheses, different kinetic profiles of release of CFX were obtained. The sustained release of CFX in human plasma was shown by microbiological assays that indicated prolonged antimicrobial activity against Staphylococcus aureus and Escherichia coli. Viability tests demonstrated the non-toxicity of MeβCD to an epithelial cell line (HPMEC), although a decrease in endothelial cell number was observed on the functionalized prosthesis, probably due to the roughness of the coating and also to the nature of the MeβCD polymer present on the surface of the fibers.


Carbohydrate Polymers | 2012

Comparative study of vascular prostheses coated with polycyclodextrins for controlled ciprofloxacin release

Nicolas Blanchemain; Y. Karrout; Nicolas Tabary; Marc Bria; Christel Neut; Hartmut F. Hildebrand; Juergen Siepmann; Bernard Martel

A textile polyester vascular graft was modified with cyclodextrins to obtain a new implant capable of releasing antibiotics (here ciprofloxacin, CFX) over prolonged time periods and thereby reducing the risk of post-operative infections. In this study, we compared samples modified with native and modified cyclodextrins, presenting different cavity sizes (β or γ cyclodextrins) and different substituent groups (hydroxypropyl and methyl). Drug release was measured in water, phosphate buffer pH 7.4 and blood plasma. The inclusion of CFX in the cyclodextrins cavities was observed in solution by two-dimensional (1)H NMR spectroscopy and confirmed by (1)F NMR measurements. Grafts modification with all cyclodextrins induced an increase of their sorption capacity towards CFX whose extent depended on the nature of the cyclodextrin: a 4-fold and 10-fold increase was observed in the cases of hydroxypropyl cyclodextrins and methylated β-cyclodextrin, respectively. Depending on the type of release medium and nature of CD, different CFX release kinetics were obtained. The discussion highlighted not only the role of the host guest complexation, but also that of the electrostatic interactions that occur between the anionic crosslinks of the cyclodextrins polymers, and CFX that presents a zwitterionic character. The microbiological assessment confirmed sustained CFX release in human plasma and demonstrated antibacterial efficiency of CD modified prostheses against Staphylococcus aureus and Escherichia coli for at least 24 h (compared to 4 h in the case of virgin grafts).


ACS Applied Materials & Interfaces | 2015

Bioinspired Titanium Drug Eluting Platforms Based on a Poly-β-cyclodextrin–Chitosan Layer-by-Layer Self-Assembly Targeting Infections

Alexandra Pérez-Anes; Myriem Gargouri; William Laure; Hélène Van Den Berghe; Elisabeth Courcot; Jonathan Sobocinski; Nicolas Tabary; Feng Chai; Jean-François Blach; Ahmed Addad; Patrice Woisel; Dennis Douroumis; Bernard Martel; Nicolas Blanchemain; Joël Lyskawa

In the field of implantable titanium-based biomaterials, infections and inflammations are the most common forms of postoperative complications. The controlled local delivery of therapeutics from implants through polyelectrolyte multilayers (PEMs) has recently emerged as a versatile technique that has shown great promise in the transformation of a classical medical implant into a drug delivery system. Herein, we report the design and the elaboration of new biodegradable multidrug-eluting titanium platforms based on a polyelectrolyte multilayer bioactive coating that target infections. These systems were built up in mild conditions according to the layer-by-layer (L-b-L) assembly and incorporate two biocompatible polysaccharides held together through electrostatic interactions. A synthetic, negatively charged β-cyclodextrin-based polymer (PCD), well-known for forming stable and reversible complexes with hydrophobic therapeutic agents, was exploited as a multidrug reservoir, and chitosan (CHT), a naturally occurring, positively charged polyelectrolyte, was used as a barrier for controlling the drug delivery rate. These polyelectrolyte multilayer films were strongly attached to the titanium surface through a bioinspired polydopamine (PDA) film acting as an adhesive first layer and promoting the robust anchorage of PEMs onto the biomaterials. Prior to the multilayer film deposition, the interactions between both oppositely charged polyelectrolytes, as well the multilayer growth, were monitored by employing surface plasmon resonance (SPR). Several PEMs integrating 5, 10, and 15 bilayers were engineered using the dip coating strategy, and the polyelectrolyte surface densities were estimated by colorimetric titrations and gravimetric analyses. The morphologies of these multilayer systems, as well as their naturally occurring degradation in a physiological medium, were investigated by scanning electron microscopy (SEM), and their thicknesses were measured by means of profilometry and ellipsometry studies. Finally, the ability of the coated titanium multilayer devices to act as a drug-eluting system and to treat infections was validated with gentamicin, a relevant water-soluble antibiotic commonly used in medicine due to its broad bactericidal spectrum.


Biomedical Materials | 2012

Anticoagulant and antimicrobial finishing of non-woven polypropylene textiles

Stéphanie Degoutin; Maude Jimenez; Mathilde Casetta; Séverine Bellayer; Feng Chai; Nicolas Blanchemain; Christel Neut; I Kacem; M. Traisnel; Bernard Martel

The aim of this work is to prepare non-woven polypropylene (PP) textile functionalized with bioactive molecules in order to improve its anticoagulation and antibacterial properties. This paper describes the optimization of the grafting process of acrylic acid (AA) on low-pressure cold-plasma pre-activated PP, the characterization of the modified substrates and the effect of these modifications on the in vitro biological response towards cells. Then, the immobilization of gentamicin (aminoglycoside antibiotic) and heparin (anticoagulation agent) has been carried out on the grafted samples by either ionic interactions or covalent linkages. Their bioactivity has been investigated and related to the nature of their interactions with the substrate. For gentamicin-immobilized AA-grafted samples, an inhibition radius and a reduction of 99% of the adhesion of Escherichia coli have been observed when gentamicin was linked by ionic interactions, allowing the release of the antibiotic. By contrast, for heparin-immobilized AA-grafted PP samples, a strong increase of the anticoagulant effect up to 35 min has been highlighted when heparin was covalently bonded on the substrate, by contact with the blood drop.


Acta Biomaterialia | 2014

A chlorhexidine-loaded biodegradable cellulosic device for periodontal pockets treatment

Nicolas Tabary; Feng Chai; Nicolas Blanchemain; Christel Neut; Lucile Pauchet; Sabrina Bertini; Elisabeth Delcourt-Debruyne; Hartmut F. Hildebrand; Bernard Martel

Absorbent points widely used in endodontic therapy were transformed into bioresorbable chlorhexidine delivery systems for the treatment of the periodontal pocket by preventing its recolonization by the subgingival microflora. These paper points (PPs) were first oxidized to promote their resorption, then grafted with β-cyclodextrin (CD) or maltodextrin (MD) in order to achieve sustained delivery of chlorhexidine. We investigated the oxidation step parameters through the time of reaction and the nitric and phosphoric acid ratios in the oxidizing mixture, and then the dextrin grafting step parameters through the time and temperature of reaction. A first selection of the appropriate functionalization parameters was undertaken in relation to the degradation profile kinetics of the oxidized (PPO) and oxidized-grafted samples (PPO-CD and PPO-MD). Samples were then loaded with chlorhexidine digluconate (digCHX), a widely used antiseptic agent in periodontal therapy. The release kinetics of digCHX from PPO-CD and PPO-MD samples were compared to PP, PPO and to PerioChip(®) (a commercial digCHX containing gelatine chip) in phosphate buffered saline (pH 7.4) by ultraviolet spectrophotometry. The cytocompatibility of the oxidized-grafted PP was demonstrated by cell proliferation assays. Finally, the disc diffusion test from digCHX loaded PPO-MD samples immersed in human plasma was developed on pre-inoculated agar plates with four common periodontal pathogenic strains: Fusobacterium nucleatum, Prevotella melaninogenica, Aggregatibacter actinomycetem comitans and Porphyromonas gingivalis. To conclude, the optimized oxidized-dextrin-grafted PPs responded to our initial specifications in terms of resorption and digCHX release rates and therefore could be adopted as a reliable complementary periodontal therapy.


Materials Science and Engineering: C | 2013

Validating the poly-cyclodextrins based local drug delivery system on plasma-sprayed hydroxyapatite coated orthopedic implant with toluidine blue O

M. Taha; Feng Chai; Nicolas Blanchemain; M. Goube; Bernard Martel; H.F. Hildebrand

Local antibiotics delivery is an efficient solution to reduce the risk of infections associated with orthopedic implant. This study aims to functionalize plasma-sprayed hydroxyapatite coated titanium (Ti-HA) hip joint implant material with cyclodextrins-polymer (polyCD)-based local drug delivery system for loading therapeutic molecules (e.g. antibiotics), to offer a sustainable drug delivery. The process of polyCD coating on Ti-HA material was optimized with the help of model guest molecule - toluidine blue O (TBO) for evaluating the efficacy of polyCD system. The obtained results clearly showed that polyCDs treatment can firmly coat on the Ti-HA material under the optimized processing parameters concerning the type of CD, thermal treatment temperature and duration. PolyCD system has been proven to have a high capacity of TBO adsorption and long release duration. In vitro study also showed non-cytotoxicity of polyCD functionalized samples to osteoblastic cells. Trial study with gentamicin revealed very promising potential of polyCD system for sustained delivery of antibiotics. To conclude, the study substantiates the prospective flexibility of drug choice when applying polyCD treated implants including antibiotics, antimitotic agents or other therapeutical molecules. One or more drugs can be loaded, thus synergism and multi-factorial effects are feasible.


International Journal of Pharmaceutics | 2014

Visceral mesh modified with cyclodextrin for the local sustained delivery of ropivacaine

Guillaume Vermet; Stéphanie Degoutin; Feng Chai; Mickael Maton; Marc Bria; Cécile Danel; Hartmut F. Hildebrand; Nicolas Blanchemain; Bernard Martel

The aim of the study was to develop a polyester visceral implant modified with a cyclodextrin polymer for the local and prolonged delivery of ropivacaine to reduce post operatory pain. Therefore, we applied a coating of an inguinal mesh with a crosslinked polymer of hydroxypropyl-β-cyclodextrin (HPβCD) whose specific host-guest complex forming properties were expected to improve the adsorption capacity of the implant toward anesthetic, and then to release it within a sustained period. The modification reaction of the textile with cyclodextrin was explored through the study of the influence of the pad/dry/cure process parameters and the resulting implant (PET-CD) was characterized by solid state NMR and SEM. Besides, the inclusion complex between ropivacaine and CD was studied by NMR and capillary electrophoresis in PBS medium. Finally, ropivacaine sorption test showed that a maximum of 30 mg/g of ropivacaine could be adsorbed on the functionalized samples. In dynamic batch tests in PBS at pH 7.4, the release could be observed up to 6h. The cytocompatibility of the PET-CD loaded with ropivacaine was also studied and reached 65% cell vitality after 6 days.


International Journal of Pharmaceutics | 2014

Evaluation of sorption capacity of antibiotics and antibacterial properties of a cyclodextrin-polymer functionalized hydroxyapatite-coated titanium hip prosthesis

Mariam Taha; Feng Chai; Nicolas Blanchemain; Christel Neut; Michel Goube; Mickael Maton; Bernard Martel; Hartmut F. Hildebrand

Infection still present as one of common complications after total hip replacement (∼2.5%), which may cause serious outcomes. For preventing such risk, loading antibiotics onto implants for increasing local drug concentration at targeted sites could be a solution. This study aims at modifying the surface of hydroxyapatite (HA) coated titanium hip implant material (Ti-HA) with polymer of cyclodextrin (polyCD) for loading antibiotics, to achieve a sustained local drug delivery. Two widely applied antibiotics (tobramycin and rifampicin) in orthopedic surgery were loaded alone or in combination. The drug adsorption isotherm, drug release kinetics and drugs efficacy were thoroughly investigated. The results proved that polyCD coating significantly improved the affinity of both drugs to Ti-HA surface, while the mechanism of drug-polyCD interaction varies from the nature of drug, courtesy of the structural complex of polyCD. The advantage of dual-drug loading was highlighted by its strong efficacy against both Staphylococcus aureus and Enterobacter cloacae, which overcomes the limitation of mono-drug loading for an effective treatment against both bacterial strains. The prolonged antibacterial activity of antibiotic loaded Ti-HA-polyCD samples confirmed that polyCD could be a promising drug-delivery system, for sustained antibiotics release or other potential applications e.g., antimitotic agent release.

Collaboration


Dive into the Nicolas Blanchemain's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Bernard Martel

Science Applications International Corporation

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Bernard Martel

Science Applications International Corporation

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Michel Morcellet

Centre national de la recherche scientifique

View shared research outputs
Researchain Logo
Decentralizing Knowledge