Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where R. Neilson is active.

Publication


Featured researches published by R. Neilson.


Physical Review Letters | 2012

Search for Neutrinoless Double-Beta Decay in 136 Xe with EXO-200

M. Auger; A. P. Waite; W. Feldmeier; T. N. Johnson; M. Hughes; P. C. Rowson; A. Kuchenkov; J. D. Wright; J.-L. Vuilleumier; T. Walton; K. Graham; C. G. Davis; A. Pocar; David A. Sinclair; K. Hall; A. Odian; S. Delaquis; K.S. Kumar; L. J. Kaufman; R. MacLellan; K. Twelker; M. Breidenbach; R. DeVoe; A. Burenkov; G. Giroux; S. Herrin; A. Sabourov; T. Brunner; P. Vogel; L. Yang

We report on a search for neutrinoless double-beta decay of 136Xe with EXO-200. No signal is observed for an exposure of 32.5 kg yr, with a background of ∼1.5×10(-3)  kg(-1) yr(-1)  keV(-1) in the ±1σ region of interest. This sets a lower limit on the half-life of the neutrinoless double-beta decay T(1/2)(0νββ)(136Xe)>1.6×10(25)  yr (90% C.L.), corresponding to effective Majorana masses of less than 140-380 meV, depending on the matrix element calculation.


Physical Review Letters | 2012

Search for Neutrinoless Double-Beta Decay in 136Xe with EXO-200

M. Auger; D. J. Auty; P. S. Barbeau; E. Beauchamp; V. Belov; C. Benitez-Medina; M. Breidenbach; T. Brunner; A. Burenkov; B. Cleveland; S. Cook; T. Daniels; M. Danilov; C. G. Davis; S. Delaquis; R. DeVoe; A. Dobi; M. J. Dolinski; A. Dolgolenko; M. Dunford; W. Fairbank; J. Farine; W. Feldmeier; P. Fierlinger; D. Franco; G. Giroux; R. Gornea; K. Graham; G. Gratta; C. Hall

We report on a search for neutrinoless double-beta decay of 136Xe with EXO-200. No signal is observed for an exposure of 32.5 kg yr, with a background of ∼1.5×10(-3)  kg(-1) yr(-1)  keV(-1) in the ±1σ region of interest. This sets a lower limit on the half-life of the neutrinoless double-beta decay T(1/2)(0νββ)(136Xe)>1.6×10(25)  yr (90% C.L.), corresponding to effective Majorana masses of less than 140-380 meV, depending on the matrix element calculation.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2008

Systematic study of trace radioactive impurities in candidate construction materials for EXO-200

D.S. Leonard; P. Grinberg; P. Weber; E. Baussan; Z. Djurcic; G. Keefer; A. Piepke; A. Pocar; J.-L. Vuilleumier; J.-M. Vuilleumier; D. Akimov; A. Bellerive; M. Bowcock; M. Breidenbach; A. Burenkov; R. Conley; W. Craddock; M. Danilov; R. DeVoe; M. S. Dixit; A. Dolgolenko; I. Ekchtout; W. Fairbank; J. Farine; P. Fierlinger; B. Flatt; G. Gratta; M. P. Green; C. Hall; K. Hall

The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma counting, alpha counting, neutron activation analysis, and high-sensitivity mass spectrometry.


Journal of Instrumentation | 2012

The EXO-200 detector, part I: detector design and construction

M. Auger; D. J. Auty; P.S. Barbeau; L. Bartoszek; E. Baussan; E. Beauchamp; C. Benitez-Medina; M. Breidenbach; D. Chauhan; B. Cleveland; R. Conley; J. Cook; S. Cook; A. Coppens; W.W. Craddock; T. Daniels; C. G. Davis; J. Davis; R. DeVoe; A. Dobi; M. J. Dolinski; M. Dunford; W. Fairbank; J. Farine; P. Fierlinger; D. Franco; G. Giroux; R. Gornea; K. Graham; G. Gratta

EXO-200 is an experiment designed to search for double beta decay of 136Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most innovative aspects of the design that revolve around the reduction of backgrounds, the efficient use of the expensive isotopically enriched xenon, and the optimization of the energy resolution in a relatively large volume.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2009

Characterization of large area APDs for the EXO-200 detector

R. Neilson; F. LePort; A. Pocar; K.S. Kumar; A. Odian; C.Y. Prescott; V. Tenev; Nicole Ackerman; D. Akimov; M. Auger; C. Benitez-Medina; M. Breidenbach; A. Burenkov; R. Conley; S. Cook; R. DeVoe; M. J. Dolinski; W. Fairbank; J. Farine; P. Fierlinger; B. Flatt; R. Gornea; G. Gratta; M. P. Green; C. Hall; K. Hall; D. Hallman; C. Hargrove; S. Herrin; J. Hodgson

EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-lowbackground liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169 K—the temperature of liquid xenon. We also describe the individual characterization of more than 800 LAAPDs for selective installation in the EXO-200 detector.


Physical Review A | 2007

Observation of single collisionally cooled trapped ions in a buffer gas

M. P. Green; J. Wodin; R. DeVoe; P. Fierlinger; B. Flatt; G. Gratta; F. LePort; M. Montero Díez; R. Neilson; K. O'Sullivan; A. Pocar; S. Waldman; D.S. Leonard; A. Piepke; U Alabama; C. Hargrove; D. Sinclair; V. Strickland; U Carleton; W. Fairbank; K. Hall; B. Mong; M. K. Moe; U Laurentian; U Neuchatel

Individual Ba ions are trapped in a gas-filled linear ion trap and observed with a high signal-to-noise ratio by resonance fluorescence. Single-ion storage times of {approx}5 min ({approx}1 min) are achieved using He (Ar) as a buffer gas at pressures in the range 8x10{sup -5}-4x10{sup -3} torr. Trap dynamics in buffer gases are experimentally studied in the simple case of single ions. In particular, the cooling effects of light gases such as He and Ar and the destabilizing properties of heavier gases such as Xe are studied. A simple model is offered to explain the observed phenomenology.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2012

Xenon purity analysis for EXO-200 via mass spectrometry

A. Dobi; C. Hall; S. Slutsky; B. Aharmin; M. Auger; P.S. Barbeau; C. Benitez-Medina; M. Breidenbach; B. Cleveland; R. Conley; J. Cook; S. Cook; I. Counts; W.W. Craddock; T. Daniels; C. G. Davis; J. Davis; R. DeVoe; M. S. Dixit; M. J. Dolinski; K. Donato; W. Fairbank; J. Farine; P. Fierlinger; D. Franco; G. Giroux; R. Gornea; K. Graham; G. Gratta; C. Green

Abstract We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We have used the technique to screen the EXO-200 xenon before, during, and after its use in our detector, and these measurements have proven useful. This is the first application of the cold trap mass spectrometry technique to an operating physics experiment.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2011

A xenon gas purity monitor for EXO

A. Dobi; C. Hall; S. Herrin; A. Odian; C.Y. Prescott; P.C. Rowson; Nicole Ackerman; B. Aharmin; M. Auger; P.S. Barbeau; K. Barry; C. Benitez-Medina; M. Breidenbach; S. Cook; I. Counts; T. Daniels; R. DeVoe; M. J. Dolinski; K. Donato; W. Fairbank; J. Farine; G. Giroux; R. Gornea; K. Graham; G. Gratta; M. P. Green; C. Hagemann; K. Hall; D. Hallman; C. Hargrove

We discuss the design, operation, and calibration of two versions of a xenon gas purity monitor (GPM) developed for the EXO double beta decay program. The devices are sensitive to concentrations of oxygen well below 1 ppb at an ambient gas pressure of one atmosphere or more. The theory of operation of the GPM is discussed along with the interactions of oxygen and other impurities with the GPM’s tungsten filament. Lab tests and experiences in commissioning the EXO-200 double beta decay experiment are described.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2007

A Linear RFQ Ion Trap for the Enriched Xenon Observatory

B. Flatt; M. P. Green; J. Wodin; R. DeVoe; P. Fierlinger; G. Gratta; F. LePort; M. Montero Díez; R. Neilson; K. O’Sullivan; A. Pocar; S. Waldman; E. Baussan; M. Breidenbach; R. Conley; W. Fairbank; J. Farine; C. Hall; K. Hall; D. Hallman; C. Hargrove; M. Hauger; J. Hodgson; F. Juget; D.S. Leonard; D. Mackay; Y. Martin; B. Mong; A. Odian; L. Ounalli

The design, construction, and performance of a linear radio-frequency ion trap (RFQ) intended for use in the Enriched Xenon Observatory (EXO) are described. EXO aims to detect the neutrinoless double-beta decay of {sup 136}Xe to {sup 136}Ba. To suppress possible backgrounds EXO will complement the measurement of decay energy and, to some extent, topology of candidate events in a Xe filled detector with the identification of the daughter nucleus ({sup 136}Ba). The ion trap described here is capable of accepting, cooling, and confining individual Ba ions extracted from the site of the candidate double-beta decay event. A single trapped ion can then be identified, with a large signal-to-noise ratio, via laser spectroscopy.


Review of Scientific Instruments | 2011

A magnetically driven piston pump for ultra-clean applications

F. LePort; R. Neilson; P.S. Barbeau; K. Barry; L. Bartoszek; I. Counts; J. Davis; R. DeVoe; M. J. Dolinski; G. Gratta; M. Green; M. Montero Díez; A. R. Müller; K. O’Sullivan; A. Rivas; K. Twelker; B. Aharmim; M. Auger; V. Belov; C. Benitez-Medina; M. Breidenbach; A. Burenkov; B. Cleveland; R. Conley; J. Cook; S. Cook; W.W. Craddock; T. Daniels; M. S. Dixit; A. Dobi

A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon time projection chamber of EXO-200. The pump, using sprung polymer gaskets, is capable of pumping more than 16 standard liters per minute of xenon gas with 750 Torr differential pressure.

Collaboration


Dive into the R. Neilson's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

W. Fairbank

Colorado State University

View shared research outputs
Top Co-Authors

Avatar

J. Farine

Laurentian University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

M. P. Green

Oak Ridge National Laboratory

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge