Prashant Laxman Kole
Queen's University Belfast
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Prashant Laxman Kole.
Biomedical Chromatography | 2011
Prashant Laxman Kole; Gantala Venkatesh; Jignesh Kotecha; Ravi Sheshala
This paper reviews the recent developments in bioanalysis sample preparation techniques and gives an update on basic principles, theory, applications and possibilities for automation, and a comparative discussion on the advantages and limitation of each technique. Conventional liquid-liquid extraction (LLE), protein precipitation (PP) and solid-phase extraction (SPE) techniques are now been considered as methods of the past. The last decade has witnessed a rapid development of novel sample preparation techniques in bioanalysis. Developments in SPE techniques such as selective sorbents and in the overall approach to SPE, such as hybrid SPE and molecularly imprinted polymer SPE, have been addressed. Considerable literature has been published in the area of solid-phase micro-extraction and its different versions, e.g. stir bar sorptive extraction, and their application in the development of selective and sensitive bioanalytical methods. Techniques such as dispersive solid-phase extraction, disposable pipette extraction and micro-extraction by packed sorbent offer a variety of extraction phases and provide unique advantages to bioanalytical methods. On-line SPE utilizing column-switching techniques is rapidly gaining acceptance in bioanalytical applications. PP sample preparation techniques such as PP filter plates/tubes offer many advantages like removal of phospholipids and proteins in plasma/serum. Newer approaches to conventional LLE techniques (salting-out LLE) are also covered in this review article.
Advanced Functional Materials | 2012
Ryan F. Donnelly; Thakur Raghu Raj Singh; Martin J. Garland; Katarzyna Migalska; Rita Majithiya; Cian M. McCrudden; Prashant Laxman Kole; Tuan Mazlelaa Tuan Mahmood; Helen O. McCarthy; A. David Woolfson
Unique microneedle arrays prepared from crosslinked polymers, which contain no drug themselves, are described. They rapidly take up skin interstitial fluid upon skin insertion to form continuous, unblockable, hydrogel conduits from attached patch-type drug reservoirs to the dermal microcirculation. Importantly, such microneedles, which can be fabricated in a wide range of patch sizes and microneedle geometries, can be easily sterilized, resist hole closure while in place, and are removed completely intact from the skin. Delivery of macromolecules is no longer limited to what can be loaded into the microneedles themselves and transdermal drug delivery is now controlled by the crosslink density of the hydrogel system rather than the stratum corneum, while electrically modulated delivery is also a unique feature. This technology has the potential to overcome the limitations of conventional microneedle designs and greatly increase the range of the type of drug that is deliverable transdermally, with ensuing benefits for industry, healthcare providers and, ultimately, patients.
British Journal of Clinical Pharmacology | 2009
Nadia Rashid Al Mazroui; Mostafa Mohamed Kamal; Naserdeen Mehana Ghabash; Targ Ahmed Yacout; Prashant Laxman Kole; James McElnay
AIMS To examine the influence of a pharmaceutical care programme on disease control and health-related quality of life in Type 2 diabetes patients in the United Arab Emirates. METHODS A total of 240 Type 2 diabetes patients were recruited into a randomized, controlled, prospective clinical trial with a 12-month follow-up. A range of clinical measures, medication adherence and health-related quality of life (Short Form 36) were evaluated at baseline and up to 12 months. Intervention group patients received pharmaceutical care from a clinical pharmacist, whereas control group patients received their usual care from medical and nursing staff. The primary outcome measure was change in HbA(1c). British National Formulary and Framingham scoring methods were used to estimate changes in 10-year coronary heart disease risk scores in all patients. RESULTS A total of 234 patients completed the study. Significant reductions (P < 0.001) in mean values (baseline vs. 12 months; 95% confidence interval) of HbA(1c)[8.5% (8.3, 8.7) vs. 6.9% (6.7, 7.1)], systolic [131.4 mmHg (128.1, 134.7) vs. 127.2 mmHg (124.4, 130.1)] and diastolic blood pressure [85.2 mmHg (83.5, 86.8) vs. 76.3 mmHg (74.9, 77.7)] were observed in the intervention group; no significant changes were noted in the control group. The mean Framingham risk prediction score in the intervention group was 10.56% (9.7, 11.4) at baseline; this decreased to 7.7% (6.9, 8.5) (P < 0.001) at 12 months but remained unchanged in the control group. CONCLUSIONS The pharmaceutical care programme resulted in better glycaemic control and reduced cardiovascular risk scores in Type 2 diabetes patients over a 12-month period.
International Journal of Pharmaceutics | 2013
Ryan F. Donnelly; Thakur Raghu Raj Singh; Ahlam Zaid Alkilani; Maeliosa McCrudden; Shannon O’Neill; Conor O’Mahony; Keith Armstrong; Nabla McLoone; Prashant Laxman Kole; A. David Woolfson
We describe, for the first time, the microbial characterisation of hydrogel-forming polymeric microneedle arrays and the potential for passage of microorganisms into skin following microneedle penetration. Uniquely, we also present insights into the storage stability of these hydroscopic formulations, from physical and microbiological viewpoints, and examine clinical performance and safety in human volunteers. Experiments employing excised porcine skin and radiolabelled microorganisms showed that microorganisms can penetrate skin beyond the stratum corneum following microneedle puncture. Indeed, the numbers of microorganisms crossing the stratum corneum following microneedle puncture were greater than 10⁵ cfu in each case. However, no microorganisms crossed the epidermal skin. When using a 21G hypodermic needle, more than 10⁴ microorganisms penetrated into the viable tissue and 10⁶ cfu of Candida albicans and Staphylococcus epidermidis completely crossed the epidermal skin in 24 h. The hydrogel-forming materials contained no microorganisms following de-moulding and exhibited no microbial growth during storage, while also maintaining their mechanical strength, apart from when stored at relative humidities of 86%. No microbial penetration through the swelling microneedles was detectable, while human volunteer studies confirmed that skin or systemic infection is highly unlikely when polymeric microneedles are used for transdermal drug delivery. Since no pharmacopoeial standards currently exist for microneedle-based products, the exact requirements for a proprietary product based on hydrogel-forming microneedles are at present unclear. However, we are currently working towards a comprehensive specification set for this microneedle system that may inform future developments in this regard.
Journal of Chromatography B | 2010
Maysa Suyagh; Prashant Laxman Kole; Jeff S. Millership; Paul S. Collier; Henry L. Halliday; James McElnay
A selective and sensitive liquid chromatography (LC)-atmospheric pressure chemical ionisation (APCI)-mass spectroscopic (MS) assay of canrenone has been developed and validated employing Dried Blood Spots (DBS) as the sample collection medium. DBS samples were prepared by applying 30 microl of spiked whole blood onto Guthrie cards. A 6mm disc was punched from the each DBS and extracted with 2 ml of methanolic solution of 17alpha-methyltestosterone (Internal Standard). The methanolic extract was evaporated to dryness and reconstituted in acetonitrile:water (1:9, v/v). The reconstituted solution was further subjected to solid phase extraction using HLB cartridges. Chromatographic separation was achieved using Waters Sunfire C18 reversed-phase column using isocratic elution, followed by a high organic wash to clear late eluting/highly retained components. The mobile phase consisted of methanol:water (60:40, v/v) pumped at a flow rate of 0.3 ml/min. LC-APCI-MS detection was performed in the selected-ion monitoring (SIM) mode using target ions at m/z 341.1 and 303.3 for canrenone and internal standard respectively. The selectivity of the method was established by analysing DBS samples from 6 different sources (individuals). The calibration curve for canrenone was found to be linear over 25-1000 ng/ml (r>0.994). Accuracy (% RE) and precision (% CV) values for within and between day were <20% at the lower limit of quantification (LLQC) and <15% at all other concentrations tested. The LLOQ of the method was validated at 25 ng/ml. Clinical validation of the method was achieved by employing the validated method for analysis of 160 DBS samples from 37 neonatal and paediatric patients.
Talanta | 2011
Prashant Laxman Kole; Jeff S. Millership; James McElnay
A novel stir bar sorptive extraction (SBSE) method coupled with high performance liquid chromatography (HPLC) and UV detection for the extraction of diclofenac (DIC) from paediatric urine samples has been developed and validated. Selectivity and sensitivity being the prime objectives of the bioanalytical method for clinical samples, an optimised SBSE protocol was developed that selectively extracted DIC from various concurrently administered drugs. The validated assay was found to be linear (r=0.9999) over a concentration range of 100-2000 ng mL(-1). SBSE showed consistent recoveries (∼ 70%) of DIC across the validated linearity range. Overall, the method exhibited excellent accuracy and precision across all QC concentrations, tested over three days. Calculated LOD and LOQ were found to be 12.03 ng mL(-1) and 36.37 ng mL(-1), respectively, however, for the experimental purposes, 100 ng mL(-1) was considered as the validated LOQ (accuracy and precision at this LQC was <20%). Further, studies on various attributes of the stir bar/SBSE, showed no significant inter- and intra-stir bar variability for DIC extraction. There was no carryover effect with re-use of conditioned stir bars and for the first time, a systematic investigation on the effect of ageing of stir bars on their extraction efficiency was carried out. Results showed that, for the present study, stir bars which were used 150 times were still functional based on in-house acceptance criteria and extraction efficiency. The validated method was successfully applied to the analysis of DIC in paediatric clinical trial samples.
Journal of Pharmaceutical and Biomedical Analysis | 2011
Prashant Laxman Kole; Jeff S. Millership; James McElnay
A new stir bar sorptive extraction (SBSE) technique coupled with HPLC-UV method for quantification of diclofenac in pharmaceutical formulations has been developed and validated as a proof of concept study. Commercially available polydimethylsiloxane stir bars (Twister™) were used for method development and SBSE extraction (pH, phase ratio, stirring speed, temperature, ionic strength and time) and liquid desorption (solvents, desorption method, stirring time etc) procedures were optimised. The method was validated as per ICH guidelines and was successfully applied for the estimation of diclofenac from three liquid formulations viz. Voltarol(®) Optha single dose eye drops, Voltarol(®) Ophtha multidose eye drops and Voltarol(®) ampoules. The developed method was found to be linear (r=0.9999) over 100-2000ng/ml concentration range with acceptable accuracy and precision (tested over three QC concentrations). The SBSE extraction recovery of the diclofenac was found to be 70% and the LOD and LOQ of the validated method were found to be 16.06 and 48.68ng/ml, respectively. Furthermore, a forced degradation study of a diclofenac formulation leading to the formation of structurally similar cyclic impurity (indolinone) was carried out. The developed extraction method showed comparable results to that of the reference method, i.e. method was capable of selectively extracting the indolinone and diclofenac from the liquid matrix. Data on inter and intra stir bar accuracy and precision further confirmed robustness of the method, supporting the multiple re-use of the stir bars.
Biomedical Chromatography | 2011
Shadab A. Pathan; Gaurav K. Jain; Syed M. A. Zaidi; Sohail Akhter; Divya Vohora; Prakash Chander; Prashant Laxman Kole; Farhan Jalees Ahmad; Roop K. Khar
Thymoquinone (THQ) is known for its neuroprotective and anti-convulsant properties in preclinical studies. We herewith describe a simple, rapid, selective, sensitive and stability-indicating UPLC method for the estimation of THQ and its application to biopharmaceutical studies such as in vitro release from nanoparticulate system and in vivo pharmacokinetic study. The method employed gradient elution using a Waters Acquity HSS-T3 C(18) (100 × 2.1 mm, 1.8 µm) UPLC column. The mobile phase consisted of water and acetonitrile, pumped at a flow rate of 0.5 mL/min. The injection volume was 5 µL and THQ was monitored at 294 nm wavelength with a total run time of 6 min. In solution as well as in plasma, the method was found to be linear (r ≥ 0.998), precise (CV ≤ 2.45%) and accurate (recovery ≥ 84.8%) in the selected concentration range of 0.1-0.8 µg/mL. Forced degradation studies revealed that THQ undergoes degradation under acidic, basic, oxidation and UV light stress conditions. However, the developed UPLC method could effectively resolve degradation product peaks from THQ. Further, no interference was found at the retention time of THQ from any plasma components, indicating selectivity of the developed method. For solutions, the limits of detection and quantitation of the method were found to be 0.001 and 0.0033 µg/mL, respectively; while in plasma they were 0.006 and 0.02 µg/mL, respectively. The validated method was successfully applied to quantify THQ in dissolution medium as well as oral in vivo pharmacokinetic study of THQ suspension and THQ- solid lipid nanoparticle (THQ-SLN) formulation. A 2-fold increase in the relative bioavailability was observed with the THQ-SLN compared with THQ. The results indicate that the SLN significantly increased plasma concentrations and retention within the systemic circulation.
Journal of Chromatography B | 2011
Prashant Laxman Kole; Rita Majithia; Thakur Raghu Raj Singh; Martin J. Garland; Katarzyna Migalska; Ryan F. Donnelly; James McElnay
An HPLC-UV-dried blood spot (DBS) method for the estimation of metronidazole (MTZ) in rat whole blood is reported. Method employs Ahlstrom 226 sample collection paper and DBS samples were prepared by spotting with 30 μl of whole blood (spiked calibration standards/quality control samples/in vivo study samples). A 6mm disc was punched from each DBS and extraction was carried out using water containing the internal standard (tinidazole). The calibration for MTZ was linear over 2.5-50 μg/ml concentration range. Accuracy (% bias) and precision (expressed as % Coefficient of variation) values for within and between day were <20% at the lower level quality control sample (LQC) and <15% at all other concentrations tested. The limit of quantification (LOQ) of the method was 2.5 μg/ml. The validated method was applied for the analysis of in vivo pharmacokinetic (PK) study samples after intravenous administration of MTZ to a rat. Whole blood PK parameters observed in this study were in compliance with literature based PK parameters. The DBS sampling approach was found to be useful in a single animal pharmacokinetic study.
Journal of Hypertension | 2013
Maysa Suyagh; Ahmed F. Hawwa; Paul S. Collier; Jeffrey S. Millership; Prashant Laxman Kole; Muriel Millar; Michael D. Shields; Henry L. Halliday; James McElnay
Objective: To characterize the population pharmacokinetics of canrenone following administration of potassium canrenoate (K-canrenoate) in paediatric patients. Methods: Data were collected prospectively from 37 paediatric patients (median weight 2.9 kg, age range 2 days–0.85 years) who received intravenous K-canrenoate for management of retained fluids, for example in heart failure and chronic lung disease. Dried blood spot (DBS) samples (n = 213) from these were analysed for canrenone content and the data subjected to pharmacokinetic analysis using nonlinear mixed-effects modelling. Another group of patients (n = 16) who had 71 matching plasma and DBS samples was analysed separately to compare canrenone pharmacokinetic parameters obtained using the two different matrices. Results: A one-compartment model best described the DBS data. Significant covariates were weight, postmenstrual age (PMA) and gestational age. The final population models for canrenone clearance (CL/F) and volume of distribution (V/F) in DBS were CL/F (l/h) = 12.86 × (WT/70.0)0.75 × e [0.066 × (PMA - 40]) and V/F (l) = 603.30 × (WT/70) × (GA/40)1.89 where weight is in kilograms. The corresponding values of CL/F and V/F in a patient with a median weight of 2.9 kg are 1.11 l/h and 20.48 l, respectively. Estimated half-life of canrenone based on DBS concentrations was similar to that based on matched plasma concentrations (19.99 and 19.37 h, respectively, in 70 kg patient). Conclusion: The range of estimated CL/F in DBS for the study population was 0.12–9.62 l/h; hence, bodyweight-based dosage adjustment of K-canrenoate appears necessary. However, a dosing scheme that takes into consideration both weight and age (PMA/gestational age) of paediatric patients seems more appropriate.